945 resultados para sintagma nominal


Relevância:

10.00% 10.00%

Publicador:

Resumo:

High energy band gap hosts doped with lanthanide ions are suitable for optical devices applications To study the potential of Ta(2)O(5) as a host compound pure and Eu(2)O(3)-doped Ta(2)O(5) crystal fibers were grown by the laser-heated pedestal growth technique in diameters ranging from 250 to 2600 pm and in lengths of up to 50 mm The axial temperature gradient at the solid/liquid interface of pure Ta(2)O(5) fibers revealed a critical diameter of 2200 gm above which the fiber cracks X-ray diffraction measurements of the pure Ta(2)O(5) single crystals showed a monoclinic symmetry and a growth direction of [1 (1) over bar 0] An analysis of the pulling rate as a function of the fiber diameter for Eu(2)O(3)-doped Ta(2)O(5) fibers indicated a well defined region in which constitutional supercooling is absent Photoluminescence measurements of pure Ta(2)O(5) crystals using excitation above the band gap (3 8 eV) were dominated by a broad unstructured green band that peaked at 500 nm Three Eu(3+)-related optical centers were identified in the doped samples with nominal concentrations exceeding 1 mol% Two of these centers were consistent with the ion in the monoclinic phase with different oxygen coordinations The third one was visible in the presence of the triclinic phase (C) 2010 Elsevier B V All rights reserved

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The local structure of an ion-conducting glass with nominal composition 50B(2)O(3)-10PbO-40LiF has been investigated by complementary (7)Li, (11)B, (19)F, and (207)Pb single- and double-resonance experiments. The results give insight into the structural role of the lithium fluoride additive in borate glasses: (1) LiF is seen to actively participate in the network transformation process contributing to the conversion of three- into four-coordinate boron units, as shown by (11)B single-resonance as well as by (11)B{(19)F} and (19)F{(11)B} double-resonance experiments. (2) (19)F signal quantification experiments suggest substantial fluoride loss, presumably caused by formation of volatile BF(3). A part of the fluoride remains in the dopant role, possibly in the form of small LiF-like cluster domains, which serve as a mobile ion supply. (3) The extent of lithium-fluorine and lead-fluorine interactions has been characterized by (7)Li{(19)F} and (207)Pb{(19)F} REDOR and SEDOR experiments. On the basis of these results, a quantitative structural description of this system has been developed.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Biochemical responses in bivalve mollusks are commonly employed in environmental studies as biomarkers of aquatic contamination. The present study evaluated the possible influence of salinity (35, 25,15 and 9 ppt) in the biomarker responses of Crassostrea gigas oysters exposed to diesel at different nominal concentrations (0.01, 0.1 and 1 mLL(-1)) using a semi-static exposure system. Salinity alone did not resulted in major changes in the gill`s catalase activity (CAT), glutathione S-transferase activity (GST) and lipid peroxidation levels (measured as malondialdehyde. MDA), but influenced diesel related responses. At 25 ppt salinity, but not at the other salinity levels, oysters exposed to diesel showed a strikingly positive concentration-dependent GST response. At 25 ppt and 1 mLL(-1) diesel, the GST activity in the gills remained elevated, even after one week of depuration in clean water. The increased MDA levels in the oysters exposed to diesel comparing to control groups at 9, 15 and 35 ppt salinities suggest the occurrence of lipid peroxidation in those salinities, but not at 25 ppt salinity. The MDA quickly returned to basal levels after 24 h of depuration. CAT activity was unaltered by the treatments employed. High toxicity for 1 mLL(-1) diesel was observed only at 35 ppt salinity, but not in the other salinities. Results from this study strongly suggest that salinity influences the diesel related biomarker responses and toxicity in C. gigas, and that some of those responses remain altered even after depuration. (C) 2011 Elsevier B.V. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This study presents the results of the degradation of the pesticide atrazine using electrochemical and photo-assisted electrochemical degradation techniques using SnO(2)-containing electrode of nominal composition electrodes of composition Ti/Ru(x)Sni-(x)O(2) (where X = 0.10, 0.15, 0.20, 0.25 and 0.30). The materials were characterized ex situ and in situ in order to correlate the observed atrazine removal rates with electrode morphology/composition. The results obtained demonstrate the effectiveness of the photo-assisted electrochemical degradation. Using purely electrochemical methods the rate of atrazine removal is almost zero at all the electrodes studied. However, the application of photo-assisted degradation results in almost complete atrazine removal in 1 h of electrolysis. The efficiency of atrazine degradation does not seem to be greatly affected by the electrode material or by SnO(2) content, but the overall COD removal is dependent on the SnO(2) content. Overall, the SnO(2)-containing electrodes do not reach the level of COD removal (maximum similar to 21%) seen for the Ti/Ru(0.3)Ti(0.2)O(2) electrode. An interesting correlation between the morphology factor (phi) and chemical oxygen demand removal is observed. (C) 2010 Elsevier B.V. