984 resultados para high-field ferromagnetic resonance
Resumo:
The objective of this work was to evaluate the effects of high density planting on 'Tommy Atkins' mango trees cultivated in subhumid warm tropical climate in northeastern Brazil. Treatments consisted of five spacial arrangements of plants (8x5 m, 7x4 m, 6x3 m, 5x2 m and 4x2 m), which resulted in the following plant densities: 250 (control), 357, 555, 1,000 and 1,250 plants per hectare. Plant vegetative and reproductive variables, besides fruit quality parameters, were evaluated at seven and eight years after transplantation to the field. In general, high density planting caused reduction in vegetative and reproductive variables of individual mango trees, but had little influence on fruit quality. Above 555 plants per hectare, a significant decrease was observed in mango tree growth. Furthermore, there were decreases in the percentage of flowering, fruit yield per plant and per area. However, planting density up to 357 plants per hectare, in spite of decreasing plant growth and fruit yield per tree, increases fruit yield per area in 30% in comparison to the control.
Resumo:
Contemporary coronary magnetic resonance angiography techniques suffer from signal-to-noise ratio (SNR) constraints. We propose a method to enhance SNR in gradient echo coronary magnetic resonance angiography by using sensitivity encoding (SENSE). While the use of sensitivity encoding to improve SNR seems counterintuitive, it can be exploited by reducing the number of radiofrequency excitations during the acquisition window while lowering the signal readout bandwidth, therefore improving the radiofrequency receive to radiofrequency transmit duty cycle. Under certain conditions, this leads to improved SNR. The use of sensitivity encoding for improved SNR in three-dimensional coronary magnetic resonance angiography is investigated using numerical simulations and an in vitro and an in vivo study. A maximum 55% SNR enhancement for coronary magnetic resonance angiography was found both in vitro and in vivo, which is well consistent with the numerical simulations. This method is most suitable for spoiled gradient echo coronary magnetic resonance angiography in which a high temporal and spatial resolution is required.
Resumo:
The objective of this work was to evaluate sampling density on the prediction accuracy of soil orders, with high spatial resolution, in a viticultural zone of Serra Gaúcha, Southern Brazil. A digital elevation model (DEM), a cartographic base, a conventional soil map, and the Idrisi software were used. Seven predictor variables were calculated and read along with soil classes in randomly distributed points, with sampling densities of 0.5, 1, 1.5, 2, and 4 points per hectare. Data were used to train a decision tree (Gini) and three artificial neural networks: adaptive resonance theory, fuzzy ARTMap; self‑organizing map, SOM; and multi‑layer perceptron, MLP. Estimated maps were compared with the conventional soil map to calculate omission and commission errors, overall accuracy, and quantity and allocation disagreement. The decision tree was less sensitive to sampling density and had the highest accuracy and consistence. The SOM was the less sensitive and most consistent network. The MLP had a critical minimum and showed high inconsistency, whereas fuzzy ARTMap was more sensitive and less accurate. Results indicate that sampling densities used in conventional soil surveys can serve as a reference to predict soil orders in Serra Gaúcha.
Resumo:
A new fast MR-venography approach using a high resolution True-FISP imaging sequence was investigated in 20 patients suffering from 23 deep vein thromboses. Diagnosis was proven by x-ray venography, CT or ultrasound examination. The presented technique allowed for clear thrombus visualization with a high contrast to the surrounding blood pool even in calf veins. Acquisition time was less than 10 minutes for imaging the pelvis and the legs. No contrast media was needed. The presented high resolution True-FISP MR-venography is a promising non-invasive, fast MR-venography approach for detection of deep venous thrombosis.
