819 resultados para Artéria oftálmica


Relevância:

10.00% 10.00%

Publicador:

Resumo:

INTRODUCTION: Thiobarbituric acid-reactive substance is a marker of oxidative stress and has cytotoxic and genotoxic actions. C- reactive protein is used to evaluate the acute phase of inflammatory response. OBJECTIVES: To assess the thiobarbituric acid-reactive substance and C-reactive protein levels during extracorporeal circulation in patients submitted to cardiopulmonary bypass. METHODS: Twenty-five consecutive surgical patients (16 men and nine women; mean age 61.2 ± 9.7 years) with severe coronary artery disease diagnosed by angiography scheduled for myocardial revascularization surgery with extracorporeal circulation were selected. Blood samples were collected immediately before initializing extracorporeal circulation, T0; in 10 minutes, T10; and in 30 minutes, T30. RESULTS: The thiobarbituric acid-reactive substance levels increased after extracorporeal circulation (P=0.001), with average values in T0=1.5 ± 0.07; in T10=5.54 ± 0.35; and in T30=3.36 ± 0.29 mmoles/mg of serum protein. The C-reactive protein levels in T0 were negative in all samples; in T10 average was 0.96 ± 0.7 mg/dl; and in T30 average was 0.99 ± 0.76 mg/dl. There were no significant differences between the dosages in T10 and T30 (P=0.83). CONCLUSIONS: C-reactive protein and thiobarbituric acid-reactive substance plasma levels progressively increased during extracorporeal circulation, with maximum values of thiobarbituric acid-reactive substance at 10 min and of Creactive protein at 30 min. It suggests that there are an inflammatory response and oxidative stress during extracorporeal circulation.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJETIVO: A cirurgia de revascularização miocárdica (CRM) na fase aguda do infarto do miocárdio (IAM) está associada a aumento do risco operatório. O objetivo do estudo foi determinar fatores preditores de mortalidade intra-hospitalar nos pacientes submetidos a CRM no IAM. MÉTODOS: Durante três anos, todos os pacientes submetidos a CRM no IAM foram analisados retrospectivamente, utilizando o banco de dados institucional. Sessenta variáveis por paciente foram avaliadas: 49 variáveis pré-operatórias provenientes dos escores 2000 Bernstein-Parsonnet e EuroSCORE; 4 variáveis pré-operatórias não consideradas por esses escores (tempo entre o IAM e a CRM, valor máximo de CKMB, valor máximo de troponina e supradesnivelamento do segmento ST) e 7 variáveis intraoperatórias [uso de circulação extracorpórea (CEC), tempo de CEC, tipo de cardioplegia, endarterectomia, número de enxertos, uso da artéria torácica interna e revascularização completa]. Análise univariada e multivariada para o desfecho mortalidade intra-hospitalar foram realizadas. RESULTADOS: O tempo médio entre o IAM e a CRM foi de 3,8 ± 3 dias. A mortalidade global foi 19%. Na análise multivariada: idade > 65 anos [OR 16,5 (IC 1,8-152), P=0,013]~ CEC >108 minutos [OR 40 (IC 2,7-578), P=0,007], creatinina > 2 mg/dl [OR 35,5 (IC 1,7-740), P=0,021] e pressão pulmonar sistólica > 60 mmHg [OR 31(IC 1,6-591), P=0,022] foram preditores de mortalidade intra-hospitalar. CONCLUSÃO: Variáveis pré-operatórias clássicas como idade > 65 anos, creatinina > 2 mg/dl e pressão pulmonar sistólica > 60 mmHg foram preditoras de mortalidade intra-hospitalar nos pacientes operados de revascularização miocárdica na fase aguda do infarto.