971 resultados para Combining Different Representations


Relevância:

20.00% 20.00%

Publicador:

Resumo:

There has been no comparison of fluoride (F) intake by pre-school children receiving more traditional sources of systemic F. The aim of this study was to estimate the dietary F intake by children receiving F from artificially fluoridated water (AFW-Brazil, 0.6-0.8 mg F/L), naturally fluoridated water (NFW-Brazil, 0.6-0.9 mg F/L), fluoridated salt (FS-Peru, 180-200 mg F/Kg), and fluoridated milk (FM-Peru, 0.25 mg F). Children (n = 21-26) aged 4-6 yrs old participated in each community. A non-fluoridated community (NoF) was evaluated as the control population. Dietary F intake was monitored by the ""duplicate plate"" method, with different constituents (water, other beverages, and solids). F was analyzed with an ion-selective electrode. Data were tested by Kruskall-Wallis and Dunn`s tests (p < 0.05). Mean (+/- SD) F intake (mg/Kg b.w./day) was 0.04 +/- 0.01(b), 0.06 +/- 0.02(a,b), 0.05 +/- 0.02(a,b), 0.06 +/- 0.01(a), and 0.01 +/- 0.00(c) for AFW/NFW/FS/FM/NoF, respectively. The main dietary contributors for AFW/NFW and FS/FM/NoF were water and solids, respectively. The results indicate that the dietary F intake must be considered before a systemic method of fluoridation is implemented.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To evaluate the influence of dentifrice pH and fluoride (F) concentration on F uptake by plaque and nails, two sets of 5-to 6-year-old children were randomly allocated into four groups, according to the type of dentifrice they had been using for 1 year: (1) experimental liquid dentifrice (ELD), 1,100 ppm F, pH 7.0; (2) ELD, 1,100 ppm F, pH 4.5; (3) ELD, 550 ppm F, pH 4.5, and (4) commercial toothpaste, 1,100 ppm F, pH 7.0. In one set of children, nails were clipped. In the second, plaque samples were collected 1 h after the last use of dentifrice. F concentration in plaque and nails was analyzed. Plaque F concentration was significantly lower in group 4 than in groups 1-3. Nail F concentration was significantly higher in group 4, and significantly lower in group 3, than in group 1 or 2. Plaque F uptake was influenced significantly by dentifrice consistency and nonsignificantly by pH and F concentration. Reduction of dentifrice pH did not affect nail F concentration. Copyright (C) 2009 S. Karger AG, Basel

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aims of this study were: (1) to correlate surface (SH) and cross-sectional hardness (CSH) with microradiographic parameters of artificial enamel lesions; (2) to compare lesions prepared by different protocols. Fifty bovine enamel specimens were allocated by stratified randomisation according to their initial SH values to five groups and lesions produced by different methods: MC gel (methylcellulose gel/lactic acid, pH 4.6, 14 days); PA gel (polyacrylic acid/lactic acid/hydroxyapatite, pH 4.8, 16 h); MHDP (undersaturated lactate buffer/methyl diphosphonate, pH 5.0, 6 days); buffer (undersaturated acetate buffer/fluoride, pH 5.0, 16 h), and pH cycling (7 days). SH of the lesions (SH(1)) was measured. The specimens were longitudinally sectioned and transverse microradiography (TMR) and CSH measured at 10- to 220-mu m depth from the surface. Overall, there was a medium correlation but non-linear and variable relationship between mineral content and root CSH. root SH(1) was weakly to moderately correlated with surface layer properties, weakly correlated with lesion depth but uncorrelated with integrated mineral loss. MHDP lesions showed the highest subsurface mineral loss, followed by pH cycling, buffer, PA gel and MC gel lesions. The conclusions were: (1) CSH, as an alternative to TMR, does not estimate mineral content very accurately, but gives information about mechanical properties of lesions; (2) SH should not be used to analyse lesions; (3) artificial caries lesions produced by the protocols differ, especially considering the method of analysis. Copyright (C) 2009 S. Karger AG, Basel

