914 resultados para Cold Shock


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Whether or not there are molecular differences, at the intra- and extracellular level, between aortic dilatation in patients with bicuspid (BAV) and those with a tricuspid aortic valve (TAV) has remained controversial for years. We have performed 2-dimensional gel electrophoresis and mass spectrometry coupled with dephosphorylation and phosphostaining experiments to reveal and define protein alterations and the high abundant structural phosphoproteins in BAV compared to TAV aortic aneurysm samples. 2-D gel patterns showed a high correlation in protein expression between BAV and TAV specimens (n=10). Few proteins showed significant differences, among those a phosphorylated form of heat shock protein (HSP) 27 with significantly lower expression in BAV compared to TAV aortic samples (p=0.02). The phosphoprotein tracing revealed four different phosphoproteins including Rho GDP dissociation inhibitor 1, calponin 3, myosin regulatory light chain 2 and four differentially phosphorylated forms of HSP27. Levels of total HSP27 and dually phosphorylated HSP27 (S78/S82) were investigated in an extended patient cohort (n=15) using ELISA. Total HSP27 was significantly lower in BAV compared to TAV patients (p=0.03), with no correlation in levels of phospho-HSP27 (S78/S82) (p=0.4). Western blots analysis showed a trend towards lower levels of phospho-HSP27 (S78) in BAV patients (p=0.07). Immunohistochemical analysis revealed that differences in HSP27 occur in the cytoplasma of VSMC's and not extracellularly. Alterations in HSP27 may give early evidence for intracellular differences in aortic aneurysm of patients with BAV and TAV. Whether HSP27 and the defined phosphoproteins have a specific role in BAV associated aortic dilatation remains to be elucidated.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We examined whether experimental pneumococcal meningitis induced the 72-kd heat shock protein (HSP72), a sensitive marker of neuronal stress in other models of central nervous system (CNS) injury. Brain injury was characterized by vasculitis, cerebritis, and abscess formation in the cortex of infected animals. The extent of these changes correlated with the size of the inoculum (P less than 0.003) and with pathophysiologic parameters of disease severity, i.e., cerebrospinal fluid (CSF) lactate (r = 0.61, P less than 0.0001) and CSF glucose concentrations (r = -0.55, P less than 0.0001). Despite the presence of numerous cortical regions having morphologic evidence of injury, HSP72 was not detected in most animals. When present, only rare neurons were HSP72 positive. Western blot analysis of brain samples confirmed the paucity of HSP72 induction. The lack of neuronal HSP72 expression in this model suggests that at least some of the events leading to neuronal injury in meningitis are unique, when compared with CNS diseases associated with HSP72 induction.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE OF REVIEW: This review will discuss the rationale and clinical utility of percutaneous left ventricular assist devices in the management of patients with cardiogenic shock. RECENT FINDINGS: Left ventricular assist devices maintain partial or total circulatory support in case of severe left ventricular failure. Currently, two percutaneous left ventricular assist devices are available for clinical use: the TandemHeart and the Impella Recover LP system. Compared with the intraaortic balloon pump, the TandemHeart has been shown to significantly reduce preload and to augment cardiac output. In a randomized comparison between the TandemHeart and intraaortic balloon pump support in patients with cardiogenic shock, the improved cardiac index afforded by the left ventricular assist device resulted in a more rapid decrease in serum lactate and improved renal function. There were, however, no significant differences with respect to 30-day mortality, and complications including limb ischemia and severe bleeding were more frequent with left ventricular assist devices than intraaortic balloon pump support. SUMMARY: The advent of percutaneous left ventricular assist devices constitutes an important advance in the management of patients with severe cardiogenic shock and may serve as bridge to recovery or heart transplantation in carefully selected patients. While improvement of hemodynamic parameters appears promising, it remains to be determined whether this benefit translates into improved clinical outcome.