996 resultados para CT value


Relevância:

20.00% 20.00%

Publicador:

Resumo:

En aquest treball presentem dues caracteritzacions de dos valors diferents en el marc dels jocs coalicionals amb cooperació restringida. Les restriccions són introduïdes com una seqüència finita de particions del conjunt del jugadors, de manera que cada una d'elles eés més grollera que l'anterior, formant així una estructura amb diferents nivells d'unions a priori.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: Our objective is to describe pouchography, CT, and MRI features of the J-shaped pouch, both normal and with pouch-related complications. CONCLUSION: Pouchography is performed before closure of the loop ileostomy to assess the integrity of the ileal pouch and anastomosis. CT and MRI can be performed when postoperative complications, such as small-bowel obstruction, pouchitis, leakage, abscess, intramural hematoma, desmoid tumor, or recurrent Crohn's disease, are suspected.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Screening of elevated blood pressure (BP) in children has been advocated to early identify hypertension. However, identification of children with sustained elevated BP is challenging due to the high BP variability. The value of an elevated BP measure during childhood and adolescence for the prediction of future elevated BP is not well described. Objectives: We assessed the positive (PPV) and negative (NPV) predictive value of high BP for sustained elevated BP in cohorts of children of the Seychelles, a rapidly developing island state in the African region. Methods: Serial school-based surveys of weight, height, and BP were conducted yearly between 1998-2006 among all students of the country in four school grades (kindergarten [G0, mean age (SD): 5.5 (0.4) yr], G4 [9.2 (0.4) yr], G7 [12.5 (0.4) yr] and G10 (15.6 (0.5) yr]. We constituted three cohorts of children examined twice at 3-4 years interval: 4,557 children examined at G0 and G4, 6,198 at G4 and G7, and 6,094 at G7 and G10. The same automated BP measurement devices were used throughout the study. BP was measured twice at each exam and averaged. Obesity and elevated BP were defined using the CDC (BMI_95th sex-, and age-specific percentile) and the NHBPEP criteria (BP_95th sex-, age-, and height specific percentile), respectively. Results: Prevalence of obesity was 6.1% at G0, 7.1% at G4, 7.5% at G7, and 6.5% at G10. Prevalence of elevated BP was 10.2% at G0, 9.9% at G4, 7.1% at G7, and 8.7% at G10. Among children with elevated BP at initial exam, the PPV of keeping elevated BP was low but increased with age: 13% between G0 and G4, 19% between G4 and G7, and 27% between G7 and G10. Among obese children with elevated BP, the PPV was higher: 33%, 35% and 39% respectively. Overall, the probability for children with normal BP to remain in that category 3-4 years later (NPV) was 92%, 95%, and 93%, respectively. By comparison, the PPV for children initially obese to remain obese was much higher at 71%, 71%, and 62% (G7-G10), respectively. The NPV (i.e. the probability of remaining at normal weight) was 94%, 96%, and 98%, respectively. Conclusion: During childhood and adolescence, having an elevated BP at one occasion is a weak predictor of sustained elevated BP 3-4 years later. In obese children, it is a better predictor.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The Simpson-Golabi-Behmel syndrome type 1 (SGBS1, OMIM #312870) is an X-linked overgrowth condition comprising abnormal facial appearance, supernumerary nipples, congenital heart defects, polydactyly, fingernail hypoplasia, increased risk of neonatal death and of neoplasia. It is caused by mutation/deletion of the GPC3 gene. We describe a macrosomic 27-week preterm newborn with SGBS1 who presents a novel GPC3 mutation and emphasize the phenotypic aspects which allow a correct diagnosis neonatally in particular the rib malformations, hypoplasia of index finger and of the same fingernail, and 2nd-3rd finger syndactyly.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this article was to review the strategies to control patient dose in adult and pediatric computed tomography (CT), taking into account the change of technology from single-detector row CT to multi-detector row CT. First the relationships between computed tomography dose index, dose length product, and effective dose in adult and pediatric CT are revised, along with the diagnostic reference level concept. Then the effect of image noise as a function of volume computed tomography dose index, reconstructed slice thickness, and the size of the patient are described. Finally, the potential of tube current modulation CT is discussed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Metabolic syndrome represents a grouping of risk factors closely linked to cardiovascular diseases and diabetes. At first, nuclear medicine has no direct application in cardiology at the level of primary prevention, but positron emission tomography is a non invasive imaging technique that can assess myocardial perfusion as well as the endothelium-dependent coronary vasomotion--a surrogate marker of cardiovascular event rate--thus finding an application in studying coronary physiopathology. As the prevalence of the metabolic syndrome is still unknown in Switzerland, we will estimate it from data available in the frame of a health promotion program. Based on the deleterious effect on the endothelium already observed with two components, we will estimate the number of persons at risk in Switzerland.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: A misleading blood tacrolimus concentration (BTC) value caused by the contamination of a central venous catheter previously used for tacrolimus administration is described. SUMMARY: A 59-year-old woman with severe chronic obstructive pulmonary disease successfully underwent double lung transplantation. In the intensive care unit, she received a continuous i.v. infusion of tacrolimus from days 1 to 5 after transplantation through the distal lumen of a polyurethane triple-lumen central venous catheter. The catheter lumen was flushed twice a day with 0.9% sodium chloride injection. The proximal lumen was used for blood sampling after being flushed; the first 10 mL of blood was discarded. BTCs determined in whole blood one, four, and five days after transplantation were within the therapeutic range of 5-15 ng/mL. On day five the patient was transferred to the thoracic surgery ward and was switched to oral tacrolimus 1.5 mg twice daily. The BTC on day 6 was unexpectedly high at 134.5 ng/mL. The patient's clinical status was normal, and no signs of tacrolimus toxicity were observed. On day 7, blood samples were drawn from a peripheral vein and simultaneously through the central venous catheter. Although the central venous catheter had not been exposed to tacrolimus during the preceding two days, it yielded blood with a BTC eight times higher than the BTC in blood from the peripheral vein (41.4 ng/mL versus 5.1 ng/mL). CONCLUSION: The collection of blood from a central venous catheter lumen that had been used for tacrolimus administration resulted in a BTC about eight times higher than what was measured in peripheral blood.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Selostus: Natrium- ja kaliumlannoituksen vaikutus timotein ravintoarvoon