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This in vitro study evaluated the effect of a prolonged erosive pH cycling on the superficial microhardness change (SMHC) and the erosive wear of different restorative materials. Eighty enamel specimens with prepared cavities of 1.5 x 1.5 mm were randomly divided into eight groups according to the restorative materials used for the fillings (RMGI - resin-modified glass-ionomer, CGI - conventional glass-ionomer, CR- composite resin, A - amalgam) and immersion media used (ERO - erosive medium or SAL - artificial saliva). During 35 days, half of the specimens were immersed in a cola drink (ERO), for 5 min, three times a day, and they remained in SAL between the erosive cycles. The other half of the specimens was immersed in SAL only, for the entire experimental period (control). Data were tested for significant differences by anova and Tukey`s tests (P < 0.05). Scanning electron microscopy images were made to illustrate the enamel erosive wear and restorative materials alterations. The mean SMHC (%) and mean erosive wear (mu m) of the materials were: RMGI-ERO (30/0.5); CGI-ERO (37/0.5); CR-ERO (-0.3/0.3); A-ERO (-4/0.3); RMGI-SAL (4/0.4); CGI-SAL (-6/0.4); CR-SAL (-3/0.2) and A-SAL (2/0.4). Scanning electron microscopy images showed pronounced enamel erosive wear on groups submitted to erosive pH cycling when compared with groups maintained in saliva. In conclusion, the prolonged pH cycling promoted significantly higher alterations (SMHC and erosive wear) on the glass-ionomer cements than the CR and amalgam.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This in vitro study evaluated the effect of erosive pH cycling on the percentage of surface micro-hardness change (%SMHC) and wear of different restorative materials and bovine enamel restored with these materials. Eighty enamel specimens were randomly divided into eight groups according to the restorative materials and immersion media used: GI/GV-resin-modifled glass-ionomer, GII/GVI-conventional glass-ionomer, GIII/GVII-resin composite and GIV/GVIII-amalgam. Over a period of seven days, groups GI to GIV were immersed in a cola drink (ERO) for 5 minutes, 3x/day and kept in artificial saliva between erosive cycles. Groups GV to GVIII were immersed in artificial saliva (SAL) throughout the entire experimental period (control). Data were tested for significant differences using ANOVA and Tukey`s tests (p < 0.05). For %SMHC, considering the restorative materials, no significant differences were detected among the materials and immersion media. Mean wear was higher for the resin modified glass ionomer cement when compared to conventional cement, but those materials did not significantly differ from the others. For enamel analyses, erosive pH cycling promoted higher wear and %SMHC compared to saliva. There were no significant differences in wear and %SMHC of enamel around the different restorative materials, regardless of the distance from the restorative material (50, 150 or 300 mu m). In conclusion, there were only subtle differences among the materials, and these differences were not able to protect the surrounding enamel from erosion.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This in situ/ex vivo study assessed the effect of different concentrations of fluoride in dentifrices on dentin subjected to erosion or to erosion plus abrasion. Ten volunteers took part in this crossover and double-blind study performed in 3 phases (7 days). They wore acrylic palatal appliances containing 4 bovine dentin blocks divided in two rows: erosion and erosion plus abrasion. The blocks were subjected to erosion by immersion ex vivo in a cola drink (60 s, pH 2.6) 4 times daily. During this step, the volunteers brushed their teeth with one of three dentifrices D (5,000 ppm F, NaF, silica); C (1,100 ppm F, NaF, silica) and placebo (22 ppm F, silica). Then, the respective dentifrice slurry (1: 3) was dripped on dentin surfaces. While no further treatment was performed in one row, the other row was brushed using an electric toothbrush for 30 s ex vivo. The appliances were replaced in the mouth and the volunteers rinsed with water. Dentin loss was determined by profilometry and analyzed by 2-way ANOVA/Bonferroni test (alpha = 0.05). Dentin loss after erosive-abrasive wear was significantly greater than after erosion alone. Wear was significantly higher for the placebo than for the D and C dentifrices, which were not significantly different from each other. It can be concluded that the presence of fluoride concentrations around 1,100 ppm in dentifrices is important to reduce dentin wear by erosion and erosion + abrasion, but the protective effect does not increase with fluoride concentration. Copyright (C) 2008 S. Karger AG, Basel.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

