999 resultados para ricostruzione 3D triangolazione laser computervision
Resumo:
The Iowa Department of Transportation has been using the Bureau of Public Roads (BPR) Roughometer as part of its detour analysis process for more than 20 years. Advances in technology have made the BPR Roughometer obsolete for ride quality testing. High-speed profilers that can collect the profile of the road at highway speeds are the standard ride instruments for determining ride quality on pavements. The objective of the project was to develop a correlation between the BPR Roughometer and the high-speed laser South Dakota type Profiler (SD Profiler). Nineteen pavement sections were chosen to represent the range of types and conditions for detours. Three computer simulation models were tested on the profiler profiles. The first model is the International Ride Index (IRI) which is considered the standard index for reporting ride quality in the United States. The second model is the Ride Number (RN) developed by the University of Michigan Transportation Research Institute and the third model used is a quarter-car simulation of the BPR Roughometer (ASTM E-1170) which should match the speed and range of roadway features experienced by Iowa's BPR Roughometer Unit. The BPR Roughometer quarter-car model provided the best overall correlation with Iowa's BPR Roughometer.
Resumo:
La utilización de la tecnología láser en Odontología ha tenido una constante evolución y desarrollo. Con este trabajo se pretende hacer una actualización desde un punto de vista crítico, científico y objetivo de los avances y aplicaciones que se han publicado sobre el láser de baja potencia en el ámbito de cada una de las especialidades odontológicas. Asimismo, se exponen sus características, las normas de seguridad necesarias para su utilización, sus efectos secundarios y sus contraindicaciones.
Resumo:
El láser de diodo tiene numerosas aplicaciones en la especialidad de Cirugía Bucal siendo utilizado preferentemente para realizar intervenciones quirúrgicas sobre los tejidos blandos siempre que no impliquen un excesivo sangrado. En Endodoncia, Implantología Bucofacial y Periodoncia se emplea por su importante efecto bactericida. También se utiliza en procedimientos de blanqueamiento dentario. Es importante controlar adecuadamente el tiempo de aplicación y la potencia de trabajo para evitar el sobrecalentamiento de los tejidos vecinos, lo que produciría su necrosis. Siempre que se utilice el láser de diodo se debe efectuar la protección ocular recomendada tanto para el profesional, sus ayudantes y personal auxiliar, como para el paciente.
Resumo:
La incorporación de las nuevas tecnologías en las ciencias de la salud es, hoy en día, una realidad, ante la cual los profesionales sanitarios deben estar preparados. La tecnología láser ofrece numerosas ventajas en casi la totalidad de las especialidades odontológicas. De la amplia gama de láseres disponibles, el láser de CO2 destaca por sus aplicaciones en el ámbito de la cirugía bucal, especialmente en la cirugía de los tejidos blandos, aunque su uso también ha sido estudiado en otras disciplinas como la odontología conservadora y la endodoncia. Su uso no está exento de riesgos, y el odontólogo especializado en cirugía bucal debe poseer los conocimientos y las habilidades pertinentes para su utilización. Las características del láser de CO2 permiten una cirugía rápida y cómoda para el profesional y unas molestias postoperatorias mínimas para el paciente.
Resumo:
Plants forming a rosette during their juvenile growth phase, such as Arabidopsis thaliana (L.) Heynh., are able to adjust the size, position and orientation of their leaves. These growth responses are under the control of the plants circadian clock and follow a characteristic diurnal rhythm. For instance, increased leaf elongation and hyponasty - defined here as the increase in leaf elevation angle - can be observed when plants are shaded. Shading can either be caused by a decrease in the fluence rate of photosynthetically active radiation (direct shade) or a decrease in the fluence rate of red compared with far-red radiation (neighbour detection). In this paper we report on a phenotyping approach based on laser scanning to measure the diurnal pattern of leaf hyponasty and increase in rosette size. In short days, leaves showed constitutively increased leaf elevation angles compared with long days, but the overall diurnal pattern and the magnitude of up and downward leaf movement was independent of daylength. Shade treatment led to elevated leaf angles during the first day of application, but did not affect the magnitude of up and downward leaf movement in the following day. Using our phenotyping device, individual plants can be non-invasively monitored during several days under different light conditions. Hence, it represents a proper tool to phenotype light- and circadian clock-mediated growth responses in order to better understand the underlying regulatory genetic network.
