953 resultados para Concurrent Radiotherapy
Resumo:
Aim - To use Monte Carlo (MC) together with voxel phantoms to analyze the tissue heterogeneity effect in the dose distributions and equivalent uniform dose (EUD) for (125)I prostate implants. Background - Dose distribution calculations in low dose-rate brachytherapy are based on the dose deposition around a single source in a water phantom. This formalism does not take into account tissue heterogeneities, interseed attenuation, or finite patient dimensions effects. Tissue composition is especially important due to the photoelectric effect. Materials and Methods - The computed tomographies (CT) of two patients with prostate cancer were used to create voxel phantoms for the MC simulations. An elemental composition and density were assigned to each structure. Densities of the prostate, vesicles, rectum and bladder were determined through the CT electronic densities of 100 patients. The same simulations were performed considering the same phantom as pure water. Results were compared via dose-volume histograms and EUD for the prostate and rectum. Results - The mean absorbed doses presented deviations of 3.3-4.0% for the prostate and of 2.3-4.9% for the rectum, when comparing calculations in water with calculations in the heterogeneous phantom. In the calculations in water, the prostate D 90 was overestimated by 2.8-3.9% and the rectum D 0.1cc resulted in dose differences of 6-8%. The EUD resulted in an overestimation of 3.5-3.7% for the prostate and of 7.7-8.3% for the rectum. Conclusions - The deposited dose was consistently overestimated for the simulation in water. In order to increase the accuracy in the determination of dose distributions, especially around the rectum, the introduction of the model-based algorithms is recommended.
Resumo:
Classical lock-based concurrency control does not scale with current and foreseen multi-core architectures, opening space for alternative concurrency control mechanisms. The concept of transactions executing concurrently in isolation with an underlying mechanism maintaining a consistent system state was already explored in fault-tolerant and distributed systems, and is currently being explored by transactional memory, this time being used to manage concurrent memory access. In this paper we discuss the use of Software Transactional Memory (STM), and how Ada can provide support for it. Furthermore, we draft a general programming interface to transactional memory, supporting future implementations of STM oriented to real-time systems.
Resumo:
The recent trends of chip architectures with higher number of heterogeneous cores, and non-uniform memory/non-coherent caches, brings renewed attention to the use of Software Transactional Memory (STM) as a fundamental building block for developing parallel applications. Nevertheless, although STM promises to ease concurrent and parallel software development, it relies on the possibility of aborting conflicting transactions to maintain data consistency, which impacts on the responsiveness and timing guarantees required by embedded real-time systems. In these systems, contention delays must be (efficiently) limited so that the response times of tasks executing transactions are upper-bounded and task sets can be feasibly scheduled. In this paper we assess the use of STM in the development of embedded real-time software, defending that the amount of contention can be reduced if read-only transactions access recent consistent data snapshots, progressing in a wait-free manner. We show how the required number of versions of a shared object can be calculated for a set of tasks. We also outline an algorithm to manage conflicts between update transactions that prevents starvation.
Resumo:
Most current-generation Wireless Sensor Network (WSN) nodes are equipped with multiple sensors of various types, and therefore support for multi-tasking and multiple concurrent applications is becoming increasingly common. This trend has been fostering the design of WSNs allowing several concurrent users to deploy applications with dissimilar requirements. In this paper, we extend the advantages of a holistic programming scheme by designing a novel compiler-assisted scheduling approach (called REIS) able to identify and eliminate redundancies across applications. To achieve this useful high-level optimization, we model each user application as a linear sequence of executable instructions. We show how well-known string-matching algorithms such as the Longest Common Subsequence (LCS) and the Shortest Common Super-sequence (SCS) can be used to produce an optimal merged monolithic sequence of the deployed applications that takes into account embedded scheduling information. We show that our approach can help in achieving about 60% average energy savings in processor usage compared to the normal execution of concurrent applications.
Resumo:
Several projects in the recent past have aimed at promoting Wireless Sensor Networks as an infrastructure technology, where several independent users can submit applications that execute concurrently across the network. Concurrent multiple applications cause significant energy-usage overhead on sensor nodes, that cannot be eliminated by traditional schemes optimized for single-application scenarios. In this paper, we outline two main optimization techniques for reducing power consumption across applications. First, we describe a compiler based approach that identifies redundant sensing requests across applications and eliminates those. Second, we cluster the radio transmissions together by concatenating packets from independent applications based on Rate-Harmonized Scheduling.
Resumo:
OBJECTIVE To analyze evidence of the validity and reliability of a Brazilian Portuguese version of the Quality of Care Scale from the perspective of people with physical and intellectual disabilities.METHODS There were 162 people with physical disabilities and 156 with intellectual disabilities from Porto Alegre and metropolitan region, who participated in the study in 2008. Classical psychometrics was used to independently analyze the two samples. Hypotheses for evidence of criterion validity (concurrent type) were tested with the Mann-Whitney test for non-normal distributions. Principal components analysis was used to explore factorial models. Evidence of reliability was calculated with Cronbach alpha for the scales and subscales. Test-retest reliability was analyzed for individuals with intellectual disabilities through intra-class correlation coefficient and the Willcoxon test.RESULTS The principal components in the group with physical disabilities replicated the original model presented as a solution to the international project data. Evidence of discriminant validity and test-retest reliability was found.CONCLUSIONS The transcultural factor model found within the international sample project seems appropriate for the samples investigated in this study, especially the physical disabilities group. Depression, pain, satisfaction with life and disability may play a mediating role in the evaluation of quality of care. Additional research is needed to add to evidence of the validity of the instruments.