There has been no comparison between fluoride concentrations in urine and nails of children exposed to different sources of systemic fluoride. The aim of this study was to compare the relationship between fluoride intake with urinary fluoride excretion and fluoride concentrations in fingernails and toenails of children receiving fluoride from artificially fluoridated water (0.6-0.8 mg F/L, n = 25), naturally fluoridated water (0.6-0.9 mg F/L, n = 21), fluoridated salt (180-200 mg F/Kg, n = 26), and fluoridated milk (0.25 mg F, n = 25). A control population was included (no systemic fluoride, n = 24). Fluoride intake from diet and dentifrice, urinary fluoride excretion, and fluoride concentrations in fingernails/toenails were evaluated. Fluoride was analyzed with an ion-selective electrode. Urinary fluoride excretion in the control community was significantly lower when compared with that in the fluoridated cities, except for the naturally fluoridated community. However, the same pattern was not as evident for nails. Both urinary fluoride output and fluoride concentrations in fingernails/toenails were significantly correlated to total fluoride intake. However, the correlation coefficients for fluoride intake and urinary fluoride output were lower (r = 0.28, p < 0.01) than those observed for fingernails/toenails (r = 0.36, p < 0.001), suggesting that nails might be slightly better indicators of fluoride intake at the individual level.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: The aim of this study was to evaluate the biofilm dissolution and cleaning ability of different irrigant solutions on intraorally infected dentin. Methods: One hundred twenty bovine dentin specimens were infected intraorally by using a removable orthodontic device. Thirty samples were used for each irrigant solution: 2% chlorhexidine and 1%, 2.5%, and 5.25% sodium hypochlorite (NaOCl). The solutions were used for 5, 15, and 30 minutes and at 2 experimental volumes, 500 mu L and 1 mL. The samples were stained by using acridine orange dye before and after the experiments and evaluated by using a confocal microscope. The percentage of biofilm, isolated cells, and noncolonized dentin was measured by using a grid system. Differences in the reduction or increase of the studied parameters were assessed by using nonparametric methods (P < .05). Results: The higher values of biofilm dissolution and noncolonized dentin were found in the 30-minute NaOCl group and in the 5-minute and 15-minute groups of 5.25% NaOCL. The use of 2% chlorhexidine solution did not improve the biofilm dissolution or increase the cleaning of the dentin in comparison with the NaOCl solutions (P < .05). Conclusions: Two percent chlorhexidine does not dissolve the biofilms. Thirty minutes of NaOCl are necessary to have higher values of biofilm dissolution and to increase the cleaning of the dentin independently of the concentration in comparison with the 5-minute and 15-minute contact times. (J Endod 2011;37:1134-1138)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study evaluated the radiopacity of Portland cement associated with the following radiopacifying agents: bismuth oxide, zinc oxide, lead oxide, bismuth subnitrate, bismuth carbonate, barium sulfate, iodoform, calcium tungstate, and zirconium oxide. A ratio of 20% radiopacifier and 80% white Portland cement by weight was used for analysis. Pure Portland cement and dentin served as controls. Cement/radiopacifier and dentin disc-shaped specimens were fabricated, and radiopacity testing was performed according to the ISO 6876/2001 standard for dental root sealing materials. Using Insight occlusal films, the specimens were radiographed near to a graduated aluminum stepwedge varying from 2 to 16 mm in thickness. The radiographs were digitized and radiopacity compared with the aluminum stepwedge using Digora software (Orion Corporation Soredex, Helsinki, Finland). The radiographic density data were converted into mmAl and analyzed statistically by analysis of variance and Tukey-Kramer test (alpha = 0.05). The radiopacity of pure Portland cement was significantly lower (p < 0.05) than that of dentin, whereas all cement/radiopacifier mixtures were significantly more radiopaque than dentin and Portland cement alone (p < 0.05). Portland cement/bismuth oxide and Portland cement/lead oxide presented the highest radiopacity values and differed significantly from the other materials (p < 0.05), whereas Portland cement/zinc oxide presented the lowest radiopacity values of all mixtures (p < 0.05). All tested substances presented