986 resultados para ASSISTED THORACIC-SURGERY
Resumo:
OBJECT In ventriculoperitoneal (VP) shunt surgery, laparoscopic assistance can be used for placement of the peritoneal catheter. Until now, the efficacy of laparoscopic shunt placement has been investigated only in retrospective and nonrandomized prospective studies, which have reported decreased distal shunt dysfunction rates in patients undergoing laparascopic placement compared with mini-laparotomy cohorts. In this randomized controlled trial the authors compared rates of shunt failure in patients who underwent laparoscopic surgery for peritoneal catheter placement with rates in patients who underwent traditional mini-laparotomy. METHODS One hundred twenty patients scheduled for VP shunt surgery were randomized to laparoscopic surgery or mini-laparotomy for insertion of the peritoneal catheter. The primary endpoint was the rate of overall shunt complication or failure within the first 12 months after surgery. Secondary endpoints were distal shunt failure, overall complication/ failure, duration of surgery and hospitalization, and morbidity. RESULTS The overall shunt complication/failure rate was 15% (9 of 60 cases) in the laparoscopic group and 18.3% (11 of 60 cases) in the mini-laparotomy group (p = 0.404). Patients in the laparoscopic group had no distal shunt failures; in contrast, 5 (8%) of 60 patients in the mini-laparotomy group experienced distal shunt failure (p = 0.029). Intraoperative complications occurred in 2 patients (both in the laparoscopic group), and abdominal pain led to catheter removal in 1 patient per group. Infections occurred in 1 patient in the laparoscopic group and 3 in the mini-laparotomy group. The mean durations of surgery and hospitalization were similar in the 2 groups. CONCLUSIONS While overall shunt failure rates were similar in the 2 groups, the use of laparoscopic shunt placement significantly reduced the rate of distal shunt failure compared with mini-laparotomy.
Resumo:
BACKGROUND During 2007 and 2008 it is likely that millions of patients in the US received heparin contaminated (CH) with oversulfated chondroitin sulfate, which was associated with anaphylactoid reactions. We tested the hypothesis that CH was associated with serious morbidity, mortality, intensive care unit (ICU) stay and heparin-induced thrombocytopenia following adult cardiac surgery. METHODS AND FINDINGS We conducted a single center, retrospective, propensity-matched cohort study during the period of CH and the equivalent time frame in the three preceding or the two following years. Perioperative data were obtained from the institutional record of the Society of Thoracic Surgeons National Database, for which the data collection is prospective, standardized and performed by independent investigators. After matching, logistic regression was performed to evaluate the independent effect of CH on the composite adverse outcome (myocardial infarction, stroke, pneumonia, dialysis, cardiac arrest) and on mortality. Cox regression was used to determine the association between CH and ICU length of stay. The 1∶5 matched groups included 220 patients potentially exposed to CH and 918 controls. There were more adverse outcomes in the exposed cohort (20.9% versus 12.0%; difference = 8.9%; 95% CI 3.6% to 15.1%, P < 0.001) with an odds ratio for CH of 2.0 (95% CI, 1.4 to 3.0, P < 0.001). In the exposed group there was a non-significant increase in mortality (5.9% versus 3.5%, difference = 2.4%; 95% CI, -0.4 to 3.5%, P = 0.1), the median ICU stay was longer by 14.1 hours (interquartile range -26.6 to 79.8, S = 3299, P = 0.0004) with an estimated hazard ratio for CH of 1.2 (95% CI, 1.0 to 1.4, P = 0.04). There was no difference in nadir platelet counts between cohorts. CONCLUSIONS The results from this single center study suggest the possibility that contaminated heparin might have contributed to serious morbidity following cardiac surgery.
Resumo:
HYPOTHESIS To evaluate the feasibility and the results of insertion of two types of electrode arrays in a robotically assisted surgical approach. BACKGROUND Recent publications demonstrated that robot-assisted surgery allows the implantation of free-fitting electrode arrays through a cochleostomy drilled via a narrow bony tunnel (DCA). We investigated if electrode arrays from different manufacturers could be used with this approach. METHODS Cone-beam CT imaging was performed on fivecadaveric heads after placement of fiducial screws. Relevant anatomical structures were segmented and the DCA trajectory, including the position of the cochleostomy, was defined to target the center of the scala tympani while reducing the risk of lesions to the facial nerve. Med-El Flex 28 and Cochlear CI422 electrodes were implanted on both sides, and their position was verified by cone-beam CT. Finally, temporal bones were dissected to assess the occurrence of damage to anatomical structures during DCA drilling. RESULTS The cochleostomy site was directed in the scala tympani in 9 of 10 cases. The insertion of electrode arrays was successful in 19 of 20 attempts. No facial nerve damage was observed. The average difference between the planned and the postoperative trajectory was 0.17 ± 0.19 mm at the level of the facial nerve. The average depth of insertion was 305.5 ± 55.2 and 243 ± 32.1 degrees with Med-El and Cochlear arrays, respectively. CONCLUSIONS Robot-assisted surgery is a reliable tool to allow cochlear implantation through a cochleostomy. Technical solutions must be developed to improve the electrode array insertion using this approach.
