963 resultados para B. Composite
Resumo:
BACKGROUND: Use of polyclonal anti-hepatitis B surface antigen immunoglobulin (HBIg) has been shown to reduce hepatitis B virus (HBV) recurrence after liver transplantation (LT) and to decrease the frequency of acute cellular rejection (ACR). However, the protective role of HBIg against ACR remains controversial, since HBV infection has been also associated with a lower incidence of ACR. AIM: To assess the relationship between HBIg immunoprophylaxis and the incidence of rejection after LT. METHODS: 260 patients (158 males, 43 ± 14 years old) submitted to LT were retrospectively evaluated and divided into three groups, according to the presence of HBsAg and the use of HBIg. Group I was comprised of HBsAg-positive patients (n = 12) that received HBIg for more than 6 months. Group II was comprised of HBsAg-positive patients that historically have not received HBIg or have been treated irregularly for less than 3 months (n = 10). Group III was composed of 238 HBsAg-negative subjects that have not received HBIg. RESULTS: HBIg-treated patients (group I) had significantly less ACR episodes, when compared to group II and III. No differences between groups II and III were observed. CONCLUSIONS: Long-term HBIg administration contributes independently to reduce the number of ACR episodes after LT.
Resumo:
A thirty three year-old, male patient was admitted at the Hospital of the São Paulo University School of Medicine, at the city of São Paulo, Brazil, with complaint of pains, tingling and decreased sensibility in the right hand for the last four months. This had progressed to the left hand, left foot and right foot, in addition to a difficulty of flexing and stretching in the left foot. Tests were positive for HBeAg, IgM anti-HBc and HBsAg, thus characterizing the condition of acute hepatitis B. The ALT serum level was 15 times above the upper normal limit. Blood glucose, cerebral spinal fluid, antinuclear antibodies (ANA) and anti-HIV and anti-HCV serum tests were either normal or negative. Electroneuromyography disclosed severe peripheral neuropathy with an axon prevalence and signs of denervation; nerve biopsy disclosed intense vasculitis. The diagnosis of multiple confluent mononeuropathy associated to acute hepatitis B was done. This association is not often reported in international literature and its probable cause is the direct action of the hepatitis B virus on the nerves or a vasculitis of the vasa nervorum brought about by deposits of immune complexes.
Resumo:
A animação de superfícies deformáveis, nomeadamente a modelação de tecidos, atravessa hoje uma época de grande relevância na indústria do cinema e no mundo dos jogos. A grande dedicação a este tema, em termos de investigação e a evolução das capacidades das arquitecturas de computadores no que toca a poder de processamento, tornou hoje possível efectuar este tipo de simulações usando um vasto leque de técnicas com diferentes objectivos. Entre estas técnicas encontra-se a simulação através de modelos discretos. Geralmente, neste tipo de modelação, as características do tecido são discretizadas num sistema de partículas organizadas entre si segundo um esquema de forças ou energias internas. Assim, a simulação pode ser efectuada integrando o sistema de forma a calcular as novas posições das partículas ao longo do tempo. Este tipo de computação é normalmente caracterizado como sendo bastante intensivo. A aceleração da animação de superfícies deformáveis recorrendo ao poder de processamento para além do CPU convencional foi realizada em vários trabalhos. No entanto, apenas uma pequena parte desses artigos está relacionada com a arquitectura Cell/B.E. O Cell/B.E. foi desenvolvido por uma equipa de investigadores vindos da Toshiba, Sony e IBM. Esta equipa tinha como objectivo a criação de uma arquitectura que suportasse um elevado leque de aplicações, incluindo o suporte de uma consola de jogos, de forma eficaz e com baixo consumo de energia. Assim, o processador Cell/B.E. convencional pode ser descrito por um chip multicore heterogéneo composto por um processador PowerPC e oito processadores vectoriais (SIMD) de 128 bits, permitindo assim ao programador uma maior flexibilidade na forma de paralelização de um determinado processamento. O principal objectivo deste trabalho passou pelo estudo desta arquitectura e da forma de a explorar e avaliar as suas capacidades, aplicando-as na aceleração de um simulador de superfícies deformáveis com
Resumo:
Ammonia is an important gas in many power plants and industrial processes so its detection is of extreme importance in environmental monitoring and process control due to its high toxicity. Ammonia’s threshold limit is 25 ppm and the exposure time limit is 8 h, however exposure to 35 ppm is only secure for 10 min. In this work a brief introduction to ammonia aspects are presented, like its physical and chemical properties, the dangers in its manipulation, its ways of production and its sources. The application areas in which ammonia gas detection is important and needed are also referred: environmental gas analysis (e.g. intense farming), automotive-, chemical- and medical industries. In order to monitor ammonia gas in these different areas there are some requirements that must be attended. These requirements determine the choice of sensor and, therefore, several types of sensors with different characteristics were developed, like metal oxides, surface acoustic wave-, catalytic-, and optical sensors, indirect gas analyzers, and conducting polymers. All the sensors types are described, but more attention will be given to polyaniline (PANI), particularly to its characteristics, syntheses, chemical doping processes, deposition methods, transduction modes, and its adhesion to inorganic materials. Besides this, short descriptions of PANI nanostructures, the use of electrospinning in the formation of nanofibers/microfibers, and graphene and its characteristics are included. The created sensor is an instrument that tries to achieve a goal of the medical community in the control of the breath’s ammonia levels being an easy and non-invasive method for diagnostic of kidney malfunction and/or gastric ulcers. For that the device should be capable to detect different levels of ammonia gas concentrations. So, in the present work an ammonia gas sensor was developed using a conductive polymer composite which was immobilized on a carbon transducer surface. The experiments were targeted to ammonia measurements at ppb level. Ammonia gas measurements were carried out in the concentration range from 1 ppb to 500 ppb. A commercial substrate was used; screen-printed carbon electrodes. After adequate surface pre-treatment of the substrate, its electrodes were covered by a nanofibrous polymeric composite. The conducting polyaniline doped with sulfuric acid (H2SO4) was blended with reduced graphene oxide (RGO) obtained by wet chemical synthesis. This composite formed the basis for the formation of nanofibers by electrospinning. Nanofibers will increase the sensitivity of the sensing material. The electrospun PANI-RGO fibers were placed on the substrate and then dried at ambient temperature. Amperometric measurements were performed at different ammonia gas concentrations (1 to 500 ppb). The I-V characteristics were registered and some interfering gases were studied (NO2, ethanol, and acetone). The gas samples were prepared in a custom setup and were diluted with dry nitrogen gas. Electrospun nanofibers of PANI-RGO composite demonstrated an enhancement in NH3 gas detection when comparing with only electrospun PANI nanofibers. Was visible higher range of resistance at concentrations from 1 to 500 ppb. It was also observed that the sensor had stable, reproducible and recoverable properties. Moreover, it had better response and recovery times. The new sensing material of the developed sensor demonstrated to be a good candidate for ammonia gas determination.
Resumo:
The authors report a male patient, a seller with no detected immunosuppression, with an extensive ulcerated skin lesion localized on the left forearm, caused by Cryptococcus neoformans var. gattii serotype B. Oral treatment with fluconazole was successful. A review of the literature showed the rarity of this localization in HIV-negative patients. In contrast, skin lesions frequently occurs in HIV-positive patients, with Cryptococcus neoformans var. neoformans serotype A predominating as the etiological agent. In this paper, the pathogenicity of C. neoformans to skin lesions in patients immunocompromised or not, is discussed, showing the efficacy of fluconazole for the treatment of these processes.
Resumo:
The presence of serological markers for hepatitis B virus (HBsAg, anti-HBc IgM and Anti-HBc total) was investigated in the serum of 1,396 individuals who had clinical suspect of hepatitis. It was observed that 50.7% of the individuals were positive and, from the total of the studied individuals, 14.5% were positive for HBsAg. From these, 8.5% were also positive for anti-HBc IgM. The analysis in relation to gender showed a higher seroprevalence index among male individuals (p < 0.0001). It was observed the occurrence of subtypes adw2 (62.7%), ayw3 (23.5%), ayw2 (9.8%) and adw4 (3.9%). The viral DNA was detected in 61 (33.9%) HBsAg positive samples and in one sample positive only for anti-HBc total. These results indicate an important incidence of the HBV infection in this population, and reinforce previous studies regarding this virus in the central west region of Brazil.