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJETIVO: Permanecem as controvérsias sobre a utilização de circulação extracorpórea (CEC) na cirurgia de revascularização miocárdica (CRM). O objetivo deste estudo foi avaliar o impacto do 2000 Bernstein Parsonnet (2000BP) e EuroSCORE (EU) para escolha de CEC na CRM. MÉTODOS: Foram submetidos à CRM 1.551 pacientes consecutivos. CEC foi utilizada em 1.121 (72,3%) pacientes. O desempenho do 2000BP e EU para a amostra foi avaliado mediante testes de calibração, discriminação e correlação. Para ambos os escores de risco, o aumento do valor do escore e a presença de CEC tiveram relação direta com maior chance de óbito (P<0,05). Portanto, com essas duas variáveis foi construído um modelo de regressão logística para cada escore de risco, com a finalidade de determinar em que valor do escore a presença de CEC aumenta significativamente a chance de óbito. RESULTADOS: A calibração, ao igual que a área abaixo da curva ROC para o grupo com CEC [2000BP=0,80; EU=0,78] e sem CEC [2000BP=0,81; EU=0,85] foram adequadas. A correlação de Spearman para os grupos com e sem CEC foi de 0,66 (P<0,001) e 0,62 (P<0,001), respectivamente. No 2000BP, para um valor>17,75, a presença de CEC aumentou a chance de óbito para 7,4 [IC95% (4,4-12,3), P<0,0001]. No EU, para um valor>4,5, a presença de CEC aumentou a chance de óbito para 5,4 [IC95% (3,3-9), P<0,0001]. CONCLUSÃO: Na tomada de decisões, o 2000BP>17,75 ou o EU>4,5 orientam a identificar pacientes que quando submetidos a CRM com CEC têm chance de óbito aumentada significativamente.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJETIVO: Para melhorar as propriedades mecânicas e imunogênicas, o glutaraldeído é utilizado no tratamento do pericárdio bovino que é utilizado em biopróteses. A liofilização do pericárdio bovino tratado com glutaraldeído diminui os radicais aldeído, com provável redução do potencial para calcificação. O objetivo deste estudo é avaliar os efeitos da liofilização em biopróteses valvares de pericárdio bovino como mecanismo protetor na diminuição da disfunção estrutural valvar. MÉTODOS: Foi realizado o implante de biopróteses de pericárdio bovino tratado com glutaraldeído, liofilizadas ou não, em carneiros de 6 meses de idade, sendo os animais eutanasiados com 3 meses de seguimento. As biopróteses foram implantadas em posição pulmonar, com auxílio de circulação extracorpórea. Um grupo controle e outro grupo liofilizado foram avaliados quanto ao gradiente ventrículo direito/artéria pulmonar (VD/AP) no implante e explante; análise quantitativa de cálcio; inflamação; trombose e pannus. O nível de significância estabelecido foi de 5%. RESULTADOS: O gradiente médio VD/AP, no grupo controle, no implante, foi 2,04 ± 1,56 mmHg e, no grupo de liofilização, foi 6,61 ± 4,03 mmHg. No explante, esse gradiente aumentou para 7,71 ± 3,92 mmHg e 8,24 ± 6,2 mmHg, respectivamente, nos grupos controle e liofilização. O teor de cálcio médio, após 3 meses, nas biopróteses do grupo controle foi 21,6 ± 39,12 µg Ca+2/mg de peso seco, em comparação com um teor médio de 41,19 ± 46,85 µg Ca+2/mg de peso seco no grupo liofilizado (P = 0,662). CONCLUSÃO: A liofilização de próteses valvares com pericárdio bovino tratado com glutaraldeído não demonstrou diminuição da calcificação neste experimento.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJETIVOS: Avaliação retrospectiva criteriosa de casos de reimplantes após amputação por avulsão. Avaliação de técnicas e táticas utilizadas que determinaram evolução satisfatória e bom resultado funcional. METÓDOS: Foram avaliados, retrospectivamente, prontuários de 43 pacientes que tiveram membros amputados por mecanismo de avulsão e reimplantados nos últimos 21 anos. RESULTADOS: A maior parte dos casos envolvia homens adultos jovens. A localização de amputação mais frequente foi do polegar. As técnicas e táticas cirúrgicas utilizadas isoladas ou conjuntamente incluem: enxertos de nervo, enxertos vasculares (veia ou artéria), transposição de feixe vascular digital, encurtamento do membro e reimplante heterotópico. A técnica mais frequentemente utilizada foi o emprego de enxertos venosos. A taxa de sobrevida dos reimplantes foi alta (93%), assim como a satisfação dos pacientes. CONCLUSÃO: Os reimplantes por mecanismo de avulsão dependem do correto diagnóstico de viabilidade anatômica e utilização de técnicas e táticas cirúrgicas apropriadas para cada caso. A experiência da equipe cirúrgica e estrutura hospitalar adequada são fundamentais para obtenção de bons resultados. Existem poucos relatos na literatura sobre indicação, tática, técnicas e resultados de procedimentos de reimplantes em amputações por avulsão. Acreditamos que a avaliação retrospectiva desta série de casos possa trazer novas informações e contribuições no atendimento desta situação de alta complexidade. Nível de evidência IV, Série de casos.