923 resultados para research evaluation


Relevância:

30.00% 30.00%

Publicador:

Resumo:

The aim of this work was to compare the performance of isotope-selective non-dispersive infrared spectrometry (IRIS) for the 13C-urea breath test with the combination of the 14C-urea breath test (14C-UBT), urease test and histologic examination for the diagnosis of H. pylori (HP) infection. Fifty-three duodenal ulcer patients were studied. All patients were submitted to gastroscopy to detect HP by the urease test, histologic examination and 14C-UBT. To be included in the study the results of the 3 tests had to be concordant. Within one month after admission to the study the patients were submitted to IRIS with breath samples collected before and 30 min after the ingestion of 75 mg 13C-urea dissolved in 200 ml of orange juice. The samples were mailed and analyzed 11.5 (4-21) days after collection. Data were analyzed statistically by the chi-square and Mann-Whitney test and by the Spearman correlation coefficient. Twenty-six patients were HP positive and 27 negative. There was 100% agreement between the IRIS results and the HP status determined by the other three methods. Using a cutoff value of delta-over-baseline (DOB) above 4.0 the IRIS showed a mean value of 19.38 (minimum = 4.2, maximum = 41.3, SD = 10.9) for HP-positive patients and a mean value of 0.88 (minimum = 0.10, maximum = 2.5, SD = 0.71) for negative patients. Using a cutoff value corresponding to 0.800% CO2/weight (kg), the 14C-UBT showed a mean value of 2.78 (minimum = 0.89, maximum = 5.22, SD = 1.18) in HP-positive patients. HP-negative patients showed a mean value of 0.37 (minimum = 0.13, maximum = 0.77, SD = 0.17). IRIS is a low-cost, easy to manage, highly sensitive and specific test for H. pylori detection. Storing and mailing the samples did not interfere with the performance of the test.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The aim of this study was to analyze the thickness of the intima-media complex (IMC) using a noninvasive method. The carotid and femoral common arteries were evaluated by noninvasive B-mode ultrasound in 63 normotensive and in 52 hypertensive subjects and the thickness of the IMC was tested for correlation with blood pressure, cardiac structures and several clinical and biological parameters. The IMC was thicker in hypertensive than in normotensive subjects (0.67 ± 0.13 and 0.62 ± 0.16 vs 0.54 ± 0.09 and 0.52 ± 0.11 mm, respectively, P<0.0001). In normotensive patients, the simple linear regression showed significant correlations between IMC and age, body mass index and 24-h systolic blood pressure for both the carotid and femoral arteries. In hypertensives the carotid IMC was correlated with age and 24-h systolic blood pressure while femoral IMC was correlated only with 24-h diastolic blood pressure. Forward stepwise regression showed that age, body mass index and 24-h systolic blood pressure influenced the carotid IMC relationship (r2 = 0.39) in normotensives. On the other hand, the femoral IMC relationship was influenced by 24-h systolic blood pressure and age (r2 = 0.40). In hypertensives, age and 24-h systolic blood pressure were the most important determinants of carotid IMC (r2 = 0.37), while femoral IMC was influenced only by 24-h diastolic blood pressure (r2 = 0.10). There was an association between carotid IMC and echocardiographic findings in normotensives, while in hypertensives only the left posterior wall and interventricular septum were associated with femoral IMC. We conclude that age and blood pressure influence the intima-media thickness, while echocardiographic changes are associated with the IMC.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

We evaluated the mechanical behavior of the repaired surfaces of defective articular cartilage in the intercondylar region of the rat femur after a hydrogel graft implant. The results were compared to those for the adjacent normal articular cartilage and for control surfaces where the defects remained empty. Hydrogel synthesized by blending poly(2-hydroxyethyl methacrylate) and poly(methyl methacrylate-co-acrylic acid) was implanted in male Wistar rats. The animals were divided into five groups with postoperative follow-up periods of 3, 5, 8, 12 and 16 weeks. Indentation tests were performed on the neoformed surfaces in the knee joint (with or without a hydrogel implant) and on adjacent articular cartilage in order to assess the mechanical properties of the newly formed surface. Kruskal-Wallis analysis indicated that the mechanical behavior of the neoformed surfaces was significantly different from that of normal cartilage. Histological analysis of the repaired defects showed that the hydrogel implant filled the defect with no signs of inflammation as it was well anchored to the surrounding tissues, resulting in a newly formed articular surface. In the case of empty control defects, osseous tissue grew inside the defects and fibrous tissue formed on the articular surface of the defects. The repaired surface of the hydrogel implant was more compliant than normal articular cartilage throughout the 16 weeks following the operation, whereas the fibrous tissue that formed postoperatively over the empty defect was stiffer than normal articular cartilage after 5 weeks. This stiffness started to decrease 16 weeks after the operation, probably due to tissue degeneration. Thus, from the biomechanical and histological point of view, the hydrogel implant improved the articular surface repair.