815 resultados para single-frequency fiber amplifier
Resumo:
A newly introduced inverse class-E power amplifier (PA) was designed, simulated, fabricated, and characterized. The PA operated at 2.26 GHz and delivered 20.4-dBm output power with peak drain efficiency (DE) of 65% and power gain of 12 dB. Broadband performance was achieved across a 300-Mitz bandwidth with DE of better than 50% and 1-dB output-power flatness. The concept of enhanced injection predistortion with a capability to selectively suppress unwanted sub-frequency components and hence suitable for memory effects minimization is described coupled with a new technique that facilitates an accurate measurement of the phase of the third-order intermodulation (IM3) products. A robust iterative computational algorithm proposed in this paper dispenses with the need for manual tuning of amplitude and phase of the IM3 injected signals as commonly employed in the previous publications. The constructed inverse class-E PA was subjected to a nonconstant envelope 16 quadrature amplitude modulation signal and was linearized using combined lookup table (LUT) and enhanced injection technique from which superior properties from each technique can be simultaneously adopted. The proposed method resulted in 0.7% measured error vector magnitude (in rms) and 34-dB adjacent channel leakage power ratio improvement, which was 10 dB better than that achieved using the LUT predistortion alone.
Resumo:
Classical or transferase-deficient galactosaemia is an inherited metabolic disorder caused by mutation in the human Galactose-1-phosphate uridyl transferase (GALT) gene. Of some 170 causative mutations reported, fewer than 10% are observed in more than one geographic region or ethnic group. To better understand the population history of the common GALT mutations, we have established a haplotyping system for the GALT locus incorporating eight single nucleotide polymorphisms and three short tandem repeat markers. We analysed haplotypes associated with the three most frequent GALT gene mutations, Q188R, K285N and Duarte-2 (D2), and estimated their age. Haplotype diversity, in conjunction with measures of genetic diversity and of linkage disequilibrium, indicated that Q188R and K285N are European mutations. The Q188R mutation arose in central Europe within the last 20 000 years, with its observed east-west cline of increasing relative allele frequency possibly being due to population expansion during the re-colonization of Europe by Homo sapiens in the Mesolithic age. K285N was found to be a younger mutation that originated in Eastern Europe and is probably more geographically restricted as it arose after all major European population expansions. The D2 variant was found to be an ancient mutation that originated before the expansion of Homo sapiens out of Africa. Heredity (2010) 104, 148-154; doi:10.1038/hdy.2009.84; published online 29 July 2009
Resumo:
A single layer, frequency selective surface based, sub-millimeter wave transmission polarizer is presented that converts incident slant linear 45° polarization into circular polarization upon transmission. The polarization convertor consists of a 30 mm diameter 10 thick silicon reinforced metalized screen containing 2700 resonator cells and perforated with nested split ring slot apertures. The screen was designed and optimized using CST Microwave Studio and predictions were validated experimentally by transmission measurements over the 250-365 GHz frequency range. This frequency range is used for remote environmental monitoring and 325 GHz represents a molecular emission line for H2O. The results obtained show good agreement between measured and modeled predictions. The measured 3 dB axial ratio bandwidth was 11.75%, measured minimum Axial Ratio was 0.19 dB and the measured insertion loss of the single layer screen was 3.38 dB
Resumo:
We conducted a genome-wide association study testing single nucleotide polymorphisms (SNPs) and copy number variants (CNVs) for association with early-onset myocardial infarction in 2,967 cases and 3,075 controls. We carried out replication in an independent sample with an effective sample size of up to 19,492. SNPs at nine loci reached genome-wide significance: three are newly identified (21q22 near MRPS6-SLC5A3-KCNE2, 6p24 in PHACTR1 and 2q33 in WDR12) and six replicated prior observations1-4 (9p21, 1p13 near CELSR2-PSRC1-SORT1, 10q11 near CXCL12, 1q41 in MIA3, 19p13 near LDLR and 1p32 near PCSK9). We tested 554 common copy number polymorphisms (>1% allele frequency) and none met the pre-specified threshold for replication (P < 10-3). We identified 8,065 rare CNVs but did not detect a greater CNV burden in cases compared to controls, in genes compared to the genome as a whole, or at any individual locus. SNPs at nine loci were reproducibly associated with myocardial infarction, but tests of common and rare CNVs failed to identify additional associations with myocardial infarction risk.
