962 resultados para C-flow


Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: Individual adaptation of processed patient's blood volume (PBV) should reduce number and/or duration of autologous peripheral blood progenitor cell (PBPC) collections. STUDY DESIGN AND METHODS: The durations of leukapheresis procedures were adapted by means of an interim analysis of harvested CD34+ cells to obtain the intended yield of CD34+ within as few and/or short as possible leukapheresis procedures. Absolute efficiency (AE; CD34+/kg body weight) and relative efficiency (RE; total CD34+ yield of single apheresis/total number of preapheresis CD34+) were calculated, assuming an intraapheresis recruitment if RE was greater than 1, and a yield prediction models for adults was generated. RESULTS: A total of 196 adults required a total of 266 PBPC collections. The median AE was 7.99 x 10(6), and the median RE was 1.76. The prediction model for AE showed a satisfactory predictive value for preapheresis CD34+ only. The prediction model for RE also showed a low predictive value (R2 = 0.36). Twenty-eight children underwent 44 PBPC collections. The median AE was 12.13 x 10(6), and the median RE was 1.62. Major complications comprised bleeding episodes related to central venous catheters (n = 4) and severe thrombocytopenia of less than 10 x 10(9) per L (n = 16). CONCLUSION: A CD34+ interim analysis is a suitable tool for individual adaptation of the duration of leukapheresis. During leukapheresis, a substantial recruitment of CD34+ was observed, resulting in a RE of greater than 1 in more than 75 percent of patients. The upper limit of processed PBV showing an intraapheresis CD34+ recruitment is higher than in a standard large-volume leukapheresis. Therefore, a reduction of individually needed PBPC collections by means of a further escalation of the processed PBV seems possible.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE: We estimated the diagnostic accuracy of ultrasound detrusor thickness measurement for BOO and investigated whether this method can replace PFS for the diagnosis of BOO in some patients with lower urinary tract symptoms. MATERIALS AND METHODS: Detrusor thickness was measured by linear ultrasound (7.5 MHz) at a filling volume of greater than 50% of cystometric capacity in 102 men undergoing PFS for LUTS. All patients with prior treatment for bladder outlet obstruction and those with underlying neurological disorders were excluded from analysis. Detrusor thickness was correlated with PFS data. Obstruction was defined according to the Abrams-Griffiths nomogram. RESULTS: Detrusor thickness was significantly higher (p <0.0001) in obstructed (61 cases, median detrusor thickness 2.7 mm, IQR 2.4 to 3.3) compared to unobstructed (18 cases, median detrusor thickness 1.7 mm, IQR 1.5 to 2) as well as equivocal (23 cases, median detrusor thickness 1.8 mm, IQR 1.5 to 2.2) cases. A weak to medium Spearman correlation was found between detrusor thickness and PFS parameters. For a diagnosis of BOO, detrusor thickness of 2.9 mm or greater had a positive predictive value of 100%, a negative predictive value of 54%, specificity of 100% and sensitivity of 43%. ROC analysis revealed that detrusor thickness had a high predictive value for BOO with an AUC of 0.88 (95% CI 0.81-0.94). CONCLUSIONS: In men with LUTS without prior treatment and/or neurological disorders, ultrasonographically assessed detrusor thickness 2.9 mm or greater has a high predictive value for BOO and can replace PFS for the diagnosis of BOO. However, this cutoff value needs to be validated in a larger study population.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Dyskeratosis congenita (DC) is an inherited bone marrow failure syndrome in which the known susceptibility genes (DKC1, TERC, and TERT) belong to the telomere maintenance pathway; patients with DC have very short telomeres. We used multicolor flow fluorescence in situ hybridization analysis of median telomere length in total blood leukocytes, granulocytes, lymphocytes, and several lymphocyte subsets to confirm the diagnosis of DC, distinguish patients with DC from unaffected family members, identify clinically silent DC carriers, and discriminate between patients with DC and those with other bone marrow failure disorders. We defined "very short" telomeres as below the first percentile measured among 400 healthy control subjects over the entire age range. Diagnostic sensitivity and specificity of very short telomeres for DC were more than 90% for total lymphocytes, CD45RA+/CD20- naive T cells, and CD20+ B cells. Granulocyte and total leukocyte assays were not specific; CD45RA- memory T cells and CD57+ NK/NKT were not sensitive. We observed very short telomeres in a clinically normal family member who subsequently developed DC. We propose adding leukocyte subset flow fluorescence in situ hybridization telomere length measurement to the evaluation of patients and families suspected to have DC, because the correct diagnosis will substantially affect patient management.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