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A pulsatile pressure-flow model was developed for in vitro quantitative color Doppler flow mapping studies of valvular regurgitation. The flow through the system was generated by a piston which was driven by stepper motors controlled by a computer. The piston was connected to acrylic chambers designed to simulate "ventricular" and "atrial" heart chambers. Inside the "ventricular" chamber, a prosthetic heart valve was placed at the inflow connection with the "atrial" chamber while another prosthetic valve was positioned at the outflow connection with flexible tubes, elastic balloons and a reservoir arranged to mimic the peripheral circulation. The flow model was filled with a 0.25% corn starch/water suspension to improve Doppler imaging. A continuous flow pump transferred the liquid from the peripheral reservoir to another one connected to the "atrial" chamber. The dimensions of the flow model were designed to permit adequate imaging by Doppler echocardiography. Acoustic windows allowed placement of transducers distal and perpendicular to the valves, so that the ultrasound beam could be positioned parallel to the valvular flow. Strain-gauge and electromagnetic transducers were used for measurements of pressure and flow in different segments of the system. The flow model was also designed to fit different sizes and types of prosthetic valves. This pulsatile flow model was able to generate pressure and flow in the physiological human range, with independent adjustment of pulse duration and rate as well as of stroke volume. This model mimics flow profiles observed in patients with regurgitant prosthetic valves.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Genetic damage caused by ionizing radiation and repair capacity of blood lymphocytes from 3 breast cancer patients and 3 healthy donors were investigated using the comet assay. The comets were analyzed by two parameters: comet tail length and visual classification. Blood samples from the donors were irradiated in vitro with a 60Co source at a dose rate of 0.722 Gy/min, with a dose range of 0.2 to 4.0 Gy and analyzed immediately after the procedure and 3 and 24 h later. The basal level of damage and the radioinduced damage were higher in lymphocytes from breast cancer patients than in lymphocytes from healthy donors. The radioinduced damage showed that the two groups had a similar response when analyzed immediately after the irradiations. Therefore, while the healthy donors presented a considerable reduction of damage after 3 h, the patients had a higher residual damage even 24 h after exposure. The repair capacity of blood lymphocytes from the patients was slower than that of lymphocytes from healthy donors. The possible influence of age, disease stage and mutations in the BRCA1 and BRCA2 genes are discussed. Both parameters adopted proved to be sensitive and reproducible: the dose-response curves for DNA migration can be used not only for the analysis of cellular response but also for monitoring therapeutic interventions. Lymphocytes from the breast cancer patients presented an initial radiosensitivity similar to that of healthy subjects but a deficient repair mechanism made them more vulnerable to the genotoxic action of ionizing radiation. However, since lymphocytes from only 3 patients and 3 normal subjects were analyzed in the present paper, additional donors will be necessary for a more accurate evaluation.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Forty-seven patients with unilateral obstructive calculi (12 males and 35 females) were submitted to 99mTc-diethylene triamine pentaacetic acid (DTPA) or 99mTc-dimercaptosuccinic acid (DMSA) scans for assessment of renal function. The scans revealed unilateral functional deficit in 68 and 66% of the patients, respectively. A calculus size of 1.1 to 2.0 cm was significantly associated with deficit detected by DTPA, but duration of obstruction and calculus localization were not. After relief of the obstruction, the mean percent renal function of the affected kidney was found to be significantly increased from 25 ± 12% to 29 ± 12% in DTPA and from 21 ± 15% to 24 ± 12% in DMSA. Initial Doppler ultrasonography performed in 35 patients detected an increased resistive index in 10 (29%). In the remaining patients with a normal resistive index, ureteral urinary jet was observed, indicating partial obstruction. The high frequency of renal function impairment detected by DTPA and of tubulointerstitial damage detected by DMSA as well as the slight amelioration of unilateral renal function after relief of obstruction suggest that scintigraphy assessment may help evaluate the unilateral percentage of renal function and monitor renal function recovery when it occurs. The presence of a urinary jet detected by Doppler ultrasonography further indicates the severity of obstruction and the recovery prognosis.