Resumo:
Centrifugal compressors are widely used for example in process industry, oil and gas industry, in small gas turbines and turbochargers. In order to achieve lower consumption of energy and operation costs the efficiency of the compressor needs to be improve. In the present work different pinches and low solidity vaned diffusers were utilized in order to improve the efficiency of a medium size centrifugal compressor. In this study, pinch means the decrement of the diffuser flow passage height. First different geometries were analyzed using computational fluid dynamics. The flow solver Finflo was used to solve the flow field. Finflo is a Navier-Stokes solver. The solver is capable to solve compressible, incompressible, steady and unsteady flow fields. Chien's k-e turbulence model was used. One of the numerically investigated pinched diffuser and one low solidity vaned diffuser were studied experimentally. The overall performance of the compressor and the static pressure distribution before and after the diffuser were measured. The flow entering and leaving the diffuser was measured using a three-hole Cobra-probe and Kiel-probes. The pinch and the low solidity vaned diffuser increased the efficiency of the compressor. Highest isentropic efficiency increment obtained was 3\% of the design isentropic efficiency of the original geometry. It was noticed in the numerical results that the pinch made to the hub and the shroud wall was most beneficial to the operation of the compressor. Also the pinch made to the hub was better than the pinchmade to the shroud. The pinch did not affect the operation range of the compressor, but the low solidity vaned diffuser slightly decreased the operation range.The unsteady phenomena in the vaneless diffuser were studied experimentally andnumerically. The unsteady static pressure was measured at the diffuser inlet and outlet, and time-accurate numerical simulation was conducted. The unsteady static pressure showed that most of the pressure variations lay at the passing frequency of every second blade. The pressure variations did not vanish in the diffuser and were visible at the diffuser outlet. However, the amplitude of the pressure variations decreased in the diffuser. The time-accurate calculations showed quite a good agreement with the measured data. Agreement was very good at the design operation point, even though the computational grid was not dense enough inthe volute and in the exit cone. The time-accurate calculation over-predicted the amplitude of the pressure variations at high flow.
Resumo:
rejection can lead to loss of function. Histological reading of endomyocardial biopsy remains the "gold standard" for guiding immunosuppression, despite its methodological limitations (sampling error and interobserver variability). The measurement of the T2 relaxation time has been suggested for detection of allograft rejection, on the pathophysiological basis that the T2 relaxation time prolongs with local edema resulting from acute allograft rejection. Using breath-held cardiac magnetic resonance T2 mapping at 1.5 T, Usman et al. (CircCardiovascImaging2012) detected moderate allograft rejection (grade 2R, ISHLT 2004). With modern immunosuppression grade 2R rejection has become a rare event, but the need remains for a technique that permits the discrimination of absent (grade 0R) and mild rejection (grade 1R). We therefore investigated whether an increase of magnetic field strength to 3T and the use of real-time navigator-gated respiration compensation allow for an increase in the sensitivity of T2 relaxation time detection that is necessary to achieve this discrimination. Methods: Eighteen patients received EMB (Tan et al., ArchPatholLabMed2007) and cardiac T2 mapping on the same day. Reading of T2 maps was blinded to the histological results. For final analysis, 3 cases with known 2R rejection at the time of T2 mapping were added, yielding 21 T2 mapping sessions. A respiration-navigator-gated radial gradient-recalled-echo pulse sequence (resolution 1.17 mm2, matrix 2562, trigger time 3 heartbeats, T2 preparation duration TET2 Prep = 60/30/0 ms) was applied to obtain 3 short-axis T2 maps (van Heeswijk et al., JACCCardiovascImaging2012), which were segmented according to AHA guidelines (Cerqueira et al, Circulation2001). The highest segmental T2 values were grouped according to histological rejection grade and differences were analyzed by Student's t-test, except for the non-blinded cases with 2R rejection. The degree of discrimination was determined using the Spearman's ranked correlation test. Results: The high-quality T2 maps allowed for visual differentiation of the rejection degrees (Figure 1), and the correlation of T2 mapping with the histological grade of acute cellular rejection was significant (Spearman's r = 0.56, p = 0.007). The 0R (n = 15) and 1R (n = 3) degrees demonstrated significantly different T2 values (46.9 ± 5.0 and 54.3 ± 3.0 ms, p = 0.02, Figure 2). Cases with 2R rejection showed clear T2 elevation (T2 = 60.3 ± 16.2 ms). Conclusions: This pilot study demonstrates that non-invasive free-breathing cardiac T2 mapping at 3T discriminates between no and mild cardiac allograft rejection. Confirmation of these encouraging results in a larger cohort should consider a study able to show equivalency or superiority of T2 mapping.