higher radiopacity than that of dentin and may potentially be added to the Portland cement as radiopacifying agents. However, the possible interference of the radiopacifiers with the setting chemistry, biocompatibility, and physical properties of the Portland cement should be further investigated before any clinical recommendation can be done. (J Endod 2009,35:737-740)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The temperature of different refrigerant sprays (Endo-Ice, Endo-Frost, Coolermatic and Sprayon Contact and Tuner Cleaner) used as pulpal tests were evaluated in vitro. A thermocouple placed inside the pulp chamber of a maxillary central incisor was used to register the temperature changes when the refrigerant sprays were applied with a cotton swab, for 10 s. Results indicate that Endo-Ice and Endo-Frost presented the lowest temperatures among the refrigerant sprays tested. Temperatures measured inside the pulp chamber, however, were statistically similar in all groups.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective. The presence of arsenic in various types of mineral trioxide aggregate (MTA) and Portland cements were evaluated to verify if they comply with the ISO-recommended limit for water-based cements of 2 mg arsenic/kg material. Study design. An amount of 5 mL of hydrochloric acid was added to 2 g each of MTA and Portland cement to be analyzed. After 15 minutes, the material was filtered and the volume of supernatant was diluted with reagent-grade water up to 40 mL. Atomic absorption spectrophotometry readings were performed in triplicate. Results. The following mean values were obtained: CPM (Egeo, Buenos Aires, Argentina) 11.06 mg/kg; CPM sealer (Egeo) 10.30 mg/kg; MTA- Obtura (Angelus, Londrina, PR, Brazil) 0.39 mg/kg; Experimental MTA: 10.30 mg/kg; White MTA- Angelus (Angelus) 1.03 mg/kg; Gray MTA- Angelus (Angelus) 5.91 mg/kg; ProRoot-MTA (Dentsply/Tulsa Dental Specialties, Tulsa, OK) 5.25 mg/kg; Gray Portland cement (Votorantim Cimentos, Cubatao, SP, Brazil): 34.27 mg/kg; and White Portland cement (Cimento Rio Branco, Rio de Janeiro, RJ, Brazil) 0.52 mg/kg. Conclusion. All tested materials presented arsenic in their composition. The form of arsenic was not analyzed nor the toxicity of the arsenic found. Only MTA- Obtura, White MTA- Angelus, and White Portland cement presented arsenic levels below the limit set in the ISO 9917-1 standard. (Oral Surg Oral Med Oral Pathol Oral Radiol Endod 2008; 106: 909-913)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To evaluate the tensile bond strength of indirect composites repaired with different surface treatments and direct composites. Methods: 180 specimens were prepared with Targis, belleGlass HP and Sculpture indirect composites, light-activated and post-cured according to the manufacturers` recommendations. The specimens were stored in distilled water for 24 hours at 37 degrees C. The bonding surfaces were prepared with air abrasion, hydrofluoric acid or hydrofluoric acid followed by a neutralizing solution. All the treated surfaces were subject to the application of a silane and a bonding agent before the repair procedures with Tetric Ceram and Tetric Flow for the Targis specimens, Herculite XRV and Revolution for the belleGlass HP specimens and Sculp-It and Flow-It for Sculpture specimens. The tensile bond strength tests were carried out using a universal testing machine at cross-head speed of 0.5 mm/minute. The type of fracture was observed under a light microscope at x40 magnification. Data were analyzed by a two-way ANOVA and Tukey`s post-hoc tests (P<0.05). Results: Targis showed a statistically higher repair bond strength than belleGlass HP and Sculpture, which were not significantly different from each other. Air abrasion increased the repair bond strength of belleGlass HP and Sculpture. For Targis, all the surface treatments resulted in similar repair bond strength. The different viscosity of repair composites did not affect the repair of indirect composites. Fractured surfaces showed mostly adhesive failures, mainly with hydrofluoric acid treatment.