806 resultados para Critical Care


Relevância:

60.00% 60.00%

Publicador:

Resumo:

Objective: Few data have been published regarding protein losing enteropathy in adult patients with burns. This study characterised the presence of protein-losing enteropathy in adults with burns and examined the relationship between the magnitude of bum size and the severity of protein loss. Methods: Twenty adult patients with burns (BSA 31+/-25%, range 2-80%) were studied. Fluid resuscitation was based on the Parkland's formula. Protein loss into the gastrointestinal tract was measured using faecal alpha(1)-antitrypsin (FA-1-AT) concentrations. Serial measurements of serum protein and albumin concentrations were performed. Results: Fourteen patients demonstrated elevations in FA-1-AT levels. The mean peak FA-1-AT level was 3.6+/-4.2 mg/g dry weight of stool. Two patients demonstrated elevated FA-1-AT excretion 1.5 months and 3 months after the bums. There was a good correlation between burn size and FA-1-AT excretion (R-2=0.40). Conclusions: Protein losing enteropathy was demonstrable in patients with major burns. The magnitude of this phenomenon appears to be proportional to the burns size.

Relevância:

60.00% 60.00%

Publicador:

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Background: The Functional Capacity Index (FCI) was designed to predict physical function 12 months after injury. We report a validation study of the FCI. Methods: This was a consecutive case series registered in the Queensland Trauma Registry who consented to the prospective 12-month telephone-administered follow-up study. FCI scores measured at 12 months were compared with those originally predicted. Results: Complete Abbreviated Injury Scale score information was available for 617 individuals, of whom 587 (95%) could be assigned at least one FCI score (range, 1-17). Agreement between the largest predicted FCI and observed FCI score was poor (kappa = 0.05; 95% confidence interval, 0.00-0.10) and explained only 1% of the variability in observed FCI. Using an encompassing model that included all FCI assignments, agreement remained poor (kappa = 0.05; 95% confidence interval, -0.02-0.12), and the model explained only 9% of the variability in observed FCI. Conclusion: The predicted functional capacity poorly agrees with actual functional outcomes. Further research should consider including other (noninjury) explanatory factors in predicting FCI at 12 months.

Relevância:

60.00% 60.00%

Publicador:

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Purpose To assess the psychometric properties of the Simplified Therapeutic Intervention Scoring System (TISS 28) scale. Materials and Methods A prospective observational design was used. Patients were recruited from a medical-surgical intensive care unit (ICU) and 4 rehabilitation wards of 2 university-affiliated hospitals in Hong Kong. Results Data necessary for the calculation of the TISS 28, the Therapeutic Intervention Scoring System (TISS 76), and severity of illness scoring system (Simplified Acute Physiology Score [SAPS II]) were recorded for each patient during the first 24 hours after his/her admission to an ICU. A significant positive correlation was found between the TISS 76 and the TISS 28 scores as well as the TISS 28 and the SAPS II scores. There was a significant difference between the TISS 28 scores among ICU patients and patients in rehabilitation wards. A significant correlation was found between the TISS 28 scores of the first and second set of TISS 28 scores. Conclusions Although the findings supported the validity and reliability of the TISS 28, there were limitations of the TISS 28 in measuring nursing workload in ICUs. Hence, continued amendment and validation of the TISS 28 on larger samples in different ICUs would be required so as to provide clinical nurses with a valid and reliable assessment of nursing workload.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Objective: To investigate the effects of recombinant human activated protein C (rhAPC) on pulmonary function in acute lung injury (ALI) resulting from smoke inhalation in association with a bacterial challenge. Design: Prospective, randomized, controlled, experimental animal study with repeated measurements. Setting: Investigational intensive care unit at a university hospital. Subjects: Eighteen sheep (37.2 +/- 1.0 kg) were operatively prepared and randomly allocated to either the sham, control, or rhAPC group (n = 6 each). After a tracheotomy had been performed, ALI was produced in the control and rhAPC group by insufflation of 4 sets of 12 breaths of cotton smoke. Then, a 30 mL suspension of live Pseudomonas aeruginosa bacteria (containing 2-5 x 10(11) colony forming units) was instilled into the lungs according to an established protocol. The sham group received only the vehicle, i.e., 4 sets of 12 breaths of room air and instillation of 30 mL normal saline. The sheep were studied in the awake state for 24 hrs and were ventilated with 100% oxygen. RhAPC (24 mu g/kg/hr) was intravenously administered. The infusion was initiated 1 hr post-injury and lasted until the end of the experiment. The animals were resuscitated with Ringer's lactate solution to maintain constant pulmonary artery occlusion pressure. Measurements and Main Results., In comparison with nontreatment in controls, the infusion of rhAPC significantly attenuated the fall in PaO2/FiO(2) ratio (control group values were 521 +/- 22 at baseline [BL], 72 +/- 5 at 12 hrs, and 74 +/- 7 at 24 hrs, vs. rhAPC group values of 541 +/- 12 at BL, 151 +/- 29 at 12 hours [p < .05 vs. control], and 118 +/- 20 at 24 hrs), and significantly reduced the increase in pulmonary microvascular shunt fraction (Qs/Qt; control group at BL, 0.14 +/- 0.02, and at 24 hrs, 0.65 +/- 0.08; rhAPC group at BL, 0.24 +/- 0.04, and at 24 hrs, 0.45 +/- 0.02 [p < .05 vs. control]) and the increase in peak airway pressure (mbar; control group at BL, 20 +/- 1, and at 24 hrs, 36 +/- 4; rhAPC group at BL, 21 +/- 1, and at 24 hrs, 28 +/- 2 [p < .05 vs. control]). In addition, rhAPC limited the increase in lung 3-nitrotyrosine (after 24 hrs [%]: sham, 7 +/- 2; control, 17 +/- 1; rhAPC, 12 +/- 1 [p < .05 vs. control]), a reliable indicator of tissue injury. However, rhAPC failed to prevent lung edema formation. RhAPC-treated sheep showed no difference in activated clotting time or platelet count but exhibited less fibrin degradation products (1/6 animals) than did controls (4/6 animals). Conclusions. Recombinant human activated protein C attenuated ALI after smoke inhalation and bacterial challenge in sheep, without bleeding complications.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Objective: Transcranial Doppler (TCD) ultrasonography is a technique that uses a hand-held Doppler transducer (placed on the surface of the cranial skin) to measure the velocity and pulsatility of blood flow within the intracranial and the extracranial arteries. This review critically evaluates the evidence for the use of TCD in the critical care population. Discussion: TCD has been frequently employed for the clinical evaluation of cerebral vasospasm following subarachnoid haemorrhage (SAH). To a lesser degree, TCD has also been used to evaluate cerebral autoregulatory capacity, monitor cerebral circulation during cardiopulmonary bypass and carotid endarterectomies and to diagnose brain death. Technological advances such as M mode, colour Doppler and three-dimensional power Doppler ultrasonography have extended the scope of TCD to include other non-critical care applications including assessment of cerebral emboli, functional TCD and the management of sickle cell disease. Conclusions: Despite publications suggesting concordance between TCD velocity measurements and cerebral blood flow there are few randomized controlled studies demonstrating an improved outcome with the use of TCD monitoring in neurocritical care. Newer developments in this technology include venous Doppler, functional Doppler and use of ultrasound contrast agents.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This report describes the case of an 88-year-old non-diabetic female who presented to the emergency department following a presumed hypoijtycaemic collapse due to self-neglect. Subsequent rewarming and resuscitation demonstrated a number of the significant consequences of severe hypothermia, including apparent secondary impairment of glycaemic autoregulation. The phenomenon of reversible inhibition of insulin secretion due to severe hypothermia has been documented previously in the field of cardiac surgery. The hyperglycaemia was not treated with any antihyperglycaernic agent, and her recovery was uneventful. Subsequent blood sugar level monitoring was normal. If insulin is administered to the hypothermic patient, intensive monitoring of blood glucose is essential due to the increase in endogenous insulin secretion on rewarming. (c) 2005 Elsevier Ireland Ltd. All rights reserved.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The Laryngeal Mask Airway is a reusable device for maintaining the patency of a patient's airway during general anaesthesia. The device can be reused after it has been cleaned and sterilized. Protein contamination of medical instruments is a concern and has been found to occur despite standard sterilization techniques. The reason for the concern relates to the possibility of the transmission of prions and the risk of developing a neurodegenerative disorder such as Creutzveldt-Jacob disease. The purpose of this study was to quantify the amount of protein contamination that occurs, and to relate this to the number of times the Laryngeal Mask Airway has been used. Fifty previously used Classic Laryngeal Masks were collected after routine sterilization and packaging. The devices were immersed in protein detecting stain and then visual inspection performed to assess the degree and distribution of the staining. The researcher was blinded to the number of times the Laryngeal Mask Airway had been used. Linear regression analysis of the degrees of staining of the airway revealed that protein contamination occurs after the first use of the device and this increases with each subsequent use. This finding highlights the concern that the currently used cleaning and sterilization methods do not prevent the accumulation of proteinaceous material on Laryngeal Mask Airways. Consideration should be given to the search for more efficient cleaning and sterilization techniques or the use of disposable devices.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Objective: To compare the total plasma cortisol values obtained from three widely used immunoassays and a high pressure liquid chromatography (HPLC) technique on samples obtained from patients with sepsis. Design and setting: Observational interventional in the general intensive care unit of a metropolitan hospital. Patients and participants: Patients admitted to the intensive care unit with a diagnosis of sepsis and fulfilling criteria of systemic inflammatory response syndrome. Interventions: Standard short synacthen test performed with 250 mu g cosyntropin. Measurements and results: Two of the three immunoassays returned results significantly higher than those obtained by HPLC: Immulite by 95% (95%CI 31-188%) and TDx by 79% (21-165%). The limits of agreement for all three immunoassays with HPLC ranged from -62% to 770%. In addition, by classifying the patients into responders and non-responders to ACTH by standard criteria there was concordance in all assays in only 44% of patients. Conclusions: Immunoassay estimation of total plasma cortisol in septic patients shows wide assay related variation that may have significant impact in the diagnosis of relative adrenal insufficiency.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

We reviewed the outcome following use of recombinant activated factor VII (rVIIa) in patients with major bleeding post cardiothoracic surgery in our unit between January 2002 and July 2004. The unit consists of 16 cardiothoracic intensive care beds in a public metropolitan teaching hospital which serves as a referral centre for heart and lung transplant surgery Patients with refactory bleeding following cardiothoracic surgical procedures who were treated with rVIIa were identified. A total of 12 episodes of rVIIa use were recorded in ten patients, including three episodes with ventricular assist devices, and 5 heart and/or lung transplants. The median dose used was 85 mu g/kg. Chest tube drainage decreased in all patients following administration of rVIIa; median chest tube drainage decreased front 445 ml/h to 171 ml/h (P=0.03). Despite cessation of bleeding, mortality was high, when rVIIa was used after more than 24 hours. In six episodes, despite early rVIIa use (within six hours), continued bleeding necessitated return to theatre, where a surgical source of bleeding was found. In this small retrospective study, rVIIa significantly reduced bleeding that was refractory to standard blood product transfusion. In this series of patients., those that did not respond to rVIla early in the postoperative phase were found to have a surgical source of bleeding.