Fisioterapia no tratamento das mulheres Angolanas com cancro da mama no Centro Nacional de Oncologia
Resumo:
Mestrado em Fisioterapia
Resumo:
Mestrado em Radioterapia - Área de especialização: Dosimetria Clínica
Resumo:
Trabalho apresentado no âmbito do Mestrado em Engenharia Informática, como requisito parcial para obtenção do grau de Mestre em Engenharia Informática
Resumo:
Dissertação apresentada na Faculdade de Ciências e Tecnologia da Universidade Nova de Lisboa para a obtenção do Grau de Mestre em Engenharia Informática
Resumo:
This paper presents a low-cost scaled model of a silo for drying and airing cereal grains. It allows the control and monitor of several parameters associated to the silo's operation, through a remote accessible infrastructure. The scaled model consists of a 2.50 m wide × 2.10 m long plant with all control and monitor capacities provided by micro-Web servers. An application running on the micro-Web servers enables storing all parameters in a data basis for later analysis. The implemented model aims to support a remote experimentation facility for technological education, research-oriented tutorials, and industrial applications. Given the low-cost requirement, this remote facility can be easily replicated in other institutions to support a network of remote labs, which encompasses the concurrent access of several users (e.g. students).
Resumo:
The concurrent use of herbs and/or nutritional supplements with psychoactive effect and prescription medications is common among college students. College students are a particularly vulnerable population, for they are under less social/familiar surveillance and seek greater independence, as well as under greater intellectual effort, stress, anxiety and depression, which predispose them to a higher consumption of psychoactive substances. Herbs, vitamins, and other dietary supplements may influence the effects of prescription and nonprescription drugs leading to adverse consequences, by increasing the potential for interactions. However, documented interactions between herbal medicinal products and prescribed drugs are rare. Objective: determine the prevalence of concomitant use of psychoactive substances among healthcare students in the Lisbon School of Health Technology, Portugal, in order to assess the risk of potential herb-drug interactions.
Resumo:
Trabalho apresentado no âmbito do Mestrado em Engenharia Informática, como requisito parcial para obtenção do grau de Mestre em Engenharia Informática
Resumo:
Dissertação apresentada na Faculdade de Ciências e Tecnologia da Universidade Nova de Lisboa para a obtenção do Grau de Mestre em Engenharia Informática
Resumo:
Resumo - O avanço tecnológico e científico no campo da Medicina tem favorecido a aplicação das radiações ionizantes nas áreas da Medicina Nuclear, Radiologia, Radioterapia e noutras especialidades relacionadas com a medicina de intervenção, como a Cardiologia. As Organizações de Saúde, com profissionais com risco de exposição a radiações ionizantes, são responsáveis, legislativamente, por assegurar a sua vigilância. Certificando a observação controlada das doses de exposição, os profissionais são monitorizados com dosímetros individuais e submetidos a vigilância médica. As leituras de dosímetria individual destes profissionais, originam por vezes, nos próprios, desconfianças e incertezas quanto aos valores medidos. Objectivo: avaliar o grau de confiança dos profissionais de saúde, expostos a radiações ionizantes, no sistema de monitorização individual. Metodologia: estudo observacional do tipo analítico- transversal, por questionário. Amostra de 190 Técnicos de Diagnóstico e Terapêutica de Cardiopneumologia, Medicina Nuclear, Radiologia, Radioterapia, expostos a radiações ionizantes, que exercem a sua actividade profissional em hospitais do concelho de Lisboa. Resultados: 51,1% dos Técnicos de Diagnóstico e Terapêutica não confiam nas leituras dos dosímetros, não se determinou uma relação estatisticamente significativa entre essa confiança, o tipo de dosímetro e a empresa que realiza as leituras. A confiança é maior nos que exercem em Organizações de Saúde públicas. 40,2% das Organizações de Saúde apresentam plano de vigilância médica, constatando-se uma falta de conformidade entre os Técnicos de Diagnóstico e Terapêutica, nalguns hospitais, relativamente à existência desse plano no respectivo hospital. A margem de erro associado ao estudo é de 5,09%, com um nível de confiança de 95%. -----------Abstract - The technological and scientific advances in the field of medicine has encouraged the application of ionizing radiation with a considerable positive contribution in the areas of Nuclear Medicine, Radiology, Radiotherapy and other specialties related to medical intervention like Cardiology. The Health Organizations that arise the risk of occupational exposure to ionizing radiation and is their responsibility to ensure monitoring, according the law. To ensure the monitoring of controlled doses of exposure, the exposed works use an individual dosimeter and undergo medical supervision. The individual dosimetry readings of health-care professionals, is sometimes questionable for themselves, arising distrust and uncertainty about the values measured. Objective: evaluate the degree of confidence of health professionals, exposed to radiation, on the system of individual monitoring. Methods: Observational study of cross-type analysis by questionnaire. Sample of 190 of technologists of Cardiopneumology, Nuclear Medicine, Radiology, Radiotherapy, exposed to ionizing radiation, which work in hospitals on the region of Lisbon. Results: 51.1% of technologists does not rely on the readings of their dosimeters, and wasn’t determined a statistically significant relationship between this trust, the type of dosimeter and the company that makes the readings(s) of their(s) dosimeter(s). The confidence in the readings is higher in public Health Organizations. 40.2% of the Health Organizations have medical monitoring plan and there is a disagreement between technologists, in some hospitals, relatively to the existence of this plan in their hospital. It was estimated that the u