908 resultados para Conical Tube, Aluminium Foam, Impact Energy, Collapse Mode, Finite Element Method
Resumo:
The major aim of this study was to examine the influence of an embedded viscoelastic-plastic layer at different viscosity values on accretionary wedges at subduction zones. To quantify the effects of the layer viscosity, we analysed the wedge geometry, accretion mode, thrust systems and mass transport pattern. Therefore, we developed a numerical 2D 'sandbox' model utilising the Discrete Element Method. Starting with a simple pure Mohr Coulomb sequence, we added an embedded viscoelastic-plastic layer within the brittle, undeformed 'sediment' package. This layer followed Burger's rheology, which simulates the creep behaviour of natural rocks, such as evaporites. This layer got thrusted and folded during the subduction process. The testing of different bulk viscosity values, from 1 × 10**13 to 1 × 10**14 (Pa s), revealed a certain range where an active detachment evolved within the viscoelastic-plastic layer that decoupled the over- and the underlying brittle strata. This mid-level detachment caused the evolution of a frontally accreted wedge above it and a long underthrusted and subsequently basally accreted sequence beneath it. Both sequences were characterised by specific mass transport patterns depending on the used viscosity value. With decreasing bulk viscosities, thrust systems above this weak mid-level detachment became increasingly symmetrical and the particle uplift was reduced, as would be expected for a salt controlled forearc in nature. Simultaneously, antiformal stacking was favoured over hinterland dipping in the lower brittle layer and overturning of the uplifted material increased. Hence, we validated that the viscosity of an embedded detachment strongly influences the whole wedge mechanics, both the respective lower slope and the upper slope duplex, shown by e.g. the mass transport pattern.
Resumo:
A two-dimensional finite element model of current flow in the front surface of a PV cell is presented. In order to validate this model we perform an experimental test. Later, particular attention is paid to the effects of non-uniform illumination in the finger direction which is typical in a linear concentrator system. Fill factor, open circuit voltage and efficiency are shown to decrease with increasing degree of non-uniform illumination. It is shown that these detrimental effects can be mitigated significantly by reoptimization of the number of front surface metallization fingers to suit the degree of non-uniformity. The behavior of current flow in the front surface of a cell operating at open circuit voltage under non-uniform illumination is discussed in detail.
Resumo:
Overhead rigid conductor arrangements for current collection for railway traction have some advantages compared to other, more conventional, energy supply systems. They are simple, robust and easily maintained, not to mention their flexibility as to the required height for installation, which makes them particularly suitable for use in subway infrastructures. Nevertheless, due to the increasing speeds of new vehicles running on modern subway lines, a more efficient design is required for this kind of system. In this paper, the authors present a dynamic analysis of overhead conductor rail systems focused on the design of a new conductor profile with a dynamic behaviour superior to that of the system currently in use. This means that either an increase in running speed can be attained, which at present does not exceed 110 km/h, or an increase in the distance between the rigid catenary supports with the ensuing saving in installation costs. This study has been carried out using simulation techniques. The ANSYS programme has been used for the finite element modelling and the SIMPACK programme for the elastic multibody systems analysis.
