930 resultados para Data-driven
Resumo:
P>The determination of normal parameters is an important procedure in the evaluation of the stomatognathic system. We used the surface electromyography standardization protocol described by Ferrario et al. (J Oral Rehabil. 2000;27:33-40, 2006;33:341) to determine reference values of the electromyographic standardized indices for the assessment of muscular symmetry (left and right side, percentage overlapping coefficient, POC), potential lateral displacing components (unbalanced contractile activities of contralateral masseter and temporalis muscles, TC), relative activity (most prevalent pair of masticatory muscles, ATTIV) and total activity (integrated areas of the electromyographic potentials over time, IMPACT) in healthy Brazilian young adults, and the relevant data reproducibility. Electromyography of the right and left masseter and temporalis muscles was performed during maximum teeth clenching in 20 healthy subjects (10 women and 10 men, mean age 23 years, s.d. 3), free from periodontal problems, temporomandibular disorders, oro-facial myofunctional disorder, and with full permanent dentition (28 teeth at least). Data reproducibility was computed for 75% of the sample. The values obtained were POC Temporal (88 center dot 11 +/- 1 center dot 45%), POC masseter (87 center dot 11 +/- 1 center dot 60%), TC (8 center dot 79 +/- 1 center dot 20%), ATTIV (-0 center dot 33 +/- 9 center dot 65%) and IMPACT (110 center dot 40 +/- 23 center dot 69 mu V/mu V center dot s %). There were no statistical differences between test and retest values (P > 0 center dot 05). The Technical Errors of Measurement (TEM) for 50% of subjects assessed during the same session were 1 center dot 5, 1 center dot 39, 1 center dot 06, 3 center dot 83 and 10 center dot 04. For 25% of the subjects assessed after a 6-month interval, the TEM were 0 center dot 80, 1 center dot 03, 0 center dot 73, 12 center dot 70 and 19 center dot 10. For all indices, there was good reproducibility. These electromyographic indices could be used in the assessment of patients with stomatognathic dysfunction.
Resumo:
Context: Type 1 pseudohypoaldosteronism (PHA1), a primary form of mineralocorticoid resistance, isdueto inactivating mutations of the NR3C2 gene, coding for the mineralocorticoid receptor (MR). Objective: The objective of the study was to assess whether different NR3C2 mutations have distinct effects on the pattern of MR-dependent transcriptional regulation of aldosterone-regulated genes. Design and Methods: Four MR mutations affecting residues in the ligand binding domain, identified in families with PHA1, were tested. MR proteins generated by site-directed mutagenesis were analyzed for their binding to aldosterone and were transiently transfected into renal cells to explore the functional effects on the transcriptional activity of the receptors by cis-trans-cotrans-activation assays and by measuring the induction of endogenous gene transcription. Results: Binding assays showed very low or absent aldosterone binding for mutants MR(877Pro), MR(848Pro), and MR(947stop) and decreased affinity for aldosterone of MR(843Pro). Compared with wildtype MR, the mutations p.Leu843Pro and p.Leu877Pro displayed half-maximal aldosterone-dependent transactivation of reporter genes driven by mouse mammary tumor virus or glucocorticoid response element-2 dependent promoters, whereas MR(848Pro) and MR(947stop) nearly or completely lost transcriptional activity. Although MR(848Pro) and MR(947stop) were also incapable of inducing aldosterone-dependent gene expression ofendogenoussgk1, GILZ, NDRG2, and SCNN1A, MR(843Pro) retained complete transcriptional activity on sgk1 and GILZ gene expression, and MR(877Pro) negatively affected the expression of sgk1, NDRG2, and SCNN1A. Conclusions: Our data demonstrate that MR mutations differentially affect individual gene expression in a promoter-dependent manner. Investigation of differential gene expression profiles in PHA1 may allow a better understanding of the molecular substrate of phenotypic variability and to elucidate pathogenic mechanisms underlying the disease. (J Clin Endocrinol Metab 96: E519-E527, 2011)
Resumo:
In 2007 Associate Professor Jay Hall retires from the University of Queensland after more than 30 years of service to the Australian archaeological community. Celebrated as a gifted teacher and a pioneer of Queensland archaeology, Jay leaves a rich legacy of scholarship and achievement across a wide range of archaeological endeavours. An Archæological Life brings together past and present students, colleagues and friends to celebrate Jay’s contributions, influences and interests.
Resumo:
Purpose: Orthodontic miniscrews are commonly used to achieve absolute anchorage during tooth movement. One of the most frequent complications is screw loss as a result of root contact. Increased precision during the process of miniscrew insertion would help prevent screw loss and potential root damage, improving treatment outcomes. Stereo lithographic surgical guides have been commonly used for prosthetic implants to increase the precision of insertion. The objective of this paper was to describe the use of a stereolithographic surgical guide suitable for one-component orthodontic miniscrews based on cone beam computed tomography (CBCT) data and to evaluate implant placement accuracy. Materials and Methods: Acrylic splints were adapted to the dental arches of four patients, and six radiopaque reference points were filled with gutta-percha. The patients were submitted to CBCT while they wore the occlusal splint. Another series of images was captured with the splint alone. After superimposition and segmentation, miniscrew insertion was simulated using planning software that allowed the user to check the implant position in all planes and in three dimensions. In a rapid-prototyping machine, a stereolithographic guide was fabricated with metallic sleeves located at the insertion points to allow for three-dimensional control of the pilot bur. The surgical guide was worn during surgery. After implant insertion, each patient was submitted to CBCT a second time to verify the implant position and the accuracy of the placement of the miniscrews. Results: The average differences between the planned and inserted positions for the ten miniscrews were 0.86 mm at the coronal end, 0.71 mm at the center, and 0.87 mm at the apical tip. The average angular discrepancy was 1.76 degrees. Conclusions: The use of stereolithographic surgical guides based on CBCT data allows for accurate orthodontic mini screw insertion without damaging neighboring anatomic structures. INT J ORAL MAXILLOFAC IMPLANTS 2011;26:860-865
Resumo:
The literature shows contradictory results regarding the role of composite shrinkage and elastic modulus as determinants of polymerization stress. The present study aimed at a better understanding of the test mechanics that could explain such divergences among studies. The hypothesis was that the effects of composite shrinkage and elastic modulus on stress depend upon the compliance of the testing system. A commonly used test apparatus was simulated by finite element analysis, with different compliance levels defined by the bonding substrate (steel, glass, composite, or acrylic). Composites with moduli between 1 and 12 GPa and shrinkage values between 0.5% and 6% were modeled. Shrinkage was simulated by thermal analogy. The hypothesis was confirmed. When shrinkage and modulus increased simultaneously, stress increased regardless of the substrate. However, if shrinkage and modulus were inversely related, their magnitudes and interaction with rod material determined the stress response.