Resumo:
We show how polarization measurements on the output fields generated by parametric down conversion will reveal a violation of multiparticle Bell inequalities, in the regime of both low- and high-output intensity. In this case, each spatially separated system, upon which a measurement is performed, is comprised of more than one particle. In view of the formal analogy with spin systems, the proposal provides an opportunity to test the predictions of quantum mechanics for spatially separated higher spin states. Here the quantum behavior possible even where measurements are performed on systems of large quantum (particle) number may be demonstrated. Our proposal applies to both vacuum-state signal and idler inputs, and also to the quantum-injected parametric amplifier as studied by De Martini The effect of detector inefficiencies is included, and weaker Bell-Clauser-Horne inequalities are derived to enable realistic tests of local hidden variables with auxiliary assumptions for the multiparticle situation.
Resumo:
Four emerging high-energy non-thermal technologies may replace or augment heating for producing sterile low-acid food products. High pressure, high-voltage pulsed electric field, high-energy ultrasound and high-intensity pulsed light are all capable of reducing bacterial spore counts under certain conditions. However, only non-continuous high pressure treatments, at temperatures higher than ambient, are currently capable of completely inactivating spores and producing sterile food products. The first three technologies also reduce the resistance of spores to inactivation by heat.
Resumo:
Onicomicose é a doença ungueal mais frequente, com prevalência estimada entre 2 e 8% da população. As estratégias de tratamentos atuais incluem uso de antifúngicos tópicos e orais, ambos geralmente com baixos índices de cura. Os objetivos deste estudo foram avaliar a resposta terapêutica ao laser Nd:YAG 1.064 nm no tratamento da onicomicose, bem como o método de avaliação clínica dessa terapia e os possíveis efeitos colaterais de seu uso. Foram revisados prontuários de 20 pacientes submetidos à laserterapia. Ao todo, 34 unhas afetadas foram avaliadas de acordo com o Índice de Severidade de Onicomicose (ISO). Esse índice analisa a área de envolvimento da unha, a proximidade da doença com a matriz ungueal, a ocorrência de dermatofitoma e a presença de hiperqueratose subungueal > 2 mm, gerando uma pontuação que classifica a onicomicose como leve, moderada ou grave. A determinação do ISO foi realizada antes do tratamento e após um período de acompanhamento, em média, de oito meses. A comparação entre o ISO Inicial e o ISO Final nas 34 unhas submetidas à laserterapia mostrou diferença significativa, porém, com baixa associação entre essas variáveis. Com relação à área de envolvimento e à pontuação numérica referente ao ISO, houve, no geral, uma redução dessas medidas. Esses dados apontam para uma tendência à melhora da onicomicose por meio do tratamento com o laser Nd:YAG 1.064 nm. O ISO permitiu uma análise clínica adequada da resposta à laserterapia. Os efeitos colaterais locais apresentados durante a aplicação do laser não causaram desconforto acentuado na maioria dos pacientes, demonstrando que o procedimento é bem tolerado.
Resumo:
An optimized ZnO:Al/a-pin SixCl1-x:H/Al configuration for the laser scanned photodiode (LSP) imaging detector is proposed. The LSP utilizes light induced depletion layers as detector and a laser beam for readout. The effect of the sensing element structure, cell configuration and light source flux are investigated and correlated with the sensor output characteristics. Experimental data reveal that the large optical gap and the low conductivity of the doped a-SixC1-x:H layers are responsible by an induced inversion layer at the illuminated interfaces which blocks the carrier collection. These insulator-like layers act as MIS gates preventing image smearing. The physical background of the LSP is discussed.
Resumo:
Amorphous glass/ZnO-Al/p(a-Si:H)/i(a-Si:H)/n(a-Si1-xCx:H)/Al imagers with different n-layer resistivities were produced by plasma enhanced chemical vapour deposition technique (PE-CVD). An image is projected onto the sensing element and leads to spatially confined depletion regions that can be readout by scanning the photodiode with a low-power modulated laser beam. The essence of the scheme is the analog readout, and the absence of semiconductor arrays or electrode potential manipulations to transfer the information coming from the transducer. The influence of the intensity of the optical image projected onto the sensor surface is correlated with the sensor output characteristics (sensitivity, linearity blooming, resolution and signal-to-noise ratio) are analysed for different material compositions (0.5 < x < 1). The results show that the responsivity and the spatial resolution are limited by the conductivity of the doped layers. An enhancement of one order of magnitude in the image intensity signal and on the spatial resolution are achieved at 0.2 mW cm(-2) light flux by decreasing the n-layer conductivity by the same amount. A physical model supported by electrical simulation gives insight into the image-sensing technique used.
