998 resultados para CT-DNA


Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: To be effective and selective, immunotherapy ideally targets specifically tumor cells and spares normal tissues. Identification of tumor specific antigens is a prerequisite to establish an effective immunotherapy. Still very little is known about the expression of tumor-related antigens in pancreatic neoplasms. Cancer Testis antigens (CT) are antigens shared by a variety of malignant tumors, but not by normal tissues with the exception of germ cells in testis. Restricted expression in neoplastic tissues and inherent immunogenic features make CT antigens ideal for use in immunotherapy. We analyzed the expression of a selected panel of nine CT antigens that have been proven to elicit an efficient immunogenic response in other malignancies. In addition we analyzed the expression of HERV-K-MEL, an immunogenic antigen of viral origin. METHODS: Pancreatic adenocarcinoma tumor samples (n=130) were obtained intraoperatively, control tissues (n=23) were collected from cadaveric donor and from patients with chronic pancreatitis. Tumor-associated antigen expression of MAGE-A1, MAGE-A3, MAGE-A4, MAGE-A10, LAGE-1, NY-ESO-1, SCP-1, SSX-2, SSX-4 and HERV-K-MEL was assessed by PCR. Sequencing of PCR products were performed to assess the expression of SSX-4 in neoplastic and normal pancreatic tissues. RESULTS: Three of 10 tested antigens were expressed in over 10% of malignant pancreatic tissue samples. SSX-4 was found positive in 30% of cases, SCP-1 in 19% and HERV-K-MEL in 23% of cases. No expression of CT antigens was found in non-malignant pancreatic tissue with the exception of SSX-4 and and SSX-2. CONCLUSIONS: Fifty two percentage of the analyzed tissues expressed at least one CT antigen. The concomitant expression of SSX-4 in both malignant and non-malignant pancreatic tissue is a new finding which may raise concerns for immunotherapy. However, HERV-K-MEL is expressed with a relatively high prevalence and may be a candidate for specific immunotherapy in a large subgroup of pancreatic cancer patients. This study advocates the analysis of patients with regard to their immunogenic profile before the onset of antigen-specific immunotherapy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The three subtypes of the peroxisome proliferator-activated receptors (PPARalpha, beta/delta, and gamma) form heterodimers with the 9-cis-retinoic acid receptor (RXR) and bind to a common consensus response element, which consists of a direct repeat of two hexanucleotides spaced by one nucleotide (DR1). As a first step toward understanding the molecular mechanisms determining PPAR subtype specificity, we evaluated by electrophoretic mobility shift assays the binding properties of the three PPAR subtypes, in association with either RXRalpha or RXRgamma, on 16 natural PPAR response elements (PPREs). The main results are as follows. (i) PPARgamma in combination with either RXRalpha or RXRgamma binds more strongly than PPARalpha or PPARbeta to all natural PPREs tested. (ii) The binding of PPAR to strong elements is reinforced if the heterodimerization partner is RXRgamma. In contrast, weak elements favor RXRalpha as heterodimerization partner. (iii) The ordering of the 16 natural PPREs from strong to weak elements does not depend on the core DR1 sequence, which has a relatively uniform degree of conservation, but correlates with the number of identities of the 5'-flanking nucleotides with respect to a consensus element. This 5'-flanking sequence is essential for PPARalpha binding and thus contributes to subtype specificity. As a demonstration of this, the PPARgamma-specific element ARE6 PPRE is able to bind PPARalpha only if its 5'-flanking region is exchanged with that of the more promiscuous HMG PPRE.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to evaluate and compare organ doses delivered to patients in wrist and petrous bone examinations using a multislice spiral computed tomography (CT) and a C-arm cone-beam CT equipped with a flat-panel detector (XperCT). For this purpose, doses to the target organ, i.e. wrist or petrous bone, together with those to the most radiosensitive nearby organs, i.e. thyroid and eye lens, were measured and compared. Furthermore, image quality was compared for both imaging systems and different acquisition modes using a Catphan phantom. Results show that both systems guarantee adequate accuracy for diagnostic purposes for wrist and petrous bone examinations. Compared with the CT scanner, the XperCT system slightly reduces the dose to target organs and shortens the overall duration of the wrist examination. In addition, using the XperCT enables a reduction of the dose to the eye lens during head scans (skull base and ear examinations).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Amplified ribosomal DNA restriction analysis (ARDRA) is a simple method based on restriction endonuclease digestion of the amplified bacterial 16S rDNA. In this study we have evaluated the suitability of this method to detect differences in activated sludge bacterial communities fed on domestic or industrial wastewater, and subject to different operational conditions. The ability of ARDRA to detect these differences has been tested in modified Ludzack-Ettinger (MLE) configurations. Samples from three activated sludge wastewater treatment plants (WWTPs) with the MLE configuration were collected for both oxic and anoxic reactors, and ARDRA patterns using double enzyme digestions AluI+MspI were obtained. A matrix of Dice similarity coefficients was calculated and used to compare these restriction patterns. Differences in the community structure due to influent characteristics and temperature could be observed, but not between the oxic and anoxic reactors of each of the three MLE configurations. Other possible applications of ARDRA for detecting and monitoring changes in activated sludge systems are also discussed