Resumo:
An experimental and numerical study of ballistic impacts on steel plates at various temperatures (700ºC, 400ºC and room temperature) has been carried out. The motivation for this work is the blade‐off event that may occur inside a jet engine turbine. However, as a first attempt to understand this complex loading process, a somewhat simpler approach is carried out in the present work. The material used in this study is the FV535 martensitic stainless steel, which is one of the most commonly used materials for turbine casings. Based on material test data, a Modified Johnson‐Cook (MJC) model was calibrated for numerical simulations using the LS‐DYNA explicit finite element code (see Figure 1). To check the mesh size sensitivity, 2D axisymmetric finite element models with three different mesh sizes and configurations were used for the various temperatures. Two fixed meshes with 64 and 128 elements over the 2mm thick plate and one mesh with 32 elements over the thickness with adaptive remeshing were used in the simulations. The formation of adiabatic shear bands in the perforation process has been found critical in order to achieve good results. Adiabatic shear bands are formed by the temperature rise due to the accumulation of plastic strain during impact (see Figure 2). The influence of the thermal softening in the plastic model has hence been analyzed for the room temperature impact tests, where the temperature gradient is highest
Resumo:
La mayoría de las estructuras de hormigón pretensadas construidas en los últimos 50 años han demostrado una excelente durabilidad cuando su construcción se realiza atendiendo las recomendaciones de un buen diseño así como una buena ejecución y puesta en obra de la estructura. Este hecho se debe en gran parte al temor que despierta el fenómeno de la corrosión bajo tensión típico de las armaduras de acero de alta resistencia. Menos atención se ha prestado a la susceptibilidad a la corrosión bajo tensión de los anclajes de postensado, posiblemente debido a que se han reportado pocos casos de fallos catastróficos. El concepto de Tolerancia al Daño y la Mecánica de la Fractura en estructuras de Ingeniería Civil ha empezado a incorporarse recientemente en algunas normas de diseño y cálculo de estructuras metálicas, sin embargo, aún está lejos de ser asimilado y empleado habitualmente por los ingenieros en sus cálculos cuando la ocasión lo requiere. Este desconocimiento de los aspectos relacionados con la Tolerancia al Daño genera importantes gastos de mantenimiento y reparación. En este trabajo se ha estudiado la aplicabilidad de los conceptos de la Mecánica de la Fractura a los componentes de los sistemas de postensado empleados en ingeniería civil, empleándolo para analizar la susceptibilidad de las armaduras activas frente a la corrosión bajo tensiones y a la pérdida de capacidad portante de las cabezas de anclajes de postensado debido a la presencia de defectos. Con este objeto se han combinado tanto técnicas experimentales como numéricas. Los defectos superficiales en los alambres de pretensado no se presentan de manera aislada si no que existe una cierta continuidad en la dirección axial así como un elevado número de defectos. Por este motivo se ha optado por un enfoque estadístico, que es más apropiado que el determinístico. El empleo de modelos estadísticos basados en la teoría de valores extremos ha permitido caracterizar el estado superficial en alambres de 5,2 mm de diámetro. Por otro lado la susceptibilidad del alambre frente a la corrosión bajo tensión ha sido evaluada mediante la realización de una campaña de ensayos de acuerdo con la actual normativa que ha permitido caracterizar estadísticamente su comportamiento. A la vista de los resultados ha sido posible evaluar como los parámetros que definen el estado superficial del alambre pueden determinar la durabilidad de la armadura atendiendo a su resistencia frente a la corrosión bajo tensión, evaluada mediante los ensayos que especifica la normativa. En el caso de las cabezas de anclaje de tendones de pretensado, los defectos se presentan de manera aislada y tienen su origen en marcas, arañazos o picaduras de corrosión que pueden producirse durante el proceso de fabricación, transporte, manipulación o puesta en obra. Dada la naturaleza de los defectos, el enfoque determinístico es más apropiado que el estadístico. La evaluación de la importancia de un defecto en un elemento estructural requiere la estimación de la solicitación local que genera el defecto, que permite conocer si el defecto es crítico o si puede llegar a serlo, si es que progresa con el tiempo (por fatiga, corrosión, una combinación de ambas, etc.). En este trabajo los defectos han sido idealizados