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In the 1920s, Ronald Fisher developed the theory behind the p value and Jerzy Neyman and Egon Pearson developed the theory of hypothesis testing. These distinct theories have provided researchers important quantitative tools to confirm or refute their hypotheses. The p value is the probability to obtain an effect equal to or more extreme than the one observed presuming the null hypothesis of no effect is true; it gives researchers a measure of the strength of evidence against the null hypothesis. As commonly used, investigators will select a threshold p value below which they will reject the null hypothesis. The theory of hypothesis testing allows researchers to reject a null hypothesis in favor of an alternative hypothesis of some effect. As commonly used, investigators choose Type I error (rejecting the null hypothesis when it is true) and Type II error (accepting the null hypothesis when it is false) levels and determine some critical region. If the test statistic falls into that critical region, the null hypothesis is rejected in favor of the alternative hypothesis. Despite similarities between the two, the p value and the theory of hypothesis testing are different theories that often are misunderstood and confused, leading researchers to improper conclusions. Perhaps the most common misconception is to consider the p value as the probability that the null hypothesis is true rather than the probability of obtaining the difference observed, or one that is more extreme, considering the null is true. Another concern is the risk that an important proportion of statistically significant results are falsely significant. Researchers should have a minimum understanding of these two theories so that they are better able to plan, conduct, interpret, and report scientific experiments.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To evaluate if heroin and cocaine can be distinguished using dual-energy CT. MATERIALS AND METHODS: Twenty samples of heroin and cocaine at different concentrations and standardized compression (SC) were scanned in dual-energy mode on a newest generation Dual Energy 64-row MDCT scanner. CT number, spectral graphs, and dual-energy index (DEI) were evaluated. Results were prospectively tested on six original samples from a body packer. Wilcoxon's test was used for statistical evaluation. RESULTS: Values are given as median and range. Under SC, the CT number of cocaine samples (-29.87 Hounsfield unit (HU) [-125.85; 16.16 HU]) was higher than the CT number of heroin samples (-184.37 HU [-199.81; -159.25 HU]; p < 0.01). Slope of spectral curves for cocaine was -2.36 HU/keV [-7.15; -0.67 HU/keV], and for heroin, 1.75 HU/keV [1.28; 2.5 HU/keV] (p < 0.01). DEI was 0.0352 [0.0081; 0.0528] for cocaine and significantly higher than for heroin samples (-0.0127 [-0.0097; -0.0159]; p < 0.001). While CT number was inconclusive, all six original packs were correctly classified after evaluation of the spectral curve and DEI. In contrast to the CT number, slope of the spectral curve and DEI were independent of concentration and compression. CONCLUSION: The slope of the spectral curve and the DEI from dual-energy CT data can be used to distinguish heroin and cocaine in vitro; these results are independent of compression and concentration in the measured range.