Resumo:
Phage display is a powerful method of isolating of antibody fragments from highly diverse naive human antibody repertoires. However, the affinity of the selected antibodies is usually low and current methods of affinity maturation are complex and time-consuming. In this paper, we describe an easy way to increase the functional affinity (avidity) of single chain variable fragments (scFvs) by tetramerization on streptavidin, following their site-specific biotinylation by the enzyme BirA. Expression vectors have been constructed that enable addition of the 15 amino acid biotin acceptor domain (BAD) on selected scFvs. Different domains were cloned at the C-terminus of scFv in the following order: a semi-rigid hinge region (of 16 residues), the BAD, and a histidine tail. Two such recombinant scFvs directed against the carcinoembryonic antigen (CEA) were previously selected from human non-immune and murine immune phage display libraries. The scFvs were first synthesized in Escherichia coli carrying the plasmid encoding the BirA enzyme, and then purified from the cytoplasmic extracts by Ni-NTA affinity chromatography. Purified biotinylated scFvs were tetramerized on the streptavidin molecule to create a streptabody (StAb). The avidity of various forms of anti-CEA StAbs, tested on purified CEA by competitive assays and surface plasmon resonance showed an increase of more than one log, as compared with the scFv monomer counterparts. Furthermore, the percentage of direct binding of 125I-labeled StAb or monomeric scFv on CEA-Sepharose beads and on CEA-expressing cells showed a dramatic increase for the tetramerized scFv (>80%), as compared with the monomeric scFv (<20%). Interestingly, the percentage binding of 125I-labeled anti-CEA StAbs to CEA-expressing colon carcinoma cells was definitely higher (>80%) than that obtained with a reference high affinity murine anti-CEA mAb (30%). Another advantage of using scFvs in a StAb format was demonstrated by Western blot analysis, where tetramerized anti-CEA scFv could detect a small quantity of CEA at a concentration 100-fold lower than the monomeric scFv.
Resumo:
In vivo fetal magnetic resonance imaging provides aunique approach for the study of early human braindevelopment [1]. In utero cerebral morphometry couldpotentially be used as a marker of the cerebralmaturation and help to distinguish between normal andabnormal development in ambiguous situations. However,this quantitative approach is a major challenge becauseof the movement of the fetus inside the amniotic cavity,the poor spatial resolution provided by very fast MRIsequences and the partial volume effect. Extensiveefforts are made to deal with the reconstruction ofhigh-resolution 3D fetal volumes based on severalacquisitions with lower resolution [2,3,4]. Frameworkswere developed for the segmentation of specific regionsof the fetal brain such as posterior fossa, brainstem orgerminal matrix [5,6], or for the entire brain tissue[7,8], applying the Expectation-Maximization MarkovRandom Field (EM-MRF) framework. However, many of theseprevious works focused on the young fetus (i.e. before 24weeks) and use anatomical atlas priors to segment thedifferent tissue or regions. As most of the gyraldevelopment takes place after the 24th week, acomprehensive and clinically meaningful study of thefetal brain should not dismiss the third trimester ofgestation. To cope with the rapidly changing appearanceof the developing brain, some authors proposed a dynamicatlas [8]. To our opinion, this approach however faces arisk of circularity: each brain will be analyzed /deformed using the template of its biological age,potentially biasing the effective developmental delay.Here, we expand our previous work [9] to proposepost-processing pipeline without prior that allow acomprehensive set of morphometric measurement devoted toclinical application. Data set & Methods: Prenatal MRimaging was performed with a 1-T system (GE MedicalSystems, Milwaukee) using single shot fast spin echo(ssFSE) sequences (TR 7000 ms, TE 180 ms, FOV 40 x 40 cm,slice thickness 5.4mm, in plane spatial resolution1.09mm). For each fetus, 6 axial volumes shifted by 1 mmwere acquired under motherâeuro?s sedation (about 1min pervolume). First, each volume is segmentedsemi-automatically using region-growing algorithms toextract fetal brain from surrounding maternal tissues.Inhomogeneity intensity correction [10] and linearintensity normalization are then performed. Brain tissues(CSF, GM and WM) are then segmented based on thelow-resolution volumes as presented in [9]. Ahigh-resolution image with isotropic voxel size of 1.09mm is created as proposed in [2] and using B-splines forthe scattered data interpolation [11]. Basal gangliasegmentation is performed using a levet setimplementation on the high-resolution volume [12]. Theresulting white matter image is then binarized and givenas an input in FreeSurfer software(http://surfer.nmr.mgh.harvard.edu) to providetopologically accurate three-dimensional reconstructionsof the fetal brain according to the local intensitygradient. References: [1] Guibaud, Prenatal Diagnosis29(4) (2009). [2] Rousseau, Acad. Rad. 13(9), 2006. [3]Jiang, IEEE TMI 2007. [4] Warfield IADB, MICCAI 2009. [5]Claude, IEEE Trans. Bio. Eng. 51(4) 2004. [6] Habas,MICCAI 2008. [7] Bertelsen, ISMRM 2009. [8] Habas,Neuroimage 53(2) 2010. [9] Bach Cuadra, IADB, MICCAI2009. [10] Styner, IEEE TMI 19(39 (2000). [11] Lee, IEEETrans. Visual. And Comp. Graph. 3(3), 1997. [12] BachCuadra, ISMRM 2010.
