993 resultados para Cordeiro - Carcaças
Resumo:
Molecular-level interactions are found to bind iron tetrasulfonated phthalocyanine (FeTsPc) and the polyelectrolyte poly(allylamine hydrochloride) (PAH) in electroactive layer-by-layer (LBL) films. These interactions have been identified by comparing Fourier transform infrared (FTIR) and Raman spectroscopy data from bulk samples of FeTsPc and PAH with those from FeTsPc/PAH LBL films. of particular importance were the SO3- -NH3 interactions that we believe to bind PAH and FeTsPc and the interactions between unprotonated amine groups of PAH and the coordinating metal of the phthalocyanine. The multilayer formation was monitored via UV-vis spectroscopy by measuring the increase in the Q band of FeTsPc at 676 nm. Film thickness estimated with profilometry was ca. I I Angstrom per bilayer for films adsorbed on glass. Reflection absorption infrared spectroscopy (RAIRS) revealed an anisotropy in the LBL film adsorbed on gold with FeTsPc molecules oriented perpendicularly to the substrate plane. Cyclic voltammograms showed reproducible pairs of oxidation-reduction peaks at 1.07 and 0.81 V, respectively, for a 50-bilayer PAH/FeTsPc film at 50 mV/s (vs Ag/Ag+). The peak shape and current dependence on the scan rate suggest that the process is a diffusion controlled charge transport. In the presence of dopamine, the electroactivity of FeTsPc/PAH LBL films vanishes due to a passivation effect. Dopamine activity is not detected either because the interaction between Fe atoms and NH2 groups prevents dopamine molecules from coordinating with the Fe atoms.
Resumo:
A CMOS/SOI circuit to decode Pulse-Width Modulation (PWM) signals is presented as part of a body-implanted neurostimulator for visual prosthesis. Since encoded data is the sole input to the circuit, the decoding technique is based on a novel double-integration concept and does not require low-pass filtering. Non-overlapping control phases are internally derived from the incoming pulses and a fast-settling comparator ensures good discrimination accuracy in the megahertz range. The circuit was integrated on a 2 mum single-metal thin-film CMOS/SOI fabrication process and has an effective area of 2 mm(2). Measured resolution of encoding parameter a is better than 10% at 6 MHz and V-DD = 3.3 V. Idle-mode consumption is 340 LW. Pulses of frequencies up to 15 MHz and alpha = 10% can be discriminated for 2.3 V less than or equal to V-DD less than or equal to 3.3 V. Such an excellent immunity to V-DD deviations meets a design specification with respect to inherent coupling losses on transmitting data and power by means of a transcutaneous link.
Resumo:
Monte Carlo simulation results for pure liquid acetone and water-acetone mixtures calculated in the isothermal and isobaric (NPT) ensemble at T=298K and p=1.0atm are presented. The TIP4P model was used for water and optimized potential for liquid simulation (OPLS) force field parameters used for acetone. The results obtained for the average configurational energy as a function of the mole fraction are in good accord with experimental data. Energy partitioning and co-ordination numbers results calculated for equimolar water-acetone solution are compared to similar data obtained for other water-organic liquid mixtures. These results show an increase in water-water interaction energy and co-ordination numbers when the interaction between water and organic liquid molecules decrease. Distribution functions for pure liquid acetone and water-acetone mixtures are presented. Dipole-dipole angular correlation functions obtained for pure liquid acetone show a predominance of dimers with parallel alignment of dipole moments. Radial distribution functions from water-acetone interaction show characteristic features of hydrogen bonded liquids. Radial and angular distribution functions for water-water correlation calculated in pure water and in equimolar water-acetone mixture are compared, showing very similar features in both systems. (C) 1999 Elsevier B.V. B.V. All rights reserved.
Resumo:
Objective: To determine the prevalence of self-medication in children and adolescents in the municipalities of Limeira and Piracicaba, state of S (a) over tildeo Paulo, and to correlate results with sociodemographic indicators and with the use of health care services (public or private).Methods: Descriptive population-based study of a simple random sample from the two municipalities, comprised of 772 inhabitants from 85 urban census sectors selected through cluster sampling. Inclusion criteria: age <= 18 years; interview with one parent/tutor; consumption of at least one drug in the previous 15 days. Subjects were divided into two study groups according to their pattern of drug use: self-medication (lay advice) and medical prescription. Linear association tests, descriptive analysis of variables and multiple logistic regression tests were carried out to analyze data.Results: the prevalence of self-medication was 56.6%. Mothers (51%) and drugstore employees (20.1%) were most frequently responsible for self-medication. The main groups of self-prescribed drugs were: analgesic/antipyretic and non-hormonal anti-inflammatory drugs (52.9%); drugs acting on the respiratory tract (15.4%) and gastrointestinal drugs (9.6%); and systemic antibiotics (8.6%). The situation that most commonly motivated self-medication were respiratory diseases (17.2%), fever (15%), and headache (14%). Subjects in the age group of 7-18 years (odds ratio = 2.81) and public health care users (odds ratio = 1.52) showed increased risk for self-medication.Conclusions: the prevalence of self-medication in children and adolescents was high, which reinforces the need for public health interventions aiming at preventing this practice.