como grietas, de manera que el análisis quedara del lado de la seguridad. La evaluación de la solicitación local del defecto ha sido calculada mediante el empleo de modelos de elementos finitos de la cabeza de anclaje que simulan las condiciones de trabajo reales de la cabeza de anclaje durante su vida útil. A partir de estos modelos numéricos se ha analizado la influencia en la carga de rotura del anclaje de diversos factores como la geometría del anclaje, las condiciones del apoyo, el material del anclaje, el tamaño del defecto su forma y su posición. Los resultados del análisis numérico han sido contrastados satisfactoriamente mediante la realización de una campaña experimental de modelos a escala de cabezas de anclaje de Polimetil-metacrilato en los que artificialmente se han introducido defectos de diversos tamaños y en distintas posiciones. ABSTRACT Most of the prestressed concrete structures built in the last 50 years have demonstrated an excellent durability when they are constructed in accordance with the rules of good design, detailing and execution. This is particularly true with respect to the feared stress corrosion cracking, which is typical of high strength prestressing steel wires. Less attention, however, has been paid to the stress corrosion cracking susceptibility of anchorages for steel tendons for prestressing concrete, probably due to the low number of reported failure cases. Damage tolerance and fracture mechanics concepts in civil engineering structures have recently started to be incorporated in some design and calculation rules for metallic structures, however it is still far from being assimilated and used by civil engineers in their calculations on a regular basis. This limited knowledge of the damage tolerance basis could lead to significant repair and maintenance costs. This work deals with the applicability of fracture mechanics and damage tolerance concepts to the components of prestressed systems, which are used in civil engineering. Such concepts have been applied to assess the susceptibility of the prestressing steel wires to stress corrosion cracking and the reduction of load bearing capability of anchorage devices due to the presence of defects. For this purpose a combination of experimental work and numerical techniques have been performed. Surface defects in prestressing steel wires are not shown alone, though a certain degree of continuity in the axial direction exist. A significant number of such defects is also observed. Hence a statistical approach was used, which is assumed to be more appropriate than the deterministic approach. The use of statistical methods based in extreme value theories has allowed the characterising of the surface condition of 5.2 mm-diameter wires. On the other hand the stress corrosion cracking susceptibility of the wire has been assessed by means of an experimental testing program in line with the current regulations, which has allowed statistical characterisasion of their performances against stress corrosion cracking. In the light of the test results, it has been possible to evaluate how the surface condition parameters could determine the durability of the active metal armour regarding to its resistance against stress corrosion cracking assessed by means of the current testing regulations. In the case of anchorage devices for steel tendons for prestressing concrete, the damage is presented as point defects originating from dents, scratches or corrosion pits that could be produced during the manufacturing proccess, transport, handling, assembly or use. Due to the nature of these defects, in this case the deterministic approach is more appropriate than the statistical approach. The assessment of the relevancy of defect in a structural component requires the computation of the stress intensity factors, which in turn allow the evaluation of whether the size defect is critical or could become critical with the progress of time (due to fatigue, corrosion or a combination of both effects). In this work the damage is idealised as tiny cracks, a conservative hypothesis. The stress intensity factors have been calculated by means of finite element models of the anchorage representing the real working conditions during its service life. These numeric models were used to assess the impact of some factors on the rupture load of the anchorage, such the anchorage geometry, material, support conditions, defect size, shape and its location. The results from the numerical analysis have been succesfully correlated against the results of the experimental testing program of scaled models of the anchorages in poly-methil methacrylate in which artificial damage in several sizes and locations were introduced.