Resumo:
We present a case of successful interventional laser-assisted extraction of an endovascularly trapped long-term implanted ventriculoatrial shunt in a patient with shunt-associated septicemia. This approach is based on modified techniques for explantation of pacemaker leads and might be considered an additional option for extraction of otherwise nonremovable trapped endovascular catheters in experienced centers.
Resumo:
PURPOSE To evaluate a low-cost, inertial sensor-based surgical navigation solution for periacetabular osteotomy (PAO) surgery without the line-of-sight impediment. METHODS Two commercial inertial measurement units (IMU, Xsens Technologies, The Netherlands), are attached to a patient's pelvis and to the acetabular fragment, respectively. Registration of the patient with a pre-operatively acquired computer model is done by recording the orientation of the patient's anterior pelvic plane (APP) using one IMU. A custom-designed device is used to record the orientation of the APP in the reference coordinate system of the IMU. After registration, the two sensors are mounted to the patient's pelvis and acetabular fragment, respectively. Once the initial position is recorded, the orientation is measured and displayed on a computer screen. A patient-specific computer model generated from a pre-operatively acquired computed tomography scan is used to visualize the updated orientation of the acetabular fragment. RESULTS Experiments with plastic bones (eight hip joints) performed in an operating room comparing a previously developed optical navigation system with our inertial-based navigation system showed no statistically significant difference on the measurement of acetabular component reorientation. In all eight hip joints the mean absolute difference was below four degrees. CONCLUSION Using two commercially available inertial measurement units we show that it is possible to accurately measure the orientation (inclination and anteversion) of the acetabular fragment during PAO surgery and therefore to successfully eliminate the line-of-sight impediment that optical navigation systems have.
Resumo:
CONTEXT Enhanced Recovery after Surgery (ERAS) programs are multimodal care pathways that aim to decrease intra-operative blood loss, decrease postoperative complications, and reduce recovery times. OBJECTIVE To overview the use and key elements of ERAS pathways, and define needs for future clinical trials. EVIDENCE ACQUISITION A comprehensive systematic MEDLINE search was performed for English language reports published before May 2015 using the terms "postoperative period," "postoperative care," "enhanced recovery after surgery," "enhanced recovery," "accelerated recovery," "fast track recovery," "recovery program," "recovery pathway", "ERAS," and "urology" or "cystectomy" or "urologic surgery." EVIDENCE SYNTHESIS We identified 18 eligible articles. Patient counseling, physical conditioning, avoiding excessive alcohol and smoking, and good nutrition appeared to protect against postoperative complications. Fasting from solid food for only 6h and perioperative liquid-carbohydrate loading up to 2h prior to surgery appeared to be safe and reduced recovery times. Restricted, balanced, and goal-directed fluid replacement is effective when individualized, depending on patient morbidity and surgical procedure. Decreased intraoperative blood loss may be achieved by several measures. Deep vein thrombosis prophylaxis, antibiotic prophylaxis, and thermoregulation were found to help reduce postsurgical complications, as was a multimodal approach to postoperative nausea, vomiting, and analgesia. Chewing gum, prokinetic agents, oral laxatives, and an early resumption to normal diet appear to aid faster return to normal bowel function. Further studies should compare anesthetic protocols, refine analgesia, and evaluate the importance of robot-assisted surgery and the need/timing for drains and catheters. CONCLUSIONS ERAS regimens are multidisciplinary, multimodal pathways that optimize postoperative recovery. PATIENT SUMMARY This review provides an overview of the use and key elements of Enhanced Recovery after Surgery programs, which are multimodal, multidisciplinary care pathways that aim to optimize postoperative recovery. Additional conclusions include identifying effective procedures within Enhanced Recovery after Surgery programs and defining needs for future clinical trials.
