995 resultados para image-guided radiotherapy
Resumo:
BACKGROUND: Letrozole radiosensitises breast cancer cells in vitro. In clinical settings, no data exist for the combination of letrozole and radiotherapy. We assessed concurrent and sequential radiotherapy and letrozole in the adjuvant setting. METHODS: This phase 2 randomised trial was undertaken in two centres in France and one in Switzerland between Jan 12, 2005, and Feb 21, 2007. 150 postmenopausal women with early-stage breast cancer were randomly assigned after conserving surgery to either concurrent radiotherapy and letrozole (n=75) or sequential radiotherapy and letrozole (n=75). Randomisation was open label with a minimisation technique, stratified by investigational centres, chemotherapy (yes vs no), radiation boost (yes vs no), and value of radiation-induced lymphocyte apoptosis (< or = 16% vs >16%). Whole breast was irradiated to a total dose of 50 Gy in 25 fractions over 5 weeks. In the case of supraclavicular and internal mammary node irradiation, the dose was 44-50 Gy. Letrozole was administered orally once daily at a dose of 2.5 mg for 5 years (beginning 3 weeks pre-radiotherapy in the concomitant group, and 3 weeks post-radiotherapy in the sequential group). The primary endpoint was the occurrence of acute (during and within 6 weeks of radiotherapy) and late (within 2 years) radiation-induced grade 2 or worse toxic effects of the skin. Analyses were by intention to treat. This study is registered with ClinicalTrials.gov, number NCT00208273. FINDINGS: All patients were analysed apart from one in the concurrent group who withdrew consent before any treatment. During radiotherapy and within the first 12 weeks after radiotherapy, 31 patients in the concurrent group and 31 in the sequential group had any grade 2 or worse skin-related toxicity. The most common skin-related adverse event was dermatitis: four patients in the concurrent group and six in the sequential group had grade 3 acute skin dermatitis during radiotherapy. At a median follow-up of 26 months (range 3-40), two patients in each group had grade 2 or worse late effects (both radiation-induced subcutaneous fibrosis). INTERPRETATION: Letrozole can be safely delivered shortly after surgery and concomitantly with radiotherapy. Long-term follow-up is needed to investigate cardiac side-effects and cancer-specific outcomes. FUNDING: Novartis Oncology France.
Resumo:
Extended abstract.
Resumo:
This article reports on a lossless data hiding scheme for digital images where the data hiding capacity is either determined by minimum acceptable subjective quality or by the demanded capacity. In the proposed method data is hidden within the image prediction errors, where the most well-known prediction algorithms such as the median edge detector (MED), gradient adjacent prediction (GAP) and Jiang prediction are tested for this purpose. In this method, first the histogram of the prediction errors of images are computed and then based on the required capacity or desired image quality, the prediction error values of frequencies larger than this capacity are shifted. The empty space created by such a shift is used for embedding the data. Experimental results show distinct superiority of the image prediction error histogram over the conventional image histogram itself, due to much narrower spectrum of the former over the latter. We have also devised an adaptive method for hiding data, where subjective quality is traded for data hiding capacity. Here the positive and negative error values are chosen such that the sum of their frequencies on the histogram is just above the given capacity or above a certain quality.
Resumo:
This letter presents a lossless data hiding scheme for digital images which uses an edge detector to locate plain areas for embedding. The proposed method takes advantage of the well-known gradient adjacent prediction utilized in image coding. In the suggested scheme, prediction errors and edge values are first computed and then, excluding the edge pixels, prediction error values are slightly modified through shifting the prediction errors to embed data. The aim of proposed scheme is to decrease the amount of modified pixels to improve transparency by keeping edge pixel values of the image. The experimental results have demonstrated that the proposed method is capable of hiding more secret data than the known techniques at the same PSNR, thus proving that using edge detector to locate plain areas for lossless data embedding can enhance the performance in terms of data embedding rate versus the PSNR of marked images with respect to original image.