Resumo:
El presente trabajo es un estudio teórico – experimental para la implementación de un edificio metálico de cuatro plantas con dispositivos disipadores de energía. Este estudio presenta una técnica para la generación de un registro sísmico artificial, que sea compatible con los espectros de diseño de las normas chilena y española. Este acelerograma se crea con una herramienta computacional denominada SIMQKE. La simulación de la estructura sometida al terremoto artificial se realizará en el programa de elementos finitos SAP200. El trabajo se encuentra dividido en cuatro capítulos, cuyos contenidos son los siguientes. En el capitulo uno, o estado del arte, se revisan las diferentes técnicas de aislamiento sísmico, se describe el dispositivo a utilizar, sus bases teóricas y formulación matemática, se revisan las normas NCh.2745 Of.2003 [12], NCSE-02 [18] y se presenta la técnica para la generación de un registro sintético compatible. El capítulo dos aborda el análisis experimental para un edificio real: una edificación de estructura metálica implementada con disipadores de energía metálicos y que será sometida a tres terremotos de diferente magnitud. El capítulo tres expone los resultados de los desplazamientos medidos para la estructura sin disipadores y con ellos, se presentan los porcentajes de disminución de desplazamientos relativos por planta y por tipo de estructura. Por último, el capítulo cuatro presenta las principales conclusiones y una breve discusión de los resultados. The present work is a theoretical and experimental study for the implementation of a fourstorey building with energy dissipating devices. This study presents a technique for generation an artificial seismic record, which is compatible with the design spectra Chilean and Spanish standards. This accelerogram is created with a computational tool called SIMQKE. The simulation of the structure subjected to artificial earthquake will take place in the finite element program SAP2000. This work is divided into four chapters whose contents are as follows. In chapter one, or state of the art, reviews the different seismic isolation techniques, describes the device used, theoretical and mathematical formulation, NCh2745 Of.2003 [12] and NCSE-02 [18] standards are checked, and presents the technique for generating a synthetic record compatible. Chapter two explains the experimental analysis to a real building: a building of steel structure implemented with metallic energy dissipators and will be submitted to three different earthquakes of magnitude. Chapter three presents the results of measured displacements for the structure without dissipators and with them, the percentages of decline relative displacements per plant and type of structure. Finally, chapter four presents the main conclusions and a brief discussion of the results.
Resumo:
There are many the requirements that modern power converters should fulfill. Most of the applications where these converters are used, demand smaller converters with high efficiency, improved power density and a fast dynamic response. For instance, loads like microprocessors demand aggressive current steps with very high slew rates (100A/mus and higher); besides, during these load steps, the supply voltage of the microprocessor should be kept within tight limits in order to ensure its correct performance. The accomplishment of these requirements is not an easy task; complex solutions like advanced topologies - such as multiphase converters- as well as advanced control strategies are often needed. Besides, it is also necessary to operate the converter at high switching frequencies and to use capacitors with high capacitance and low ESR. Improving the dynamic response of power converters does not rely only on the control strategy but also the power topology should be suited to enable a fast dynamic response. Moreover, in later years, a fast dynamic response does not only mean accomplishing fast load steps but output voltage steps are gaining importance as well. At least, two applications that require fast voltage changes can be named: Low power microprocessors. In these devices, the voltage supply is changed according to the workload and the operating frequency of the microprocessor is changed at the same time. An important reduction in voltage dependent losses can be achieved with such changes. This technique is known as Dynamic Voltage Scaling (DVS). Another application where important energy savings can be achieved by means of changing the supply voltage are Radio Frequency Power Amplifiers. For example, RF architectures based on ‘Envelope Tracking’ and ‘Envelope Elimination and Restoration’ techniques can take advantage of voltage supply modulation and accomplish important energy savings in the power amplifier. However, in order to achieve these efficiency improvements, a power converter with high efficiency and high enough bandwidth (hundreds of kHz or even tens of MHz) is necessary in order to ensure an adequate supply voltage. The main objective of this Thesis is to improve the dynamic response of DC-DC converters from the point of view of the power topology. And the term dynamic response refers both to the load steps and the voltage steps; it is also interesting to modulate the output voltage of the converter with a specific bandwidth. In order to accomplish this, the question of what is it that limits the dynamic response of power converters should be answered. Analyzing this question leads to the conclusion that the dynamic response is limited by the power topology and specifically, by the filter inductance of the converter which is found in series between the input and the output of the converter. The series inductance is the one that determines the gain of the converter and provides the regulation capability. Although the energy stored in the filter inductance enables the regulation and the capability of filtering the output voltage, it imposes a limitation which is the concern of this Thesis. The series inductance stores energy and prevents the current from changing in a fast way, limiting the slew rate of the current through this inductor. Different solutions are proposed in the literature in order to reduce the limit imposed by