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJETIVO: Avaliar a posição das estruturas anatômicas em risco durante a inserção de parafusos pediculares na coluna torácica e sua relação com a variação do ângulo de Cobb. MÉTODOS: Os parâmetros estudados foram: a medida do ângulo de Cobb nas radiografias e a posição da medula espinhal, da cavidade pleural e aorta na ressonância nuclear magnética em relação a uma linha de 40mm criada para simular o parafuso pedicular nas cinco vértebras apicais. RESULTADOS: A distância da aorta ao corpo vertebral e o ângulo de segurança do lado convexo apresentaram diferença estatística quando relacionados com a variação do ângulo de Cobb medido. CONCLUSÃO: Os resultados apresentados sugerem maior risco de lesão da artéria aorta com o aumento do ângulo de Cobb e aumento do risco na inserção de parafusos pediculares no lado convexo da curvatura, quando se considera o ângulo de segurança.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

INTRODUÇÃO: O choque cardiogênico é a maior causa de morte em pacientes com infarto agudo do miocárdio com supradesnivelamento do segmento de ST (IAMCSST). O presente estudo avaliou pacientes com IAMCSST e choque cardiogênico submetidos a intervenção coronária percutânea primária com o objetivo de estabelecer seu perfil e os preditores de mortalidade hospitalar. MÉTODOS: Registro unicêntrico, incluindo 100 pacientes avaliados no período de 2001 a 2009 quanto a características clínicas, angiográficas e do procedimento, e a desfechos intra-hospitalares. Por análise multivariada foram determinados preditores independentes da mortalidade hospitalar. RESULTADOS: Com relação às características clínicas, foi observada alta prevalência de fatores de risco, sendo a taxa de sucesso angiográfico de 92%, apesar da complexidade das lesões (83,1% do tipo B2/C). A artéria mais acometida foi a descendente anterior (45%), tendo o padrão multiarterial ocorrido em 73% dos casos. A taxa de mortalidade foi de 45%, sendo seus preditores independentes o padrão multiarterial [odds ratio (OR) 2,62; intervalo de confiança de 95% (IC 95%) 1,16-5,90] e o fluxo coronário TIMI < 3 ao final do procedimento (OR 2,11, IC 95% 1,48-3,02). CONCLUSÕES: Os pacientes com IAMCSST complicado por choque cardiogênico apresentaram características clínicas e angiográficas de alto risco e, apesar do alto sucesso angiográfico do procedimento, altas taxas de mortalidade. Foram preditores independentes de mortalidade o padrão multiarterial e fluxo TIMI < 3 ao final do procedimento.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

INTRODUÇÃO: Os estudos com stents farmacológicos têm avaliado predominantemente populações masculinas de descendência europeia. O estudo de braço único SPIRIT Women avalia o stent eluidor de everolimus XIENCE TM V em lesões de novo complexas em uma população feminina do mundo real, incluindo pacientes latino-americanas. Esta análise permite compreender como essa população responde ao implante de stent, comparativamente a pacientes não-latino-americanas. MÉTODOS: Das 1.572 pacientes matriculadas em 73 locais fora dos Estados Unidos, 138 (9%) foram recrutadas na Argentina, no Brasil e na Venezuela. RESULTADOS: As lesões-alvo tinham diâmetro de referência do vaso entre 2,25 mm e 4 mm e extensão da lesão ≤ 28 mm. As características basais foram semelhantes entre os grupos, com exceção de maior prevalência de hipertensão arterial, infarto do miocárdio (IM) de parede anterior e história familiar de doença arterial coronária na coorte latino-americana. As lesões tendiam a ser mais complexas em mulheres latino-americanas, com menor diâmetro de referência do vaso-alvo, maior extensão da lesão, maior excentricidade