Resumo:
Background In patients with autoimmune diseases associated with antiphospholipid antibodies, precise management of anticoagulation during extracorporeal circulation (ECC) is complicated. It was the aim of the present study to determine whether antifactor Xa (aXa) activity is useful in guiding heparin therapy during ECC. Methods In 15 patients undergoing cardiac surgery, anticoagulation with unfractionated heparin (UFH) and its reversal with protamine were guided using activated clotting time (ACT) (>400 second during ECC; ≤100 second for UFH reversal). For each ACT, the corresponding aXa activity levels were measured. Results A total of 144 blood samples were obtained. ACT and aXa activity were significantly correlated (r = 0.771, p< 0.0001, Spearman rank-order correlation). Using receiver operating characteristic curve (ROC) analyses, the cutoffvalues for aXa activity were 1.14 IU/mL (area under the ROC curve [AUC]: 0.89; inaccuracy rate: 9.4%) to predict ACT > 400 seconds and 0.55 IU/mL (AUC: 0.85; inaccuracy rate: 13.3%) for ACT ≤ 100 seconds. Conclusion AXa activity is strongly correlated with ACT, and therefore may be feasible for managing anticoagulation with UFH during ECC.
Resumo:
Laparoscopic instrument tracking systems are an essential component in image-guided interventions and offer new possibilities to improve and automate objective assessment methods of surgical skills. In this study we present our system design to apply a third generation optical pose tracker (Micron- Tracker®) to laparoscopic practice. A technical evaluation of this design is performed in order to analyze its accuracy in computing the laparoscopic instrument tip position. Results show a stable fluctuation error over the entire analyzed workspace. The relative position errors are 1.776±1.675 mm, 1.817±1.762 mm, 1.854±1.740 mm, 2.455±2.164 mm, 2.545±2.496 mm, 2.764±2.342 mm, 2.512±2.493 mm for distances of 50, 100, 150, 200, 250, 300, and 350 mm, respectively. The accumulated distance error increases with the measured distance. The instrument inclination covered by the system is high, from 90 to 7.5 degrees. The system reports a low positional accuracy for the instrument tip.
Resumo:
Interacting with a computer system in the operating room (OR) can be a frustrating experience for a surgeon, who currently has to verbally delegate to an assistant every computer interaction task. This indirect mode of interaction is time consuming, error prone and can lead to poor usability of OR computer systems. This thesis describes the design and evaluation of a joystick-like device that allows direct surgeon control of the computer in the OR. The device was tested extensively in comparison to a mouse and delegated dictation with seven surgeons, eleven residents, and five graduate students. The device contains no electronic parts, is easy to use, is unobtrusive, has no physical connection to the computer and makes use of an existing tool in the OR. We performed a user study to determine its effectiveness in allowing a user to perform all the tasks they would be expected to perform on an OR computer system during a computer-assisted surgery. Dictation was found to be superior to the joystick in qualitative measures, but the joystick was preferred over dictation in user satisfaction responses. The mouse outperformed both joystick and dictation, but it is not a readily accepted modality in the OR.
Resumo:
PURPOSE: This study has been undertaken to audit a single-center experience with laparoscopically-assisted resection rectopexy for full-thickness rectal prolapse. The clinical Outcomes and long-term results were evaluated. METHODS: The data were prospectively collected for the duration of the operation, time to passage of flatus postoperatively, hospital stay, morbidity, and mortality. For follow-up, patients received a questionnaire or were contacted. The data were divided into quartiles over the study period, and the differences in operating time and length of hospital stay were tested using the Kruskal-Wallis test. RESULTS: Between March 1992 and October 2003, a total of 117 patients underwent laparoscopic resection rectopexy for rectal prolapse. The median operating time during the first quartile (representing the early experience) was 180 minutes compared with 110 minutes for the fourth quartile (Kruskal-Wallis test for operating time = 35.523, 3 df, P < 0.0001). Overall morbidity was 9 percent (ten patients), with one death (< 1 percent). One patient had a ureteric injury requiring conversion. One minor anastomotic leak Occurred, necessitating laparoscopic evacuation of a pelvic abscess. Altogether, 77 patients were available for follow-up. The median follow-up was 62 months. Eighty percent of the patients reported alleviation of their symptoms after the operation. Sixty-nine percent of the constipated patients experienced an improvement in bowel frequency. No patient had new or worsening symptoms of constipation after Surgery. Two (2.5 percent) patients had full-thickness rectal prolapse recurrence. Mucosal prolapse recurred in 14 (18 percent) patients. Anastomotic dilation was performed for stricture in five (4 percent) patients. CONCLUSIONS: Laparoscopically-assisted resection rectopexy for rectal prolapse provides a favorable functional outcome and low recurrence rate. Shorter operating time is achieved with experience. The minimally invasive technique benefits should be considered when offering rectal prolapse patients a transabdominal approach for repair, and emphasis should now be on advanced training in the laparoscopic approach.
Resumo:
To study the visual and refractive outcomes after laser-assisted subepithelial keratectomy (LASEK) performed with a 213 nm solid-state laser for a broad range of refractive errors.