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper presents a degradation study of the pesticide atrazine using photo-assisted electrochemical methods at a dimensionally stable anode (DSA (R)) of nominal composition Ti/Ru(0.3)Ti(0.7)O(2) in a prototype reactor. The effects of current density, electrolyte flow-rate, as well as the use of different atrazine concentrations are reported. The results indicate that the energy consumption is substantially reduced for the combined photochemical and electrochemical processes when compared to the isolated systems. It is observed that complete atrazine removal is achieved at low current densities when using the combined method, thus reducing the energy required to operate the electrochemical system. The results also include the investigation of the phytotoxicity of the treated solutions.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Platinum stepped surfaces vicinal to the (1 1 0) crystallographic pole have been investigated voltammetrically in 0.1 M HClO(4) and 0.1 M H(2)SO(4) solutions. Changes in the voltammetric profile with the step density suggest the existence of two types of surface sites, that has been ascribed to linear and bidimensional domains. This result indicates the existence of important restructuring processes that separate the real surface distribution from the nominal one. The electronic properties of the surfaces have been characterized with the CO charge displacement method and the potential of zero total charge has been calculated as a function of the step density. (c) 2009 Elsevier B.V. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The occurrence of pauses and hesitations in spontaneous speech has been shown to occur systematically, for example, "between sentences, after discourse markers and conjunctions and before accented content words." (Hansson [15]) This is certainly plausible in English, where pauses and hesitations can and often do occur before content words such as nominals, for example, "uh, there's a … man." (Chafe [8]) However, if hesitations are, in fact, evidence of "deciding what to talk about next," (Chafe [8]) then the complex grammatical system of German should render this pausing position precarious, since pre-modifiers must account for the gender of the nominals they modify.In this paper, I present data to test the hypothesis that pre-nominal hesitation patterns in German are dissimilar to those in English. Hesitations in German will be shown, in fact, to occur within noun phrase units. Nevertheless, native speakers most often succeed in supplying a nominal which conforms to the gender indicated by the determiner or pre-modifier. Corrections, or repairs, of infelicitous pre-modifiers indicate that the speaker was unable to supply a nominal of the same gender which the choice of pre-modifier had committed him/her to. The frequency of such repairs is shown to vary according to task, with fewest repairs occurring in elicited speech which allows for linguistic freedom and therefore is most like spontaneous speech. The data sets indicate that among German native speakers, hesitations occurring before noun phrase units (pre-NPU hesitations) indicate deliberation of what to say, while hesitations within or before the head of the noun phrase (pre-NPH hesitations) indicate deliberation of how to say what has already been decided (cf. Chafe [8]).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this study was to investigate how electricallyheated houses can be converted to using wood pellet and solarheating. There are a large number of wood pellet stoves on themarket. Many stoves have a water jacket, which gives anopportunity to distribute the heat to domestic hot water and aradiator heating system. Three typical Swedish houses with electric resistanceheating have been studied. Fourteen different system conceptsusing wood pellet stoves and solar heating systems have beenevaluated. The systems and the houses have been simulated indetail using TRNSYS. The houses have been divided in up to 10different zones and heat transfer by air circulation throughdoorways and open doors have been simulated. The pellet stoveswere simulated using a recently developed TRNSYS component,which models the start- and stop phases, emissions and thedynamic behaviour of the stoves. The model also calculates theCO-emissions. Simulations were made with one stove without awater jacket and two stoves with different fractions of thegenerated heat distributed in the water circuit. Simulations show that the electricity savings using a pelletstove are greatly affected