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Cardiogenic shock complicates up to 7% of ST-segment elevation myocardial infarctions and 2.5% of non-ST-segment elevation myocardial infarctions, with an associated mortality of 50% to 70%. Primary cardiac pump failure is followed by secondary vital organ hypoperfusion and subsequent activation of various cascade pathways, resulting in a downward spiral leading to multiple organ failure and, ultimately, death. Immediate restoration of cardiac output by means of percutaneous ventricular assist devices restores hemodynamic -stability and is an important advance in the management of patients with severe left ventricular dysfunction and cardiogenic shock. This article reviews available evidence supporting the use of percutaneous ventricular assist devices in patients suffering from cardiogenic shock.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE OF REVIEW: To describe the effects of arginine vasopressin other than its vasoconstrictive and antidiuretic potential in vasodilatory shock. RECENT FINDINGS: Arginine vasopressin influences substrate metabolism by stimulation of hepatic glucose release, gluconeogenesis, ureogenesis and fatty acid esterification. Although arginine vasopressin is a secretagogue of different hormones, only prolactin increases during arginine vasopressin therapy. Plasmatic and cellular coagulation are affected by arginine vasopressin, resulting in thrombocyte aggregation. Therefore, platelet count typically decreases following arginine vasopressin infusion in critically ill patients. In addition, arginine vasopressin reduces bile flow and may increase bilirubin concentrations. Despite its potential to decrease serum sodium, no change in electrolytes was observed in critically ill patients receiving arginine vasopressin. Although arginine vasopressin is an endogenous antipyretic, body temperature is not decreased by central venous arginine vasopressin infusion. In addition, arginine vasopressin modulates immune function through V1 receptors. Compared with norepinephrine, arginine vasopressin may have protective effects on endothelial function. Net arginine vasopressin effects on gastrointestinal motility seem to be inhibitory and are dose dependent. SUMMARY: Except for its antidiuretic and vasoconstrictive actions, the effects of arginine vasopressin in patients with vasodilatory shock have so far only been partially examined. Potential influences of arginine vasopressin on metabolism and immune, liver and mitochondrial function remain to be assessed in future studies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Historical stained glass in Calumet and Laurium revealed the complex structures of these industrial communities. Creating an Industrial Archaeology-focused approach, I examined stained glass as material culture. Sacred glass revealed ethnic and religious values of a congregation through the style, iconography, and quality of the glasswork. Residential glass showed how owners represented themselves within cultural settings by meeting social expectations. Commercial glass indicated community status of owners through discreet and artistic shows of wealth and taste. Corporate glass displayed prosperity and belonging through the superior quality and cost of the glasswork. Viewing stained glass as material culture opened new methods of looking at both stained glass and industrial communities. Findings from my research can teach the public about the importance of preserving and conserving stained glass, and that can lead to greater public appreciation for the material culture found within these industrial communities.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Ischemia/reperfusion injury leads to activation of graft endothelial cells (EC), boosting antigraft immunity and impeding tolerance induction. We hypothesized that the complement inhibitor and EC-protectant dextran sulfate (DXS, MW 5000) facilitates long-term graft survival induced by non-depleting anti-CD4 mAb (RIB 5/2). Hearts from DA donor rats were heterotopically transplanted into Lewis recipients treated with RIB 5/2 (20 mg/kg, days-1,0,1,2,3; i.p.) with or without DXS (grafts perfused with 25 mg, recipients treated i.v. with 25 mg/kg on days 1,3 and 12.5 mg/kg on days 5,7,9,11,13,15). Cold graft ischemia time was 20 min or 12 h. Median survival time (MST) was comparable between RIB 5/2 and RIB 5/2+DXS-treated recipients in the 20-min group with >175-day graft survival. In the 12-h group RIB 5/2 only led to chronic rejection (MST = 49.5 days) with elevated alloantibody response, whereas RIB 5/2+DXS induced long-term survival (MST >100 days, p < 0.05) with upregulation of genes related to transplantation tolerance. Analysis of the 12-h group treated with RIB 5/2+DXS at 1-day posttransplantation revealed reduced EC activation, complement deposition and inflammatory cell infiltration. In summary, DXS attenuates I/R-induced acute graft injury and facilitates long-term survival in this clinically relevant transplant model.