996 resultados para wall material
Resumo:
As the requirement for agriculture to be environmentally suitable there is a necessity to adopt indicators and methodologies approaching sustainability. In Brazil, biodiesel addition into diesel is mandatory and soybean oil is its main source. The material embodiment determines the convergence of inputs into the crop. Moreover, the material flows are necessary for any environmental analysis. This study evaluated distinct production scenarios, and also conventional versus GMO crops, through the material embodiment and energy analysis. GMO crops demanded less indirectly applied inputs. The energy balance showed linearity with yield, whereas for EROI, the increases in input and yield were not affected.
Resumo:
Neste trabalho, objetivou-se ajustar curvas de perda na pressão estática do ar, quando forçado em camadas de material orgânico, com diferentes espessuras, e dois estádios de degradação bioquímica, para possibilitar o cálculo da demanda de potência do sistema de ventilação. Os resíduos utilizados para a medição da perda de pressão do ar foram cama de frango misturada com casca dos frutos do cafeeiro, razão entre massas de 2,5:1, de forma a se obter relação C/N inicial de 30:1. Foi verificado que a perda na pressão estática do ar aumentou linearmente com a espessura da camada de composto orgânico e que houve aumento na perda de pressão estática com o aumento na vazão específica do ar, o que praticamente não foi alterado pelo estádio de degradação bioquímica do material em compostagem. Todos os modelos testados (potencial, logarítmico e quadrático) ajustaram-se bem aos dados experimentais, na faixa de vazão específica de ar entre 0,045 e 0,159 m³ s-1 m-2, podendo ser usado para predizer os gradientes de pressão estática no composto orgânico. A potência demandada pelo sistema de ventilação foi de 1,16 W t-1 no material, antes da compostagem, e de 2,38 W t-1, após 60 dias de compostagem, em camada com 1 m de espessura. Em camada de 2 m de espessura, a demanda foi de 17,70 e 21,65 W t-1, respectivamente.
Resumo:
Attempting to associate waste treatment to the production of clean and renewable energy, this research sought to evaluate the biological production of hydrogen using wastewater from the cassava starch treatment industry, generated during the processes of extraction and purification of starch. This experiment was carried out in a continuous anaerobic reactor with a working volume of 3L, with bamboo stems as the support medium. The system was operated at a temperature of 36°C, an initial pH of 6.0 and under variations of organic load. The highest rate of hydrogen production, of 1.1 L.d-1.L-1, was obtained with application of an organic loading rate of 35 g.L-1.d-1, in terms of total sugar content and hydraulic retention time of 3h, with a prevalence of butyric and acetic acids as final products of the fermentation process. Low C/N ratios contributed to the excessive growth of the biomass, causing a reduction of up to 35% in hydrogen production, low percentages of H2 and high concentrations of CO2in the biogas.
Resumo:
Estudo conduzido com o objetivo de avaliar a confiabilidade, acurácia e dificuldades do exame de congelação, utilizando-se pequenos fragmentos de tumores mamários obtidos com a biópsia histológica por agulha grossa (bioptycut). Durante 13 meses, 37 pacientes foram submetidas ao Bioptycut (pistola BIP 2.2 ou Promag 1.2, agulhas l4G), sendo que, de cada uma delas, foram retirados no mínimo dois fragmentos, um a fresco para congelação e outro submerso em formol para inclusão posterior em parafina. O estudo de congelação constituiu-se de exame citológico do "imprimir" da peça e de exame histológico usando cortes através de congelação. Os cortes foram feitos usando criostato e micrótomo, com cortes de 8µ. O tamanho do tumor puncionado variou de 1cm a 12cm (média 4,8cm). A congelação foi conclusiva em 33 casos (89%), sendo trinta carcinomas e três benignos, e inconclusiva em quatro casos (11%). A obtenção deste dia:nóstico se deu pelo "imprint" e corte em 29 casos (78%), só pelo "imprint" em quatro casos (11 %), em dois casos tanto o corte quanto o "imprint" foram inadequados e dois não foram descritos. Posteriormente foram obtidas peças por exérese da lesão (até a análise) em 28 casos, dos quais 25 carcinomas e três tumores benignos (11 %). Houve um caso de congelação conclusiva de benignidade, em que a exérese posterior revelou se tratar de carcinoma (falso-negativo). Não houve falsos-positivos. A sensibilidade foi de 96% e a especificidade de 100%. Assim, conclui-se que o exame por congelação, usando-se peças obtidas com bioptycut se mostrou confiável, evitando biópsias abertas em 81 % dos casos, garantindo rapidez e melhor preparo das pacientes para terapêutica definitiva.