by the house plan, the systemchoice, if the internal doors are open or closed and thedesired level of comfort. Installing a stove with awater-jacket connected to a radiator system and a hot waterstorage has the advantage that heat can be transferred todomestic hot water and be distributed to other rooms. Suchsystems lead to greater electricity savings, especially inhouses having a traditional layout. It was found that not allrooms needed radiators and that it was more effective in mostcases t use a stove with a higher fraction of the heatdistributed by the water circuit. The economic investigation shows that installing a woodpellet stove without a water jacket gives the lowest totalenergy- and capital costs in the house with an open plan (fortoday's energy prices and the simulated comfort criteria). Inthe houses with a traditional layout a pellet stove givesslightly higher costs than the reference house having onlyelectrical resistance heating due to the fact that less heatingcan be replaced. The concepts including stoves with a waterjacket all give higher costs than the reference system, but theconcept closest to be economical is a system with a bufferstore, a stove with a high fraction of the heat distributed bythe water circuit, a new water radiator heating system and asolar collector. Losses from stoves can be divided into: flue gas lossesincluding leakage air flow when the stove is not in operation;losses during start and stop phases; and losses due to a highair factor. An increased efficiency of the stoves is importantboth from a private economical point of view, but also from theperspective that there can be a lack of bio fuel in the nearfuture also in Sweden. From this point of view it is alsoimportant to utilize as much solar heat as possible. Theutilization of solar heat is low in the simulated systems,depending on the lack of space for a large buffer store. The simulations have shown that the annual efficiency ismuch lower that the nominal efficiency at full power. Thesimulations have also shown that changing the control principlefor the stove can improve efficiency and reduce theCO-emissions. Today's most common control principle for stovesis the on/off control, which results in many starts and stopsand thereby high CO-emissions. A more advanced control varyingthe heating rate from maximum to minimum to keep a constantroom temperature reduces the number of starts and stops andthereby the emissions. Also the efficiency can be higher withsuch a control, and the room temperature will be kept at a moreconstant temperature providing a higher comfort.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The overall purpose of this study is to gain knowledge about dialogues in the setting of the preschool. The more in-depth purpose is to highlight what happens in dialogues between a teacher and a child when more children join the situation of interaction in which the dialogue is taking place. A further purpose is to attempt to understand what it is that influences change in the dialogue and what significance the actions of the teacher can have for this change. The study is based on several questions that concern interaction in preschools, who it is that initiates an increase in the number of participants in those situations that involve dialogue, and what happens with the dialogue when more children join and what causes the change in the dialogue. The study is based on video observations from a preschool; approximately 10 teachers and 50 children between the ages of one and six took part in the study. The situations that were observed and documented in video format were everyday activities (both indoor and outdoor) that were led at a nominal level by teachers. In total, 40 films were recorded. Film length was between one and 60 minutes. In 32 of the films, there was interaction between a teacher and several children, and 18 of these included dialogues between a teacher and several children. Dialogue is here given a specific significance and refers to the interaction that can be described in terms of presence, listening, reciprocity, and extending. This definition of dialogue derives from a combination of Martin Buber’s philosophy of dialogue and aspects of interaction that earlier research found to be significant for children’s learning. In two of the 18 films that showed dialogue, no other children became part of the situation of interaction; the remaining 16 films were transcribed; and both verbal and non-verbal events were made apparent in the transcriptions. Analyses of the recorded material and of the transcriptions were conducted using analytical terms borrowed from conversation analysis as well as the central term for this study dialogue.  