829 resultados para hip replacement
Resumo:
The adequate replacement dose of estrogens during infancy and childhood is still not known in girls. Aromatase deficiency offers an excellent model to study how much estrogens are needed during infancy, childhood and adulthood.
Resumo:
AIMS: The goal of this study was to assess the prevalence of left ventricular (LV) hypertrophy in patients with aortic stenosis late (>6 months) after aortic valve replacement and its impact on cardiac-related morbidity and mortality. METHODS AND RESULTS: In a single tertiary centre, echocardiographic data of LV muscle mass were collected. Detailed information of medical history and angiographic data were gathered. Ninety-nine of 213 patients (46%) had LV hypertrophy late (mean 5.8 +/- 5.4 years) after aortic valve replacement. LV hypertrophy was associated with impaired exercise capacity, higher New York Heart Association dyspnoea class, a tendency for more frequent chest pain expressed as higher Canadian Cardiovascular Society class, and more rehospitalizations. 24% of patients with normal LV mass vs. 39% of patients with LV hypertrophy reported cardiac-related morbidity (p = 0.04). In a multivariate logistic regression model, LV hypertrophy was an independent predictor of cardiac-related morbidity (odds ratio 2.31, 95% CI 1.08 to 5.41), after correction for gender, baseline ejection fraction, and coronary artery disease and its risk factors. Thirty seven deaths occurred during a total of 1959 patient years of follow-up (mean follow-up 9.6 years). Age at aortic valve replacement (hazard ratio 1.85, 95% CI 1.39 to 2.47, for every 5 years increase in age), coexisting coronary artery disease at the time of surgery (hazard ratio 3.36, 95% CI 1.31 to 8.62), and smoking (hazard ratio 4.82, 95% CI 1.72 to 13.45) were independent predictors of overall mortality late after surgery, but not LV hypertrophy. CONCLUSIONS: In patients with aortic valve replacement for isolated aortic stenosis, LV hypertrophy late after surgery is associated with increased morbidity.
Resumo:
Synovial chondromatosis of the hip is a rare disorder with few published reports regarding treatment and outcomes, and therefore, selecting the optimal surgical treatment is difficult. We reviewed eight patients with monoarticular synovial chondromatosis of the hip who had joint débridement and a modified total synovectomy performed through a surgical hip dislocation with a trochanteric flip osteotomy. Patients were evaluated for recurrence of disease, progression of osteoarthritis, clinical outcomes, and subsequent reoperations. The minimum followup was 4 years (mean, 6.5 years). At final review, no patient had recurrence of disease. Two patients had progression of osteoarthritis requiring total hip arthroplasties at 5 and 10 years after the initial surgical intervention. These patients did not show recurrent disease on histologic examination of the synovial membrane at the time of the arthroplasty. The six patients with preserved joints were followed up for a mean of 6.2 years. The mean Merle d'Aubigné and Postel score in this group was 16.5 points (range, 15-18 points) at the latest followup. There were no major or minor complications related to this treatment. Our midterm results suggest that open débridement with modified total synovectomy is an effective treatment that prevents recurrence of disease and provides substantial pain relief. Surgical hip dislocation allows safe and complete access to the joint for débridement and synovectomy with no added morbidity.
Resumo:
BACKGROUND: We hypothesized that certain patient characteristics have different effects on the risk of early stem loosening in total hip arthroplasty (THA). We therefore conducted a case-control study using register-database records with the aim of identifying patient-specific risk factors associated with radiographic signs of aseptic loosening of the femoral component in THA. METHOD: Data were derived from a multinational European registry and were collected over a period of 25 years. 725 cases with radiographic signs of stem loosening were identified and matched to 4,310 controls without any signs of loosening. Matching criteria were type of implant, size of head, date of operation, center of primary intervention, and follow-up time. The risk factors analyzed were age at operation, sex, diagnosis and previous ipsilateral operations, height, weight, body mass index and mobility based on the Charnley classification. RESULTS: Women showed significantly lower risk of radiographic loosening than men (odds ratio (OR) 0.64). Age was also a strong factor: risk decreased by 1.8% for each additional year of age at the time of surgery. Height and weight were not associated with risk of loosening. A higher body mass index, however, increased the risk of stem loosening to a significant extent (OR 1.03) per additional unit of BMI. Charnley Class B, indicating restricted mobility, was associated with lower risk of loosening (OR 0.78). INTERPRETATION: An increased activity level, as seen in younger patients and those with unrestricted mobility, is an important factor in the etiology of stem loosening. If combined with high BMI, the risk of stem loosening within 10 years is even higher. A younger person should not be denied the benefits of a total hip arthroplasty but must accept that the risk of future failure is increased.
