917 resultados para Corneal biomechanics
Resumo:
The simplified model of human tear fluid (TF) is a three-layered structure composed of a homogenous gel-like layer of hydrated mucins, an aqueous phase, and a lipid-rich outermost layer found in the tear-air interface. It is assumed that amphiphilic phospholipids are found adjacent to the aqueous-mucin layer and externally to this a layer composed of non-polar lipids face the tear-air interface. The lipid layer prevents evaporation of the TF and protects the eye, but excess accumulation of lipids may lead to drying of the corneal epithelium. Thus the lipid layer must be controlled and maintained by some molecular mechanisms. In the circulation, phospholipid transfer protein (PLTP) and cholesteryl ester transfer protein (CETP) mediate lipid transfers. The aim of this thesis was to investigate the presence and molecular mechanisms of lipid transfer proteins in human TF. The purpose was also to study the role of these proteins in the development of dry eye syndrome (DES). The presence of TF PLTP and CETP was studied by western blotting and mass spectrometry. The concentration of these proteins was determined by ELISA. The activities of the enzymes were determined by specific lipid transfer assays. To study the molecular mechanisms involved in PLTP mediated lipid transfer Langmuir monolayers and asymmetrical flow field-flow fractionation (AsFlFFF) was used. Ocular tissue samples were stained with monoclonal antibodies against PLTP to study the secretion route of PLTP. Heparin-Sepharose affinity chromatography was used for PLTP pull-down experiments and co-eluted proteins were identified with MALDI-TOF mass spectrometry or Western blot analysis. To study whether PLTP plays any functional role in TF PLTP-deficient mice were examined. The activity of PLTP was also studied in dry eye patients. PLTP is a component of normal human TF, whereas CETP is not. TF PLTP concentration was about 2-fold higher than that in human plasma. Inactivation of PLTP by heat treatment or immunoinhibition abolished the phospholipid transfer activity in tear fluid. PLTP was found to be secreted from lacrimal glands. PLTP seems to be surface active and is capable of accepting lipid molecules without the presence of lipid-protein complexes. The active movement of radioactively labeled lipids and high activity form of PLTP to acceptor particles suggested a shuttle model of PLTP-mediated lipid transfer. In this model, PLTP physically transports lipids between the donor and acceptor. Protein-protein interaction assays revealed ocular mucins as PLTP interaction partners in TF. In mice with a full deficiency of functional PLTP enhanced corneal epithelial damage, increased corneal permeability to carboxyfluorescein, and decreased corneal epithelial occludin expression was demonstrated. Increased tear fluid PLTP activity was observed among human DES patients. These results together suggest a scavenger property of TF PLTP: if the corneal epithelium is contaminated by hydrophobic material, PLTP could remove them and transport them to the superficial layer of the TF or, alternatively, transport them through the naso-lacrimal duct. Thus, PLTP might play an integral role in tear lipid trafficking and in the protection of the corneal epithelium. The increased PLTP activity in human DES patients suggests an ocular surface protective role for this lipid transfer protein.
Resumo:
QSPR-malli kuvaa kvantitatiivista riippuvuutta muuttujien ja biologisen ominaisuuden välillä. Näin ollen QSPR mallit ovat käyttökelpoisia lääkekehityksen apuvälineitä. Kirjallisessa osassa kerrotaan sarveiskalvon, suoliston ja veriaivoesteen permeabiliteetin malleista. Useimmin käytettyjä muuttujia ovat yhdisteen rasvaliukoisuus, polaarinen pinta-ala, vetysidosten muodostuminen ja varaus. Myös yhdisteen koko vaikuttaa läpäisevyyteen, vaikka tutkimuksissa onkin erilaista tietoa tämän merkittävyydestä. Malliin vaikuttaa myös muiden kuin mallissa mukana olevien muuttujien suuruusluokka esimerkkinä Lipinskin ‖rule of 5‖ luokittelu. Tässä luokittelussa yhdisteen ominaisuus ei saa ylittää tiettyjä raja-arvoja. Muussa tapauksessa sen imeytyminen suun kautta otettuna todennäköisesti vaarantuu. Lisäksi kirjallisessa osassa tutustuttiin kuljetinproteiineihin ja niiden toimintaan silmän sarveiskalvossa, suolistossa ja veriaivoesteessä. Nykyisin on kehitetty erilaisia QSAR-malleja kuljetinproteiineille