e angulação e mais lesões tipo B2/C. Os eventos foram adjudicados de acordo com as definições do Academic Research Consortium. Em um ano, o desfecho combinado de morte por todas as causas, IM e revascularização do vaso-alvo (RVA) foi de 12,1% na população não-latino-americana e de 10,1% na população latino-americana (P = 0,58). CONCLUSÕES: Em um ano, os baixos índices de eventos cardíacos adversos, incluindo trombose do stent, falha da lesão-alvo, morte cardíaca, IM e RVA nas mulheres latino-americanas foram comparáveis aos das mulheres não-latino-americanas, apesar da maior complexidade das lesões. Esses resultados demonstram a segurança e a eficácia do stent XIENCE TM V nessa pequena coorte de pacientes latino-americanas, à semelhança do que é observado com populações maiores e mais variadas.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

INTRODUÇÃO: Baseados na hipótese de que a neoíntima encontrada em stents farmacológicos (SFs) com polímeros biodegradáveis aos 28 dias não é a neoíntima definitiva e de que a tomografia de coerência óptica (TCO) é um método eficaz para a avaliação sequencial da neoíntima, objetivamos, neste estudo experimental, comparar os achados da TCO aos 28 dias e aos 90 dias em dois tipos de SF com polímeros biodegradáveis: o stent liberador de sirolimus (Inspiron®, Scitech) e o stent liberador de biolimus A9 (Biomatrix®, Biosensors International). MÉTODOS: No total, 6 porcos não-ateroscleróticos foram submetidos a implante de 6 stents Inspiron® e de 6 stents Biomatrix®. Cada porco recebeu os dois tipos de stent, um em cada artéria coronária (descendente anterior e circunflexa) e após 28 dias e 90 dias foram realizadas avaliações qualitativas intrastent a cada milímetro com TCO. RESULTADOS: A avaliação qualitativa, feita por pareamento milímetro a milímetro intrastent, evidenciou neoíntima heterogênea em 39% aos 28 dias e em 0% aos 90 dias, presença de tecido intraluminal em 18% aos 28 dias e em 0% aos 90 dias, irregularidade luminal em 62% aos 28 dias e em 2% aos 90 dias (P < 0,005). Não houve diferença entre os grupos quanto à qualidade da neoíntima ao longo do tempo (P > 0,05). CONCLUSÕES: Os achados à TCO corroboram a hipótese de que a neoíntima encontrada em SFs com polímeros biodegradáveis aos 28 dias não é a neoíntima definitiva. A evidência experimental mais significativa é a mudança das características da neoíntima observada à TCO sequencial.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The parenchymal distribution of the splenic artery was studied in order to obtain anatomical basis for partial splenectomy. Thirty two spleens were studied, 26 spleens of healthy horses weighing 320 to 450kg, aged 3 to 12 years and 6 spleens of fetus removed from slaughterhouse. The spleens were submitted to arteriography and scintigraphy in order to have their vascular pattern examined and compared to the external aspect of the organ aiming establish anatomo-surgical segments. All radiographs were photographed with a digital camera and the digital images were submitted to a measuring system for comparative analysis of areas of dorsal and ventral anatomo-surgical segments. Anatomical investigations into the angioarchitecture of the equine spleen showed a paucivascular area, which coincides with a thinner external area, allowing the organ to be divided in two anatomo-surgical segments of approximately 50% of the organ each.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Estudamos em 40 caprinos adultos da raça Bhuj Brasileira os aspectos histológicos do funículo espermático. Observamos que este se acha envolvido por uma cápsula de tecido conjuntivo fibroelástico denso, de espessura variável, pregueada em alguns pontos, e revestida por mesotélio que circunda todo o conjunto vásculo-nervoso, e projeta-se para formar o mesoducto deferente. Em posição subcapsular, verifica- se uma camada de tecido conjuntivo fibroelástico frouxo, de espessura variável, que circunda parcialmente o funículo espermático, isolando nas