the filter inductor. Many publications proposing new topologies and improvements to known topologies can be found in the literature. Also, complex control strategies are proposed with the objective of improving the dynamic response in power converters. In the proposed topologies, the energy stored in the series inductor is reduced; examples of these topologies are Multiphase converters, Buck converter operating at very high frequency or adding a low impedance path in parallel with the series inductance. Control techniques proposed in the literature, focus on adjusting the output voltage as fast as allowed by the power stage; examples of these control techniques are: hysteresis control, V 2 control, and minimum time control. In some of the proposed topologies, a reduction in the value of the series inductance is achieved and with this, the energy stored in this magnetic element is reduced; less stored energy means a faster dynamic response. However, in some cases (as in the high frequency Buck converter), the dynamic response is improved at the cost of worsening the efficiency. In this Thesis, a drastic solution is proposed: to completely eliminate the series inductance of the converter. This is a more radical solution when compared to those proposed in the literature. If the series inductance is eliminated, the regulation capability of the converter is limited which can make it difficult to use the topology in one-converter solutions; however, this topology is suitable for power architectures where the energy conversion is done by more than one converter. When the series inductor is eliminated from the converter, the current slew rate is no longer limited and it can be said that the dynamic response of the converter is independent from the switching frequency. This is the main advantage of eliminating the series inductor. The main objective, is to propose an energy conversion strategy that is done without series inductance. Without series inductance, no energy is stored between the input and the output of the converter and the dynamic response would be instantaneous if all the devices were ideal. If the energy transfer from the input to the output of the converter is done instantaneously when a load step occurs, conceptually it would not be necessary to store energy at the output of the converter (no output capacitor COUT would be needed) and if the input source is ideal, the input capacitor CIN would not be necessary. This last feature (no CIN with ideal VIN) is common to all power converters. However, when the concept is actually implemented, parasitic inductances such as leakage inductance of the transformer and the parasitic inductance of the PCB, cannot be avoided because they are inherent to the implementation of the converter. These parasitic elements do not affect significantly to the proposed concept. In this Thesis, it is proposed to operate the converter without series inductance in order to improve the dynamic response of the converter; however, on the other side, the continuous regulation capability of the converter is lost. It is said continuous because, as it will be explained throughout the Thesis, it is indeed possible to achieve discrete regulation; a converter without filter inductance and without energy stored in the magnetic element, is capable to achieve a limited number of output voltages. The changes between these output voltage levels are achieved in a fast way. The proposed energy conversion strategy is implemented by means of a multiphase converter where the coupling of the phases is done by discrete two-winding transformers instead of coupledinductors since transformers are, ideally, no energy storing elements. This idea is the main contribution of this Thesis. The feasibility of this energy conversion strategy is first analyzed and then verified by simulation and by the implementation of experimental prototypes. Once the strategy is proved valid, different options to implement the magnetic structure are analyzed. Three different discrete transformer arrangements are studied and implemented. A converter based on this energy conversion strategy would be designed with a different approach than the one used to design classic converters since an additional design degree of freedom is available. The switching frequency can be chosen according to the design specifications without penalizing the dynamic response or the efficiency. Low operating frequencies can be chosen in order to favor the efficiency; on the other hand, high operating frequencies (MHz) can be chosen in order to favor the size of the converter. For this reason, a particular design procedure is proposed for the ‘inductorless’ conversion strategy. Finally, applications where the features of the proposed conversion strategy (high efficiency with fast dynamic response) are advantageus, are proposed. For example, in two-stage power architectures where a high efficiency converter is needed as the first stage and there is a second stage that provides the fine regulation. Another example are RF power amplifiers where the voltage is modulated following an envelope reference in order to save power; in this application, a high efficiency converter, capable of achieving fast voltage steps is required. The main contributions of this Thesis are the following: The proposal of a conversion strategy that is done, ideally, without storing energy in the magnetic element. The validation and the implementation of the proposed energy conversion strategy. The study of different magnetic structures based on discrete transformers for the implementation of the proposed energy conversion strategy. To elaborate and validate a design procedure. To identify and validate applications for the proposed energy conversion strategy. It is important to remark that this work is done in collaboration with Intel. The particular features of the proposed conversion strategy enable the possibility of solving the problems related to microprocessor powering in a different way. For example, the high efficiency achieved with the proposed conversion strategy enables it as a good candidate to be used for power conditioning, as a first stage in a two-stage power architecture for powering microprocessors.