Resumo:
A wide tuning range voltage controlled oscillator (VCO) with novel architecture is proposed in this work. The entire circuit consists of a VCO core, a summing circuit, a single-ended to differential (STD) converter and a buffer amplifier. The VCO core oscillates at half the desired frequency and the second harmonic of the VCO core is extracted by the summing circuit, which is then converted to a differential pair by the STD. The entire VCO circuit operates from 58.85 to 70.85 GHz with 20% frequency tuning range. The measured VCO gain is less than 1.6 GHz/V. The measured phase noise at 3 MHz offset is less than -78 dBc/Hz across the entire tuning range. The differential phase error of the output signals is measured by down converting the VCO output signals to low gigahertz frequency using an on-chip mixer. The measured differential phase error is less than 8°. The VCO circuit, which is constructed using 0.35 µm SiGe technology, occupies 770 × 550 µm2 die area and consumes 62 mA under 3.5 V supply.
Resumo:
Background: The utilisation of healthcare resources by prevalent haemodialysis patients has been robustly evaluated with regard to the provision of outpatient haemodialysis; however, the impact of hospitalisation among such patients is poorly defined. Minimal information is available in the UK to estimate the health and economic burden associated with the inpatient management of prevalent haemodialysis patients. The aim of this study was to assess the pattern of hospitalisation among a cohort of haemodialysis patients, before and following their initiation of haemodialysis. In addition the study sought to assess the impact of their admissions on bed occupancy in a large tertiary referral hospital in a single region in the UK.
Methods: All admission episodes were reviewed and those receiving dialysis with the Belfast City Hospital Programme were identified over a 5 year period from January 2001 to December 2005. This tertiary referral centre provides dialysis services for a population of approximately 700?000 and additional specialist renal services for the remainder of Northern Ireland. The frequency and duration of hospitalisation, and contribution to bed day occupancy of haemodialysis patients, was determined and compared to other common conditions which are known to be associated with high bed occupancy. In addition, the pattern and timing of admissions in dialysis patients in relation to their dialysis initiation date was assessed.
Results: Over the 5 year study period, 798 haemodialysis patients were admitted a total of 2882 times. These accounted for 2.5% of all admissions episodes; the median number of admissions for these patients was 3 (2–5) which compared with 1 (1–2) for non-dialysis patients. The majority of first hospitalisations (54%) were within 100 days before or after commencement of maintenance dialysis therapy. In all clinical specialties the median length of stay for haemodialysis patients was significantly longer than for patients not on haemodialysis (p=0.004). In multivariate analysis with adjustment for age, gender, and other clinically relevant diagnostic codes, maintenance haemodialysis patients stayed on average 3.75 times longer than other patient groups (ratio of geometric means 3.75, IQR 3.46–4.06).
Conclusions: Maintenance haemodialysis therapy is an important risk factor for prolonged hospitalisation regardless of the primary reason for admission. Such patients require admission more frequently than the general hospital population, particularly within 100 days before and after initiation of their first dialysis treatment.
Resumo:
Previous studies using low frequency (1 Hz) rTMS over the motor and premotor cortex have examined repetitive movements, but focused either on motor aspects of performance such as movement speed, or on variability of the produced intervals. A novel question is whether TMS affects the synchronization of repetitive movements with an external cue (sensorimotor synchronization). In the present study participants synchronized finger taps with the tones of an auditory metronome. The aim of the study was to examine whether motor and premotor cortical inhibition induced by rTMS affects timing aspects of synchronization performance such as the coupling between the tap and the tone and error correction after a metronome perturbation. Metronome sequences included perturbations corresponding to a change in the duration of a single interval (phase shifts) that were either small and below the threshold for conscious perception (10 ms) or large and perceivable (50 ms). Both premotor and motor cortex stimulation induced inhibition, as reflected in a lengthening of the silent period. Neither motor nor premotor cortex rTMS altered error correction after a phase shift. However, motor cortex stimulation made participants tap closer to the tone, yielding a decrease in tap-tone asynchrony. This provides the first neurophysiological demonstration of a dissociation between error correction and tap-tone asynchrony in sensorimotor synchronization. We discuss the results in terms of current theories of timing and error correction.