regiões deferencial e abdeferencial, conjuntos vásculo-nervosos, responsáveis pela nutrição do epidídimo. Na região do mesoducto deferente, o tecido subcapsular acompanhado de tecido adiposo constitui a camada interna deste meso, formando a sua adventícia e abrigando vasos e nervos deferenciais. Na região abdeferencial, pequenos acúmulos de tecido adiposo são vistos de permeio aos vasos e nervos desta região. Entre as artérias, veias e nervos testiculares, bem como entre os vasos das regiões deferencial e abdeferencial, observa-se o tecido conjuntivo denso, intervascular, rico em fibras elásticas, que constitui as adventícias contínuas destes vasos. O arranjo vascular mostra que o segmento da artéria testicular, contido no funículo espermático, apresenta trajeto sinuoso. Estando envolvido pelo plexo venoso pampiniforme, formado por veias testiculares desprovidas de válvulas de calibres variados, apresentando amplas comunicações entre si. As veias responsáveis pela drenagem do epidídimo e ducto deferente estão localizadas em posição subcapsular deferencial e abdeferencial e mostram-se providas de válvulas. O trato das artérias testiculares no funículo espermático apresenta como média e desvio padrão 134,6±38,1cm à direita, e 137,0±33,9cm à esquerda, não existindo diferenças estatisticamente significantes ao nível de 5%, quando comparamos a média do segmento da artéria testicular contida no funículo espermático direito em relação ao esquerdo.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objetivo: avaliar os efeitos de precondicionamento isquêmico remoto (PCI-R) no modelo de transplante de intestino delgado fetal. Métodos: foram constituídos dois grupos: transplante isogênico (Iso, camundongos C57BL/6, n=24) e transplante alogênico (Alo, camundongos BALB/c, n=24). Em cada grupo, distribuíram-se os animais com e sem PCI-R, que foi realizado por oclusão da artéria femoral esquerda da fêmea prenhe durante 10 minutos, seguida por tempo igual de reperfusão. O imunossupressor utilizado foi Tacrolimo (Fk, 5 mg/kg/dia v.o.). Ao final obteve-se os seguintes subgrupos: Alo-Tx, Alo-Pci, Alo-Fk, Alo-Pci-Fk, Iso-Tx, Iso-Pci, Iso-Fk e Iso-Pci-Fk. O enxerto foi transplantado no espaço entre o músculo reto-abdominal e pré- peritoneal dos receptores a meio centímetro do apêndice xifóide, à esquerda da linha mediana. Após o sétimo dia de seguimento, o enxerto foi removido, fixado e embebido em parafina para avaliação histomorfológica (desenvolvimento e rejeição) e análise imunohistoquímica (anti-PCNA e anti-caspase-3 clivada). Os dados foram analisados usando ANOVA e testes complementares e foi considerado significante quando p <0.05. Resultados: A avaliação do desenvolvimento do enxerto no grupo de Iso mostrou que o PCI-R reduziu o desenvolvimento comparado com Iso-Tx (5,2±0,4 vs 9,0±0,8), o Fk e sua associação com PCI-R aumentaram o desenvolvimento do enxerto comparado com PCI-R (11,2±0,7 e 10,2±0,8, respectivamente). No grupo Alo, o Fk e/ou sua associação com PCI-R aumentaram o desenvolvimento comparado com Alo-Tx e Alo com PCI-R (6,0±0,8, 9,0±1,2, 0,0±0,0, 0,5±0,3, respectivamente). A expressão de PCNA foi maior no grupo ISO em animais tratados com Fk e PCI-R comparados a outros grupos (12,2±0,8 vs Tx: 8,8±0,9, PCI-R: 8,0±0,4 e Fk: 9,0±0,6). No grupo Alo, a expressão de PCNA não diferiu entre grupos. A rejeição do enxerto foi menor nos grupos tratados com PCI-R (-18%), Fk (- 68%) ou ambos (-61%) comparados com Alo-Tx. A expressão de caspase-3 clivada foi menor no grupo Iso em animais tratados com associação de PCI-R e Fk (6,2 ±0,9 vs Tx: 8,6±0,5; PCI-R: 5,8 ±0,9 e Fk: 6,0 ±0,3). Conclusão: O PCIR mostrou efeito benéfico sobre a lesão de isquemia e reperfusão do enxerto intestinal fetal nos transplantes isogênico e alogênico, aumentando o número de células caliciformes e a proliferação celular. No transplante alogênico, aumentou o desenvolvimento do enxerto, diminuiu o grau de rejeição aguda na ausência de imunossupressão, porém não apresentou efeito sinérgico com o imunossupressor. No transplante isogênico houve diminuição do grau de desenvolvimento do enxerto, porém foi efetivo na redução da apoptose.