Resumo:
Tässä työssä on esitetty väsyttävän kuormituksen mittaamiseen ja mittausdatan jälkikäsittelyyn sekä väsymismitoitukseen liittyviä menetelmiä. Menetelmien sovelluskohteena oli metsäkoneen kuormain, joka on väsyttävästi kuormitettu hitsattu rakenne. Teoriaosassa on kuvattu väsymisilmiötä ja väsymismitoitusmenetelmiä sekä kuormitusten tunnistamiseen ja mittausten jälkikäsittelyyn liittyviä menetelmiä. Yleisimmin käytettyjen väsymismitoitusmenetelmien rinnalle on esitetty luotettavuuteen perustuvaa väsymismitoitusmenetelmää. Kuormainten suunnittelussa on keveys- j a kestoikävaatimusten takia erityisen suuri merkitys väsymisen huomioimisella. Rakenteille on ominaista tietyt toiminnan kannalta välttämättömät hitsatut yksityiskohdat, jotka usein määräävät koko rakenteen kestoiän. Koska nämä ongelmakohdat pystytään useimmiten tunnistamaan jo suunnitteluvaiheessa, voidaan yksityiskohtien muotoilulla usein parantaa huomattavasti koko rakenteen kestoikää. Näiden yksityiskohtien optimointi on osittain mahdollista toteuttaa ilman kuormituskertymätietoa, mutta useimmiten kuormitusten tunnistaminen on edellytys parhaan ratkaisun löytymiselle. Tällöin toistaiseksi paras keino todellisen väsyttävän kuormituksen tunnistamiseksi on pitkäaikaiset kenttämittaukset. Kenttämittauksilla selvitetään rakenteeseen kohdistuvat kuormitukset venymäliuskojen avulla. Kuormitusten tunnistamisella on erityisen suuri merkitys kun halutaan määrittää rakenteen kestoikä. Väsyminen ja väsyttävä kuormitus ovat kuitenkin tilastollisia muuttujia j a yksittäiselle rakenteelle ei ole mahdollista määrittää tarkkaa k estoikää. Tilastollisia menetelmiä käyttäen on kuitenkin mahdollista määrittää rakenteen vaurioitumisriski. Laskettaessa vaurioitumisriskiä suurelle määrälle yksittäisiä rakenteita voidaan muodostaa tarkkojakin ennusteita mahdollisten vaurioiden lukumäärästä. Tällöin kuormituskertymätiedosta voi olla tavanomaisen suunnittelun lisäksi laajempaa hyötyä esimerkiksi takuukäsittelyssä. Tässä työssä on sovellettu esitettyjä teorioita käytännössä metsäkoneen harvesterin puomiston väsymistarkasteluun. Kyseisen rakenteen kuormituksia mitattiin kahden viikon aikana yhteensä 35 tuntia, jonka perusteella laskettiin väsyttävän kuormituksen tilastollinen jakauma esimerkkitapaukselle. Mittauksen perusteella ei voitu tehdä kuitenkaan johtopäätöksiä tuotteen koko elinkaaren kuormituksista eikä muiden samanlaisten tuotteiden kuormituksista, koska mitattu otos oli suhteellisen lyhyt ja rajoittui vain yhteen käyttäjään ja muutamaan käyttökohteeseen. Menetelmien testaamiseksi kyseinen otos oli kuitenkin riittävä. Kuormituskertymätietoa käytettiin hyväksi myös laatumääritysten muodostamisessaesimerkkitapaukselle. Murtumismekaniikkaan perustuvalla menetelmällä arvioitiinharvesteripilarin valun mahdollisten valuvirheiden suurin sallittu koko. Luotettavuuteen pohjautuvan mitoitusmenettelyn tarve näyttää olevanlisääntymässä, joten pitkäaikaisten kenttämittausten tehokas hyödyntäminen tulee olemaan keskeinen osa väsymismitoitusta lähitulevaisuudessa. Menetelmiä olisi mahdollista tehostaa yhdistämällä kuormituskertymään erilaisia kuormitusten suhteen riippuvia tunnettuja suureita kuten käsiteltävän puun halkaisija. Todellisettuotekohtaiset tilastolliset jakaumat kuormituksista voitaisiin muodostaa mahdollisesti tehokkaammin, jos esimerkiksi kuormitusten riippuvuus metsätyypistä pystyttäisiin ensin määrittämään.
