741 resultados para piezoelectric


Relevância:

10.00% 10.00%

Publicador:

Resumo:

The heart is a non-regenerating organ that gradually suffers a loss of cardiac cells and functionality. Given the scarcity of organ donors and complications in existing medical implantation solutions, it is desired to engineer a three-dimensional architecture to successfully control the cardiac cells in vitro and yield true myocardial structures similar to native heart. This thesis investigates the synthesis of a biocompatible gelatin methacrylate hydrogel to promote growth of cardiac cells using biotechnology methodology: surface acoustic waves, to create cell sheets. Firstly, the synthesis of a photo-crosslinkable gelatin methacrylate (GelMA) hydrogel was investigated with different degree of methacrylation concentration. The porous matrix of the hydrogel should be biocompatible, allow cell-cell interaction and promote cell adhesion for growth through the porous network of matrix. The rheological properties, such as polymer concentration, ultraviolet exposure time, viscosity, elasticity and swelling characteristics of the hydrogel were investigated. In tissue engineering hydrogels have been used for embedding cells to mimic native microenvironments while controlling the mechanical properties. Gelatin methacrylate hydrogels have the advantage of allowing such control of mechanical properties in addition to easy compatibility with Lab-on-a-chip methodologies. Secondly in this thesis, standing surface acoustic waves were used to control the degree of movement of cells in the hydrogel and produce three-dimensional engineered scaffolds to investigate in-vitro studies of cardiac muscle electrophysiology and cardiac tissue engineering therapies for myocardial infarction. The acoustic waves were characterized on a piezoelectric substrate, lithium niobate that was micro-fabricated with slanted-finger interdigitated transducers for to generate waves at multiple wavelengths. This characterization successfully created three-dimensional micro-patterning of cells in the constructs through means of one- and two-dimensional non-invasive forces. The micro-patterning was controlled by tuning different input frequencies that allowed manipulation of the cells spatially without any pre- treatment of cells, hydrogel or substrate. This resulted in a synchronous heartbeat being produced in the hydrogel construct. To complement these mechanical forces, work in dielectrophoresis was conducted centred on a method to pattern micro-particles. Although manipulation of particles were shown, difficulties were encountered concerning the close proximity of particles and hydrogel to the microfabricated electrode arrays, dependence on conductivity of hydrogel and difficult manoeuvrability of scaffold from the surface of electrodes precluded measurements on cardiac cells. In addition, COMSOL Multiphysics software was used to investigate the mechanical and electrical forces theoretically acting on the cells. Thirdly, in this thesis the cardiac electrophysiology was investigated using immunostaining techniques to visualize the growth of sarcomeres and gap junctions that promote cell-cell interaction and excitation-contraction of heart muscles. The physiological response of beating of co-cultured cardiomyocytes and cardiac fibroblasts was observed in a synchronous and simultaneous manner closely mimicking the native cardiac impulses. Further investigations were carried out by mechanically stimulating the cells in the three-dimensional hydrogel using standing surface acoustic waves and comparing with traditional two-dimensional flat surface coated with fibronectin. The electrophysiological responses of the cells under the effect of the mechanical stimulations yielded a higher magnitude of contractility, action potential and calcium transient.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this work is to simulate and optically characterize the piezoelectric performance of complementary metal oxide semiconductor (CMOS) compatible microcantilevers based on aluminium nitride (AlN) and manufactured at room temperature. This study should facilitate the integration of piezoelectric micro-electro-mechanical systems (MEMS) such as microcantilevers, in CMOS technology. Besides compatibility with standard integrated circuit manufacturing procedures, low temperature processing also translates into higher throughput and, as a consequence, lower manufacturing costs. Thus, the use of the piezoelectric properties of AlN manufactured by reactive sputtering at room temperature is an important step towards the integration of this type of devices within future CMOS technology standards. To assess the reliability of our fabrication process, we have manufactured arrays of free-standing microcantilever beams of variable dimension and studied their piezoelectric performance. The characterization of the first out-of-plane modes of AlN-actuated piezoelectric microcantilevers has been carried out using two optical techniques: laser Doppler vibrometry (LDV) and white light interferometry (WLI). In order to actuate the cantilevers, a periodic chirp signal in certain frequency ranges was applied between the device electrodes. The nature of the different vibration modes detected has been studied and compared with that obtained by a finite element model based simulation (COMSOL Multiphysics), showing flexural as well as torsional modes. The correspondence between theoretical and experimental data is reasonably good, probing the viability of this high throughput and CMOS compatible fabrication process. To complete the study, X-ray diffraction as well as d33 piezoelectric coefficient measurements were also carried out.