The results demonstrate a complex practice and also demonstrate that dialogues in the sense given in this study take place between children and teachers. Situations of interaction also occur where dialogues take place in which a number of children join. It can be the child joining the situation of interaction who takes the initiative to an increased number of participants; however, it can also be the teacher or the child in the dialogue. The initial address can take place during a moment of transition in the interaction or at the same time as another participant is talking. The dialogue often changes when more children join the situation where the dialogue is taking place. The dialogue can end completely or be interrupted and resume. The results further demonstrate that the dialogue can continue without seemingly being affected by the fact that more children join. This happens when the child joining and the teacher in the dialogue interact in a non-verbal manner at the same time as the teacher is talking with the child in the dialogue. The dialogue can also be continued with more participants. Who takes the initiative, how the initial address occurs, and which content is given focus by the different participants are all factors that seem to affect what happens to the dialogue. How the teacher acts when more children join also appears to be significant in terms of what happens with the dialogue when more children join. In those situations where the teacher begins talking with a number of children about different subjects, the interaction ceases to be dialogic. When the teacher asks the joining child to wait, the dialogue is both interrupted and resumed, and on those occasions when the dialogue continues with more participants, the teacher listens to the joining child and the participants take turns speaking.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In this thesis the solar part of a large grid-connected photovoltaic system design has been done. The main purpose was to size and optimize the system and to present figures helping to evaluate the prospective project rationality, which can potentially be constructed on a contaminated area in Falun. The methodology consisted in PV market study and component selection, site analysis and defining suitable area for solar installation; and system configuration optimization based on PVsyst simulations and Levelized Cost of Energy calculations. The procedure was mainly divided on two parts, preliminary and detailed sizing. In the first part the objective was complex, which included the investigation of the most profitable component combination and system optimization due to tilt and row distance. It was done by simulating systems with different components and orientations, which were sized for the same 100kW inverter in order to make a fair comparison. For each simulated result a simplified LCOE calculation procedure was applied. The main results of this part show that with the price of 0.43 €/Wp thin-film modules were the most cost effective solution for the case with a great advantage over crystalline type in terms of financial attractiveness. From the results of the preliminary study it was possible to select the optimal system configuration, which was used in the detailed sizing as a starting point. In this part the PVsyst simulations were run, which included full scale system design considering near shadings created by factory buildings. Additionally, more complex procedure of LCOE calculation has been used here considered insurances, maintenance, time value of money and possible cost reduction due to the system size. Two system options were proposed in final results; both cover the same area of 66000 m2. The first one represents an ordinary South faced design with 1.1 MW nominal power, which was optimized for the highest performance. According to PVsyst simulations, this system should produce 1108 MWh/year with the initial investment of 835,000 € and 0.056 €/kWh LCOE. The second option has an alternative East-West orientation, which allows to cover 80% of occupied ground and consequently have 6.6 MW PV nominal power. The system produces 5388 MWh/year costs about 4500,000 € and delivers electricity with the same price of 0.056 €/kWh. Even though the EW solution has 20% lower specific energy production, it benefits mainly from lower relative costs for inverters, mounting and annual maintenance expenses. After analyzing the performance results, among the two alternatives none of the systems showed a clear superiority so there was no optimal system proposed. Both, South and East-West solutions have own advantages and disadvantages in terms of energy production profile, configuration, installation and maintenance. Furthermore, the uncertainty due to cost figures assumptions restricted the results veracity.