881 resultados para Closed Source
Resumo:
This is one of a series of photographs accompanying a press release by the New York Trade School announcing the development and demonstration of a new technique in closed-circuit TV. In this work student Joseph Germer asks a question about the demonstration. Original caption reads, "Microphone goes to student Joseph Germer, who asks a question about another phase of the demonstration." Black and white photograph with caption.
Resumo:
One of a series of photographs accompanying a press release by the New York Trade School announcing the development and demonstration of a new technique in closed-circuit TV. Student Dennis Mahoney serves as one of the cameramen as William C. H. Meyers of the Automotive Department performs the demonstration. Black and white photograph.
Resumo:
magine if you will the near perfect statefunded program. Yes, I know, such words sound like an oxymoron, given the track record of both state and federally-funded programs, past, present and undoubtedly in the future. Indeed, such words sound almost mythological in light of recent attempts by the federal government to spend us out of the current recession with still doubtful results (so far, a record deficit). Yet, you’re an imaginative individual and can put aside petty political persiflage and visualize such a program. Not only does this program do precisely what it said it would do, it does it so surprisingly well that, as a taxpayer, you’re completely astonished and whole-heartedly impressed.
Resumo:
This work presents closed-form solutions to Lucasís (2000) generalequilibrium expression for the welfare costs of ináation, as well as to the di§erence between the general-equlibrium measure and Baileyís (1956) partial-equilibrium measure. In Lucasís original work only numerical solutions are provided.
Resumo:
This study investigates how far customization in attendance act as clients faithfulness factor in top style interior design stores in Great Vitoria. After relative economic stability was reached with ¿Plano Real¿, customers could visualize better their money and consequently gave it more value. When clients acquire a product and demand high quality attendance they consider much beyond price. They want something new. Something that surprise. They are not satisfied only with what is best. They want the utmost. Do what is best is no longer a competitive advantage. It is now just a duty. Emphasizes application of custom-made attendance according to client specific needs as a competitive advantage-key to be pursued by companies. Analyses using extensive literature review including the world wide web source, the problem main theoretical fundaments. An intentional sample was used and interviews with closed questions were carried out with 230 clients and 18 store managers, to collect directly involved agents impressions. Conclusions show a mature customer, highly educated with good income and that demand exclusive treatment. In majority the study shows that customized attendance creates client faithfulness to top style interior design stores provided that price and product quality are adequate. Knowledge acquired with this study on attendance customization can give important contributions to top style interior design segment giving stores stimulus in the adoption of this distinctive competence facing growing global competitive market.
Resumo:
The system built to characterize electrodes and, consequently, deposited fine films are constituted by a hollow cathode that works to discharges and low pressures (approximately 10-3 to 5 mbar), a source DC (0 to 1200 V), a cylindrical camera of closed borossilicato for flanges of stainless steel with an association of vacuum bombs mechanical and spread. In the upper flange it is connected the system of hollow cathode, which possesses an entrance of gas and two entrances for its refrigeration, the same is electrically isolated of the rest of the equipment and it is polarized negatively. In front of the system of hollow cathode there is a movable sample in stainless steel with possibility of moving in the horizontal and vertical. In the vertical, the sample can vary its distance between 0 and 70 mm and, in the horizontal, can leave completely from the front of the hollow cathode. The sample and also the cathode hollow are equipped with cromel-alumel termopares with simultaneous reading of the temperatures during the time of treatment. In this work copper electrodes, bronze, titanium, iron, stainless steel, powder of titanium, powder of titanium and silício, glass and ceramic were used. The electrodes were investigated relating their geometry change and behavior of the plasma of the cavity of hollow cathode and channel of the gas. As the cavity of hollow cathode, the analyzed aspects were the diameter and depth. With the channel of the gas, we verified the diameter. In the two situations, we investigated parameters as flow of the gas, pressure, current and applied tension in the electrode, temperature, loss of mass of the electrode with relationship at the time of use. The flow of gas investigated in the electrodes it was fastened in a work strip from 15 to 6 sccm, the constant pressure of work was among 2.7 to 8 x 10-2 mbar. The applied current was among a strip of work from 0,8 to 0,4 A, and their respective tensions were in a strip from 400 to 220 V. Fixing the value of the current, it was possible to lift the curve of the behavior of the tension with the time of use. That curves esteem in that time of use of the electrode to its efficiency is maximum. The temperatures of the electrodes were in the dependence of that curves showing a maximum temperature when the tension was maximum, yet the measured temperatures in the samples showed to be sensitive the variation of the temperature in the electrodes. An accompaniment of the loss of mass of the electrode relating to its time of use showed that the electrodes that appeared the spherical cavities lost more mass in comparison with the electrodes in that didn't appear. That phenomenon is only seen for pressures of 10-2 mbar, in these conditions a plasma column is formed inside of the channel of the gas and in certain points it is concentrated in form of spheres. Those spherical cavities develop inside of the channel of the gas spreading during the whole extension of the channel of the gas. The used electrodes were cut after they could not be more used, however among those electrodes, films that were deposited in alternate times and the electrodes that were used to deposit films in same times, those films were deposited in the glass substrata, alumina, stainless steel 420, stainless steel 316, silício and steel M2. As the eletros used to deposit films in alternate time as the ones that they were used to deposit in same times, the behavior of the thickness of the film obeyed the curve of the tension with relationship the time of use of the electrode, that is, when the tension was maximum, the thickness of the film was also maximum and when the tension was minimum, the thickness was minimum and in the case where the value of the tension was constant, the thickness of the film tends to be constant. The fine films that were produced they had applications with nano stick, bio-compatibility, cellular growth, inhibition of bacterias, cut tool, metallic leagues, brasagem, pineapple fiber and ornamental. In those films it was investigated the thickness, the adherence and the uniformity characterized by sweeping electronic microscopy. Another technique developed to assist the production and characterization of the films produced in that work was the caloteste. It uses a sphere and abrasive to mark the sample with a cap impression, with that cap form it is possible to calculate the thickness of the film. Through the time of life of the cathode, it was possible to evaluate the rate of waste of its material for the different work conditions. Values of waste rate up to 3,2 x 10-6 g/s were verified. For a distance of the substratum of 11 mm, the deposited film was limited to a circular area of 22 mm diameter mm for high pressures and a circular area of 75 mm for pressure strip. The obtained films presented thickness around 2,1 µm, showing that the discharge of arch of hollow cathode in argon obeys a curve characteristic of the tension with the time of life of the eletrodo. The deposition rate obtained in this system it is of approximately 0,18 µm/min
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)