Resumo:
OBJECTIVE: Postmenopausal bone loss and osteoporotic fractures can be prevented by hormone replacement therapy (HRT). However, opposed HRT may increase the risk of breast cancer above that associated with estrogen alone and in non-hysterectomized women estrogen substitution alone increases the risk of uterine cancer, which triggered renewed interest in long-cycle HRT regimens (estrogen replacement therapy with progesterone-free intervals up to 6 months). The effects on bone of such long-cycle HRT regimens are unknown. The objective of the present study was to compare the effects on bone and the endometrium of long-cycle HRT and conventional HRT. METHODS: Seventy-three healthy non-hysterectomized postmenopausal women were randomized to either conventional HRT (estradiol (E2) 2 mg/d during 12 days, E2 2 mg/d plus 1 mg/d of norethisterone acetate (NETA) during 10 days, E2 1 mg/d for 6 days) or long-cycle HRT treatment (two cycles with E2 2 mg/d during 28 days, followed by one cycle of conventional HRT and repeated every 3 months). Primary endpoint was the change in bone mineral density (BMD) at the lumbar spine (LS) over 24 months. RESULTS: BMD at LS increased significantly versus baseline in both treatment groups (conventional HRT +3.8 +/- 0.6%, long-cycle HRT +3.3 +/- 0.5%, p < 0.0001 for both) with no significant difference between treatment groups over 24 months. Similar significant BMD increases versus baseline were observed at the femoral neck, while biochemical markers of bone turnover (osteocalcin and deoxypyridinoline) were significantly decreased over 24 months. There were no endometrial or breast related adverse events reported. CONCLUSION: Long-cycle HRT may be a valid alternative to conventional HRT with regard to protection against postmenopausal bone loss.
Resumo:
BACKGROUND: In a prospective, nonrandomized study the outcome in terms of rehabilitation and complications of total hip arthroplasty (THA) through a superior capsulotomy exposure (study group) was compared to THA performed through a direct lateral exposure (control group). PATIENTS AND METHODS: The study group (106 THA) and the control group (107 THA) were controlled for complexity and had no significant differences in age, sex, diagnosis, or body mass index. RESULTS: The study group had improved recovery at 6 weeks after surgery which was statistically significant (p<0.001). In addition, the study group had a lower incidence of perioperative complications. CONCLUSION: The current study demonstrates the potential that less-invasive surgical techniques with the philosophy of maximally preserving the abductors, posterior capsule, and short rotators may result in a safer operation with an accelerated recovery.
Resumo:
PURPOSE: To perform baseline T(2) mapping of the hips of healthy volunteers, focusing on topographic variation, because no detailed study has involved hips. T(2) mapping is a quantitative magnetic resonance imaging (MRI) technique that evaluates cartilage matrix components. MATERIALS AND METHODS: Hips of 12 healthy adults (six men and six women; mean age = 29.5 +/- 4.9 years) were studied with a 3.0-Tesla MRI system. T(2) measurement in the oblique-coronal plane used a multi-spin-echo (MSE) sequence. Femoral cartilage was divided into 12 radial sections; acetabular cartilage was divided into six radial sections, and each section was divided into two layers representing the superficial and deep halves of the cartilage. T(2) of these sections and layers were measured. RESULTS: Femoral cartilage T(2) was the shortest (-20 degrees to 20 degrees and -10 degrees to 10 degrees , superficial and deep layers), with an increase near the magic angle (54.7 degrees ). Acetabular cartilage T(2) in both layers was shorter in the periphery than the other parts, especially at 20 degrees to 30 degrees . There were no significant differences in T(2) between right and left hips or between men and women. CONCLUSION: Topographic variation exists in hip cartilage T(2) in young, healthy adults. These findings should be taken into account when T(2) mapping is applied to patients with degenerative cartilage. J. Magn. Reson. Imaging 2007;26:165-171. (c) 2007 Wiley-Liss, Inc.
