852 resultados para Complementary marker
Resumo:
We have observed that vitamin A levels, deficient in patients with severe disease, returned to normal post lungtransplant independent of oral supplementation or pancreatic sufficiency. We hypothesised that vitamin A is associated with disease severity and the inflammatory marker C-related peptide (CRP). Data from RCH paediatric and TPCH adult CF clinic subjects (ns138 CF, 138 control, aged 5–56 yr), who had participated in a study of bone mineral density (BMD) in which vitamins A, E, D, and CRP, height, weight and lung function had been measured was used. Groups were compared using t- or Wilcoxon-tests, and predictors of vitamin A examined usingmultiple regression. Vitamin A was lower in CF subjects (1.23"0.5 vs. 1.80"0.6 mmolyl, P-0.0001), increasingwith age in paediatric subjects but to a lesser extent in the CF group (Ps0.0007). CRP was correlated with age (rs0.6, P-0.0001). FEV1% predicted (FEV) (57.93"23.0 vs. 70.63"21.8, Ps0.0014), weight z-score (WTZ) (y0.76"0.9 vs. y0.12"1.0, Ps0.0002), lumbar spine BMD z-score (y1.08"1.3 vs. y0.50"1.2, Ps0.009) were lower, and CRP higher (median 7.0, IQR 2–4 vs. median 1.0, IQR 1–3 mgy l, P-0.0001) in vitamin A insufficient CF subjects (61 insufficient vs. 71 sufficient). In all subjects, control status (P-0.0001), WTZ (Ps0.02), vitamin E (Ps 0.0003), CRP (Ps0.001), 1,25 dihydroxy vitamin D (1,25 vit. D) (Ps0.0007), and child, adolescent or adult grouping (all P-0.0001) were predictive of vitamin A. In the CF group, CRP (Ps0.01), Vitamin E (P-0.0001) and 1.25 vit. D (Ps 0.006), but not FEV, were predictive. The normal increase in vitamin A with age was not observed in CF subjects, who had lower levels at any age. This failure of normal increase in vitamin A had a consistent association with increasingCRP , supportingthe hypothesis that increased inflammation may result in increased vitamin A consumption.
Resumo:
The first derivative of pressure over time (dP/dt) is a marker of left ventricular (LV) systolic function that can be assessed during cardiac catheterization and echocardiography. Radial artery dP/dt (Radial-dP/dt) has been proposed as a possible marker of LV systolic function (Nichols & O’Rourke, McDonald’s Blood Flow in Arteries) and we sought to test this hypothesis. Methods:We compared simultaneously recorded RadialdP/ dt (by high-fidelity tonometry) with LV-dP/dt (by highfidelity catheter and echocardiography parameters analogous to LV-dP/dt) in patients without aortic valve disease. In study 1, beat to beat Radial-dP/dt and LV-dP/dt were recorded at rest and during supine exercise in 12 males (aged 61±12 years) undergoing cardiac catheterization. In study 2, 2D-echocardiography and Radial-dP/dt were recorded in 59 patients (43 men; aged 64±10 years) at baseline and peak dobutamine-induced stress. Three measures at the basal septum were taken as being analogous to LV-dP/dt: (1) peak systolic strain rate, (2) strain rate (SR-dP/dt), and (3) tissue velocity during isovolumic contraction. Results: Study 1; there was a significant difference between resting LV-dP/dt (1461±383 mmHg/s) and Radial-dP/dt (1182±319 mmHg/s; P < 0.001), and a poor, but statistically significant, correlation between the variables (R2 = 0.006; P < 0.001) due to the high number of data points compared (n = 681). Similar results were observed during exercise. Study 2; there was a moderate association between baseline Radial-dP/dt and SRdP/ dt (R2 =−0.17; P < 0.01), but no significant relationship between Radial-dP/dt and all other echocardiographic measures analogous to LV-dP/dt at rest or peak stress (P > 0.05). Conclusion: The radial pressurewaveform is not a reliable marker of LV contractility.
Resumo:
Simple design formulas for designing ultra wideband (UWB) antennas in the form of complementary planar monopoles are described and their validity is tested using full electromagnetic wave simulations and measurements. Assuming dielectric substrate with relative permittivity of 10.2, the designed antennas feature a small size of 13 mmtimes26 mm. They exhibit a 10 dB return loss bandwidth from 3 to more than 15 GHz accompanied by near omnidirectional characteristics and good radiation efficiency throughout this band