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: To evaluate, through the application of different dentin bonding systems, the influence of wetness on shear bond strength in enamel. Methods: This study evaluated three etch-and-rinse adhesive systems (Scotchbond MP [used with and without primer]; Singlebond; and Prime&Bond 2.1) and two self-etching adhesive systems (Clearfil SE Bond; and Xeno IV). Flat bovine enamel surfaces were either air-dried for 30 seconds or blotted with absorbent paper after acid-etching for the conventional bonding agents or before the application of self-etching bonding agents. The resin composite EsthetX was bonded to flat surfaces that had been treated with one of the adhesives, following the manufacturer`s instructions. After being stored in water at 37 degrees C for one week, bonded specimens were broken in shear. Data were evaluated with two-way analysis of variance (ANOVA) and Student-Newman-Keuls tests (alpha=0.05). For comparing each condition individually, regardless of the adhesive or wetness condition, a one-way ANOVA and a Student-Newman-Keuls test (alpha=0.05) were applied. Results: The two-way ANOVA showed significant differences among adhesive systems. An interaction effect was also observed (p < 0.05), but wetness did not influence shear bond strength (p=0.98). The one-way ANOVA showed that the all-in-one adhesive was the only material influenced by the presence of water at the enamel`s surface. Conclusion: The all-in-one adhesive behaved differently depending on whether the enamel surface was dry or wet.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective. This study compared the coronal bacterial leakage of root canals obturated by different techniques and with different lengths of obturation. Study design. The canals of palatal roots of 160 maxillary molars were instrumented and divided into different groups according to the obturation technique used (lateral condensation, Microseal system, Touch `n Heat + Ultrafil system, or Tagger`s hybrid technique) and the length of obturation (5 mm or 10 mm). The roots were impermeabilized, sterilized in ethylene oxide, and mounted on a device for evaluation of the bacterial leakage. Results. Tagger`s hybrid technique produced a statistically greater number of specimens with coronal leakage than the other techniques. There was no statistically significant difference between the lateral condensation, Touch `n Heat + Ultrafil, and Microseal groups. Root canals with 10 mm of obturation produced a statistically significantly smaller number of specimens with leakage than root canals with 5 mm of obturation. Conclusion. Tagger`s hybrid technique produced a greater number of specimens with coronal leakage than the other techniques, and a greater number of root canals with 5 mm of obturation leaked than root canals with 10 mm of obturation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: The aim of this study was to evaluate the performances of observers in diagnosing proximal caries in digital images obtained from digital bitewing radiographs using two scanners and four digital cameras in Joint Photographic Experts Group (JPEG) and tagged image file format (TIFF) files, and comparing them with the original conventional radiographs. Method: In total, 56 extracted teeth were radiographed with Kodak Insight film (Eastman Kodak, Rochester, NY) in a Kaycor Yoshida X-ray device (Kaycor X-707;Yoshida Dental Manufacturing Co., Tokyo, Japan) operating at 70 kV and 7 mA with an exposure time of 0.40 s. The radiographs were obtained and scanned by CanonScan D646U (Canon USA Inc., Newport News, VA) and Genius ColorPage HR7X (KYE Systems Corp. America, Doral, FL) scanners, and by Canon Powershot G2 (Canon USA Inc.), Canon RebelXT (Canon USA Inc.), Nikon Coolpix 8700 (Nikon Inc., Melville, NY), and Nikon D70s (Nikon Inc.) digital cameras in JPEG and TIFF formats. Three observers evaluated the images. The teeth were then observed under the microscope in polarized light for the verification of the presence and depth of the carious lesions. Results: The probability of no diagnosis ranged from 1.34% (Insight film) to 52.83% (CanonScan/JPEG). The sensitivity ranged from 0.24 (Canon RebelXT/JPEG) to 0.53 (Insight film), the specificity ranged from 0.93 (Nikon Coolpix/JPEG, Canon Powershot/TIFF, Canon RebelXT/JPEG and TIFF) to 0.97 (CanonScan/TIFF and JPEG) and the accuracy ranged from 0.82 (Canon RebelXT/JPEG) to 0.91 (CanonScan/JPEG). Conclusion: The carious lesion diagnosis did not change in either of the file formats (JPEG and TIFF) in which the images were saved for any of the equipment used. Only the CanonScan scanner did not have adequate performance in radiography digitalization for caries diagnosis and it is not recommended for this purpose. Dentomaxillofacial Radiology (2011) 40, 338-343. doi: 10.1259/dmfr/67185962