Resumo:
Chromium oxides, CrxOy, are of great interest due to the wide variety of their technological applications. Among them, CrO2 has been extensively investigated in recent years because it is an attractive compound for use in spintronic heterostructures. However, its synthesis at low temperatures has been a difficult task due to the metastable nature of this oxide. This is indeed essential to ensure interface quality and the ability to coat thermal-sensitive materials such as those envisaged in spintronic devices. Pulsed Laser Deposition (PLD) is a technique that has the potential to meet the requirements stated above. In this work, we describe our efforts to grow chromium oxide thin films by PLD from Cr8O21 targets, using a KrF excimer laser. The as-deposited films were investigated by X-ray diffraction and Rutherford backscattering spectrometry. Structural and chemical composition studies showed that the films consist of a mixture of amorphous chromium oxides exhibiting different stoichiometries depending on the processing parameters, where nanocrystals of mainly Cr2O3 are dispersed. The analyses do not exclude the possibility of co-deposition of Cr2O3 and a low fraction of CrO2.
Resumo:
This paper reports on the structural and optical properties of Co-doped TiO2 thin films grown onto (0001)Al2O3 substrates by non-reactive pulsed laser deposition (PLD) using argon as buffer gas. It is shown that by keeping constant the substrate temperature at as low as 310 degrees C and varying only the background gas pressure between 7 Pa and 70 Pa, it is possible to grow either epitaxial rutile or pure anatase thin films, as well as films with a mixture of both polymorphs. The optical band gaps of the films are red shifted in comparison with the values usually reported for undoped TiO2, which is consistent with n-type doping of the TiO2 matrix. Such band gap red shift brings the absorption edge of the Co-doped TiO2 films into the visible region, which might favour their photocatalytic activity. Furthermore, the band gap red shift depends on the films' phase composition, increasing with the increase of the Urbach energy for increasing rutile content. (C) 2012 Elsevier B.V. All rights reserved.
Resumo:
We report the fabrication of planar sub-micron gratings in silicon with a period of 720 nm using a modified Michelson interferometer and femtosecond laser radiation. The gratings consist of alternated stripes of laser ablated and unmodified material. Ablated stripes are bordered by parallel ridges which protrude above the unmodified material. In the regions where ridges are formed, the laser radiation intensity is not sufficient to cause ablation. Nevertheless, melting and a significant temperature increase are expected, and ridges may be formed due to expansion of silicon during resolidification or silicon oxidation. These conclusions are consistent with the evolution of the stripes morphology as a function of the distance from the center of the grating. (C) 2013 Elsevier Ltd. All rights reserved.
Resumo:
To determine self-consistently the time evolution of particle size and their number density in situ multi-angle polarization-sensitive laser light scattering was used. Cross-polarization intensities (incident and scattered light intensities with opposite polarization) measured at 135 degrees and ex situ transmission electronic microscopy analysis demonstrate the existence of nonspherical agglomerates during the early phase of agglomeration. Later in the particle time development both techniques reveal spherical particles again. The presence of strong cross-polarization intensities is accompanied by low-frequency instabilities detected on the scattered light intensities and plasma emission. It is found that the particle radius and particle number density during the agglomeration phase can be well described by the Brownian free molecule coagulation model. Application of this neutral particle coagulation model is justified by calculation of the particle charge whereby it is shown that particles of a few tens of nanometer can be considered as neutral under our experimental conditions. The measured particle dispersion can be well described by a Brownian free molecule coagulation model including a log-normal particle size distribution. (C) 1996 American Institute of Physics.
Resumo:
Retinal imaging with a confocal scaning laser Ophthalmoscope (cSLO) involves scanning a small laser beam over the retina and constructing an image from the reflected light. By applying the confocal principle, tomographic images can be produced by measuring a sequence of slices at different depths. However, the thickness of such slices, when compared with the retinal thickness, is too large to give useful 3D retinal images, if no processing is done. In this work, a prototype cSLO was modified in terms hardware and software to give the ability of doing the tomographic measurements with the maximum theoretical axial resolution possible. A model eye was built to test the performance of the system. A novel algorithm has been developed which fits a double Gaussian curve to the axial intensity profiles generated from a stack of images slices. The underlying assumption is that the laser light has mainly been reflected by two structures in the retina, the internal limiting membrane and the retinal pigment epithelium. From the fitted curve topographic images and novel thickness images of the retina can be generated. Deconvolution algorithms have also been developed to improve the axial resolution of the system, using a theoretically predicted cSLO point spread function. The technique was evaluated using measurements made on a model eye, four normal eyes and seven eyes containing retinal pathology. The reproducibility, accuracy and physiological measurements obtained, were compared with available published data, and showed good agreement. The difference in the measurements when using a double rather than a single Gaussian model was also analysed.