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Increasing prices for fuel with depletion and instability in foreign oil imports has driven the importance for using alternative and renewable fuels. The alternative fuels such as ethanol, methanol, butyl alcohol, and natural gas are of interest to be used to relieve some of the dependence on oil for transportation. The renewable fuel, ethanol which is made from the sugars of corn, has been used widely in fuel for vehicles in the United States because of its unique qualities. As with any renewable fuel, ethanol has many advantages but also has disadvantages. Cold startability of engines is one area of concern when using ethanol blended fuel. This research was focused on the cold startability of snowmobiles at ambient temperatures of 20 °F, 0 °F, and -20 °F. The tests were performed in a modified 48 foot refrigerated trailer which was retrofitted for the purpose of cold-start tests. Pure gasoline (E0) was used as a baseline test. A splash blended ethanol and gasoline mixture (E15, 15% ethanol and 85% gasoline by volume) was then tested and compared to the E0 fuel. Four different types of snowmobiles were used for the testing including a Yamaha FX Nytro RTX four-stroke, Ski-doo MX Z TNT 600 E-TEC direct injected two stroke, Polaris 800 Rush semi-direct injected two-stroke, and an Arctic Cat F570 carbureted two-stroke. All of the snowmobiles operate on open loop systems which means there was no compensation for the change in fuel properties. Emissions were sampled using a Sensors Inc. Semtech DS five gas emissions analyzer and engine data was recoded using AIM Racing Data Power EVO3 Pro and EVO4 systems. The recorded raw exhaust emissions included carbon monoxide (CO), carbon dioxide (CO2), total hydrocarbons (THC), and oxygen (O2). To help explain the trends in the emissions data, engine parameters were also recorded. The EVO equipment was installed on each vehicle to record the following parameters: engine speed, exhaust gas temperature, head temperature, coolant temperature, and test cell air temperature. At least three consistent tests to ensure repeatability were taken at each fuel and temperature combination so a total of 18 valid tests were taken on each snowmobile. The snowmobiles were run at operating temperature to clear any excess fuel in the engine crankcase before each cold-start test. The trends from switching from E0 to E15 were different for each snowmobile as they all employ different engine technologies. The Yamaha snowmobile (four-stroke EFI) achieved higher levels of CO2 with lower CO and THC emissions on E15. Engine speeds were fairly consistent between fuels but the average engine speeds were increased as the temperatures decreased. The average exhaust gas temperature increased from 1.3-1.8% for the E15 compared to E0 due to enleanment. For the Ski-doo snowmobile (direct injected two-stroke) only slight differences were noted when switching from E0 to E15. This could possibly be due to the lean of stoichiometric operation of the engine at idle. The CO2 emissions decreased slightly at 20 °F and 0 °F for E15 fuel with a small difference at -20 °F. Almost no change in CO or THC emissions was noted for all temperatures. The only significant difference in the engine data observed was the exhaust gas temperature which decreased with E15. The Polaris snowmobile (semi-direct injected two-stroke) had similar raw exhaust emissions for each of the two fuels. This was probably due to changing a resistor when using E15 which changed the fuel map for an ethanol mixture (E10 vs. E0). This snowmobile operates at a rich condition which caused the engine to emit higher values of CO than CO2 along with exceeding the THC analyzer range at idle. The engine parameters and emissions did not increase or decrease significantly with decreasing temperature. The average idle engine speed did increase as the ambient temperature decreased. The Arctic Cat snowmobile (carbureted two-stroke) was equipped with a choke lever to assist cold-starts. The choke was operated in the same manor for both fuels. Lower levels of CO emissions with E15 fuel were observed yet the THC emissions exceeded the analyzer range. The engine had a slightly lower speed with E15.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