Resumo:
Performing three-dimensional pin-by-pin full core calculations based on an improved solution of the multi-group diffusion equation is an affordable option nowadays to compute accurate local safety parameters for light water reactors. Since a transport approximation is solved, appropriate correction factors, such as interface discontinuity factors, are required to nearly reproduce the fully heterogeneous transport solution. Calculating exact pin-by-pin discontinuity factors requires the knowledge of the heterogeneous neutron flux distribution, which depends on the boundary conditions of the pin-cell as well as the local variables along the nuclear reactor operation. As a consequence, it is impractical to compute them for each possible configuration; however, inaccurate correction factors are one major source of error in core analysis when using multi-group diffusion theory. An alternative to generate accurate pin-by-pin interface discontinuity factors is to build a functional-fitting that allows incorporating the environment dependence in the computed values. This paper suggests a methodology to consider the neighborhood effect based on the Analytic Coarse-Mesh Finite Difference method for the multi-group diffusion equation. It has been applied to both definitions of interface discontinuity factors, the one based on the Generalized Equivalence Theory and the one based on Black-Box Homogenization, and for different few energy groups structures. Conclusions are drawn over the optimal functional-fitting and demonstrative results are obtained with the multi-group pin-by-pin diffusion code COBAYA3 for representative PWR configurations.
Resumo:
A mathematical model for finite strain elastoplastic consolidation of fully saturated soil media is implemented into a finite element program. The algorithmic treatment of finite strain elastoplasticity for the solid phase is based on multiplicative decomposition and is coupled with the algorithm for fluid flow via the Kirchhoff pore water pressure. A two-field mixed finite element formulation is employed in which the nodal solid displacements and the nodal pore water pressures are coupled via the linear momentum and mass balance equations. The constitutive model for the solid phase is represented by modified Cam—Clay theory formulated in the Kirchhoff principal stress space, and return mapping is carried out in the strain space defined by the invariants of the elastic logarithmic principal stretches. The constitutive model for fluid flow is represented by a generalized Darcy's law formulated with respect to the current configuration. The finite element model is fully amenable to exact linearization. Numerical examples with and without finite deformation effects are presented to demonstrate the impact of geometric nonlinearity on the predicted responses. The paper concludes with an assessment of the performance of the finite element consolidation model with respect to accuracy and numerical stability.
Resumo:
La evaluación de la seguridad de estructuras antiguas de fábrica es un problema abierto.El material es heterogéneo y anisótropo, el estado previo de tensiones difícil de conocer y las condiciones de contorno inciertas. A comienzos de los años 50 se demostró que el análisis límite era aplicable a este tipo de estructuras, considerándose desde entonces como una herramienta adecuada. En los casos en los que no se produce deslizamiento la aplicación de los teoremas del análisis límite estándar constituye una herramienta formidable por su simplicidad y robustez. No es necesario conocer el estado real de tensiones. Basta con encontrar cualquier solución de equilibrio, y que satisfaga las condiciones de límite del material, en la seguridad de que su carga será igual o inferior a la carga real de inicio de colapso. Además esta carga de inicio de colapso es única (teorema de la unicidad) y se puede obtener como el óptimo de uno cualquiera entre un par de programas matemáticos convexos duales. Sin embargo, cuando puedan existir mecanismos de inicio de colapso que impliquen deslizamientos, cualquier solución debe satisfacer tanto las restricciones estáticas como las cinemáticas, así como un tipo especial de restricciones disyuntivas que ligan las anteriores y que pueden plantearse como de complementariedad. En este último caso no está asegurada la existencia de una solución única, por lo que es necesaria la búsqueda de otros métodos para tratar la incertidumbre asociada a su multiplicidad. En los últimos años, la investigación se ha centrado en la búsqueda de un mínimo absoluto por debajo del cual el colapso sea imposible. Este método es fácil de plantear desde el punto de vista matemático, pero intratable computacionalmente, debido a las restricciones de complementariedad 0 y z 0 que no son ni convexas ni suaves. El problema de decisión resultante es de