865 resultados para ASSEMBLY SYSTEM-DESIGN


Relevância:

40.00% 40.00%

Publicador:

Resumo:

National High Technology Research and Development Program of China 2007AA03Z112;Program of Ministry of Education of China 20060183030;Program of Jilin Provincial Science and Technology Department of China 20070709;Program of Bureau of Science and Technology of Changchun City 2007107

Relevância:

40.00% 40.00%

Publicador:

Resumo:

A complete set of match calculation methods for optimum sizing of PV/wind hybrid system is presented. In this method, the more accurate and practical mathematic models for characterizing PV module, wind generator and battery are adopted; combining with hourly measured meteorologic data and load data, the performance of a PV/wind hybrid system is determined on a hourly basis; by fixing the capacity of wind generators, the whole year's LPSP (loss of power supply probability) values of PV/wind hybrid systems with different capacity of PV array and battery bank are calculated, then the trade-off curve between battery bank and PV array capacity is drawn for the given LPSP value; the optimum configuration which can meet the energy demand with the minimum cost can be found by drawing a tangent to the trade-off curve with the slope representing the relationship between cost of PV module and that of the battery. According to this match calculation method, a set of match calculation programs for optimum sizing of PV/wind hybrid systems have been developed. Applying these match calculation programs to an assumed PV/wind hybrid system to be installed at Waglan island of Hong Kong, the optimum configuration and its hourly, daily, monthly and yearly performances are given. (C) 2003 Elsevier Science Ltd. All rights reserved.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Systems design involves the determination of interdependent variables. Thus the precedence ordering for the tasks of determining these variables involves circuits. Circuits require planning decisions abut how to iterate and where to use estimates. Conventional planning techniques, such as critical path, do not deal with these problems. Techniques are shown in this paper which acknowledge these circuits in the design of systems. These techniques can be used to develop an effective engineering plan, showing where estimates are to be used, how design iterations and reviews are handled, and how information flows during the design work.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The integrated pilot-scale dimethyl ether (DME) synthesis system from corncob was demonstrated for modernizing utilization of biomass residues. The raw bio-syngas was obtained by the pyrolyzer/gasifier at the yield rate of 40-45 Nm(3)/h. The content of tar in the raw bio-syngas was decreased to less than 20 mg/Nm(3) by high temperature gasification of the pyrolysates under O-2-rich air. More than 70% CO2 in the raw bio-syngas was removed by pressure-swing adsorption unit (PSA). The bio-syngas (H-2/CO approximate to 1) was catalytically converted to DME in the fixed-bed tubular reactor directly over Cu/Zn/Al/HZSM-5 catalysts. CO conversion and space-time yield of DME were in the range of 82.0-73.6% and 124.3-203.8 kg/m(cat)(3)/h, respectively, with a similar DME selectivity when gas hourly space velocity (GHSV, volumetric flow rate of syngas at STP divided by the volume of catalyst) increased from 650 h(-1) to 1500 h(-1) at 260 degrees C and 4.3 MPa. And the selectivity to methanol and C-2(+) products was less than 0.65% under typical synthesis condition. The thermal energy conversion efficiency was ca. 32.0% and about 16.4% carbon in dried corncob was essentially converted to DME with the production cost of ca. (sic) 3737/ton DME. Cu (111) was assumed to be the active phase for DME synthesis, confirmed by X-ray diffraction (XRD) characterization.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Based on the optimized design of the lattice for therapy synchrotron and considering the requirement of radiation therapy, the third order resonant extraction is adopted. Using the momentum-amplitude selection method, the extraction system is designed and optimized. An extraction efficiency of more than 97% and a momentum spread less than 0.11% are obtained.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Abstract A state-of-the-art high energy heavy ion microbeam irradiation system is constructed at the Institute of Modern Physics of the Chinese Academy of Sciences. This microbeam system operates in both full current intensity mode and single ion mode. It delivers a predefined number of ions to preselected targets for research in biology and material science. The characteristic of this microbeam system is high energy and vertical irradiation. A quadrupole focusing system, in combination with a series of slits, has been designed to optimize the spatial resolution. A symmetrically achromatic system leads the beam downwards and serves simultaneously as an energy analyzer. A high gradient quadrupole triplet finally focuses a C6+ ion beam to 1 µm in the vacuum chamber within the energy range from 10 MeV/u to 100 MeV/u. In this paper, the IMP microbeam system is described in detail. A systematic investigation of the ion beam optics of this microbeam system is presented together with the associated aberrations. Comparison is made between the IMP microbeam system and the other existing systems to further discuss the performance of this microbeam. Then the optimized initial beam parameters are given for high resolution and high hitting efficiency. At last, the experiment platform is briefly introduced.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