Resumo:
Peer-reviewed
Resumo:
Purpose/Objective(s): Letrozole radiosensitizes breast cancer cells in vitro. In clinical settings, no data exist for the combination of letrozole and radiotherapy. We assessed concurrent and sequential radiotherapy and letrozole in the adjuvant setting.Materials/Methods: The present study is registered with ClinicalTrials.gov, number NCT00208273. This Phase 2 randomized trial was undertaken in two centers in France and one in Switzerland between January 12, 2005, and February 21, 2007. One hundred fifty postmenopausal women with early-stage breast cancer were randomly assigned after conserving surgery to either concurrent radiotherapy and letrozole (n = 75) or sequential radiotherapy and letrozole (n = 75). Randomization was open label with a minimization technique, stratified by investigational centers, chemotherapy (yes vs. no), radiation boost (yes vs. no), and value of radiation-induced lymphocyte apoptosis (#16% vs. .16%). The whole breast was irradiated to a total dose of 50 Gy in 25 fractions over 5 weeks. In the case of supraclavicular and internal mammary node irradiation, the dose was 44 - 50 Gy. Letrozole was administered orally once daily at a dose of 2 - 5 mg for 5 years (beginning 3 weeks pre-radiotherapy in the concomitant group, and 3 weeks postradiotherapy in the sequential group). The primary endpoint was the occurrence of acute (during and within 6 weeks of radiotherapy) and late (within 2 years) radiation-induced Grade 2 or worse toxic effects of the skin and lung (functional pulmonary test and lung CT-scan). Analyses were by intention-to-treat. The long-term follow-up after 2 years was only performed in Montpellier (n = 121) and evaluated skin toxicity (clinical examination every 6 months), lung fibrosis (one CT-scan yearly), cosmetic outcome.Results: All patients were analyzed apart from 1 in the concurrent group who withdrew consent before any treatment.Within the first 2 years (n = 149), no lung toxicity was identified by CT scan and no modification from baseline was noted by the lung diffusion capacity test. Two patients in each group had Grade 2 or worse late effects (both radiation-induced subcutaneous fibrosis [RISF]). After 2 years (n = 121), and with a median follow-up of 50 months (38-62), 2 patients (1 in each arm) presented a Grade 3 RISF. No lung toxicity was identified by CT scan. Cosmetic results (photographies) and quality of life was good to excellent. All patients who had Grade 3 subcutaneous fibrosis had an RILA value of 16% or less, irrespective of the sequence with letrozole.Conclusions:With long-term follow-up, letrozole can be safely delivered shortly after surgery and concomitantly with radiotherapy.
Resumo:
BACKGROUND: Patients with BM rarely survive .6 months and are commonly excluded from clinical trials. We aimed at improving outcome by exploring 2 combined modality regimens with at the time novel agents for which single-agent activity had been shown. METHODS: NSCLC patients with multiple BM were randomized to WBRT (10 × 3 Gy) and either GFT 250 mg p.o. daily or TMZ 75 mg/m2 p.o. daily ×21/28 days, starting on Day 1 of RT and to be continued until PD. Primary endpoint was overall survival, a Simon's optimal 2-stage design was based on assumptions for the 3-month survival rate. Cognitive functioning and quality of life were also evaluated. RESULTS: Fifty-nine patients (36 M, 23 F; 9 after prior chemo) were included. Median age was 61 years (range 46-82), WHO PS was 0 in 18 patients, 1 in 31 patients, and 2 in 10 patients. All but 1 patients had extracranial disease; 33 of 43 (TMZ) and 15 of 16 (GFT) had adenocarcinoma histology. GFT arm was closed early after stage 1 analysis when the prespecified 3-mo survival rate threshold (66%) was not reached, causes of death were not GFT related. Main causes of death were PD in the CNS 24%, systemic 41%, both 8%, and toxicity 10% [intestinal perforation (2 patients), pneumonia (2), pulmonary emboli (1), pneumonitis NOS (1), seizure (1)]. We summarize here other patients' characteristics for the 2 trial arms: TMZ (n ¼ 43)/GFT (n ¼ 16); median treatment duration: 1.6 /1.8 mo; Grade 3-4 toxicity: lymphopenia 5 patients (12%)/0; fatigue 8 patients (19%)/2 patients (13%). Survival data for TMZ/GFT arms: 3-month survival rate: 58.1% (95% CI 42.1-73)/62.5% (95% CI 35- 85); median OS: 4.9 months (95% CI 2.5-5.6)/6.3 months (95% CI 2.2- 14.6); median PFS: 1.8 months (95% CI 1.5-1.8)/1.8 (95% CI 1.1-3.9); median time to neurol. progr.: 8.0 months (95% CI 2.2-X)/4.8 (95% CI 3.9-10.5). In a model to predict survival time including the variables' age, PS, number of BM, global QL, total MMSE score, and subjective cognitive function, none of the variables accounted for a significant improvement in survival time. CONCLUSIONS: The combinations of WBRT with GFT or TMZ were feasible. However, in this unselected patient population, survival remains poor and a high rate of complication was observed. Four patients died as a result of high-dose corticosteroids. Preliminary evaluation of cognitive function andQL failed to show significant improvement. Indications and patient selection for palliative treatment should be revisited and careful monitoring and supportive care is required. Research and progress for this frequent clinical situation is urgently needed. Trial partly supported by AstraZeneca (Switzerland), Essex Chemie (Switzerland) and Swiss Federal Government.