Resumo:
This thesis focuses on tissue inhibitor of metalloproteinases 4 (TIMP4) which is the newest member of a small gene and protein family of four closely related endogenous inhibitors of extracellular matrix (ECM) degrading enzymes. Existing data on TIMP4 suggested that it exhibits a more restricted expression pattern than the other TIMPs with high expression levels in heart, brain, ovary and skeletal muscle. These observations and the fact that the ECM is of special importance to provide the cardiovascular system with structural strength combined with elasticity and distensibility, prompted the present molecular biologic investigation on TIMP4. In the first part of the study the murine Timp4 gene was cloned and characterized in detail. The structure of murine Timp4 genomic locus resembles that in other species and of the other Timps. The highest Timp4 expression was detected in heart, ovary and brain. As the expression pattern of Timp4 gives only limited information about its role in physiology and pathology, Timp4 knockout mice were generated next. The analysis of Timp4 knockout mice revealed that Timp4 deficiency has no obvious effect on the development, growth or fertility of mice. Therefore, Timp4 deficient mice were challenged using available cardiovascular models, i.e. experimental cardiac pressure overload and myocardial infarction. In the former model, Timp4 deficiency was found to be compensated by Timp2 overexpression, whereas in the myocardial infarct model, Timp4 deficiency resulted in increased mortality due to increased susceptibility for cardiac rupture. In the wound healing model, Timp4 deficiency was shown to result in transient retardation of re-epithelialization of cutaneous wounds. Melanoma tumor growth was similar in Timp4 deficient and control mice. Despite of this, lung metastasis of melanoma cells was significantly increased in Timp4 null mice. In an attempt to translate the current findings to patient material, TIMP4 expression was studied in human specimens representing different inflammatory cardiovascular pathologies, i.e. giant cell arteritis, atherosclerotic coronary arteries and heart allografts exhibiting signs of chronic rejection. The results showed that cardiovascular expression of TIMP4 is elevated particularly in areas exhibiting inflammation. The results of the present studies suggest that TIMP4 has a special role in the regulation of tissue repair processes in the heart, and also in healing wounds and metastases. Furthermore, evidence is provided suggesting the usefulness of TIMP4 as a novel systemic marker for vascular inflammation.
Resumo:
The objective is to alert the surgeon about the indiscriminate use of synthetic prosthesis in the correction of inguinal and incisional hernias. The authors provide a brief history of surgery on hernias and a review of the literature, showing the importance of classifying inguinal hernias to fit the type of surgical correction with the defect found, abstaining from treating all hernias, with the same type of surgical procedure. In our opinion, small indirect inguinal hernias (type 1 and 2 of Gilbert) and hernias in women must not, in general, be treated with prostheses. The synthetic material should be reserved for direct and large indirect hernias. Even so, this attitude, besides determining a higher cost for the procedure, can lead to important complications such as infection, rejection, fistula formation, chronic pain, alterations in spermatogenesis and the possibility of carcinogenesis, according to more recent reports. The physiology and anatomy of the abdominal wall should be considered when dealing with incisional hernia corrections, where the surgeon can choose among many techniques to correct those defects, and in selected cases, utilize synthetic material. We conclude that although the use of biomaterials has constituted a great advance in surgery for abdominal wall hernia corrections because they decrease recurrences, and permit treatment of large abdominal hernias, the indiscriminate prosthesis usage is an abuse, and it can determine many serious complications, certainly avoidable with a well indicated non mesh technique .