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Non-absorbable microgranular hydroxyapatite was infiltrated into the subepidermal abdominal region of guinea pigs in order to assess the possibility of using this material to correct deficiencies in orbital volume. Microgranular hydroxyapatite (2.0 ml) was subepidermally infiltrated into the abdominal region of 20 guinea pigs. The animals were divided into four experimental groups of 5 animals each, which were killed 7 (G1), 15 (G2), 30 (G3) and 60 (G4) days after infiltration. The area and the largest and smallest diameters of the nodules formed by infiltration were evaluated at the site of infiltration and histological examination was performed. The mean granuloma area was similar in all groups. Histopathological examination showed that the material remained isolated from surrounding tissues by a pseudocapsule that became denser throughout the experiment. A host reaction started with young fibroblastic tissue that evolved to dense tissue until cartilaginous tissue was formed in G4, progressively advancing towards the center of the granuloma from G1 to G4. Non-absorbable microgranular hydroxyapatite is an inert material that was well tolerated by the animals studied, with maintenance of the infiltrated volume, and may perhaps be useful to fill anophthalmic cavities.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Trimethylsulfonium, a compound present in the midgut gland of the sea hare Aplysia brasiliana, negatively modulates vagal response, indicating a probable ability to inhibit cholinergic responses. In the present study, the pharmacological profile of trimethylsulfonium was characterized on muscarinic and nicotinic acetylcholine receptors. In rat jejunum the contractile response induced by trimethylsulfonium (pD2 = 2.46 ± 0.12 and maximal response = 2.14 ± 0.32 g) was not antagonized competitively by atropine. The maximal response (Emax) to trimethylsulfonium was diminished in the presence of increasing doses of atropine (P<0.05), suggesting that trimethylsulfonium-induced contraction was not related to muscarinic stimulation, but might be caused by acetylcholine release due to presynaptic stimulation. Trimethylsulfonium displaced [³H]-quinuclidinyl benzilate from rat cortex membranes with a low affinity (Ki = 0.5 mM). Furthermore, it caused contraction of frog rectus abdominis muscles (pD2 = 2.70 ± 0.06 and Emax = 4.16 ± 0.9 g), which was competitively antagonized by d-tubocurarine (1, 3 or 10 µM) with a pA2 of 5.79, suggesting a positive interaction with nicotinic receptors. In fact, trimethylsulfonium displaced [³H]-nicotine from rat diaphragm muscle membranes with a Ki of 27.1 µM. These results suggest that trimethylsulfonium acts as an agonist on nicotinic receptors, and thus contracts frog skeletal rectus abdominis muscle and rat jejunum smooth muscle via stimulation of postjunctional and neuronal prejunctional nicotinic cholinoreceptors, respectively.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The Horne-Östberg questionnaire partly covers some factors that may be important determinants of peak time and characterize patterns of behavior. We conducted a study for the evaluation of self-reported behavioral states (hunger sensation, availability for study, physical exercise, solving daily problems, and time preferences) as expressions of underlying cyclic activity. Three hundred and eighteen community subjects without history of medical, psychiatric, or sleep disorders were evaluated in a cross-sectional design. A self-report about daily highest level of activity was used to categorize individuals into morning, evening, and indifferently active. Time-related behavioral states were evaluated with 23 visual analog questions. The responses to most analogic questions were significantly different between morning and evening active subjects. Logistic regression analysis identified a group of behaviors more strongly associated with the self-reported activity pattern (common wake up time, highest subjective fatigue, as well as wake up, bedtime, exercise and study preferences). These findings suggested that the patterns of activity presented by normal adults were related to specific common behavioral characteristics that may contribute to peak time.