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Introdução: A reposição volêmica em pacientes traumatizados tem sido controvérsa. O A.T.L.S. recomenda a infusão de um grande volume de fluidos na fase inicial de tratamento, enquanto outros autores recomendam a administração somente quando do controle da hemorragia. O acesso venoso femoral é contra indicado em pacientes com trauma abdominal por temor de aumento de hemorragia. A solução hipertônica de NaCl a 7,5% (SH) possui benefícios consideráveis de logística e de recuperação hemodinâmica com pequenos volumes de infusão, semelhante as vantagens das soluções padrões isotônicas na fase pré-hospitalar. Objetivos: Criar um modelo de choque hemorrágico induzido por trauma venoso. Avaliar a hemodinâmica e o volume de hemorragia abdominal nos animais submetidos a choque hemorrágico e tratados com SH via acesso femoral e jugular. Métodos: Em 18 porcos da raça landrace, divididos em 3 grupos de 6 animais (Controle, Jugular e Femoral), foi induzido um choque hipovolêmico não controlado pela ruptura da veia cava caudal. Os animais do grupo controle (GC) foram observados por 40 minutos quanto ao seu padrão hemodinâmico de Pressão de Artéria Pulmonar (PAP), Pressão Artérial Média (PAM), Débito Cardíaco (DC) e Fluxo de Veia Porta (FVP), porém sem reposição volêmica. Os animais dos grupos Femoral (GC) e Jugular (GJ) foram tratados com 4 ml/Kg de solução hipertônica de NaCl a 7,5% (SH) aos 20 minutos de experimento. Ao final do experimento, o volume de hemorragia abdominal foi mensurado.Resultados: O grupo controle (GC) apresentou queda dos valores hemodinâmicos aos 10 minutos e estes permaneceram estáveis até o final do experimento. Os animais dos grupos tratamento (GF e GJ) apresentaram melhora da hemodinâmica aos 30 minutos, sem aumento da hemorragia abdominal. Conclusão: A solução hipertônica de NaCl (SH) permitiu a melhora parcial da hemodinâmica no modelo de choque hipovolêmico, sem aumento da hemorragia, independentemente do acesso utilizada para a infusão.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A via de acesso arterial é um importante sítio de complicações após a realização de procedimentos coronários invasivos. Dentre as estratégias para a redução de complicações vasculares, encontra-se estabelecida a eficácia da técnica radial. Os dispositivos de oclusão vascular propiciam maior conforto ao paciente, reduzindo o tempo de hemostasia e repouso no leito. Entretanto, a inconsistência de dados comprovando sua segurança limita sua adoção rotineira como estratégia para redução de complicações vasculares, requerendo evidências de estudos randomizados com metodologia adequada. O objetivo deste estudo foi comparar a incidência de complicações no sítio de punção arterial entre a técnica radial e a técnica femoral com utilização de Angio-Seal em pacientes com síndrome coronariana aguda sem supradesnível do segmento ST submetidos à estratégia invasiva precoce. Trata-se de um ensaio clínico unicêntrico, de não inferioridade, no qual duzentos e quarenta pacientes foram randomizados para a técnica radial ou técnica femoral com utilização de Angio-Seal. O objetivo primário foi a ocorrência de complicações no sítio de punção arterial até 30 dias após o procedimento, incluindo sangramento grave, hematoma >= 5 cm, hematoma retroperitoneal, síndrome compartimental, pseudoaneurisma, fístula arteriovenosa, infecção, isquemia de membro, oclusão arterial, lesão de nervo adjacente ou necessidade de reparo vascular cirúrgico. Em relação às características demográficas e clínicas, houve diferença apenas quanto ao gênero, com presença maior de pacientes do sexo feminino no grupo radial (33,3% versus 20,0%, p=0,020). Não se observaram diferenças entre os grupos quanto ao diagnóstico de admissão, alterações isquêmicas presentes no eletrocardiograma, elevação de marcadores de