Resumo:
Acquired chest wall defects present a challenging problem for thoracic surgeons. Many of such defects can be repaired with the use of local and regional musculocutaneous flaps, but larger defects compromising skeletal structure require increasingly sophisticated reconstructive techniques. The following discussion will review the options for repair acquired chest wall defects based in literature. The authors searched the Pubmed (www.pubmed.com) and found citations from January 1996 to February 2008. By reading the titles and the abstracts most of the citations were discharged because they focused in congenital chest wall defects or were cases report. However, many papers were found describing the outcome of large series of patients with acquired chest wall deformities. A review of recent literature shows that the repair of chest wall defects with soft tissues, if possible, remains the treatment of choice. Large chest wall defects require skeletal reconstruction to prevent paradoxical respiration. The selection of the most appropriate flap is primary dictated by the location and the size of the defect. It is important to transfer tissue with good vitality, so understanding the vascular supply is imperative. Autogenous grafts have been used in the past for skeletal reconstruction but a combination of synthetic materials with musculocutaneous flaps has been used lately. Based in the literature, the use of prosthetic material in chest wall reconstruction does not significantly increases the risk of wound infection.
Resumo:
OBJETIVO: avaliar os acidentes com material biológico entre estudantes de medicina estagiando em um pronto-socorro de trauma e identificar as principais situações relacionadas, causas atribuídas e prevenção. MÉTODOS: estudo com abordagem quantitativa. Os dados foram coletados através de um questionário, aplicado via internet, contendo perguntas fechadas de escolha múltipla, referentes a acidentes com material biológico. A amostra obtida foi 100 estudantes. RESULTADOS: trinta e dois se acidentaram com materiais biológicos. As atividades de maior risco foram anestesia local (39,47%), sutura (18,42%) e recapeamento de agulha (15,79%). As principais vias de exposição ao material biológico foram contato com olho ou mucosa, com 34%, através de seringa com agulha com 45%. Após a contaminação, apenas 52% notificaram o acidente ao setor responsável. CONCLUSÃO: as principais causas de acidente encontradas e vias de exposição podem ser atribuídas a diversos fatores, como falta de treinamento e ao não uso de equipamentos de proteção individual. Ações preventivas e educativas são de extrema importância para diminuir a incidência dos acidentes com materiais biológicos e melhorar a conduta pós-exposição. É preciso entender as principais causas atribuídas e situações relacionadas a fim de implantar medidas gerais e eficazes.
Resumo:
The meeting of the Publication "Evidence Based Telemedicine - Trauma and Emergency Surgery" (TBE-CiTE), through literature review, selected three recent articles on the treatment of victims stab wounds to the abdominal wall. The first study looked at the role of computed tomography (CT) in the treatment of patients with stab wounds to the abdominal wall. The second examined the use of laparoscopy over serial physical examinations to evaluate patients in need of laparotomy. The third did a review of surgical exploration of the abdominal wound, use of diagnostic peritoneal lavage and CT for the early identification of significant lesions and the best time for intervention. There was consensus to laparotomy in the presence of hemodynamic instability or signs of peritonitis, or evisceration. The wound should be explored under local anesthesia and if there is no injury to the aponeurosis the patient can be discharged. In the presence of penetration into the abdominal cavity, serial abdominal examinations are safe without CT. Laparoscopy is well indicated when there is doubt about any intracavitary lesion, in centers experienced in this method.
Resumo:
The authors detail the experimental development of a technique for the reconstruction of the ureter using a tubular shape, muscle flap of the abdominal wall. the preliminary results indicate the feasibility of this surgical technique.