Resumo:
One of the main problems in transmission electron microscopy in thebiological field is the tri-dimensionality. This article explains the technicalprocedures and requirements to prepare biological specimens preserving themclosest to their native state to perform 3D reconstruction of the macromolecularcomplexes and cellular structures in their natural environment.
Resumo:
A precise classification and an optimal understanding of tibial plateau fractures are the basis of a conservative treatment or adequate surgery. The aim of this prospective study is to determine the contribution of 3D CT to the classification of fractures (comparison with standard X-rays) and as an aid to the surgeon in preoperative planning and surgical reconstruction. Between November 1994 and July 1996, 20 patients presenting 22 tibial plateau fractures were considered in this study. They all underwent surgical treatment. The fractures were classified according to the Müller AO classification. They were all investigated by means of standard X-rays (AP, profile, oblique) and the 3D CT. Analysis of the results has shown the superiority of 3D CT in the planning (easier and more acute), in the classification (more precise), and in the exact assessment of the lesions (quantity of fragments); thereby proving to be of undeniable value of the surgeon.
Resumo:
Denervated muscle tissue undergoes morphologic changes that result in atrophy. The amount of muscle atrophy after denervation following free muscle transfer has not been measured so far. Therefore, the amount of muscle atrophy in human free muscle transfer for lower extremity reconstruction was measured in a series of 10 patients. Three-dimensional laser surface scanning was used to measure flap volume changes 2 weeks as well as 6 and 12 months after the operation. None of the muscles transferred was re-innervated.All muscles healed uneventfully without signs of compromised perfusion resulting in partial flap loss. The muscle volume decreased to 30 ± 4% and 19 ± 4% 6 and 12 months, respectively, after the operation, ie, the volume decreased by approximately 80% within a 12-month period.Denervated free muscle flap tissue undergoes massive atrophy of approximately 80%, mostly within the first 6 months.
Resumo:
RESUME L'Institut de Géophysique de l'Université de Lausanne a développé au cours de ces dernières années un système d'acquisition de sismique réflexion multitrace à haute résolution 2D et 3D. L'objectif de cette thèse était de poursuivre ce développement tout améliorant les connaissances de la géologie sous le lac Léman, en étudiant en particulier la configuration des grands accidents sous-lacustres dans la Molasse (Tertiaire) qui forme l'essentiel du substratum des formations quaternaires. En configuration 2D, notre système permet d'acquérir des profils sismiques avec une distance inter-CDP de 1,25 m. La couverture varie entre 6 et 18 selon le nombre de traces et la distance inter-tir. Le canon à air (15/15 eu. in.), offre une résolution verticale de 1,25 ni et une pénétration maximale de 300 m sous le fond de l'eau. Nous avons acquis au total plus de 400 km de sections 2D dans le Grand Lac et le Haut Lac entre octobre 2000 et juillet 2004. Une campagne de sismique 3D a fourni des données au large d'Evian sur une surface de 442,5 m sur 1450 m, soit 0,64 km2. La navigation ainsi que le positionnement des hydrophones et de la source ont été réalisés avec des GPS différentiels. Nous avons utilisé un traitement sismique conventionnel, sans appliquer d'AGC et en utilisant une migration post-stack. L'interprétation du substratum antéquaternaire est basée sur l'identification des sismofaciès, sur leurs relations avec les unités géologiques adjacentes au lac, ainsi que sur quelques données de forages. Nous obtenons ainsi une carte des unités géologiques dans le Grand Lac. Nous précisons la position du chevauchement subalpin entre la ville de Lausanne, sur la rive nord, et le bassin de Sciez, sur la rive sud. Dans la Molasse de Plateau, nous avons identifié les décrochements de Pontarlier et de St. Cergue ainsi que plusieurs failles non reconnues jusqu'ici. Nous avons cartographié les accidents qui affectent la Molasse subalpine ainsi que le plan de chevauchement du flysch sur la Molasse près de la rive sud du lac. Une nouvelle carte tectonique de la région lémanique a ainsi pu être dressée. L'analyse du substratum ne montre pas de failles suggérant une origine tectonique de la cuvette lémanique. Par contre, nous suggérons que la forme du creusement glaciaire, donc de la forme du lac Léman, a été influencée par la