871 resultados para Attention degree


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: This study aimed at evaluating the degree of conversion (DC) of four composite resins, being one nanofilled and 3 microhybrid resins, photo-activated with second- and third-generation light-emitting diodes (LEDs). Material and methods: Filtek (TM) Z350 nanofilled composite resins and Amelogen (R) Plus, Vit-l-escence (TM) and Opallis microhybrid resins were photo-activated with two second-generation LEDs (Radii-cal and Elipar Free Light (TM) 2) and one third-generation LED (Ultra-Lume LED 5) by continuous light mode, and a quartz halogen-tungsten bulb (QHT, control). After 24 h of storage, the samples were pulverized into fine powder and 5 mg of each material were mixed with 100 mg of potassium bromide (KBr). After homogenization, they were pressed, which resulted in a pellet that was evaluated using an infrared spectromer (Nexus 470, Thermo Nicolet) equipped with TGS detector using diffuse reflectance (32 scans, resolution of 4 cm(-1)) coupled to a computer. The percentage of unreacted carbon-carbon double bonds (% C=C) was determined from the ratio of absorbance intensities of aliphatic C=C (peak at 1637 cm-1) against internal standard before and after curing of the specimen: aromatic C-C (peak at 1610 cm-1). Results: The ANOVA showed a significant effect on the interaction between the light-curing units (LCUs) and the composite resins (p<0.001). The Tukey's test showed that the nanofilled resin (Filtek (TM) Z350) and Opallis when photo-activated by the halogen lamp (QTH) had the lowest DC compared with the other microhybrid composite resins. The DC of the nanofilled resin (Filtek (TM) Z350) was also lower using LEDs. The highest degrees of conversion were obtained using the third-generation LED and one of second-generation LEDs (Elipar Free Light (TM) 2). Conclusions: The nanofilled resin showed the lowest DC, and the Vit-l-escence (TM) microhybrid composite resin showed the highest DC. Among the LCUs, it was not possible to establish an order, even though the second-generation LED Radii-cal provided the lowest DC.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Genus Scytodes includes most species of the spider family Scytodidae. Until now, 187 species of the genus have been described. In spite of this great diversity, only three Scytodes species were karyotyped so far. The present paper provides for the first time karyotype analysis of two synanthropic species, Scytodes fusca and Scytodes itapevi. Furthermore, new data on karyotype of Scytodes globula are also provided using conventional and differential cytogenetical procedures. The diploid number in the genus Scytodes varied considerably, namely from 2n = 13 to 2n = 31. The diploid number found in S. globula (2n male = 13) is the lowest in haplogyne spiders with monocentric chromosomes. Except S. globula, this number has been found only in one haplogyne spider with monocentric chromosomes, namely Ochyrocera sp. (Ochyroceratidae). on the contrary, the diploid number of S. fusca (2n male = 31) is one of the highest diploid numbers recorded in haplogyne spiders. The degree of intrageneric variation found in the genus Scytodes is the highest recorded in araneomorph spiders with monocentric chromosomes so far. Some karyotype characteristics (diploid number, chromosome morphology, total chromosome length, and distribution of constitutive heterochromatin) allowed us to postulate a close relationship between S. globula and S. itapevi. According to the karyotype data, S. fusca is not closely related to these two species. This conclusion corroborates a recent taxonomic work that grouped S. globula, S. itapevi, and other four Scytodes species in the 'globula group'.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

psi-Condensation of DNA fragments of about 4 kbp was induced by poly(ethylene glycol) (PEG), with degrees of polymerization ranging from 45 to 182, and univalent salt (NaCl). Using circular dichroism spectroscopy, we were able to accurately determine the critical amount of PEG needed to induce condensation, as a function of the NaCl concentration. A significant dependence on the PEG degree of polymerization was found. Phase boundaries determined for the multimolecular condensation were very similar to those observed previously for the monomolecular collapse, with two asymptotic regimes at low and high salt concentrations. We analyze our data using a theoretical model that properly takes into account both the polyelectrolyte nature of the DNA and the liquid crystallinity of the condensed phase. The model assumes that all PEG is excluded from the condensates and shows reentrant decondensation only at low salt. We also systematically study reentrant decondensation and find a very strong dependence on PEG molecular weight. At low PEG molecular weight, decondensation occurs at relatively low concentrations of PEG, and over a wide range of salt concentrations. This suggests that in the reentrant decondensation the flexible polymers used are not completely excluded from the condensed phase.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Let p be a prime number. A formula for the minimum absolute value of the discriminant of all Abelian extensions of Q of degree p(2) is given in terms of p.