ennustamaan mahdollisten substraatittien tai inhibiittorien vuorovaikutuksia kuljetinproteiinin kanssa. Kokeellisen osan tarkoitus oli rakentaa in silico -malli sarveiskalvon passiiviselle permeabiliteetille. Työssä tehtiin QSPR-malli 54 yhdisteen ACDLabs-ohjelmalla laskettujen muuttujien arvojen avulla. Permeabiliteettikertoimien arvot saatiin kirjallisuudesta kanin sarveiskalvon läpäisevyystutkimuksista. Lopullisen mallin muuttujina käytettiin oktanoli-vesijakaantumiskerrointa (logD) pH:ssa 7,4 ja vetysidosatomien kokonaismäärää. Yhtälö oli muotoa log10(permeabiliteettikerroin) = -3,96791 - 0,177842Htotal + 0,311963logD(pH7,4). R2-korrelaatiokerroin oli 0,77 ja Q2-korrelaatiokerroin oli 0,75. Lopullisen mallin hyvyyttä arvioitiin 15 yhdisteen ulkoisella testijoukolla, jolloin ennustettua permeabiliteettia verrattiin kokeelliseen permeabiliteettiin. QSPR-malli arvioitiin myös farmakokineettisen simulaation avulla. Simulaatiossa laskettiin seitsemän yhdisteen kammionestepitoisuudet in vivo vakaassa tilassa käyttäen simulaatioissa QSPR mallilla ennustettuja permeabiliteettikertoimia. Lisäksi laskettiin sarveiskalvon imeytymisen nopeusvakio (Kc) 13 yhdisteelle farmakokineettisen simulaation avulla ja verrattiin tätä lopullisella mallilla ennustettuun permeabiliteettiin. Tulosten perusteella saatiin tilastollisesti hyvä QSPR-malli kuvaamaan sarveiskalvon passiivista permeabiliteettia, jolloin tätä mallia voidaan käyttää lääkekehityksen alkuvaiheessa. QSPR-malli ennusti permeabiliteettikertoimet hyvin, mikä nähtiin vertaamalla mallilla ennustettuja arvoja kokeellisiin tuloksiin. Lisäksi yhdisteiden kammionestepitoisuudet voitiin simuloida käyttäen apuna QSPR-mallilla ennustettuja permeabiliteettikertoimien arvoja.
Resumo:
Peristaltic transport of two fluids occupying the peripheral layer and the core in an elliptic tube is, investigated in elliptic cylindrical co-ordinate system, under long wavelength and low Reynolds number approximations. The effect of peripheral-layer viscosity on the flow rate and the frictional force for a slightly elliptic tube is discussed. The limiting results for the one-fluid model are obtained for different eccentricities of the undisturbed tube cross sections with the same area. As a result of non-uniformity of the peristaltic wave, two different amplitude ratios are defined and the time-averaged flux and mechanical efficiency are studied for different eccentricities. It is observed that the time-averaged flux is not affected significantly by the pressure drop when the eccentricity is large. For the peristaltic waves with same area variation, the pumping seems to improve with the eccentricity.
Resumo:
Arterial walls have a regular and lamellar organization of elastin present as concentric fenestrated networks in the media. In contrast, elastin networks are longitudinally oriented in layers adjacent to the media. In a previous model exploring the biomechanics of arterial elastin, we had proposed a microstructurally motivated strain energy function modeled using orthotropic material symmetry. Using mechanical experiments, we showed that the neo-Hookean term had a dominant contribution to the overall form of the strain energy function. In contrast, invariants corresponding to the two fiber families had smaller contributions. To extend these investigations, we use biaxial force-controlled experiments to quantify regional variations in the anisotropy and nonlinearity of elastin isolated from bovine aortic tissues proximal and distal to the heart. Results from this study show that tissue nonlinearity significantly increases distal to the heart as compared to proximally located regions (). Distally located samples also have a trend for increased anisotropy (), with the circumferential direction stiffer than the longitudinal, as compared to an isotropic and relatively linear response for proximally located elastin samples. These results are consistent with the underlying tissue histology from proximally located samples that had higher optical density (), fiber thickness (), and trend for lower tortuosity () in elastin fibers as compared to the thinner and highly undulating elastin fibers isolated from distally located samples. Our studies suggest that it is important to consider elastin fiber orientations in investigations that use microstructure-based models to describe the contributions of elastin and collagen to arterial mechanics.