Resumo:
Through the influenza virus surveillance from January to October 2002, influenza B/Hong Kong-like strains circulating in the Southeast and Centre East regions of Brazil have been demonstrated. This strain is a variant from B/Victoria/02/88 whose since 1991 and until recently have been isolated relatively infrequently and have been limited to South-Eastern Asia. A total of 510 respiratory secretions were collected from patients 0 to 60 years of age, with acute respiratory illness, living in the Southeast and Centre East regions of Brazil, of which 86 (17.13%) were positive for influenza virus. Among them 12 (13.95%) were characterized as B/Hong Kong/330/2001; 3 (3.49%) as B/Hong Kong/1351/2002 a variant from B/Hong Kong/330/2001; 1 (1.16%) as B/Sichuan/379/99; 1 (1.16%) as B/Shizuoka/5/2001, until now. The percentages of cases notified during the surveillance period were 34.88%, 15.12%, 15.12%, 4.65%, 15.12%, 13.95%, in the age groups of 0-4, 5-10, 11-15, 16-20, 21-30, 31-50, respectively. The highest proportion of isolates was observed among children younger than 4 years but serious morbidity and mortality has not been observed among people older than 65 years, although B influenza virus component for vaccination campaign 2002 was B/Sichuan/379/99 strain. This was probably due to the elderly protection acquired against B/Victoria/02/88. In addition, in influenza A/Panama/2007/99-like (H3N2) strains 22 (25.58%) were also detected, but influenza A(H1N1) has not been detected yet.
Resumo:
As the prostate cancer (PCa) progresses, sarcosine levels increase both in tumor cells and urine samples, suggesting that this metabolite measurements can help in the creation of non-invasive diagnostic methods for this disease. In this work, a biosensor device was developed for the quantification of sarcosine via electrochemical detection of H2O2 (at 0.6 V) generated from the catalyzed oxidation of sarcosine. The detection was carried out after the modification of carbon screen printed electrodes (SPEs) by immobilization of sarcosine oxidase (SOX) on the electrode surface. The strategies used herein included the activation of the carbon films by an electrochemical step and the formation of an NHS/EDAC layer to bond the enzyme to the electrode, the use of metallic or semiconductor nanoparticles layer previously or during the enzyme immobilization. In order to improve the sensor stability and selectivity a polymeric layer with extra enzyme content was further added. The proposed methodology for the detection of sarcosine allowed obtaining a limit of detection (LOD) of 16 nM, using a linear concentration range between 10 and 100 nM. The biosensor was successfully applied to the analysis of sarcosine in urine samples.
Resumo:
XIX Meeting of the Portuguese Electrochemical Society - XVI Iberic Meeting of Electrochemistry
Resumo:
We evaluated the immunogenicity of three recombinant hepatitis B vaccines, one Brazilian (Butang, Instituto Butantan) and two Korean vaccines (Euvax-B, LG Chemical Ltd. and Hepavax-Gene, Greencross Vaccine Corp.), administered intramuscularly to students aged 17 to 19 years in three 10-µg doses (corresponding to half the amount of antigen routinely used for adult vaccination) at intervals of one month between the first and second dose, and of four months between the second and third dose. A total of 316 students non-reactive for any serological marker of hepatitis B virus infection were vaccinated: 77 (24.4%) with the Butang vaccine, 71 (22.5%) with Euvax-B, 85 (26.9%) with Hepavax-Gene and, for comparison, 83 (26.2%) with Engerix-B (GlaxoSmithKline), whose efficacy in young adults at the dose used here has been confirmed in previous studies. Similar seroconversion rates (anti-HBs > 10 mIU/mL about one month after application of the third dose) were obtained for the Butang, Euvax-B, Hepavax-Gene and Engerix-B vaccines (96.2%, 98.6%, 96.5% and 97.6%, respectively). The frequency of good responders (anti-HBs > 100 mIU/mL) was also similar among students receiving the four vaccines (85.8%, 91.6%, 89.4% and 89.2%, respectively). The geometric mean titers (GMT) of anti-HBs about one month after the third dose obtained with these vaccines were 727.78 ± 6.46 mIU/mL, 2009.09 ± 7.16 mIU/mL, 1729.82 ± 8.85 mIU/mL and 2070.14 ± 11.69 mIU/mL, respectively. The GMT of anti-HBs induced by the Euvax-B and Engerix-B vaccines were higher than those obtained with the Butang vaccine (p < 0.05); this difference was not significant when comparing the other vaccines two-by-two. No spontaneous adverse effects attributable to the application of any dose of the four vaccines were reported.