Resumo:
Neotropical orchid bees (Euglossini) are conspicuously different from other corbiculate bees (Apinae) in their lack of advanced sociality and in male use of acquired odors (fragrances) as pheromone-analogues. In both contexts, orchid bee mating systems, in particular the number of males a female mates with, are of great interest but are currently unknown. To assess female mating frequency in the genus Euglossa, we obtained nests from three species in Mexico and Panama and genotyped mothers and their brood at microsatellite DNA loci. In 26 out of 29 nests, genotypes of female brood were fully consistent with being descended from a singly mated mother. In nests with more than one adult female present, those adult females were frequently related, with genotypes being consistent with full sister-sister (r = 0.75) or mother-daughter (r = 0.5) relationships. Thus, our genetic data support the notions of female philopatry and nest-reuse in the genus Euglossa. Theoretically, single mating should promote the evolution of eusociality by maximizing the relatedness among individuals in a nest. However, in Euglossini this genetic incentive has not led to the formation of eusocial colonies as in other corbiculate bees, presumably due to differing ecological or physiological selective regimes. Finally, monandry in orchid bees is in agreement with the theory that females select a single best mate based on the male fragrance phenotype, which may contain information on male age, cognitive ability, and competitive strength.
Resumo:
A time-resolved Langmuir probe technique is used to measure the dependence of the electron density, electron temperature, plasma potential and electron energy distribution function (EEDF) on the phase of the driving voltage in a RF driven parallel plate discharge. The measurements were made in a low-frequency (100-500 kHz), symmetrically driven, radio frequency discharge operating in H-2, D-2 and Ar at gas pressures of a few hundred millitorr. The EEDFs could not be represented by a single Maxwellian distribution and resembled the time averaged EEDFs reported in 13.56 MHz discharges. The measured parameters showed structure in their spatial and temporal dependence, generally consistent with a simple oscillating sheath model. Electron temperatures of less than 0.1 eV were measured during the phase of the RF cycle when both electrodes are negative with respect to the plasma.
Resumo:
Background: A preliminary review of the UK Renal Registry (UKRR) pre-RRT study data revealed results suggesting that, for some patients, the date of start of renal replacement therapy (RRT), as reported to the UKRR, was incorrect and often significantly later than the true date of start. A more detailed study then aimed to validate a set of criteria to identify patients with an incorrect start date. Methods: Pre-RRT laboratory data were electronically extracted from 8,810 incident RRT patients from 9 UK renal centres. Any patient with a low urea (<15 mmol/L) at the start of RRT or with a substantial improvement in kidney function (either a fall in urea >10 mmol/L or rise in eGFR >2 ml/min/1.73 m) within the two months prior to RRT were considered to potentially have an incorrect date of start. In 4
selected centres, the electronic patient records of all patients flagged were reviewed to validate these criteria.
Results: Of 8,810 patients, 1,616 (18.3%) were flagged by the identification criteria as having a potentially incorrect date of start of RRT, although a single centre accounted for 41% of the total flagged cohort. Of these flagged patients, 61.7% had been assigned an incorrect date of start of haemodialysis (HD), 5.7% had evidence of acute RRT being given before the reported date of start of HD
and 9.2% had evidence of starting peritoneal dialysis exchanges prior to the reported date of start. Of
those flagged, 10.7% had a correct date of start of RRT.
Conclusions: Accurate reporting of RRT episodes is vital for the analysis of time dependent studies such as survival or time to transplantation. A proportion of patients starting RRT were assigned an incorrect start date. In order to improve the accuracy of this reporting the UK Renal Registry
must work with renal centres and clinical staff on improving data input for the start of RRT.