Resumo:
OBJECTIVE: The purpose of this study was to review the diagnosis on MRI and radiography of 24 renal transplant recipients with hip pain suspicious for avascular necrosis and to investigate whether there is an association between kidney transplant patients with end-stage renal disease and symptomatic gluteus minimus and medius tendon abnormality. CONCLUSION: Symptomatic gluteus minimus and medius tendon lesions and abnormalities can occur in renal allograft recipients. The MRI findings of this entity allow an alternative diagnosis in this patient population.
Resumo:
To compare the prediction of hip fracture risk of several bone ultrasounds (QUS), 7062 Swiss women > or =70 years of age were measured with three QUSs (two of the heel, one of the phalanges). Heel QUSs were both predictive of hip fracture risk, whereas the phalanges QUS was not. INTRODUCTION: As the number of hip fracture is expected to increase during these next decades, it is important to develop strategies to detect subjects at risk. Quantitative bone ultrasound (QUS), an ionizing radiation-free method, which is transportable, could be interesting for this purpose. MATERIALS AND METHODS: The Swiss Evaluation of the Methods of Measurement of Osteoporotic Fracture Risk (SEMOF) study is a multicenter cohort study, which compared three QUSs for the assessment of hip fracture risk in a sample of 7609 elderly ambulatory women > or =70 years of age. Two QUSs measured the heel (Achilles+; GE-Lunar and Sahara; Hologic), and one measured the heel (DBM Sonic 1200; IGEA). The Cox proportional hazards regression was used to estimate the hazard of the first hip fracture, adjusted for age, BMI, and center, and the area under the ROC curves were calculated to compare the devices and their parameters. RESULTS: From the 7609 women who were included in the study, 7062 women 75.2 +/- 3.1 (SD) years of age were prospectively followed for 2.9 +/- 0.8 years. Eighty women reported a hip fracture. A decrease by 1 SD of the QUS variables corresponded to an increase of the hip fracture risk from 2.3 (95% CI, 1.7, 3.1) to 2.6 (95% CI, 1.9, 3.4) for the three variables of Achilles+ and from 2.2 (95% CI, 1.7, 3.0) to 2.4 (95% CI, 1.8, 3.2) for the three variables of Sahara. Risk gradients did not differ significantly among the variables of the two heel QUS devices. On the other hand, the phalanges QUS (DBM Sonic 1200) was not predictive of hip fracture risk, with an adjusted hazard risk of 1.2 (95% CI, 0.9, 1.5), even after reanalysis of the digitalized data and using different cut-off levels (1700 or 1570 m/s). CONCLUSIONS: In this elderly women population, heel QUS devices were both predictive of hip fracture risk, whereas the phalanges QUS device was not.
Resumo:
The present clinical study investigated the outcome of intentional replantation using resection of the ankylosed sites of the root, extraoral endodontic treatment using titanium posts and Emdogain for periodontal healing following trauma-related ankylosis. During an evaluation period of 6 years, 16 ankylosed teeth affected by replacement resorption were treated as described. Evaluation parameters before treatment and during the follow-up period included Periotest scores, percussion sound and periapical radiographs. All findings were compared to those of the adjacent teeth. In a second accident, one tooth was lost after 7 months and was excluded as a dropout. Ankylosis did not recur in seven replanted teeth, which were observed for an average of 52.3 months (range: 24-68 months). Ankylosis recurred in eight teeth after an average period of 12 months (range: 4-26 months). An infraocclusion, normal or only slightly reduced Periotest scores and normal percussion sound were preoperatively found in six of seven successfully replanted teeth, which corresponded to a relatively small area of ankylosis. The majority of the teeth showing recurrent ankylosis preoperatively presented with normal position, negative Periotest scores and a high percussion sound which corresponded to an extended area of ankylosis. Statistically significant relationship between preoperative findings and the treatment outcome (P = 0.031) have become apparent. The results indicate that the treatment of minor areas of ankylosis by intentional replantation, resection of the ankylosed sites and Emdogain appeared to prevent or delay the recurrence of ankylosis in 7 of 15 teeth.