Resumo:
Primary cutaneous follicle center lymphoma (PCFCL) is characterized by a proliferation of follicle center cells in the skin. A definitive diagnosis is frequently delayed because of difficulties in interpretation of the histopathologic findings. It has an excellent prognosis with a 5-year survival over 95% and its risk of transformation has not been established. We describe a case report of man with a gastric diffuse large B-cell lymphoma (DLBCL) referred to our clinic because of nodules in the back that had gradually developed over a period of 10 years. A biopsy performed 3 years before was interpreted as reactive follicular hyperplasia. A new skin biopsy revealed a diffuse large B-cell lymphoma and immunoglobulin heavy chain gene rearrangements from the initial skin biopsy (PCBCL) and the DLBCL gastric biopsy were studied by polymerase chain reaction and an identical clonal rearrangement was detected which was highly suggestive of a transformation lymphoma.
Resumo:
Comparative morphometric and morphological studies of eggs under scanning electron microscope (SEM) were undertaken in the three strains of two karyotypic forms of Anopheles aconitus, i.e., Form B (Chiang Mai and Phet Buri strains) and Form C (Chiang Mai and Mae Hong Son strains). Morphometric examination revealed the intraspecific variation with respect to the float width [36.77 ± 2.30 µm (Form C: Chiang Mai strain) = 38.49 ± 2.78 µm (Form B: Chiang Mai strain) = 39.06 ± 2.37 µm (Form B: Phet Buri strain) > 32.40 ± 3.52 µm (Form C: Mae Hong Son strain)] and number of posterior tubercles on deck [2.40 ± 0.52 (Form B: Phet Buri strain) = 2.70 ± 0.82 (Form B: Chiang Mai strain) < 3.10 ± 0.32 (Form C: Chiang Mai strain) = 3.20 ± 0.42 (Form C: Mae Hong Son strain)], whereas the surface topography of eggs among the three strains of two karyotypic forms were morphologically similar.
Resumo:
Both hepatitis B and hepatitis C viruses (HBV and HCV) infection are common in HIV-infected individuals as a result of shared risk factors for acquisition. A serological study for HBV and HCV was performed in 251 HIV-positive individuals from Medellín, Colombia. A qualitative RT-PCR for HCV was done in 90 patients with CD4+ T-cell count < 150 per mm³. Serological markers for HBV infection were present in 97 (38.6%) patients. Thirty six of them (37.1%) had isolated anti-HBc. A multivariate analysis indicated that the following risk factors were significantly associated with the presence of these markers: age (OR = 1.05, 95% CI: 1.01-1.08), pediculosis pubis (OR = 1.83, 95% CI: 1.01-3.33), men who have sex with men and women (OR = 3.23, 95% CI: 1.46-7.13) and men who have sex only with men (OR = 3.73, 95% CI: 1.58-8.78). The same analysis restricted to women showed syphilis as the only significant risk factor. Thus, HBV infection was considerably associated with high risk sexual behavior. HCV was present in only two (0.8%) of HIV patients. Both of them were positive by RT-PCR and anti-HCV. This low frequency of HIV/HCV coinfection was probably due to the uncommon intravenous drug abuse in this population. The frequent finding of isolated anti-HBc warrants molecular approaches to rule out the presence of cryptic HBV infection.
Resumo:
Salivary gland proteins of the human malaria vector, Anopheles dirus B were determined and analyzed. The amount of salivary gland proteins in mosquitoes aged between 3 - 10 days was approximately 1.08 ± 0.04 µg/female and 0.1 ± 0.05 µg/male. The salivary glands of both sexes displayed the same morphological organization as that of other anopheline mosquitoes. In females, apyrase accumulated in the distal regions, whereas alpha-glucosidase was found in the proximal region of the lateral lobes. This differential distribution of the analyzed enzymes reflects specialization of different regions for sugar and blood feeding. SDS-PAGE analysis revealed that at least seven major proteins were found in the female salivary glands, of which each morphological region contained different major proteins. Similar electrophoretic protein profiles were detected comparing unfed and blood-fed mosquitoes, suggesting that there is no specific protein induced by blood. Two-dimensional polyacrylamide gel analysis showed the most abundant salivary gland protein, with a molecular mass of approximately 35 kilodaltons and an isoelectric point of approximately 4.0. These results provide basic information that would lead to further study on the role of salivary proteins of An. dirus B in disease transmission and hematophagy.
Resumo:
A reactivação do vírus da hepatite B em doentes com neoplasias hematológicas é uma complicação frequente da quimioterapia ou da terapêutica imunomoduladora. Os autores descrevem o caso dum doente com linfoma não-Hodgkin e história de infecção passada pelo VHB que desenvolveu hepatite fulminante após quimioterapia. Os mecanismos de reactivação do VHB são discutidos e as recomendações sobre profilaxia são apresentadas.