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The Christo Inventory for Substance-Misuse Services (CISS) is a single page outcome evaluation tool completed by drug alcohol service workers either on the basis of direct client interviews or of personal experience of their client supplemented by existing assessment notes. It was developed to assist substance misuse services to empirically demonstrate the effectiveness of their treatments to their respective funding bodies. Its 0 to 20 unidimensional scale consists of 10 items reflecting clients' problems with social functioning, general health, sexual/injecting risk behavior, psychological functioning, occupation, criminal involvement, drug/alcohol use, ongoing support, compliance, and working relationships. Good reliability and validity has already been demonstrated for the CISS [Christo et al., Drug and Alcohol Dependence 2000; 59: 189-197] but the original was written in English and a Portuguese version is presented here. The present review explores its applicability to a Brazilian setting, summarizes its characteristics and uses, and describes the process of translation to Portuguese. A pilot study conducted in a substance misuse service for adolescents indicated it is likely to be suitable for use among a Brazilian population. The simplicity, flexibility and brevity of the CISS make it a useful tool allowing comparison of clients within and between many different service settings.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Neutralization of hyperalgesia induced by Bothrops jararaca and B. asper venoms was studied in rats using bothropic antivenom produced at Instituto Butantan (AVIB, 1 ml neutralizes 5 mg B. jararaca venom) and polyvalent antivenom produced at Instituto Clodomiro Picado (AVCP, 1 ml neutralizes 2.5 mg B. aspar venom). The intraplantar injection of B. jararaca and B. asper venoms caused hyperalgesia, which peaked 1 and 2 h after injection, respectively. Both venoms also induced edema with a similar time course. When neutralization assays involving the independent injection of venom and antivenom were performed, the hyperalgesia induced by B. jararaca venom was neutralized only when bothropic antivenom was administered iv 15 min before venom injection, whereas edema was neutralized when antivenom was injected 15 min or immediately before venom injection. On the other hand, polyvalent antivenom did not interfere with hyperalgesia or edema induced by B. asper venom, even when administered prior to envenomation. The lack of neutralization of hyperalgesia and edema induced by B. asper venom is not attributable to the absence of neutralizing antibodies in the antivenom, since neutralization was achieved in assays involving preincubation of venom and antivenom. Cross-neutralization of AVCP or AVIB against B. jararaca and B. asper venoms, respectively, was also evaluated. Only bothropic antivenom partially neutralized hyperalgesia induced by B. asper venom in preincubation experiments. The present data suggest that hyperalgesia and edema induced by Bothrops venoms are poorly neutralized by commercial antivenoms even when antibodies are administered immediately after envenomation.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The species Cordia curassavica (Boraginaceae), known popularly as "erva baleeira", is used in folk medicine for the treatment of several inflammatory processes and as a healing agent. The objective of the present study was to evaluate the antiedematogenic activity of crude dichloromethane extracts of Cordia curassavica and of the artemetin-enriched fraction. The crude extract and artemetin fraction were tested in the model of carrageenin-induced paw edema in male Swiss mice (25-30 g). The crude dichloromethane extract (300 and 1000 mg/kg, po, N = 6) showed significant antiedematogenic activity, reducing the edema by 42, 57 and 45% and 46, 62 and 69%, 3, 4 and 5 h after carrageenin administration, respectively. Indomethacin (10 mg/kg, po, N = 6) reduced the edema by 45 and 48%, after 4 and 5 h, but the artemetin-enriched fraction (30, 100 and 300 mg/kg, po, N = 6) had no activity. The dichloromethane extract (300 and 1000 mg/kg, po, N = 6) also showed antinociceptive activity by reducing acetic acid-induced writhing in mice from 37.1 ± 2.28 (control) to 17.3 ± 1.34 and 13.2 ± 1.44, respectively, but had no activity in the hot-plate test.