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Hybrid Photovoltaic Thermal (PVT) collectors are an emerging technology that combines PV and solar thermal systems in a single solar collector producing heat and electricity simultaneously. The focus of this thesis work is to evaluate the performance of unglazed open loop PVT air system integrated on a garage roof in Borlänge. As it is thought to have a significant potential for preheating ventilation of the building and improving the PV modules electrical efficiency. The performance evaluation is important to optimize the cooling strategy of the collector in order to enhance its electrical efficiency and maximize the production of thermal energy. The evaluation process involves monitoring the electrical and thermal energies for a certain period of time and investigating the cooling effect on the performance through controlling the air mass flow provided by a variable speed fan connected to the collector by an air distribution duct. The distribution duct transfers the heated outlet air from the collector to inside the building. The PVT air collector consists of 34 Solibro CIGS type PV modules (115 Wp for each module) which are roof integrated and have replaced the traditional roof material. The collector is oriented toward the south-west with a tilt of 29 ᵒ. The collector consists of 17 parallel air ducts formed between the PV modules and the insulated roof surface. Each air duct has a depth of 0.05 m, length of 2.38 m and width of 2.38 m. The air ducts are connected to each other through holes. The monitoring system is based on using T-type thermocouples to measure the relevant temperatures, air sensor to measure the air mass flow. These parameters are needed to calculate the thermal energy. The monitoring system contains also voltage dividers to measure the PV modules voltage and shunt resistance to measure the PV current, and AC energy meters which are needed to calculate the produced electrical energy. All signals recorded from the thermocouples, voltage dividers and shunt resistances are connected to data loggers. The strategy of cooling in this work was based on switching the fan on, only when the difference between the air duct temperature (under the middle of top of PV column) and the room temperature becomes higher than 5 °C. This strategy was effective in term of avoiding high electrical consumption by the fan, and it is recommended for further development. The temperature difference of 5 °C is the minimum value to compensate the heat losses in the collecting duct and distribution duct. The PVT air collector has an area of (Ac=32 m2), and air mass flow of 0.002 kg/s m2. The nominal output power of the collector is 4 kWppv (34 CIGS modules with 115 Wppvfor each module). The collector produces thermal output energy of 6.88 kWth/day (0.21 kWth/m2 day) and an electrical output energy of 13.46 kWhel/day (0.42 kWhel/m2 day) with cooling case. The PVT air collector has a daily thermal energy yield of 1.72 kWhth/kWppv, and a daily PV electrical energy yield of 3.36 kWhel /kWppv. The fan energy requirement in this case was 0.18 kWh/day which is very small compared to the electrical energy generated by the PV collector. The obtained thermal efficiency was 8 % which is small compared to the results reported in literature for PVT air collectors. The small thermal efficiency was due to small operating air mass flow. Therefore, the study suggests increasing the air mass flow by a factor of 25. The electrical efficiency was fluctuating around 14 %, which is higher than the theoretical efficiency of the PV modules, and this discrepancy was due to the poor method of recording the solar irradiance in the location. Due to shading effect, it was better to use more than one pyranometer.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Esta pesquisa objetiva buscar parâmetros que permitam avaliar a eficiência relativa de uma instituição, assim considerada a administração pública direta, de forma a subsidiar as decisões do gestor atendendo ao princípio da eficiência insculpido no artigo 37, caput, da Constituição Federal, considerado o tema oportuno, haja vista a tramitação do projeto de reforma do Judiciário, reforma esta que não pode desconsiderar os princípios que regem a atuação do gestor público, entre eles o da eficiência. O objetivo central da pesquisa, então, foi a estruturação de um modelo de avaliação da eficiência relativa das Varas do Trabalho no Paraná, desdobrado em objetivos específicos. Para alcance de tais objetivos foi adotado o método de pesquisa operacional e, na busca da solução, optou-se pelo modelo matemático oferecido pela DEA – Análise Envoltória de Dados, mais as técnicas como a TGN – Técnica Grupo Nominal, combinada com a de brainstorming e o Método de Análise Hierárquica, para refinamento dos dados obtidos, num total de 14h de reunião, divididas em sete encontros, um a cada semana, com o Corregedor e ex-corregedores da Justiça do Trabalho no Paraná. Os resultados finais foram confirmados, ainda que tenham surpreendido aos profissionais da instituição onde se validou o modelo, através de entrevista semi-estruturada, ficando patente, entre outras situações, a de que o gestor público não se socorre de técnicas de gestão e, em muitas situações, em face do princípio da estrita legalidade, vê -se constrangido na ação em busca de melhor eficiência.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