Resumo:
OBJECTIVE: to present our experience with scheduled reoperations in 15 patients with intra-abdominal sepsis. METHODS: we have applied a more effective technique consisting of temporary abdominal closure with a nylon mesh sheet containing a zipper. We performed reoperations in the operating room under general anesthesia at an average interval of 84 hours. The revision consisted of debridement of necrotic material and vigorous lavage of the involved peritoneal area. The mean age of patients was 38.7 years (range, 15 to 72 years); 11 patients were male, and four were female. RESULTS: forty percent of infections were due to necrotizing pancreatitis. Sixty percent were due to perforation of the intestinal viscus secondary to inflammation, vascular occlusion or trauma. We performed a total of 48 reoperations, an average of 3.2 surgeries per patient. The mesh-zipper device was left in place for an average of 13 days. An intestinal ostomy was present adjacent to the zipper in four patients and did not present a problem for patient management. Mortality was 26.6%. No fistulas resulted from this technique. When intra-abdominal disease was under control, the mesh-zipper device was removed, and the fascia was closed in all patients. In three patients, the wound was closed primarily, and in 12 it was allowed to close by secondary intent. Two patients developed hernia; one was incisional and one was in the drain incision. CONCLUSION: the planned reoperation for manual lavage and debridement of the abdomen through a nylon mesh-zipper combination was rapid, simple, and well-tolerated. It permitted effective management of severe septic peritonitis, easy wound care and primary closure of the abdominal wall.
Resumo:
OBJECTIVE: to evaluate the efficacy of the amniotic membrane used with polypropylene mesh against the formation of adhesions and its influence on healing. METHODS: twenty five female Wistar rats were anesthetized for creating a parietal defect in the anterior abdominal wall. Its correction was made with polypropylene mesh alone and associated with amniotic membrane. In the control group (n=11), the screen was inserted alone. In group A (n=7) we interposed the amniotic membrane between the screen and the abdominal wall. In group B, the amniotic membrane was placed on the mesh, covering it. After seven days, the animals were euthanized for macroscopic and microscopic evaluation of healing. RESULTS: adhesions were observed in all animals except one in the control group. Severe inflammation was observed in all animals in groups A and B and in three of the control group, with significant difference between them (A and B with p=0.01). Pronounced angiogenic activity was noted in one animal in the control group, six in group A and four in group B, with a significant difference between the control group and group A (p=0.002) and group B (p=0.05). The scar collagen was predominantly mature, except in five animals of the control group, with significant difference between the control group and group A (p=0.05) and group B (p=0.05). CONCLUSION: The amniotic membrane did not alter the formation of adhesions in the first postoperative week. There were also pronounced inflammation, high angiogenic activity and predominance of mature collagen fibers, regardless of the anatomical plane that it was inserted in.
Resumo:
Objective: To analyze the performance of two surgical meshes of different compositions during the defect healing process of the abdominal wall of rats. Methods: thirty-three adult Wistar rats were anesthetized and subjected to removal of an area of 1.5 cm x 2 cm of the anterior abdominal wall, except for the skin; 17 animals had the defect corrected by edge-to-edge surgical suture of a mesh made of polypropylene + poliglecaprone (Group U - UltraproTM); 16 animals had the defect corrected with a surgical mesh made of polypropylene + polidioxanone + cellulose (Group P - ProceedTM). Each group was divided into two subgroups, according to the euthanasia moment (seven days or 28 days after the operation). Parameters analyzed were macroscopic (adherence), microscopic (quantification of mature and immature collagen) and tensiometric (maximum tension and maximum rupture strength). Results : there was an increase in collagen type I in the ProceedTM group from seven to 28 days, p = 0.047. Also, there was an increase in the rupture tension on both groups when comparing the two periods. There was a lower rupture tension and tissue deformity with ProceedTM mesh in seven days, becoming equal at day 28. Conclusion : the meshes retain similarities in the final result and more studies with larger numbers of animals must be carried for better assessment.
