890 resultados para Critical thinking training
Resumo:
Animals sensitized to allergens change their feeding behavior and avoid drinking the otherwise preferred sweetened solutions containing the allergens. This phenomenon, known as food aversion, appears to be mediated by allergen-specific IgE antibodies. Here we investigated food aversion in BALB/c and C57BL/6 mice, which differ in their allergic responses to the allergen ovalbumin as well as in their preference for sweet taste. BALB/c mice present higher levels of IgE and a natural lower preference for sweet flavors when compared to C57BL/6 mice. Specifically, we studied a conflicting situation in which animals simultaneously experienced the aversive contact with the allergen and the attractive sweet taste of increasing concentrations of sucrose. We found that BALB/c mice were more prone to develop food aversion than C57BL/6 mice and that this aversive behavior could be abolished in both strains by increasing the palatability of the solution containing the allergen. In both strains food aversion was positively correlated with the levels of allergen-specific IgE antibodies and inversely correlated with their preference for sucrose sweetened solutions. (C) 2009 Elsevier Inc. All rights reserved.
Resumo:
Objective: Exercise training improves plasma lipid profile and diminishes risk of coronary heart disease. Previously, we showed that training increases LDL plasma clearance, as tested by an artificial LDL-like nanoemulsion method, presumably by increasing LDL receptor activity. In this study, we investigated whether training could also improve LDL clearance in hypercholesterolemic subjects (HCh) that are exposed to increased risk of cardiovascular events. Methods: Twenty sedentary HCh and 20 normolipidemic (NL) sedentary volunteers were divided into four groups: 12 HCh submitted to 4-month training program, 8 HCh with no exercise program, 12 NL submitted to 4-month training and 8 NL with no exercise program. An LDL-like nanoemulsion labeled with 14C-cholesteryl ester was injected intravenously into all subjects and plasma samples were collected during 24h after injection to determine the fractional clearance rate (FCR, in h-1) by compartmental analysis. The study was performed on the first and on the last day of the 4-month study period. Results: In both, trained HCh and NL groups, training increased nanoemulsion FCR by 36% (0.0443 +/- 0.0126; 0.0602 +/- 0.0187, p=0.0187 and 0.0503 +/- 0.0203; 0.0686 +/- 0.0216, p=0.0827, respectively). After training, LDL cholesterol diminished in both HCh and NL groups. In HCh, but not in NL group, LDL susceptibility to oxidation decreased, but oxidized LDL was unchanged. In both non-trained groups FCR was the same for the last and the 4-month previous evaluation. Conclusion: In HCh, exercise training increased the removal of LDL as tested by the nanoemulsion, and this probably accounted for decreased LDL cholesterol and diminished LDL susceptibility to oxidation. (C) 2010 Elsevier Ireland Ltd. All rights reserved.
Resumo:
Objective. The goal of this paper is to undertake a literature search collecting all dentin bond strength data obtained for six adhesives with four tests ( shear, microshear, tensile and microtensile) and to critically analyze the results with respect to average bond strength, coefficient of variation, mode of failure and product ranking. Method. A PubMed search was carried out for the years between 1998 and 2009 identifying publications on bond strength measurements of resin composite to dentin using four tests: shear, tensile, microshear and microtensile. The six adhesive resins were selected covering three step systems ( OptiBond FL, Scotch Bond Multi-Purpose Plus), two-step (Prime & Bond NT, Single Bond, Clear. l SE Bond) and one step (Adper Prompt L Pop). Results. Pooling results from 147 references showed an ongoing high scatter in the bond strength data regardless which adhesive and which bond test was used. Coefficients of variation remained high (20-50%) even with the microbond test. The reported modes of failure for all tests still included high number of cohesive failures. The ranking seemed to be dependant on the test used. Significance. The scatter in dentin bond strength data remains regardless which test is used confirming Finite Element Analysis predicting non-uniform stress distributions due to a number of geometrical, loading, material properties and specimens preparation variables. This reopens the question whether, an interfacial fracture mechanics approach to analyze the dentin - adhesive bond is not more appropriate for obtaining better agreement among dentin bond related papers. (C) 2009 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.
Resumo:
Objective. To evaluate the biaxial and short-beam uniaxial strength tests applied to resin composites based upon their Weibull parameters, fractographic features and stress distribution. Methods. Disk- (15 mm x 1 mm) and beam-shaped specimens (10 mm x 2 mm x 1 mm) of three commercial composites (Concept/Vigodent, CA; Heliomolar/Ivoclar-Vivadent, HE; Z250/3M ESPE, FZ) were prepared. After 48h dry storage at 37 degrees C, disks and beams were submitted to piston-on-three-balls (BI) and three-point bending (UNI) tests, respectively. Data were analyzed by Weibull statistics. Fractured surfaces were observed under stereomicroscope and scanning electron microscope. Maximum principal stress (sigma(1)) distribution was determined by finite element analysis (FEA). Maximum sigma(1-BI) and sigma(1-UNI) were compared to FZ strengths calculated by applying the average failure loads to the analytical equations (sigma(a-BI) and sigma(a-UNI)). Results. For BI, characteristic strengths were: 169.9a (FZ), 122.4b (CA) and 104.8c (HE), and for UNI were: 160.3a (FZ), 98.2b (CA) and 91.6b (HE). Weibull moduli ( m) were similar within the same test. CA and HE presented statistically higher m for BI. Surface pores ( BI) and edge flaws ( UNI) were the most frequent fracture origins. sigma(1-BI) was 14% lower than sigma(a-BI.) sigma(1-UNI) was 43% higher than sigma(a-UNI). Significance. Compared to the short-beam uniaxial test, the biaxial test detected more differences among composites and displayed less data scattering for two of the tested materials. Also, biaxial strength was closer to the material`s strength estimated by FEA. (C) 2009 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.