complejidad computacional No determinista Polinomial (NP)- completo y el problema de optimización global NP-difícil. A pesar de ello, obtener una solución (sin garantía de exito) es un problema asequible. La presente tesis propone resolver el problema mediante Programación Lineal Secuencial, aprovechando las especiales características de las restricciones de complementariedad, que escritas en forma bilineal son del tipo y z = 0; y 0; z 0 , y aprovechando que el error de complementariedad (en forma bilineal) es una función de penalización exacta. Pero cuando se trata de encontrar la peor solución, el problema de optimización global equivalente es intratable (NP-difícil). Además, en tanto no se demuestre la existencia de un principio de máximo o mínimo, existe la duda de que el esfuerzo empleado en aproximar este mínimo esté justificado. En el capítulo 5, se propone hallar la distribución de frecuencias del factor de carga, para todas las soluciones de inicio de colapso posibles, sobre un sencillo ejemplo. Para ello, se realiza un muestreo de soluciones mediante el método de Monte Carlo, utilizando como contraste un método exacto de computación de politopos. El objetivo final es plantear hasta que punto está justificada la busqueda del mínimo absoluto y proponer un método alternativo de evaluación de la seguridad basado en probabilidades. Las distribuciones de frecuencias, de los factores de carga correspondientes a las soluciones de inicio de colapso obtenidas para el caso estudiado, muestran que tanto el valor máximo como el mínimo de los factores de carga son muy infrecuentes, y tanto más, cuanto más perfecto y contínuo es el contacto. Los resultados obtenidos confirman el interés de desarrollar nuevos métodos probabilistas. En el capítulo 6, se propone un método de este tipo basado en la obtención de múltiples soluciones, desde puntos de partida aleatorios y calificando los resultados mediante la Estadística de Orden. El propósito es determinar la probabilidad de inicio de colapso para cada solución.El método se aplica (de acuerdo a la reducción de expectativas propuesta por la Optimización Ordinal) para obtener una solución que se encuentre en un porcentaje determinado de las peores. Finalmente, en el capítulo 7, se proponen métodos híbridos, incorporando metaheurísticas, para los casos en que la búsqueda del mínimo global esté justificada. Abstract Safety assessment of the historic masonry structures is an open problem. The material is heterogeneous and anisotropic, the previous state of stress is hard to know and the boundary conditions are uncertain. In the early 50's it was proven that limit analysis was applicable to this kind of structures, being considered a suitable tool since then. In cases where no slip occurs, the application of the standard limit analysis theorems constitutes an excellent tool due to its simplicity and robustness. It is enough find any equilibrium solution which satisfy the limit constraints of the material. As we are certain that this load will be equal to or less than the actual load of the onset of collapse, it is not necessary to know the actual stresses state. Furthermore this load for the onset of collapse is unique (uniqueness theorem), and it can be obtained as the optimal from any of two mathematical convex duals programs However, if the mechanisms of the onset of collapse involve sliding, any solution must satisfy both static and kinematic constraints, and also a special kind of disjunctive constraints linking the previous ones, which can be formulated as complementarity constraints. In the latter case, it is not guaranted the existence of a single solution, so it is necessary to look for other ways to treat the uncertainty associated with its multiplicity. In recent years, research has been focused on finding an absolute minimum below which collapse is impossible. This method is easy to set from a mathematical point of view, but computationally intractable. This is due to the complementarity constraints 0 y z 0 , which are neither convex nor smooth. The computational complexity of the resulting decision problem is "Not-deterministic Polynomialcomplete" (NP-complete), and the corresponding global optimization problem is NP-hard. However, obtaining a solution (success is not guaranteed) is an affordable problem. This thesis proposes solve that problem through Successive Linear Programming: taking advantage of the special characteristics of complementarity constraints, which written in bilinear form are y z = 0; y 0; z 0 ; and taking advantage of the fact that the complementarity error (bilinear form) is an exact penalty function. But when it comes to finding the worst solution, the (equivalent) global optimization problem is intractable (NP-hard). Furthermore, until a minimum or maximum principle is not demonstrated, it is questionable that the effort expended