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: This study evaluated the degree of conversion (DC) of four indirect resin composites (IRCs) with various compositions processed in different polymerization units and investigated the effect of thermal aging on the flexural strength and Vicker's microhardness.Materials and Methods: Specimens were prepared from four IRC materials, namely Gr 1: Resilab (Wilcos); Gr2: Sinfony (3M ESPE); Gr3: VITA VMLC (VITA Zahnfabrik); Gr4: VITA Zeta (VITA Zahnfabrik) using special molds for flexural strength test (N = 80, n = 10 per group) (25 x 2 x 2 mm(3), ISO 4049), for Vicker's microhardness test (N = 80, n = 10 per group) (5 x 4 mm(2)) and for DC (N = 10) using FT-Raman Spectroscopy. For both flexural strength and microhardness tests, half of the specimens were randomly stored in distilled water at 37 degrees C for 24 hours (Groups 1 to 4), and the other half (Groups 5 to 8) were subjected to thermocycling (5000 cycles, 5 to 55 +/- 1 degrees C, dwell time: 30 seconds). Flexural strength was measured in a universal testing machine (crosshead speed: 0.8 mm/min). Microhardness test was performed at 50 g. The data were analyzed using one-way and two-way ANOVA and Tukey's test (alpha = 0.05). The correlation between flexural strength and microhardness was evaluated with Pearson's correlation test (alpha = 0.05).Results: A significant effect for the type of IRC and thermocycling was found (p = 0.001, p = 0.001) on the flexural strength results, but thermocycling did not significantly affect the microhardness results (p = 0.078). The interaction factors were significant for both flexural strength and microhardness parameters (p = 0.001 and 0.002, respectively). Thermocycling decreased the flexural strength of the three IRCs tested significantly (p < 0.05), except for VITA Zeta (106.3 +/- 9.1 to 97.2 +/- 14 MPa) (p > 0.05) when compared with nonthermocycled groups. Microhardness results of only Sinfony were significantly affected by thermocycling (25.1 +/- 2.1 to 31 +/- 3.3 Kg/mm(2)). DC values ranged between 63% and 81%, and were not significantly different between the IRCs (p > 0.05). While a positive correlation was found between flexural strength and microhardness without (r = 0.309) and with thermocycling (r = 0.100) for VITA VMLC, negative correlations were found for Resilab under the same conditions (r = -0.190 and -0.305, respectively) (Pearson's correlation coefficient).Conclusion: Although all four IRCs presented nonsignificant DC values, flexural strength and microhardness values varied between materials with and without thermocycling.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJETIVO: Analisar o perfil dos usuários de lentes de contato entre os estudantes de medicina da Faculdade de Medicina de Botucatu da Universidade Estadual Paulista - UNESP - Botucatu (SP), quanto à ametropia, à aquisição, aos cuidados e às complicações. MÉTODOS: Foi aplicado um questionário aos alunos do 1º ao 6º ano de Medicina da Faculdade de Medicina de Botucatu da Universidade Estadual Paulista - UNESP - Botucatu (SP), perfazendo um estudo analítico transversal. RESULTADOS: Foram 566 entrevistados. Destes, 155 (27,4%) usavam lente de contato. Das lentes de contato usadas, 94,8% eram gelatinosas, e em 98,7% o grau era negativo. O descarte dessas lentes era mensal em 46,9% dos entrevistados e 63,9% a utilizavam, em média, 14 horas/dia. Faziam aquisição da lente de contato em óptica ou farmácia 14,1% dos estudantes. Faziam a higiene ao colocá-las e ao retirá-las dos olhos, 46,5%. As complicações referentes aos olhos vermelhos eram 51,0%; 44,5%, embaçamento; e 42,6%, sensação de corpo estranho, além de 4 estudantes relatarem ceratite. CONCLUSÕES: A maioria dos alunos utilizava lentes hidrofílicas, descarte mensal e grau negativo. A adaptação inadequada, aquisição de lentes de contato em ópticas ou farmácias e complicações graves ocorreram, mesmo nos usuários socioculturalmente considerados diferenciados. em vista disso, demanda a extrema necessidade de maior atenção na abordagem do tema em questão, a fim de prevenir o comprometimento visual permanente.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The work describes the biocompatibility and biodegradation studies of anionic collagen membranes casted form collagen gels collagen, that were selective hydrolyzed at the carboxyamide groups, as a function of the degree of cross-links induced by glutaraldehyde. Independently from the degree of cross-links, all membranes studied were characterized by a similar inflammatory response, inversely dependent on glutaraldehyde reaction time, that decreased from the time of the implant. Cell alterations, mineralization or contact necrosis were not observed in any of the membranes studied. Rates for membrane tissue biodegradation were directly related to glutaraldehyde reaction time, and ranged from 30 to periods longer than 60 days, associated with good biocompatibility. Although other properties must be considered, their use in the treatment of periodontal diseases, the biological behavior observed with the 8 h GA cross-linked membrane suggests that, anionic collagen membrane described in this work may be of potential use, not only in association with guided tissue regeneration technique for periodontal tissue reconstruction, but also in other collagen biomaterial applications where controlled biodegradability is required. (C) 1998 Published by Elsevier B.V. Ltd. All rights reserved.