présence de failles dans le substratum antéquaternaire. L'analyse des sédiments quaternaires nous a permis de tracer des cartes des différentes interfaces ou unités qui les composent. La carte du toit du substratum antéquaternaire montre la présence de chenaux d'origine glaciaire dont la profondeur maximale atteint la cote -200 ni. Leur pente est dirigée vers le nord-est, à l'inverse du sens d'écoulement actuel des eaux. Nous expliquons cette observation par l'existence de circulations sous-glaciaires d'eau artésienne. Les sédiments glaciaires dont l'épaisseur maximale atteint 150 ni au centre du lac ont enregistré les différentes récurrences glaciaires. Dans la zone d'Evian, nous mettons en évidence la présence de lentilles de sédiments glaciolacustres perchées sur le flanc de la cuvette lémanique. Nous avons corrélé ces unités avec des données de forage et concluons qu'il s'agit du complexe inférieur de la pile sédimentaire d'Evian. Celui-ci, âgé de plus de 30 000 ans, serait un dépôt de Kame associé à un lac périglaciaire. La sismique réflexion 3D permet de préciser l'orientation de l'alimentation en matériel détritique de l'unité. La finesse des images obtenues nous permet également d'établir quels types d'érosion ont affecté certaines unités. Les sédiments lacustres, dont l'épaisseur maximale imagée atteint plus de 225 m et sans doute 400 ni sous le delta du Rhône, indiquent plusieurs mécanismes de dépôts. A la base, une mégaturbidite, épaisse d'une trentaine de mètres en moyenne, s'étend entre l'embouchure de la Dranse et le delta du Rhône. Au-dessus, la décantation des particules en suspension d'origine biologique et détritique fournit l'essentiel des sédiments. Dans la partie orientale du lac, les apports détritiques du Rhône forment un delta qui prograde vers l'ouest en s'imbriquant avec les sédiments déposés par décantation. La structure superficielle du delta a brutalement évolué, probablement à la suite de l'évènement catastrophique du Tauredunum (563 A.D.). Sa trace probable se marque par la présence d'une surface érosive que nous avons cartographiée. Le delta a ensuite changé de géométrie, avec notamment un déplacement des chenaux sous-lacustres. Sur l'ensemble de nos sections sismiques, nous n'observons aucune faille dans les sédiments quaternaires qui attesterait d'une tectonique postglaciaire du substratum. ABSTRACT During the last few years the institute of Geophysics of the University of Lausanne cleveloped a 2D and 3D high-resolution multichannel seismic reflection acquisition system. The objective of the present work was to carry on this development white improving our knowledge of the geology under Lake Geneva, in particular by studying the configuration of the large accidents affecting the Tertiary Molasse that makes up the basement of most Quaternary deposits. In its 2D configuration, our system makes it possible to acquire seismic profiles with a CDP interval of 1.25 m. The fold varies from 6 to 18 depending on the number of traces and the shooting interval. Our air gun (15/15 cu. in.) provides a vertical resolution of 1.25 m and a maximum penetration depth of approximately 300 m under water bottom. We acquired more than 400 km of 2D sections in the Grand Lac and the Haut Lac between October 2000 and July 2004. A 3D seismic survey off the city of Evian provided data on a surface of 442.5 m x 1450 m (0.64 km2). Ship's navigation as well as hydrophone- and source positioning were carried out with differential GPS. The seismic data were processed following a conventional sequence without .applying AGC and using post-stack migration. The interpretation of the pre-Quaternary substratum is based on sismofacies, on their relationships with terrestrial geological units and on some borehole data. We thus obtained a map of the geological units in the Grand Lac. We defined the location of the subalpine thrust from Lausanne, on the north shore, to the Sciez Basin, on the south shore. Within the Molasse de Plateau, we identified the already know Pontarlier and St Cergue transforms Fault as well as faults. We mapped faults that affect subalpine Molasse as well as the thrust fault plane between alpine flysch and Molasse near the lake's south shore. A new tectonic map of the Lake Geneva region could thus be drawn up. The substratum does not show faults indicating a tectonic origin for the Lake Geneva Basin. However, we suggest that the orientation of glacial erosion, and thus the shape of Lake Geneva, vas influenced by the presence of faults in the pre-Quaternary basement. The analysis of Quaternary sediments enabled us to draw up maps