necrose miocárdica ou escores de risco, bem como quanto à farmacoterapia antitrombótica adjunta e características da intervenção coronária percutânea. A hemostasia foi obtida na totalidade dos procedimentos do grupo radial com a utilização da pulseira compressora seletiva TR Band e em 95% dos procedimentos realizados pela técnica femoral com o Angio-Seal (p=0,029). Exceto pela maior incidência de oclusão arterial no grupo radial comparado ao femoral, não houve diferenças entre os demais desfechos analisados. Segundo o teste de não inferioridade para complicações na via de acesso arterial aos 30 dias, verificou-se que a utilização do Angio-Seal não produziu resultados inferiores ao acesso radial, considerando-se a margem de 15% (12,5% versus 13,3%, diferença -0,83%, IC 95% -9,31 - 7,65, p para não inferioridade <0,001). Os resultados principais deste estudo demonstram que, em uma população de pacientes com diagnóstico de síndrome coronariana aguda sem supradesnível do segmento ST, submetida à estratificação de risco invasiva, a utilização do dispositivo de oclusão vascular Angio-Seal confere ao procedimento efetivado pelo acesso femoral inferioridade na incidência de complicações no sítio de punção arterial aos 30 dias quando comparado ao acesso radial.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

INTRODUÇÃO: Durante procedimentos endovasculares, estão presentes os riscos relacionados ao uso dos contrastes iodados, tais como a nefropatia por contraste, uma vez que é fundamental o emprego de um meio de contraste para a obtenção das imagens radiológicas vasculares. A injeção intravascular de gás CO2 purificado é reconhecidamente uma alternativa relativamente mais segura ao contraste iodado, contudo, seu manuseio artesanal pode também trazer dificuldades técnicas e riscos aos pacientes. Para contemplar estas questões, foi desenvolvido o protótipo de um injetor intravascular de CO2 medicinal, microprocessado, dedicado à obtenção de imagens angiográficas. OBJETIVOS: Realizar os testes de viabilidade técnica inicial do protótipo em modelo in vivo. MÉTODOS: Realizar a angioplastia da artéria renal esquerda de 10 porcos, divididos em 2 grupos: Grupo 1 (n=5) injeção de contraste iodado, Grupo 2 (n=5) injeção de CO2 através do protótipo. Monitorização clínica e laboratorial dos animais no pré, intra e pós-operatório, com exames de função renal na véspera e 48h após os procedimentos e 3 gasometrias arteriais seriadas no intra-operatório. Observação clínica foi mantida por 48h no pós- operatório. RESULTADOS: Os procedimentos de angioplastia com CO2 foram realizados com sucesso técnico de 100%, sem necessidade de complementação com injeção de contraste iodado no Grupo 2. Não foram identificadas falhas no protótipo em funcionamento. Não foram identificadas alterações clínicas ou radiológicas sugestivas de contaminação por ar ambiente do sistema de CO2 e nem alterações laboratoriais nos animais. As imagens angiográficas obtidas no Grupo 2 foram consideradas, numa avaliação subjetiva, relativamente inferiores às imagens obtidas no Grupo 1. DISCUSSÃO: A qualidade inferior de imagem no Grupo 2 pode ser atribuída ao equipamento de fluoroscopia utilizado, com software desatualizado em relação aos equipamentos atuais, que incluem pré-configurações para angiografia com CO2; no entanto, ainda assim todos os procedimentos propostos no Grupo 2 foram realizados com sucesso técnico, o que nos leva a classificar as imagens deste grupo 2 como satisfatórias. O manuseio do aparelho mostrou-se ágil e eficiente, com a programação dos parâmetros sendo realizada com facilidade através do visor \"touch screen\", comparativamente superior ao método artesanal de injeção de CO2 com seringas em selo d\'água. CONCLUSÕES: O protótipo do aparelho injetor intravascular de CO2 funcionou de forma adequada durante os testes e as imagens obtidas permitiram a compleição com sucesso dos procedimentos. Portanto, os resultados positivos obtidos sugerem que o equipamento é tecnicamente viável