Resumo:
We report the fabrication of planar sub-micron gratings in silicon with a period of 720 nm using a modified Michelson interferometer and femtosecond laser radiation. The gratings consist of alternated stripes of laser ablated and unmodified material. Ablated stripes are bordered by parallel ridges which protrude above the unmodified material. In the regions where ridges are formed, the laser radiation intensity is not sufficient to cause ablation. Nevertheless, melting and a significant temperature increase are expected, and ridges may be formed due to expansion of silicon during resolidification or silicon oxidation. These conclusions are consistent with the evolution of the stripes morphology as a function of the distance from the center of the grating.
Resumo:
Applied Physics B Lasers and Optics, vol.71
Resumo:
A cross-sectional case-control study designed to evaluate the role of malnutrition in the association between the intensity of Schistosoma mansoni infection and clinical schistosomiasis, was conducted in an area with both low frequency of infection and low morbidity of schistosomiasis in Brazil. Cases (256) were patients with a positive stool examination for S. mansoni; their geometrical mean number of eggs/gram of feces was 90. Controls (256) were a random sample of the negative participants paired to the cases by age, sex and length of residence in the area. The clinical signs and symptoms found to be associated with S. mansoni infection, comparing cases and controls, were blood in stools and presence of a palpable liver. A linear trend in the relative odds of these signs and symptoms with increasing levels of infection was detected. Adjusting by the level of egg excretion, the existence of an interaction between palpable liver and ethnic group (white) was suggested. No differences in the nutritional status of infected and non-infected participants were found.
Resumo:
Amorphous and crystalline sputtered boron carbide thin films have a very high hardness even surpassing that of bulk crystalline boron carbide (≈41 GPa). However, magnetron sputtered B-C films have high friction coefficients (C.o.F) which limit their industrial application. Nanopatterning of materials surfaces has been proposed as a solution to decrease the C.o.F. The contact area of the nanopatterned surfaces is decreased due to the nanometre size of the asperities which results in a significant reduction of adhesion and friction. In the present work, the surface of amorphous and polycrystalline B-C thin films deposited by magnetron sputtering was nanopatterned using infrared femtosecond laser radiation. Successive parallel laser tracks 10 μm apart were overlapped in order to obtain a processed area of about 3 mm2. Sinusoidal-like undulations with the same spatial period as the laser tracks were formed on the surface of the amorphous boron carbide films after laser processing. The undulations amplitude increases with increasing laser fluence. The formation of undulations with a 10 μm period was also observed on the surface of the crystalline boron carbide film processed with a pulse energy of 72 μJ. The amplitude of the undulations is about 10 times higher than in the amorphous films processed at the same pulse energy due to the higher roughness of the films and consequent increase in laser radiation absorption. LIPSS formation on the surface of the films was achieved for the three B-C films under study. However, LIPSS are formed under different circumstances. Processing of the amorphous films at low fluence (72 μJ) results in LIPSS formation only on localized spots on the film surface. LIPSS formation was also observed on the top of the undulations formed after laser processing with 78 μJ of the amorphous film deposited at 800 °C. Finally, large-area homogeneous LIPSS coverage of the boron carbide crystalline films surface was achieved within a large range of laser fluences although holes are also formed at higher laser fluences.
Resumo:
The purpose of this study was to evaluate and compare pain as reported by outpatients with fibromyalgia, osteoarthritis, and low back pain, in view of designing more adequate physical therapy treatment. PATIENTS AND METHODS: A Portuguese version of the McGill Pain Questionnaire - where subjects are asked to choose, from lists of pre-categorized words, one or none that best describes what they feel - was used to assess pain intensity and quality of 64 patients, of which 24 had fibromyalgia, 22 had osteoarthritis, and 18 had low back pain. The pre-categorized words were organized into 4 major classes -- sensory, affective, evaluative, and miscellaneous. RESULTS: Patients with fibromyalgia reported, comparatively, more intense pain through their choice of pain descriptors, both sensory and affective; they also chose a higher number of words from these classes than patients in the other groups and were the only ones to choose specific affective descriptors such as "vicious", "wretched", "exhausting", "blinding". CONCLUSION: Assuming that each disease presents unique qualities of pain experience, and that these can be pointed out by means of this questionnaire by patients' choice of specific groups of words, the findings suggest that fibromyalgia include not only a physical component, but also a psycho-emotional component, indicating that they require both emotional/affective and physical care.