of various discontinuities or internal units. The top pre-Quaternary basement map shows channels of glacial origin, the deepest of them reaching an altitude of 200 m a.s.l. The channel's slopes are directed to the North-East, in opposite direction of the present water flow. We explain this observation by the presence of artesian subglacial water circulation. Glacial sediments, the maximum thickness of which reaches 150 m in the central part of the lake, record several glacial recurrences. In the Evian area, we found lenses of glacio-lacustrine sediments set high up on the flank of the Lake Geneva Bassin. We correlated these units with on-land borehole data and concluded that they represent the lower complex of the Evian sedimentary pile. The lower complex is aider than 30 000 years, and it could be a Kame deposit associated with a periglacial lake. Our 3D seismic reflexion survey enables us to specify the supply direction of detrital material in this unit. With detailed seismic images we established how some units were affected by different erosion types. The lacustrine sediments we imaged in Lake Geneva are thicker than 225 m and 400 m or more Linder the Rhone Delta. They indicate several depositional mechanisms. Their base is a major turbidite, thirty meters thick on average, that spreads between the Dranse mouth and the Rhone delta. Above this unit, settling of suspended biological and detrital particles provides most of the sediments. In the eastern part of the lake, detrital contribution from the Rhone builds a delta that progrades to the west and imbricates with the settling sediments. The shallow structure of the Rhone delta abruptly evolved, probably after the catastrophic Tauredunum event (563 A.D.). It probably coincides with an erosive surface that we mapped. As a result, the delta geometry changed, in particular associated with a displacement of water bottom channels. In all our seismic sections, we do not observe fault in the Quaternary sediments that would attest postglacial tectonic activity in the basement.
Resumo:
U-Pb dating of zircons by laser ablation inductively coupled plasma mass spectrometry (LA-ICPMS) is a widely used analytical technique in Earth Sciences. For U-Pb ages below 1 billion years (1 Ga), Pb-206/U-238 dates are usually used, showing the least bias by external parameters such as the presence of initial lead and its isotopic composition in the analysed mineral. Precision and accuracy of the Pb/U ratio are thus of highest importance in LA-ICPMS geochronology. We consider the evaluation of the statistical distribution of the sweep intensities based on goodness-of-fit tests in order to find a model probability distribution fitting the data to apply an appropriate formulation for the standard deviation. We then discuss three main methods to calculate the Pb/U intensity ratio and its uncertainty in the LA-ICPMS: (1) ratio-of-the-mean intensities method, (2) mean-of-the-intensity-ratios method and (3) intercept method. These methods apply different functions to the same raw intensity vs. time data to calculate the mean Pb/U intensity ratio. Thus, the calculated intensity ratio and its uncertainty depend on the method applied. We demonstrate that the accuracy and, conditionally, the precision of the ratio-of-the-mean intensities method are invariant to the intensity fluctuations and averaging related to the dwell time selection and off-line data transformation (averaging of several sweeps); we present a statistical approach how to calculate the uncertainty of this method for transient signals. We also show that the accuracy of methods (2) and (3) is influenced by the intensity fluctuations and averaging, and the extent of this influence can amount to tens of percentage points; we show that the uncertainty of these methods also depends on how the signal is averaged. Each of the above methods imposes requirements to the instrumentation. The ratio-of-the-mean intensities method is sufficiently accurate provided the laser induced fractionation between the beginning and the end of the signal is kept low and linear. We show, based on a comprehensive series of analyses with different ablation pit sizes, energy densities and repetition rates for a 193 nm ns-ablation system that such a fractionation behaviour requires using a low ablation speed (low energy density and low repetition rate). Overall, we conclude that the ratio-of-the-mean intensities method combined with low sampling rates is the most mathematically accurate among the existing data treatment methods for U-Pb zircon dating by sensitive sector field ICPMS.