Resumo:
Aktiivisten magneettilaakereiden avulla on mahdollista kannatella ferromagneettisia kappaleita, kuten sähkökoneiden roottoreita, ilman fyysistä kontaktia. Magneettilaakerit tarjoavat monia etuja, kuten esimerkiksi kitkattomuuden, verrattuina perinteisiin mekaanisiin laakereihin. Nämä edut vielä korostuvat suurnopeuskäytöissä, jotka ovat magneettilaakereiden pääasiallisia käyttökohteita. Tässä työssä esitellään magneettilaakereihin liittyvät erusteoriat ja niiden sovellustavat. Tämän jälkeen tarkastellaanmagneettilaakereiden kanssa käytettäviä säätöratkaisuja ja esitetään niille soveltuvat viritysmenetelmät. Teorioiden pohjalta rakennetaan täydellinen magneettilaakerijärjestelmän simulointimalli säätöratkaisuineen ja suoritetaan järjestelmän toimintaa kuvaavia simulointeja. Simuloinneissa saadut tulokset pyritään vielä varmentamaan suorittamalla mittauksia koelaitteistolla ja vertaamalla saatuja tuloksia keskenään.
Resumo:
To study the role of early energetic abnormalities in the subsequent development of heart failure, we performed serial in vivo combined magnetic resonance imaging (MRI) and (31)P magnetic resonance spectroscopy (MRS) studies in mice that underwent pressure-overload following transverse aorta constriction (TAC). After 3 wk of TAC, a significant increase in left ventricular (LV) mass (74 +/- 4 vs. 140 +/- 26 mg, control vs. TAC, respectively; P < 0.000005), size [end-diastolic volume (EDV): 48 +/- 3 vs. 61 +/- 8 microl; P < 0.005], and contractile dysfunction [ejection fraction (EF): 62 +/- 4 vs. 38 +/- 10%; P < 0.000005] was observed, as well as depressed cardiac energetics (PCr/ATP: 2.0 +/- 0.1 vs. 1.3 +/- 0.4, P < 0.0005) measured by combined MRI/MRS. After an additional 3 wk, LV mass (140 +/- 26 vs. 167 +/- 36 mg; P < 0.01) and cavity size (EDV: 61 +/- 8 vs. 76 +/- 8 microl; P < 0.001) increased further, but there was no additional decline in PCr/ATP or EF. Cardiac PCr/ATP correlated inversely with end-systolic volume and directly with EF at 6 wk but not at 3 wk, suggesting a role of sustained energetic abnormalities in evolving chamber dysfunction and remodeling. Indeed, reduced cardiac PCr/ATP observed at 3 wk strongly correlated with changes in EDV that developed over the ensuing 3 wk. These data suggest that abnormal energetics due to pressure overload predict subsequent LV remodeling and dysfunction.
Resumo:
Thanks to the continuous progress made in recent years, medical imaging has become an important tool in the diagnosis of various pathologies. In particular, magnetic resonance imaging (MRI) permits to obtain images with a remarkably high resolution without the use of ionizing radiation and is consequently widely applied for a broad range of conditions in all parts of the body. Contrast agents are used in MRI to improve tissue discrimination. Different categories of contrast agents are clinically available, the most widely used being gadolinium chelates. One can distinguish between extracellular gadolinium chelates such as Gd-DTPA, and hepatobiliary gadolinium chelates such as Gd-BOPTA. The latter are able to enter hepatocytes from where they are partially excreted into the bile to an extent dependent on the contrast agent and animal species. Due to this property, hepatobiliary contrast agents are particularly interesting for the MRI of the liver. Actually, a change in signal intensity can result from a change in transport functions signaling the presence of impaired hepatocytes, e.g. in the case of focal (like cancer) or diffuse (like cirrhosis) liver diseases. Although the excretion mechanism into the bile is well known, the uptake mechanisms of hepatobiliary contrast agents into hepatocytes are still not completely understood and several hypotheses have been proposed. As a good knowledge of these transport mechanisms is required to allow an efficient diagnosis by MRI of the functional state of the liver, more fundamental research is needed and an efficient MRI compatible in vitro model would be an asset. So far, most data concerning these transport mechanisms have been obtained by MRI with in vivo models or by a method of detection other than MRI with cellular or sub-cellular models. Actually, no in vitro model is currently available for the study and quantification of contrast agents by MRI notably because high cellular densities are needed to allow detection, and no metallic devices can be used inside the magnet room, which is incompatible with most tissue or cell cultures that require controlled temperature and oxygenation. The aim of this thesis is thus to develop an MRI compatible in vitro cellular model to study the transport of hepatobiliary contrast agents, in particular Gd-BOPTA, into hepatocytes directly by MRI. A better understanding of this transport and especially of its modification in case of hepatic disorder could permit in a second step to extrapolate this knowledge to humans and to use the kinetics of hepatobiliary contrast agents as a tool for the diagnosis of hepatic diseases.