An advanced superconducting ECR ion source named SECRAL has been constructed at Institute of Modern Physics of Chinese Academy of Sciences, whose superconducting magnet assembly consists of three axial solenoid coils and six sextupole coils with a cold iron structure as field booster and clamp. In order to investigate the structure of sextupole coils and to increase the structural reliabilities of the magnet system, global and local structural analysis have been performed in various operation scenarios. Winding pack and support structure design of magnet system, mechanical calculation and stress analysis are given in this paper. From the analysis results, it has been found that the magnet system is safe in the referential operation scenarios and the configuration of the magnet complies with design requirements of the SECRAL.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Respiration-induced target motion is a major problem in intensity-modulated radiation therapy. Beam segments are delivered serially to form the total dose distribution. In the presence of motion, the spatial relation between dose deposition from different segments will be lost. Usually, this results in over-and underdosage. Besides such interplay effects between target motion and dynamic beam delivery as known from photon therapy, changes in internal density have an impact on delivered dose for intensity-modulated charged particle therapy. In this study, we have analysed interplay effects between raster scanned carbon ion beams and target motion. Furthermore, the potential of an online motion strategy was assessed in several simulations. An extended version of the clinical treatment planning software was used to calculate dose distributions to moving targets with and without motion compensation. For motion compensation, each individual ion pencil beam tracked the planned target position in the lateral aswell as longitudinal direction. Target translations and rotations, including changes in internal density, were simulated. Target motion simulating breathing resulted in severe degradation of delivered dose distributions. For example, for motion amplitudes of +/- 15 mm, only 47% of the target volume received 80% of the planned dose. Unpredictability of resulting dose distributions was demonstrated by varying motion parameters. On the other hand, motion compensation allowed for dose distributions for moving targets comparable to those for static targets. Even limited compensation precision (standard deviation similar to 2 mm), introduced to simulate possible limitations of real-time target tracking, resulted in less than 3% loss in dose homogeneity.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The HIRFL (Heavy Ion Research Facility at Lanzhou) is a cyclotron complex. Its injector is a cector focusing cyclotron with K=69. Since the HIRFL started the operation in 1989, two bigger items of improvements have been finished, the species and intensity of the accelerated particles are increased obviously. But due to the lower extraction efficiency of the SFC, on one hand, a lot of beam lost, and on other hand, outgas from the surface of the electrostatic deflector is serious because of beam hitting. Even sometimes the vacuum press is destroyed. In the paper a new physical design is made to get an extraction system of the SFC with a higher efficiency.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

设计了一种应用于兰州重离子加速器注入器的电源控制器,该控制器基于微处理器AT-mega128,结合MAX7000系列的复杂可编程器件和RTL8019AS网关芯片来实现对电源系统的控制,并通过RS-232总线实现与上位机的串口通信。应用结果表明,该控制器具有良好的通用性、灵活性、可远程控制及性能稳定等特点,实现了注入器磁铁电源10-4量级的幅度稳定性,使注入器引出的束流强度、束流品质、束流稳定性和供束效率等得到很大的提高。

Relevância:

40.00% 40.00%

Publicador:

Resumo:

介绍了在CSR同步加速器高频控制系统改进项目中,高频前端控制器的改进设计。根据系统改进的具体要求,采用DSP+FPGA双电路板的体系结构,对高频前端控制器各个部分做了详细的设计,并给出了具体的资源消耗结果和设计图。

Relevância:

40.00% 40.00%

Publicador:

Resumo:

介绍了兰州重离子加速器冷却储存环(HIRFL-CSR)的实验环(CSRe)团簇内靶装置控制系统的设计。该内靶系统由多种设备构成,包括喷嘴测温与加热控制子系统、真空与阀门监测/控制子系统、分子泵监测与控制子系统、数据处理与流程软件子系统等部分。该系统在内靶实验中工作状态良好,满足了内靶实验的需求。在该控制系统的支持下,2010年1月第一轮辐射电子俘获物理实验顺利完成。