in approximating this minimum is justified. XIV In chapter 5, it is proposed find the frequency distribution of the load factor, for all possible solutions of the onset of collapse, on a simple example. For this purpose, a Monte Carlo sampling of solutions is performed using a contrast method "exact computation of polytopes". The ultimate goal is to determine to which extent the search of the global minimum is justified, and to propose an alternative approach to safety assessment based on probabilities. The frequency distributions for the case study show that both the maximum and the minimum load factors are very infrequent, especially when the contact gets more perfect and more continuous. The results indicates the interest of developing new probabilistic methods. In Chapter 6, is proposed a method based on multiple solutions obtained from random starting points, and qualifying the results through Order Statistics. The purpose is to determine the probability for each solution of the onset of collapse. The method is applied (according to expectations reduction given by the Ordinal Optimization) to obtain a solution that is in a certain percentage of the worst. Finally, in Chapter 7, hybrid methods incorporating metaheuristics are proposed for cases in which the search for the global minimum is justified.
Resumo:
The mechanical response under compression of LiF single crystal micropillars oriented in the [111] direction was studied. Micropillars of different diameter (in the range 1–5 lm) were obtained by etching the matrix in directionally-solidified NaCl–LiF and KCl–LiF eutectic compounds. Selected micropillars were exposed to high-energy Ga+ ions to ascertain the effect of ion irradiation on the mechanical response. Ion irradiation led to an increase of approximately 30% in the yield strength and the maximum compressive strength but no effect of the micropillar diameter on flow stress was found in either the as-grown or the ion irradiated pillars. The dominant deformation micromechanisms were analyzed by means of crystal plasticity finite element simulations of the compression test, which explained the strong effect of micropillar misorientation on the mechanical response. Finally, the lack of size effect on the flow stress was discussed to the light of previous studies in LiF and other materials which show high lattice resistance to dislocation motion.
Resumo:
The pattern of damage localization and fracture under uniaxial and biaxial tension was studied in glass–fiber nonwoven felts. The analyses were carried out within the framework of the finite-element simulation of plain and notched specimens in which the microstructure of the felt, made up of fiber bundles connected at the cross point through an organic binder, was explicitly represented. Following previous experimental observations, fracture by interbundle decohesion and energy dissipation by frictional sliding between the bundles were included in the model. It was found that the failure path in these materials was controlled by the maximum applied normal stress, regardless of the loading path, and that the failure locus under biaxial tension was well represented by the von Mises failure criteria. The notch sensitivity of the nonwoven felts was limited and the presence of a notch did not modify the failure path.
Resumo:
Global linear instability theory is concerned with the temporal or spatial development of small-amplitude perturbations superposed upon laminar steady or time-periodic three-dimensional flows, which are inhomogeneous in two(and periodic in one)or all three spatial directions.After a brief exposition of the theory,some recent advances are reported. First, results are presented on the implementation of a Jacobian-free Newton–Krylov time-stepping method into a standard finite-volume aerodynamic code to obtain global linear instability results in flows of industrial interest. Second, connections are sought between established and more-modern approaches for structure identification in flows, such as proper orthogonal decomposition and Koopman modes analysis (dynamic mode decomposition), and the possibility to connect solutions of the eigenvalue problem obtained by matrix formation or time-stepping with those delivered by dynamic mode decomposition, residual algorithm, and proper orthogonal decomposition analysis is highlighted in the laminar regime; turbulent and three-dimensional flows are identified as open areas for future research. Finally, a new stable very-high-order finite-difference method is implemented for the spatial discretization of the operators describing the spatial biglobal eigenvalue problem, parabolized stability equation three-dimensional analysis, and the triglobal eigenvalue problem; it is shown that, combined with sparse matrix treatment, all these problems may now be solved on standard desktop computers