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Two radioaerosol preparations, TechneScan®-DTPA (99mTc-DTPA, 40 mCi/3 ml; IPEN-CNEN, São Paulo, SP, Brazil) and TechneScan®-DTPA/AEROSOL (99mTc-DTPA/A, 15 mCi/1.5 ml with 0.5 ml ethanol; Mallinckrodt Medical, St. Louis, MO, USA), were compared in pulmonary ventilation studies in terms of total radiocounts and clearance after inhalation. An aerosol with ethanol is supposed to better distribute the radioparticles in the lungs. Twenty normal nonsmoking volunteers (10 men and 10 women), mean age of 23.2 years (range: 20 to 35 years), were studied. Images were obtained immediately and 30, 60 and 90 min after inhalation. Total and regional counts were obtained and the clearance half-lives of both lungs were determined. There was no difference in total counts between the two types of radioaerosol at any time (mean of ~188,000 cpm for male and female subjects at time zero in both aerosols). The highest count was obtained in the middle region of both lungs (P<0.001) with both preparations. The clearance half-life did not differ between aerosols (mean of ~80-88 min for male and female subjects for both aerosols). Small nonsignificant regional differences were observed. No differences between genders or between right and left lung were observed. 99mTc-DTPA/A generated the highest output of radioaerosol. 99mTc-DTPA with alcohol costs approximately five times more than the aerosol without alcohol. The present results show that either kind of aerosol may be adopted routinely for use in pulmonary examinations without affecting diagnosis. We suggest that the amount of 740 mBq (20 mCi) of 99mTc-DTPA in 1.5 ml saline can be used for routine examinations resulting in reduction of costs in pulmonary ventilation studies without diagnostic impairment.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Differentiation between stunned and infarcted myocardium in the setting of acute ischemia is challenging. Real time myocardial contrast echocardiography allows the simultaneous assessment of myocardial perfusion and function. In the present study we evaluated infarcted and stunned myocardium in an experimental model using real time myocardial contrast echocardiography. Sixteen dogs underwent 180 min of coronary occlusion followed by reperfusion (infarct model) and seven other dogs were submitted to 20 min of coronary occlusion followed by reperfusion (stunned model). Wall motion abnormality and perfusional myocardial defect areas were measured by planimetry. Risk and infarct areas were determined by tissue staining. In the infarct model, the wall motion abnormality area during coronary occlusion (5.52 ± 1.14 cm²) was larger than the perfusional myocardial defect area (3.71 ± 1.45 cm²; P < 0.001). Reperfusion resulted in maintenance of wall motion abnormality (5.45 ± 1.41 cm²; P = 0.43 versus occlusion) and reduction of perfusional myocardial defect (1.51 ± 1.29 cm²; P = 0.004 versus occlusion). Infarct size determined by contrast echocardiography correlated with tissue staining (r = 0.71; P = 0.002). In the stunned model, the wall motion abnormality area was 5.49 ± 0.68 cm² during occlusion and remained 5.1 ± 0.63 cm² after reperfusion (P = 0.07). Perfusional defect area was 2.43 ± 0.79 cm² during occlusion and was reduced to 0.2 ± 0.53 cm² after reperfusion (P = 0.04). 2,3,5-Triphenyl tetrazolium chloride staining confirmed the absence of necrotic myocardium in all dogs in the stunned model. Real time myocardial contrast echocardiography is a noninvasive technique capable of distinguishing between stunned and infarcted myocardium after acute ischemia.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The potencies of mammalian cell-derived recombinant human erythropoietin pharmaceutical preparations, from a total of five manufacturers, were assessed by in vivo bioassay using standardized protocols. Eight-week-old normocythemic mice received a single subcutaneous injection followed by blood sampling 96 h later or multiple daily injections with blood sampling 24 h after the last injection. Reticulocyte counting by microscopic examination was employed as the end-point using the brilliant cresyl blue or selective hemolysis methods, together with automated flow cytometry. Different injection schedules were investigated and dose-response curves for the European Pharmacopoeia Biological Reference Preparation of erythropoietin were compared. Manual and automated methods of reticulocyte counting were correlated with respect to assay validity and precision. Using 8 mice per treatment group, intra-assay precision determined for all of the assays in the study showed coefficients of variation of 12.1-28.4% for the brilliant cresyl blue method, 14.1-30.8% for the selective hemolysis method and 8.5-19.7% for the flow cytometry method. Applying the single injection protocol, a combination of at least two independent assays was required to achieve the precision potency and confidence limits indicated by the manufacturers, while the multiple daily injection protocol yielded the same acceptable results within a single assay. Although the latter protocol using flow cytometry for reticulocyte counting gave more precise and reproducible results (intra-assay coefficients of variation: 5.9-14.2%), the well-characterized manual methods provide equally valid alternatives for the quality control of recombinant human erythropoietin therapeutic products.