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In the past decade, a number of single-molecule methods have been developed with the aim of investigating single protein and nucleic acid interactions. For the first time we use solid-state nanopore sensing to detect a single E. coli RNAP-DNA transcription complex and single E. coli RNAP enzyme. On the basis of their specific conductance translocation signature, we can discriminate and identify between those two types of molecular translocations and translocations of bare DNA. This opens up a new perspectives for investigating transcription processes at the single-molecule level.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Posttransplant lymphoproliferative disease (PTLD) is, aside skin cancer, the most common malignancy occurring after solid organ transplant in adults. Fluorodeoxyglucose (FDG) positron emission tomography (PET) has proved useful in the management of lymphomas. METHODS: We report our experience with the use of FDG-PET inline with computed tomography (CT) scanning in the management of four transplant recipients with histologically confirmed PTLD, including three monomorphic PTLDs and one polymorphic PTLD. RESULTS: FDG-PET/CT scan at diagnosis showed increased FDG uptake in all examined PTLD lesions, and the disease was upstaged on the basis of FDG-PET/CT scan results over conventional CT scanning in one patient. At the end of treatment, PET/CT scans no longer demonstrated FDG uptake in the original PTLD lesions in all patients. Complete remission of disease persisted for at least 1 year after diagnosis in all. CONCLUSIONS: Our results strongly support that FDG-PET scanning is highly specific for diagnosis and follow-up of PTLD. The clinical relevance of including FDG-PET/CT scanning in the management of PTLD should be evaluated in a larger prospective cohort study.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

DNA condensation observed in vitro with the addition of polyvalent counterions is due to intermolecular attractive forces. We introduce a quantitative model of these forces in a Brownian dynamics simulation in addition to a standard mean-field Poisson-Boltzmann repulsion. The comparison of a theoretical value of the effective diameter calculated from the second virial coefficient in cylindrical geometry with some experimental results allows a quantitative evaluation of the one-parameter attractive potential. We show afterward that with a sufficient concentration of divalent salt (typically approximately 20 mM MgCl(2)), supercoiled DNA adopts a collapsed form where opposing segments of interwound regions present zones of lateral contact. However, under the same conditions the same plasmid without torsional stress does not collapse. The condensed molecules present coexisting open and collapsed plectonemic regions. Furthermore, simulations show that circular DNA in 50% methanol solutions with 20 mM MgCl(2) aggregates without the requirement of torsional energy. This confirms known experimental results. Finally, a simulated DNA molecule confined in a box of variable size also presents some local collapsed zones in 20 mM MgCl(2) above a critical concentration of the DNA. Conformational entropy reduction obtained either by supercoiling or by confinement seems thus to play a crucial role in all forms of condensation of DNA.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Combined positron emission tomography and computed tomography (PET/CT) scanners play a major role in medicine for in vivo imaging in an increasing number of diseases in oncology, cardiology, neurology, and psychiatry. With the advent of short-lived radioisotopes other than 18F and newer scanners, there is a need to optimize radioisotope activity and acquisition protocols, as well as to compare scanner performances on an objective basis. The Discovery-LS (D-LS) was among the first clinical PET/CT scanners to be developed and has been extensively characterized with older National Electrical Manufacturer Association (NEMA) NU 2-1994 standards. At the time of publication of the latest version of the standards (NU 2-2001) that have been adapted for whole-body imaging under clinical conditions, more recent models from the same manufacturer, i.e., Discovery-ST (D-ST) and Discovery-STE (D-STE), were commercially available. We report on the full characterization both in the two- and three-dimensional acquisition mode of the D-LS according to latest NEMA NU 2-2001 standards (spatial resolution, sensitivity, count rate performance, accuracy of count losses, and random coincidence correction and image quality), as well as a detailed comparison with the newer D-ST widely used and whose characteristics are already published.