INTRODUCTION: Vasopressin has been shown to increase blood pressure in catecholamine-resistant septic shock. The aim of this study was to measure the effects of low-dose vasopressin on regional (hepato-splanchnic and renal) and microcirculatory (liver, pancreas, and kidney) blood flow in septic shock. METHODS: Thirty-two pigs were anesthetized, mechanically ventilated, and randomly assigned to one of four groups (n = 8 in each). Group S (sepsis) and group SV (sepsis/vasopressin) were exposed to fecal peritonitis. Group C and group V were non-septic controls. After 240 minutes, both septic groups were resuscitated with intravenous fluids. After 300 minutes, groups V and SV received intravenous vasopressin 0.06 IU/kg per hour. Regional blood flow was measured in the hepatic and renal arteries, the portal vein, and the celiac trunk by means of ultrasonic transit time flowmetry. Microcirculatory blood flow was measured in the liver, kidney, and pancreas by means of laser Doppler flowmetry. RESULTS: In septic shock, vasopressin markedly decreased blood flow in the portal vein, by 58% after 1 hour and by 45% after 3 hours (p < 0.01), whereas flow remained virtually unchanged in the hepatic artery and increased in the celiac trunk. Microcirculatory blood flow decreased in the pancreas by 45% (p < 0.01) and in the kidney by 16% (p < 0.01) but remained unchanged in the liver. CONCLUSION: Vasopressin caused marked redistribution of splanchnic regional and microcirculatory blood flow, including a significant decrease in portal, pancreatic, and renal blood flows, whereas hepatic artery flow remained virtually unchanged. This study also showed that increased urine output does not necessarily reflect increased renal blood flow.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: Vasopressin increases arterial pressure in septic shock even when alpha-adrenergic agonists fail. The authors studied the effects of vasopressin on microcirculatory blood flow in the entire gastrointestinal tract in anesthetized pigs during early septic shock. METHODS: Thirty-two pigs were intravenously anesthetized, mechanically ventilated, and randomly assigned to one of four groups (n=8 in each; full factorial design). Group S (sepsis) and group SV (sepsis-vasopressin) were made septic by fecal peritonitis. Group C and group V were nonseptic control groups. After 300 min, group V and group SV received intravenous infusion of 0.06 U.kg.h vasopressin. In all groups, cardiac index and superior mesenteric artery flow were measured. Microcirculatory blood flow was recorded with laser Doppler flowmetry in both mucosa and muscularis of the stomach, jejunum, and colon. RESULTS: While vasopressin significantly increased arterial pressure in group SV (P<0.05), superior mesenteric artery flow decreased by 51+/-16% (P<0.05). Systemic and mesenteric oxygen delivery and consumption decreased and oxygen extraction increased in the SV group. Effects on the microcirculation were very heterogeneous; flow decreased in the stomach mucosa (by 23+/-10%; P<0.05), in the stomach muscularis (by 48+/-16%; P<0.05), and in the jejunal mucosa (by 27+/-9%; P<0.05), whereas no significant changes were seen in the colon. CONCLUSION: Vasopressin decreased regional flow in the superior mesenteric artery and microcirculatory blood flow in the upper gastrointestinal tract. This reduction in flow and a concomitant increase in the jejunal mucosa-to-arterial carbon dioxide gap suggest compromised mucosal blood flow in the upper gastrointestinal tract in septic pigs receiving low-dose vasopressin.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

INTRODUCTION: Peripheral arterial disease (PAD) is associated with systemic impaired flow-mediated dilation (FMD) and increased risk for cardiovascular events. Decreased FMD may be caused by a decrease in arterial shear stress due to claudication and inflammation due to muscle ischemia and reperfusion. We assumed that endovascular revascularization of lower limb arterial obstructions ameliorates FMD and lowers inflammation through improvement of peripheral perfusion. METHODS: The study was a prospective, open, randomized, controlled, single-center follow-up evaluation assessing the effect of endovascular revascularization on brachial artery reactivity (FMD) measured by ultrasound, white blood cell (WBC) count, high-sensitive C-reactive protein (hs-CRP), and fibrinogen. We investigated 33 patients (23 men) with chronic and stable PAD (Rutherford 2 to 3) due to femoropopliteal obstruction. Variables were assessed at baseline and after 4 weeks in 17 patients (group A) who underwent endovascular revascularization and best medical treatment, and in 16 patients (group B) who received best medical treatment only. RESULTS: FMD did not differ between group A and B (4.96% +/- 1.86% vs 4.60% +/- 2.95%; P = .87) at baseline. It significantly improved after revascularization in group A (6.44% +/- 2.88%; P = .02) compared with group B at 4 weeks of follow-up (4.53% +/- 3.17%; P = .92), where it remained unchanged. The baseline ankle-brachial index (ABI) was similar for group A and B (0.63 +/- 0.15 vs 0.66 +/- 0.10; P = .36). At 4 weeks of follow-up, ABI was significantly increased in group A (1.05 +/- 0.15; P = .0004) but remained unchanged in group B (0.62 +/- 0.1). WBC counts of the two groups were comparable at baseline (group A: 7.6 +/- 2.26 x 10(6)/mL and group B: 7.8 +/- 2.02 x 10(6)/mL, P = .81). In group A, the leukocyte count significantly decreased after angioplasty from 7.6 +/- 2.26 to 6.89 +/- 1.35 x 10(6)/mL (P = .03). For group B, WBC count did not differ significantly compared with baseline (7.76 +/- 2.64 x 10(6)/mL; P = .94). No effects were observed on hs-CRP or fibrinogen from endovascular therapy. CONCLUSION: Endovascular revascularization with reestablishment of peripheral arterial perfusion improves FMD and reduces WBC count in patients with claudication. Revascularization may therefore have clinical implications beyond relief of symptoms, for example, reducing oxidative stress caused by repeated muscle ischemia or increased shear stress due to improved ambulatory activity.