Resumo:
Background: We examined one's own body image perception and its association with reported weight-related behavior among adolescents of a rapidly developing country in the African region. Methods: We conducted a school-based survey of 1432 students aged 11-17 years in the Seychelles. Weight and height were measured, and thinness, normal weight and overweight were assessed along standard criteria. A self-administered and anonymous questionnaire was administered. Perception of body image was assessed using both a closed-ended question (CEQ) and the Stunkard's pictorial silhouettes (SPS). Finally, a question assessed voluntary attempts to change weight. Results: Overall, 14.1% of the students were thin, 63.9% were normal-weight, and 22.0% were overweight or obese. There was fair agreement between actual weight status and self-perceived body image based on either CEQ or SPS. However, a substantial proportion of the overweight students did not consider themselves as overweight (SPS: 24%, CEQ: 34%) and, inversely, a substantial proportion of the normal-weight students considered themselves as too thin (SPS: 29%, CEQ: 15%). Among the overweight students, an adequate attempt to lose weight was reported more often by boys and girls who perceived themselves as overweight vs. not overweight (72-88% vs. 40-71%, p <0.05 for most comparisons). Among the normal-weight students, an inadequate attempt to gain weight was reported more often by boys and girls who perceived themselves as thin vs. not thin (27-68% vs. 11-19%, p <0.05). Girls had leaner own body ideals than boys. Conclusions: We found that substantial proportions of overweight students did not perceive themselves as overweight and/or did not want to lose weight and, inversely, that many normalweight students perceived themselves as too thin and/or wanted to gain weight: this points to forces that can drive the upwards overweight trends. Appropriate perception of one's weight was associated with adequate weight-control behavior, although not strongly, emphasizing that appropriate weight perception is only one of several factors driving adequate weight-related behavior. These findings emphasize the need to address appropriate perception of one's own weight and adequate weight-related behavior in adolescents for both individual and community weight-related interventions.
Resumo:
Introduction: EORTC trial 22991 randomly assessed the addition of concomitant and adjuvant short-term hormonal therapy to curative conformal/intensity-modulated radiotherapy (RT) for intermediate risk localized prostate cancer. We report the acute toxicity (assessed weekly during RT) for the organs at risk (genito-urinary (GU) and gastro-intestinal (GI)) in relation to radiation parameters. Material and Methods: Eligibility criteria were age _80 years, PSA _ 50 ng/ml, N0M0 and either tumour stage cT2a (1997 UICC TNM) or cT1b-c combined with PSA_10 ng/ml and/or Gleason score _7. We report toxicity for all eligible patients who received the planned RT with documented acute toxicity (CTCAEv.2) and RT-quality assurance parameters. The RT dose (70 Gy, 74 Gy or 78 Gy) and technique (3DCRT vs IRMT) were per institution choice, the randomization was stratified for institution. Statistical significance was set at 0.05. (ClinicalTrials.gov: NCT00021450) Results: Of 819 randomized patients, 28 were excluded from the analysis (3 with <60 Gy RT, 25 with missing information). Of the 791 analysed patients, 652 (82.4%) were treated with 3D-CRT, 139 with IMRT. In the 3DCRT group, 195 patients (29.9%) were treated with a total prescribed dose of 70 Gy; 376 (57.7%) with 74 Gy and 81 (12.4%) with 78 Gy. In the IMRT group, 28 (20.1%) were treated to a total dose of 74 Gy and 111 (79.9%) with 78 Gy. Overall, only 7 of 791 patients (0.9%) had grade 3 GI toxicity during RT: diarrhea (N = 6), rectal bleeding (N = 1) and proctitis (N = 1). Fifty patients (6.3%) had grade 3 GU toxicity: urinary frequency (N = 38, 4.6%), dysuria (N = 14, 1.7%), urinary retention (N = 11, 1.3%), urinary incontinence (N = 2) and hematuria (N = 1). No grade 4 toxicity was reported. Hormonal treatment did not influence the risk of side effects (p>0.05). The risk of grade _2 GI toxicity significantly correlated to D50%-rectum (p = 0.004) with a cut-of value of 44 Gy. The risk of grade _2 GU toxicity was moderately affected by Dmax-bladder (p = 0.051). Overall, only 14 patients (1.8%) had residual grade 3 toxicities one month after RT. Conclusion: 3D-CRT and IMRT up to 78 Gy is well tolerated. Dmaxbladder and D50%-rectum were related to the risk of grade_2 GU and GI toxicity, respectively. IMRT lowered D50% rectum and Dmax-bladder. An irradiated volume >400 cc for 3D-RT and a dose of 78 Gy, even for IMRT, negatively affected those parameters and increased the risk for toxicity.