Resumo:
Purpose : the aim of this study was to evaluate the effect of nozzle angle and tip diameter on the cutting efficiency of an air abrasion system. Materials and Methods: Thirty-six extracted human third molars were air-abraded with the PrepStar microabrasion machine using a handpiece with either 80degrees or 45degrees nozzle angles with 0.38 or 0.48 nun tip orifice diameters. The following parameters were held constant: abrasive particle size (27 mum), air pressure (80 psi), distance (2 mm.) and duration (15 seconds). The cutting efficiency was compared using enamel, dentin and cementum substrates. Width and depth of the cutting patterns were analyzed and measured using scanning electron micrographs. Results: Statistical analysis using three-way ANOVA and Duncan's Multiple Range test revealed that the width of the cuts was significantly greater when the cavities were prepared using the 45degrees nozzle angle. Significantly deeper cavities were produced with the 80degrees nozzle angle. The tip orifice of the nozzle influenced the cutting efficiency in softer substrates, dentin and cementum. Precise removal of hard tissue is best accomplished using the 80degrees angle nozzle tips for all types of tooth surfaces, enamel, dentin and cementum.
Resumo:
Head and neck squamous cell carcinoma is a disease associated with tobacco and alcohol abuse. There is evidence that the oncogenic human papillomavirus (HPV) may also be a risk for upper aerodigestive tract cancers. High-risk HPVs encode two early proteins, E6 and E7, that can bind to p53 and pRb, respectively, and induce its degradation or inactivation. The TP53 gene has a single polymorphism at codon 72 of exon 4 that encodes either arginine (Arg) or proline (Pro). The purpose of this study was to evaluate the role of HPV infection and TP53 polymorphism in head and neck cancer. We analyzed 50 tumors, as well swabs of oral mucosa front 142 control individuals, with a polymerase chain reaction technique. The prevalence of HPV in controls was 10.6% and in cancer specimens 16%. The frequency distribution of genotypes in controls was 50% Arg/Arg, 43% Arg/ Pro and 7% Pro/Pro; in tumors, it was 52% Arg/Arg, 32% Arg/Pro, and 16% Pro/Pro. Contrary to the results of some studies on cervical cancer, no association between any TP53 genotype or allele and the development of head and neck cancer was observed, regardless of HPV status, except for the Pro/Pro genotype, which is associated with the absence of HPV. The arginine allele appears to protect against head and neck cancers. Also, the data showed that HPV infection results in no increased risk of developing head and neck tumors. (C) 2004 Elsevier B.V. All rights reserved.
Resumo:
The habitat of the mycelial saprobic form of Paracoccidio ides brasiliensis, which produces the infectious propagula, has not been determined and has proven difficult for mycologists to describe. The fungus has been rarely isolated from the environment, the disease has a prolonged latency period and no outbreaks have been reported. These facts have precluded the adoption of preventive measures to avoid infection. The confirmation of natural infections in nine-banded armadillos (Dasypus novemcinctus) with P. brasiliensis, in high frequency and wide geographic distribution, has opened new avenues for the study and understanding of its ecology. Armadillos belong to the order Xenarthra, which has existed in South America ever since the Paleocene Era (65 million years ago), when the South American subcontinent was still a detached land, before the consolidation of what is now known as the American continent. on the other hand, strong molecular evidence suggests that P. brasiliensis and other dimorphic pathogenic fungi - such as Blastomyces dermatitidis, Coccidioides immitis and Histoplasma capsulatum - belong to the family Onygenaceae sensu Into (order Onygenales, Ascomycota), which appeared around 150 million years ago.P. brasiliensis ecology and relation to its human host are probably linked to the fungal evolutionary past, especially its long coexistence with and adaptation to animal hosts other than Homo sapiens, of earlier origin. Instead of being a blind alley, the meaning of parasitism for dimorphic pathogenic fungi should be considered as an open two-way avenue, in which the fungus may return to the environment, therefore contributing to preserve its teleomorphic (sexual) and anamorphic (asexual) forms in a defined and protected natural habitat. (c) 2006 Elsevier B.V. All rights reserved.
Resumo:
Ab initio (restricted Hartree-Fock and DFT) and molecular mechanics calculations at MM2 level were performed for N-methylformamide (NMF) molecule and for three dimers in order to investigate the relative stability of the cis and trans conformers. The ab initio calculations show that no intramolecular interaction is relevant for the stability of the conformers explored. The trans conformer is the most stable. The MM calculations revealed that a double H-bonded cyclic cis-cis dimer is the most stable among the studied dimers, followed by a 'linear' H-bonded trans-trans dimer. This 'linear' dimer, however, is prevalent in the liquid phase. (c) 2006 Elsevier B.V. All rights reserved.
Resumo:
Background. The aim of this study was to evaluate the influence of zero-value subtraction on the performance of two laser fluorescence (LF) devices developed to 'detect occlusal caries.Methods. The authors selected 119 permanent molars. Two examiners assessed three areas (cuspal, middle and cervical) of both mesial and distal portions of the buccal surface and one occlusal site using an LF device and an LF pen. For each tooth, the authors subtracted the value measured in the cuspal, middle and cervical areas in the buccal surface from the value measured in the respective occlusal site.Results. The authors observed differences among the readings for both devices in the cuspal, middle and cervical areas in the buccal surface as well as differences for both devices with and without the zero-value subtraction in the occlusal surface. When the authors did not perform the zero-value subtraction, they found statistically significant differences for sensitivity and accuracy far the LF device. When this was done with the LF pen, specificity increased and sensitivity decreased significantly.Conclusions. For the LF device, the zero-value subtraction decreased the sensitivity. For this reason, the authors concluded that clinicians can obtain measures with the LF device effectively without using zero-value subtraction. For the LF pen, however, the absence of the zero-value subtraction changed both the Sensitivity and specificity, and so the authors concluded that clinicians should not eliminate this step from the procedure.Clinical Implications. When using the LF device, clinicians might not need to perform the zero-value subtraction; however, for the LF pen, clinicians should do so.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)