O presente trabalho é uma análise experimental que procura investigar os efeitos dos fatores carga por eixo, pressão de inflação e tipo de pneu sobre o desempenho de pavimentos. Os dados e informações existentes sobre o quadro de cargas por eixo praticada pela frota de veículos pesados é razoável. A ação conjunta dos referidos fatores é ainda uma questão pouco explorada. Assim, para compensar a escassez de dados sobre pressão de inflação e tipo de construção de pneus utilizados na frota de carga, programou-se uma pesquisa de campo na rodovia estadual RS/240. As informações oriundas da pesquisa demonstram que há um acréscimo generalizado no valor da pressão dos pneus e um aumento de uso dos pneus de fabricação radial em relação aos pneus convencionais. Os dados de campo subsidiaram a programação de um experimento fatorial cruzado executado na Área de Pesquisas e Testes de Pavimentos da UFRGS/DAER. A variação dos níveis dos fatores deu-se através de um simulador linear de tráfego atuando sobre uma pista experimental com 20 m de comprimento por 3,5 m de largura. Tendo como resposta estrutural do pavimento a máxima deflexão superficial recuperável medida com uma viga Benkelmam, determinou-se como significantes os efeitos dos fatores carga por eixo e pressão de enchimento dos pneus. Os cálculos estatísticos indicam também que não há diferenças significativas entre os pneus tipo 9.00R20 e 9.00x20 e que todas interações não exercem efeitos significativos sobre a variável de resposta. Em seqüência, determinaram-se as áreas de contato do rodado duplo do simulador de tráfego com a superfície do pavimento ensaiado para as combinações dos níveis dos fatores. Pode-se, então, comparar área de contato medida com área circular calculada, considerada em muitos modelos de dimensionamento de pavimentos. Relacionou-se a variação da pressão de contato com a deflexão recuperável e procedeu-se uma comparação da mesma com a pressão de inflação nominal dos pneus. Apresenta-se um modelo de análise do desempenho do pavimento em função da carga por eixo e da pressão de inflação, nos limites do experimento. Os dados decorrentes do experimento viabilizaram a determinação dos Fatores de Equivalência de Cargas para os níveis dos fatores, considerando-se o pavimento ensaiado. Avaliou-se, via evolução das deflexões e dos Fatores de Equivalência de Cargas, a redução da vida do pavimento, obtendo-se, para a combinação de níveis mais críticos de carregamento, resultados significativos de até 88 % de redução. Propõe-se, por último, uma formulação para o Fator de Equivalência de Cargas que considere também a ação da pressão de inflação.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Este trabalho insere em seu conteúdo dois propósitos: o primeiro é o de apresentar uma microusina experimental, uma planta piloto de uma microcentral hidrelétrica automatizada, que foi montada para ser utilizada como laboratório de pesquisas do desempenho de máquinas assíncronas de até 5CV operando como geradores de energia elétrica. Para isso, apresentamos todos os equipamentos com as suas respectivas especificações, a descrição do funcionamento e documentos gerais do projeto. O segundo é fazer uma revisão do uso da máquina assíncrona, funcionando como gerador de energia elétrica ligada à rede de distribuição local. Estudamos e apresentamos algumas conclusões sobre o comportamento deste tipo de gerador, no contexto de uma microcentral hidrelétrica automatizada, em situações operacionais onde se pode contemplar máxima potência ou máximo fator de potência ou, então, máximo rendimento. Realizamos análises teóricas considerando o circuito equivalente do gerador instalado na microcentral; foram geradas curvas das grandezas envolvidas no processo de geração de energia elétrica, e estes resultados foram comparados com as medidas fornecidas pelas leituras dos instrumentos, enquanto a máquina no ambiente da microusina experimental, era submetida à situação de carga zero até a máxima. Com os resultados colhidos procuramos estabelecer uma relação entre a potência mecânica nominal de motores assíncronos com a potência ativa nominal deste tipo de máquina operando como gerador.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Nós investigamos conceito de âncora nominal de uma economia aberta analisamos comportamento dinâmico de algumas variáveis econômicas importantes tais como inflação desemprego taxa real de câmbio durante processo de desinflação. Utilizando uma versão do Modelo Mundell-Fleming onde inércia introduzida através de expectativas adaptativas nós confrontamos estabilização baseada na taxa de câmbio(âncora cambial) com àquela baseada no controle de algum agregado monetário(âncora monetária). Nós mostramos que embora âncora cambial possua um efeito inicial expansionista sobre nível de atividade econômica, oposto ocorrendo com âncora monetária, recessão necessária para derrubar inflação independe da âncora nominal adotada, concluindo que estratégia anti-inflacionária ótima depende das preferências intertemporais dos policy-makers isto é, de como eles desejam distribuir os custos da estabilização ao longo do tempo de modo maximizar bem-estar social.