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Considerable interest has been devoted to converting mechanical energy into electricity using polymer nanofibres. In particular, piezoelectric nanofibres produced by electrospinning have shown remarkable mechanical energy-to-electricity conversion ability. However, there is little data for the acoustic-to-electric conversion of electrospun nanofibres. Here we show that electrospun piezoelectric nanofibre webs have a strong acoustic-to-electric conversion ability. Using poly(vinylidene fluoride) as a model polymer and a sensor device that transfers sound directly to the nanofibre layer, we show that the sensor devices can detect low-frequency sound with a sensitivity as high as 266 mV Pa(-1). They can precisely distinguish sound waves in low to middle frequency region. These features make them especially suitable for noise detection. Our nanofibre device has more than five times higher sensitivity than a commercial piezoelectric poly(vinylidene fluoride) film device. Electrospun piezoelectric nanofibres may be useful for developing high-performance acoustic sensors.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The main objective of blasting is to produce optimum fragmentation for downstream processing. Fragmentation is usually considered optimum when the average fragment size is minimum and the fragmentation distribution as uniform as possible. One of the parameters affecting blasting fragmentation is believed to be time delay between holes of the same row. Although one can find a significant number of studies in the literature, which examine the relationship between time delay and fragmentation, their results have been often controversial. The purpose of this work is to increase the level of understanding of how time delay between holes of the same row affects fragmentation. Two series of experiments were conducted for this purpose. The first series involved tests on small scale grout and granite blocks to determine the moment of burden detachment. The instrumentation used for these experiments consisted mainly of strain gauges and piezoelectric sensors. Some experiments were also recorded with a high speed camera. It was concluded that the time of detachment for this specific setup is between 300 and 600 μs. The second series of experiments involved blasting of a 2 meter high granite bench and its purpose was the determination of the hole-to-hole delay that provides optimum fragmentation. The fragmentation results were assessed with image analysis software. Moreover, vibration was measured close to the blast and the experiments were recorded with high speed cameras. The results suggest that fragmentation was optimum when delays between 4 and 6 ms were used for this specific setup. Also, it was found that the moment at which gases first appear to be venting from the face was consistently around 6 ms after detonation.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper reports on a low frequency piezoelectric energy harvester that scavenges energy from a wire carrying an AC current. The harvester is described, fabricated and characterized. The device consists of a silicon cantilever with integrated piezoelectric capacitor and proof-mass that incorporates a permanent magnet. When brought close to an AC current carrying wire, the magnet couples to the AC magnetic field from a wire, causing the cantilever to vibrate and generate power. The measured average power dissipated across an optimal resistive load was 1.5 μW. This was obtained by exciting the device into mechanical resonance using the electro-magnetic field from the 2 A source current. The measurements also reveal that the device has a nonlinear response that is due to a spring hardening mechanism.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A presente Tese de Mestrado em Medicina Dentária tem como tema a Piezocirurgia e, sobre ela, pretende-se saber a sua aplicabilidade no consultório do Médico Dentista, nomeadamente na área da Cirurgia oral. A pesquisa bibliográfica foi realizada através de bases de dados, como a Medline, Science Direct e a Pub-Med, entre outras. Limitou-se a pesquisa, temporalmente, entre 2000 e 2016, e nas línguas Portuguesa e Inglesa. Excluiu-se todas as referências a estudos animais e, todas as que, em nada, contribuiríam para o conteúdo especificado. A cirurgia Piezoeléctrica é uma técnica de osteotomia atraumática, quando comparada a técnicas convencionais, e que revoluciona a área da Cirurgia Oral, através do seu corte preciso e altamente selectivo, mas também através do fenómeno de cavitação que a caracteriza, e que garante um campo operatório livre, uma óptima visibilidade, e, consequentemente, uma maior segurança do operador, culminando tudo isto no sucesso do tratamento. A sua maior desvantagem é o tempo de trabalho que requere, contudo este tende a diminuir, e a ser ainda menor que o tempo de trabalho exigido na cirurgia convencional. Inúmeras são as aplicações da Piezocirurgia, mas na área da Medicina Dentária, nomeadamente na Cirurgia Oral, destaca-se o levantamento do seio maxilar, o aumento da crista óssea, a extracção dos terceiros molares impactados e a cirurgia ortognática.