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The authors describe the use of the Cardica C-Port xA Distal Anastomosis System to perform an automated, high-flow extracranial-intracranial bypass. The C-Port system has been developed and tested in coronary artery bypass surgery for rapid distal coronary artery anastomoses. Air-powered, it performs an automated end-to-side anastomosis within seconds by nearly simultaneously making an arteriotomy and inserting 13 microclips into the graft and recipient vessel. Intracranial use of the device was first simulated in a cadaver prepared for microsurgical anatomical dissection. The authors used this system in a 43-year-old man who sustained a subarachnoid hemorrhage after being assaulted and was found to have a traumatic pseudoaneurysm of the proximal intracranial internal carotid artery. The aneurysm appeared to be enlarging on serial imaging studies and it was anticipated that a bypass would probably be needed to treat the lesion. An end-to-side bypass was performed with the C-Port system using a saphenous vein conduit extending from the common carotid artery to the middle cerebral artery. The bypass was demonstrated to be patent on intraoperative and postoperative arteriography. The patient had a temporary hyperperfusion syndrome and subsequently made a good neurological recovery. The C-Port system facilitates the performance of a high-flow extracranial-intracranial bypass with short periods of temporary arterial occlusion. Because of the size and configuration of the device, its use is not feasible in all anatomical situations that require a high-flow bypass; however it is a useful addition to the armamentarium of the neurovascular surgeon.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: Acne inversa (hidradenitis suppurativa) is a chronic inflammatory and cicatricial disorder that affects skin areas rich in apocrine glands and terminal hairs, such as perineum and axillae. The exact pathogenesis of the disease is not well understood and the mechanisms by which bacterial superinfection contributes to the disease progression are not clear. Toll-like receptors (TLRs) expressed by inflammatory cells play a crucial role in the innate immune response to bacteria. OBJECTIVES: We sought to investigate the role of TLR2 in the pathogenesis of acne inversa. METHODS: We investigated the expression of TLR2 using real-time polymerase chain reaction analysis and immunohistochemical stainings of tissue samples from patients with acne inversa. Furthermore, we phenotypically characterized the infiltrating cells and their expression of TLR2. RESULTS: Compared with normal skin, a highly increased in situ expression of TLR2 in acne inversa skin lesions was found at both the mRNA and the protein level. The most abundant cells in the dermal infiltrate of acne inversa were CD68+ macrophages, CD209+ dendritic cells (DCs) and CD3+ T cells. CD19+ B cells and CD56+ natural killer cells were found only in small numbers. Double staining with fluorescence-labelled antibodies showed that TLR2 was expressed by infiltrating macrophages (CD68+) and DCs (CD209+). Flow cytometric analysis of isolated infiltrating cells further confirmed surface expression of TLR2 by macrophages and DCs. CONCLUSIONS: These data indicate that the enhanced expression of TLR2 by infiltrating macrophages and DCs may contribute to the pathogenesis of inflammatory lesions of acne inversa.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Assessment of regional blood flow changes is difficult in the clinical setting. We tested whether conventional pulmonary artery catheters (PACs) can be used to measure regional venous blood flows by inverse thermodilution (ITD). Inverse thermodilution was tested in vitro and in vivo using perivascular ultrasound Doppler (USD) flow probes as a reference. In anesthetized pigs, PACs were inserted in jugular, hepatic, renal, and femoral veins, and their measurements were compared with simultaneous USD flow measurements from carotid, hepatic, renal, and femoral arteries and from portal vein. Fluid boluses were injected through the PAC's distal port, and temperature changes were recorded from the proximally located thermistor. Injectates of 2 and 5 mL at 22 degrees C and 4 degrees C were used. Flows were altered by using a roller pump (in vitro), and infusion of dobutamine and induction of cardiac tamponade, respectively. In vitro: At blood flows between 400 mL . min-1 and 700 mL . min-1 (n = 50), ITD and USD correlated well (r = 0.86, P < 0.0001), with bias and limits of agreement of 3 +/- 101 mL . min-1. In vivo: 514 pairs of measurements had to be excluded from analysis for technical reasons, and 976 were analyzed. Best correlations were r = 0.87 (P < 0.0001) for renal flow and r = 0.46 (P < 0.0001) for hepatic flow. No significant correlation was found for cerebral and femoral flows. Inverse thermodilution using conventional PAC compared moderately well with USD for renal but not for other flows despite good in vitro correlation in various conditions. In addition, this method has significant technical limitations.