Resumo:
This study aimed to use the plantar pressure insole for estimating the three-dimensional ground reaction force (GRF) as well as the frictional torque (T(F)) during walking. Eleven subjects, six healthy and five patients with ankle disease participated in the study while wearing pressure insoles during several walking trials on a force-plate. The plantar pressure distribution was analyzed and 10 principal components of 24 regional pressure values with the stance time percentage (STP) were considered for GRF and T(F) estimation. Both linear and non-linear approximators were used for estimating the GRF and T(F) based on two learning strategies using intra-subject and inter-subjects data. The RMS error and the correlation coefficient between the approximators and the actual patterns obtained from force-plate were calculated. Our results showed better performance for non-linear approximation especially when the STP was considered as input. The least errors were observed for vertical force (4%) and anterior-posterior force (7.3%), while the medial-lateral force (11.3%) and frictional torque (14.7%) had higher errors. The result obtained for the patients showed higher error; nevertheless, when the data of the same patient were used for learning, the results were improved and in general slight differences with healthy subjects were observed. In conclusion, this study showed that ambulatory pressure insole with data normalization, an optimal choice of inputs and a well-trained nonlinear mapping function can estimate efficiently the three-dimensional ground reaction force and frictional torque in consecutive gait cycle without requiring a force-plate.
Resumo:
Expression of water soluble proteins of fresh pork Longissimus thoracis from 4 pure breed pigs (Duroc, Large White, Landrace, and Piétrain) was studied to identify candidate protein markers for meat quality. Surface-enhanced laser desorption/ionisation time-of-flight mass spectrometry (SELDI-TOF-MS) was used to obtain the soluble protein profiles of Longissimus thoracis muscles. The pure breeds showed differences among the studied meat quality traits (pHu, drip loss, androstenone, marbling, intramuscular fat, texture, and moisture), but no significant differences were detected in sensory analysis. Associations between protein peaks obtained with SELDI-TOF-MS and meat quality traits, mainly water holding capacity, texture and skatole were observed. Of these peaks, a total of 10 peaks from CM10 array and 6 peaks from Q10 array were candidate soluble protein markers for pork loin quality. The developed models explained a limited proportion of the variability, however they point out interesting relationships between protein expression and meat quality
3D coronary vessel wall imaging utilizing a local inversion technique with spiral image acquisition.
Resumo:
Current 2D black blood coronary vessel wall imaging suffers from a relatively limited coverage of the coronary artery tree. Hence, a 3D approach facilitating more extensive coverage would be desirable. The straightforward combination of a 3D-acquisition technique together with a dual inversion prepulse can decrease the effectiveness of the black blood preparation. To minimize artifacts from insufficiently suppressed blood signal of the nearby blood pools, and to reduce residual respiratory motion artifacts from the chest wall, a novel local inversion technique was implemented. The combination of a nonselective inversion prepulse with a 2D selective local inversion prepulse allowed for suppression of unwanted signal outside a user-defined region of interest. Among 10 subjects evaluated using a 3D-spiral readout, the local inversion pulse effectively suppressed signal from ventricular blood, myocardium, and chest wall tissue in all cases. The coronary vessel wall could be visualized within the entire imaging volume.