Resumo:
Image filtering is a highly demanded approach of image enhancement in digital imaging systems design. It is widely used in television and camera design technologies to improve the quality of an output image to avoid various problems such as image blurring problem thatgains importance in design of displays of large sizes and design of digital cameras. This thesis proposes a new image filtering method basedon visual characteristics of human eye such as MTF. In contrast to the traditional filtering methods based on human visual characteristics this thesis takes into account the anisotropy of the human eye vision. The proposed method is based on laboratory measurements of the human eye MTF and takes into account degradation of the image by the latter. This method improves an image in the way it will be degraded by human eye MTF to give perception of the original image quality. This thesis gives a basic understanding of an image filtering approach and the concept of MTF and describes an algorithm to perform an image enhancement based on MTF of human eye. Performed experiments have shown quite good results according to human evaluation. Suggestions to improve the algorithm are also given for the future improvements.
Resumo:
The aim of radiotherapy is to deliver enough radiation to the tumor in order to achieve maximum tumour control in the irradiated volume with as few serious complications as possible with an irradiation dose as low as possible to normal tissue. The quality of radiotherapy is essential for optimal treatment and quality control is to reduce the bias in clinical trials avoiding possible major deviations. The assurance and quality control programs have been developed in large european (EORTC, GORTEC) and american cooperative groups (RTOG) of radiation oncology since the 1980s. We insist here on the importance of quality assurance in radiotherapy and the current status in this domain and the criteria for quality control especially for current clinical trials within GORTEC are discussed here.
Resumo:
The aim of the present study is to determine the level of correlation between the 3-dimensional (3D) characteristics of trabecular bone microarchitecture, as evaluated using microcomputed tomography (μCT) reconstruction, and trabecular bone score (TBS), as evaluated using 2D projection images directly derived from 3D μCT reconstruction (TBSμCT). Moreover, we have evaluated the effects of image degradation (resolution and noise) and X-ray energy of projection on these correlations. Thirty human cadaveric vertebrae were acquired on a microscanner at an isotropic resolution of 93μm. The 3D microarchitecture parameters were obtained using MicroView (GE Healthcare, Wauwatosa, MI). The 2D projections of these 3D models were generated using the Beer-Lambert law at different X-ray energies. Degradation of image resolution was simulated (from 93 to 1488μm). Relationships between 3D microarchitecture parameters and TBSμCT at different resolutions were evaluated using linear regression analysis. Significant correlations were observed between TBSμCT and 3D microarchitecture parameters, regardless of the resolution. Correlations were detected that were strongly to intermediately positive for connectivity density (0.711≤r(2)≤0.752) and trabecular number (0.584≤r(2)≤0.648) and negative for trabecular space (-0.407 ≤r(2)≤-0.491), up to a pixel size of 1023μm. In addition, TBSμCT values were strongly correlated between each other (0.77≤r(2)≤0.96). Study results show that the correlations between TBSμCT at 93μm and 3D microarchitecture parameters are weakly impacted by the degradation of image resolution and the presence of noise.
Resumo:
We study the impact of sampling theorems on the fidelity of sparse image reconstruction on the sphere. We discuss how a reduction in the number of samples required to represent all information content of a band-limited signal acts to improve the fidelity of sparse image reconstruction, through both the dimensionality and sparsity of signals. To demonstrate this result, we consider a simple inpainting problem on the sphere and consider images sparse in the magnitude of their gradient. We develop a framework for total variation inpainting on the sphere, including fast methods to render the inpainting problem computationally feasible at high resolution. Recently a new sampling theorem on the sphere was developed, reducing the required number of samples by a factor of two for equiangular sampling schemes. Through numerical simulations, we verify the enhanced fidelity of sparse image reconstruction due to the more efficient sampling of the sphere provided by the new sampling theorem.