1000 resultados para stars: imaging
Resumo:
We present observations of two new single-lined eclipsing binaries, both consisting of an Am star and an M-dwarf, discovered by the Wide Angle Search for Planets transit photometry survey. Using WASP photometry and spectroscopic measurements we find that HD 186753B has an orbital period of P=1.9194 days, a mass of M=0.24±0.02~M? and radius of R=0.31+0.06-0.06~R?; and that TCY7096-222-1B has an orbital period of P=8.9582 days, a mass of between 0.29 and 0.54 M? depending on eccentricity and radius of R=0.263+0.02-0.07~R?. We find that the Am stars have relatively low rotational velocities that closely match the orbital velocities of the M-dwarfs, suggesting that they have been “spun-down” by the M-dwarfs.
Resumo:
The synthesis and photophysical evaluation of a new supramolecular lanthanide complex is described which was developed as a luminescent contrast agent for bone structure analysis. We show that the Eu(III) emission of this complex is not pH dependent within the physiological pH range, and that its steady state emission is not significantly modulated by a series of group I and II as well as d-metal ions, and that this agent can be successfully employed to image mechanically formed cracks (scratches) in bone samples after 4 or 24 hours, using confocal laser-scanning microscopy.
Resumo:
The use of a water-soluble, thermo-responsive polymer as a highly sensitive fluorescence-lifetime probe of microfluidic temperature is demonstrated. The fluorescence lifetime of poly(N-isopropylacrylamide) labelled with a benzofurazan fluorophore is shown to have a steep dependence on temperature around the polymer phase transition and the photophysical origin of this response is established. The use of this unusual fluorescent probe in conjunction with fluorescence lifetime imaging microscopy (FLIM) enables the spatial variation of temperature in a microfluidic device to be mapped, on the micron scale, with a resolution of less than 0.1 degrees C. This represents an increase in temperature resolution of an order of magnitude over that achieved previously by FLIM of temperature-sensitive dyes
Resumo:
The authors discuss the imaging properties and transfer of amplitude and phase-modulated signals through a phase conjugating lens (PCL). The authors outline the mechanisms of the near-field and far-field subwavelength imaging of Hertzian dipole sources using PCL, particularly the authors show that one-dimensional subwavelength resolution of multiple sources is possible in the far-field using a PCL augmented with specially designed scatterers located in both the adjacent vicinity of the sources and in the mirror symmetric positions in the image plane. These scatterers enable evanescent-to-propagating spectrum and its dual, propagating-to-evanescent, field conversion. Thus, the subwavelength information encoded into propagating waves on the source side can be extracted on the image side. Next, for the first time the transfer of amplitude and phase modulated signals through a PCL augmented with evanescent-to-propagating spectrum conversion is discussed and it has been demonstrated that multiple amplitude or phase modulated dipole sources can be distinguished in the far-field with subwavelength resolution without the necessity for numerical post-processing of the received data. From the study conducted here, it is concluded that a system of transmitters/receivers augmented with a PCL and appropriate scatterers operates without the need for any numerical processing of the receive data in order to separate channel information from very close proximity stations.
Resumo:
Near-infrared (NIR) imaging was used to observe water vapour flow in a gas-solid fluidized bed reactor. The technique consisted of a broadband light, an optical filter with a bandwidth centred on strong water vapour absorptions, a Vidicon NIR camera, a nozzle from which an optically active mixture of gas and water vapour was trans-illuminated by an NIR beam and collected data of transmittance were normalized to actual optical path. The procedure was applied to a thin fluidized bed reactor with a low aspect ratio of tube to particle diameters (D-1/d(p)) in order to validate the wall effect on flow dynamics and mass transfer during the reduction of ceria-silica by hydrogen. High concentrations of water vapour emerged in the vicinity of the wall when the bed was operated at pseudo-static conditions but disappeared when the bed was run at minimum bubbling conditions. This result shows the capability of optical methods with affordable costs to 2D imaging opaque packed bed by using a spatially resolved probe located at the exit, which is of great benefit for in situ visualization of anisotropic concentrations in packed beds under industrially relevant conditions and thus for elucidation of the underlying reaction mechanism and diffusion interactions. Crown Copyright (c) 2011 Published by Elsevier B.V. All rights reserved.