Resumo:
Measuring forces applied by multi-cellular organisms is valuable in investigating biomechanics of their locomotion. Several technologies have been developed to measure such forces, for example, strain gauges, micro-machined sensors, and calibrated cantilevers. We introduce an innovative combination of techniques as a high throughput screening tool to assess forces applied by multiple genetic model organisms. First, we fabricated colored Polydimethylsiloxane (PDMS) micropillars where the color enhances contrast making it easier to detect and track pillar displacement driven by the organism. Second, we developed a semiautomated graphical user interface to analyze the images for pillar displacement, thus reducing the analysis time for each animal to minutes. The addition of color reduced the Young's modulus of PDMS. Therefore, the dye-PDMS composite was characterized using Yeoh's hyperelastic model and the pillars were calibrated using a silicon based force sensor. We used our device to measure forces exerted by wild type and mutant Caenorhabditis elegans moving on an agarose surface. Wild type C. elegans exert an average force of similar to 1 mu N on an individual pillar and a total average force of similar to 7.68 mu N. We show that the middle of C. elegans exerts more force than its extremities. We find that C. elegans mutants with defective body wall muscles apply significantly lower force on individual pillars, while mutants defective in sensing externally applied mechanical forces still apply the same average force per pillar compared to wild type animals. Average forces applied per pillar are independent of the length, diameter, or cuticle stiffness of the animal. We also used the device to measure, for the first time, forces applied by Drosophila melanogaster larvae. Peristaltic waves occurred at 0.4Hz applying an average force of similar to 1.58 mu N on a single pillar. Our colored microfluidic device along with its displacement tracking software allows us to measure forces applied by multiple model organisms that crawl or slither to travel through their environment. (C) 2015 AIP Publishing LLC.
Resumo:
Imitating a real tooth and the periodontal supporting tissues, we have established a 2D finite element model and carried out a numerical analysis based on the inhomogeneous and anisotropic (IA) stress-strain relation and strength model of dentin proposed in the preceding Parts I and II, and the conventional homogeneous and isotropic (III) model, respectively. Quite a few cases of loadings for a non-defected and a defected tooth are considered. The numerical results show that the stress level predicted by the IA model is remarkably higher than that by the III model, revealing that the effect of the dentin tubules should be taken into a serious consideration from the viewpoint of biomechanics.
Resumo:
<正> 三、运动关节力学 运动关节(diarthrodial joint)的功能在于使动物能灵巧地运动肢体。译成力学术语就是:传递载荷,吸收冲击、振动,承受相当高的应力,且运动时摩擦系数很小。L.L.Malcom曾精细地测量过牛肱关节的摩擦系数,在正应力1—20kg/cm~2的范围内,动摩擦系数为0.0025—0.0040,而最好的工程材料的摩擦系数为0.01—0.05,整整差一个量级。
Resumo:
"第四届世界生物力学大会"(4~(th)World Congress on Biomechanics)于2002年8月3~11日在加拿大卡尔加里(Calgary,Canada)召开.会议主办单位为卡尔加里大学,参会人数约1 600人.参加会议的主要国家包括:美、英、德、日、加、意、法、中国和中国香港等50余国家和地区.会议交流的论文篇数约为1680篇(含口头报告及墙展).中国中科院力学所、中日友好医院、四川大学、重庆大学等6位学者参加了本次会议.所发表的工作分别涉及细胞与分子生物力学、假肢生物力学、白细胞力学-生物学耦合、血流动力学等方面,其研究工作在整体上符合当前本领域的发展方向,有的工作具有国际竞争性,会议的反响是肯定的.作者在"分子与细胞生物力学"(Molecular and Cellular Biomechanics)分会上做了口头报告和墙报展讲.
Resumo:
《固体力学进展及应用:庆贺李敏华院士90华诞文集》收录了近代固体力学基础理论及其应用领域的重要科技成果和最新进展。作者是在同体力学领域工作多年的资深研究员,他们来自各行各业,有丰富的科研与丁作经验。他们提供的论文在相当程度上反映当前同体力学的发展现状与成就,并能看出发展趋势,对未来研究的课题选择有参考价值。《固体力学进展及应用:庆贺李敏华院士90华诞文集》还收集了李敏华院士的珍贵照片和纪念李敏华院士90华诞的庆贺和回忆文章,具有重要的史料价值。
目录
Resumo:
227 págs.
Resumo:
This is a copy of an article published in the Human gene therapy © 2012 copyright Mary Ann Liebert, Inc.; Human gene therapy is available online at: http://online.liebertpub.com.