Comparison of frequency-selective screen-based linear to circular split-ring polarisation convertors
Resumo:
This study presents the use of periodic arrays of freestanding slot frequency-selective screens (FSS) as a means for generating circularly polarised signals from an incident linearly polarised signal at normal incidence to the structure. Measured and simulated results for crossed, linear and various ring slot element shapes in single and double-layer polarisation convertor structures are presented for 10 GHz operation. It is shown that 3 dB axial ratio (AR) bandwidths of 21% can be achieved with the one-layer perforated screen design and that the rate of change is lower than the double-layer structures. An insertion loss of 0.34 dB can be achieved for the split circular ring double-layer periodic array, and of the three topologies presented the hexagonal split-ring polarisation convertor gives the lowest variation of AR with angle of incidence 1.8 dB/45° and 3.6 dB/45° for the single and double-screen FSS, respectively. In addition, their tolerance to angle of incidence variation is presented. The capability of the surfaces reported here as twist polariser or spatial isolator components has been demonstrated with up to -30 dB isolation between incident and re-reflected signals for the double-layer designs being measured. © 2010 The Institution of Engineering and Technology.
Resumo:
Analysis and synthesis of the new Class-EF power amplifier (PA) are presented in this paper. The proposed circuit offers means to alleviate some of the major issues faced by existing Class-EF and Class-EF PAs, such as (1) substantial power losses due to parasitic resistance of the large inductor in the Class-EF load network, (2) unpredictable behaviour of practical lumped inductors and capacitors at harmonic frequencies, and (3) deviation from ideal Class-EF operation mode due to detrimental effects of device output inductance at high frequencies. The transmission-line load network of the Class-EF PA topology elaborated in this paper simultaneously satisfies the Class-EF optimum impedance requirements at fundamental frequency, second, and third harmonics as well as simultaneously providing matching to the circuit optimum load resistance for any prescribed system load resistance. Furthermore, an elegant solution using an open and short-circuit stub arrangement is suggested to overcome the problem encountered in the mm-wave IC realizations of the Class-EF PA load network due to lossy quarter-wave line. © 2010 IEICE Institute of Electronics Informati.
Resumo:
The Class-EF power amplifier (PA) introduced recently has a peak switch voltage much lower than the well-known Class-E PA. However, the value of the transistor output capacitance at high frequencies is typically larger than the required Class-EF optimum shunt capacitance. As a result, softswitching operation that minimizes power dissipation during OFF-to-ON transient cannot be achieved at high frequencies. A novel Class-EF topology with transmission-line load network proposed in this paper allows the PA to operate at much higher frequencies without trading the other figures of merit. Closed-form formulations are derived to simultaneously satisfy the Class-EF impedances requirement at fundamental frequency, all even harmonics, and the first two odd harmonics as well as to provide matching to 50O load. © 2011 Institut fur Mikrowellen.
Resumo:
The authors describe a reflection amplifier adapted to have both a reflection and a transmission port. The amplifier uses a single silicon bipolar transistor and demonstrates a reflection gain of 13 dB, transmission gain of 10 dB and 3.4 dB noise figure at 5.25 GHz. The added feature of transmission gain in the reflection amplifier permits practical implementation of full duplex microwave radiofrequency indentification (RFID) tag operation. By using a simple subcarrier modulation scheme full duplex RFID operation utilising this amplifier is demonstrated. These results indicate that for 27 dBm (0.5 W) effective isotropic radiated power (EIRP) transmit power it should be possible to obtain approximately 8 m downlink range and 25 m uplink range
Resumo:
Achieving a clearer picture of categorial distinctions in the brain is essential for our understanding of the conceptual lexicon, but much more fine-grained investigations are required in order for this evidence to contribute to lexical research. Here we present a collection of advanced data-mining techniques that allows the category of individual concepts to be decoded from single trials of EEG data. Neural activity was recorded while participants silently named images of mammals and tools, and category could be detected in single trials with an accuracy well above chance, both when considering data from single participants, and when group-training across participants. By aggregating across all trials, single concepts could be correctly assigned to their category with an accuracy of 98%. The pattern of classifications made by the algorithm confirmed that the neural patterns identified are due to conceptual category, and not any of a series of processing-related confounds. The time intervals, frequency bands and scalp locations that proved most informative for prediction permit physiological interpretation: the widespread activation shortly after appearance of the stimulus (from 100. ms) is consistent both with accounts of multi-pass processing, and distributed representations of categories. These methods provide an alternative to fMRI for fine-grained, large-scale investigations of the conceptual lexicon. © 2010 Elsevier Inc.