AIMS: Data on moderately cold water immersion and occurrence of arrhythmias in chronic heart failure (CHF) patients are scarce. METHODS AND RESULTS: We examined 22 male patients, 12 with CHF [mean age 59 years, ejection fraction (EF) 32%, NYHA class II] and 10 patients with stable coronary artery disease (CAD) without CHF (mean age 65 years, EF 52%). Haemodynamic effects of water immersion and swimming in warm (32 degrees C) and moderately cold (22 degrees C) water were measured using an inert gas rebreathing method. The occurrence of arrhythmias during water activities was compared with those measured during a 24 h ECG recording. Rate pressure product during water immersion up to the chest was significantly higher in moderately cold (P = 0.043 in CHF, P = 0.028 in CAD patients) compared with warm water, but not during swimming. Rate pressure product reached 14200 in CAD and 12 400 in CHF patients during swimming. Changes in cardiac index (increase by 5-15%) and oxygen consumption (increase up to 20%) were of similar magnitude in moderately cold and warm water. Premature ventricular contractions (PVCs) increased significantly in moderately cold water from 15 +/- 41 to 76 +/- 163 beats per 30 min in CHF (P = 0.013) but not in CAD patients (20 +/- 33 vs. 42 +/- 125 beats per 30 min, P = 0.480). No ventricular tachycardia was noted. CONCLUSION: Patients with compensated CHF tolerate water immersion and swimming in moderately cold water well. However, the increase in PVCs raises concerns about the potential danger of high-grade ventricular arrhythmias.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Implantable Cardioverter Defibrillator (ICD) implantation is the only established therapy for primary or secondary prevention of sudden cardiac death in patients with Hypertrophic Cardiomyopathy (HCM). Ineffectiveness of shock therapy for the termination of potentially fatal ventricular arrhythmias in ICD recipients is rare in the presence of appropriate arrhythmia detection by the device. We report the case of a 48-year-old woman with HCM and a single chamber ICD, who received five inefficient high-energy (35 Joules) shocks for the termination of an appropriately detected episode of Ventricular Tachycardia (VT). The episode was safely terminated with a subsequent application of Antitachycardia Pacing (ATP) by the device. At the following ICD control, an acceptable defibrillation threshold was detected.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Left ventricular assist devices were developed to support the function of a failing left ventricle. Owing to recent technological improvements, ventricular assist devices can be placed by percutaneous implantation techniques, which offer the advantage of fast implantation in the setting of acute left ventricular failure. This article reviews the growing evidence supporting the clinical use of left ventricular assist devices. Specifically, we discuss the use of left ventricular assist devices in patients with cardiogenic shock, in patients with acute ST-elevation myocardial infarction without shock, and during high-risk percutaneous coronary interventions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Sialic-acid-binding immunoglobulin-like lectin (Siglec) 9 mediates death signals in neutrophils. The objective of this study was to determine the heterogeneity of neutrophil death responses in septic shock patients and to analyze whether these ex vivo data are related to the severity and outcome of septic shock. In this prospective cohort study, blood samples of patients with septic shock (n = 26) in a medical-surgical intensive care unit (ICU) were taken within 24 h of starting the treatment of septic shock (phase A), after circulatory stabilization (phase B), and 10 days after admission or at ICU discharge if earlier (phase C). Neutrophil death was quantified in the presence and absence of an agonistic anti-Siglec-9 antibody after 24 h ex vivo. In phase A, two distinct patterns of Siglec-9-mediated neutrophil death were observed: resistance to neutrophil death (n = 14; Siglec-9 nonresponders) and increased neutrophil death (n = 12; Siglec-9 responders) after Siglec-9 ligation compared with neutrophils from normal donors. Experiments using a pharmacological pan-caspase-inhibitor provided evidence for caspase-independent neutrophil death in Siglec-9 responders upon Siglec-9 ligation. There were no differences between Siglec-9 responders and nonresponders in length of ICU or hospital stay of survivors or severity of organ dysfunction. Taken together, septic shock patients exhibit different ex vivo death responses of blood neutrophils after Siglec-9 ligation early in shock. Both the resistance and the increased susceptibility to Siglec-9-mediated neutrophil death tend to normalize within 72 h after shock. Further studies are required to understand the role of Siglec-9-mediated neutrophil death in septic shock.