Resumo:
Objective: to discuss the participation of Plastic Surgery in the reconstruction of the chest wall, highlighting relevant aspects of interdisciplinaryness. Methods: we analyzed charts from 20 patients who underwent extensive resection of the thoracic integument, between 2000 and 2014, recording the indication of resection, the extent and depth of the raw areas, types of reconstructions performed and complications. Results: among the 20 patients, averaging 55 years old, five were males and 15 females. They resections were: one squamous cell carcinoma, two basal cell carcinomas, five chondrosarcomas and 12 breast tumors. The extent of the bloody areas ranged from 4x9 cm to 25x40 cm. In 12 patients the resection included the muscular plane. In the remaining eight, the tumor removal achieved a total wall thickness. For reconstruction we used: one muscular flap associated with skin grafting, nine flaps and ten regional fasciocutaneous flaps. Two patients undergoing reconstruction with fasciocutaneous flaps had partially suffering of the flap, solved with employment of a myocutaneous flap. The other patients displayed no complications with the techniques used, requiring only one surgery. Conclusion: the proper assessment of local tissues and flaps available for reconstruction, in addition to the successful integration of Plastic Surgery with the specialties involved in the treatment, enable extensive resections of the chest wall and reconstructions that provide patient recovery.
Resumo:
The Repair of segmental defects in load-bearing long bones is a challenging task because of the diversity of the load affecting the area; axial, bending, shearing and torsional forces all come together to test the stability/integrity of the bone. The natural biomechanical requirements for bone restorative materials include strength to withstand heavy loads, and adaptivity to conform into a biological environment without disturbing or damaging it. Fiber-reinforced composite (FRC) materials have shown promise, as metals and ceramics have been too rigid, and polymers alone are lacking in strength which is needed for restoration. The versatility of the fiber-reinforced composites also allows tailoring of the composite to meet the multitude of bone properties in the skeleton. The attachment and incorporation of a bone substitute to bone has been advanced by different surface modification methods. Most often this is achieved by the creation of surface texture, which allows bone growth, onto the substitute, creating a mechanical interlocking. Another method is to alter the chemical properties of the surface to create bonding with the bone – for example with a hydroxyapatite (HA) or a bioactive glass (BG) coating. A novel fiber-reinforced composite implant material with a porous surface was developed for bone substitution purposes in load-bearing applications. The material’s biomechanical properties were tailored with unidirectional fiber reinforcement to match the strength of cortical bone. To advance bone growth onto the material, an optimal surface porosity was created by a dissolution process, and an addition of bioactive glass to the material was explored. The effects of dissolution and orientation of the fiber reinforcement were also evaluated for bone-bonding purposes. The Biological response to the implant material was evaluated in a cell culture study to assure the safety of the materials combined. To test the material’s properties in a clinical setting, an animal model was used. A critical-size bone defect in a rabbit’s tibia was used to test the material in a load-bearing application, with short- and long-term follow-up, and a histological evaluation of the incorporation to the host bone. The biomechanical results of the study showed that the material is durable and the tailoring of the properties can be reproduced reliably. The Biological response - ex vivo - to the created surface structure favours the attachment and growth of bone cells, with the additional benefit of bioactive glass appearing on the surface. No toxic reactions to possible agents leaching from the material could be detected in the cell culture study when compared to a nontoxic control material. The mechanical interlocking was enhanced - as expected - with the porosity, whereas the reinforcing fibers protruding from the surface of the implant gave additional strength when tested in a bone-bonding model. Animal experiments verified that the material is capable of withstanding load-bearing conditions in prolonged use without breaking of the material or creating stress shielding effects to the host bone. A Histological examination verified the enhanced incorporation to host bone with an abundance of bone growth onto and over the material. This was achieved with minimal tissue reactions to a foreign body. An FRC implant with surface porosity displays potential in the field of reconstructive surgery, especially regarding large bone defects with high demands on strength and shape retention in load-bearing areas or flat bones such as facial / cranial bones. The benefits of modifying the strength of the material and adjusting the surface properties with fiber reinforcement and bone-bonding additives to meet the requirements of different bone qualities are still to be fully discovered.