Resumo:
The purpose of this dissertation is to increase the understanding and knowledge of field sales management control systems (i.e. sales managers monitoring, directing, evaluating and rewarding activities) and their potential consequences on salespeople. This topic is important because research conducted in the past has indicated that the choice of control system type can on the other hand have desirable consequences, such as high levels of motivation and performance, and on the other hand leadto harmful unintended consequences, such as opportunistic or unethical behaviors. Despite the fact that marketing and sales management control systems have been under rigorous research for over two decades, it still is at a very early stage of development, and several inconsistencies can be found in the research results. This dissertation argues that these inconsistencies are mainly derived from misspecification of the level of analysis in the past research. These different levels of analysis (i.e. strategic, tactical, and operational levels) involve very different decision-making situations regarding the control and motivation of sales force, which should be taken into consideration when conceptualizing the control. Moreover, the study of salesperson consequences of a field sales management control system is actually a cross-level phenomenon, which means that at least two levels of analysis are simultaneously involved. The results of this dissertation confirm the need to re-conceptualize the field sales management control system concept. It provides empirical evidence for the assertion that control should be conceptualized with more details atthe tactical/operational level of analysis than at the strategic levelof analysis. Moreover, the results show that some controls are more efficiently communicated to field salespeople than others. It is proposed that this difference is due to different purposes of control; some controls aredesigned for influencing salespersons' behavior (aim at motivating) whereas some controls are designed to aid decision-making (aim at providing information). According to the empirical results of this dissertation, the both types of controls have an impact to the sales force, but this impactis not as strong as expected. The results obtained in this dissertation shed some light to the nature of field sales management control systems, and their consequences on salespeopl
Resumo:
The solid-rotor induction motor provides a mechanically and thermally reliable solution for demanding environments where other rotor solutions are prohibited or questionable. Solid rotors, which are manufactured of single pieces of ferromagnetic material, are commonly used in motors in which the rotationspeeds exceed substantially the conventional speeds of laminated rotors with squirrel-cage. During the operation of a solid-rotor electrical machine, the rotor core forms a conductor for both the magnetic flux and the electrical current. This causes an increase in the rotor resistance and rotor leakage inductance, which essentially decreases the power factor and the efficiency of the machine. The electromagnetic problems related to the solid-rotor induction motor are mostly associated with the low performance of the rotor. Therefore, the main emphasis in this thesis is put on the solid steel rotor designs. The rotor designs studied in thisthesis are based on the fact that the rotor construction should be extremely robust and reliable to withstand the high mechanical stresses caused by the rotational velocity of the rotor. In addition, the demanding operation environment sets requirements for the applied materials because of the high temperatures and oxidizing acids, which may be present in the cooling fluid. Therefore, the solid rotors analyzed in this thesis are made of a single piece of ferromagnetic material without any additional parts, such as copper end-rings or a squirrel-cage. A pure solid rotor construction is rigid and able to keep its balance over a large speed range. It also may tolerate other environmental stresses such as corroding substances or abrasive particles. In this thesis, the main target is to improve the performance of an induction motor equipped with a solid steel rotor by traditional methods: by axial slitting of the rotor, by selecting a proper rotor core material and by coating the rotor with a high-resistive stainless ferromagnetic material. In the solid steel rotor calculation, the rotor end-effects have a significant effect on the rotor characteristics. Thus, the emphasis is also put on the comparison of different rotor endfactors. In addition, a corrective slip-dependent end-factor is proposed. The rotor designs covered in this thesis are the smooth solid rotor, the axially slitted solid rotor and the slitted rotor having a uniform ferromagnetic coating cylinder. The thesis aims at design rules for multi-megawatt machines. Typically, mega-watt-size solidrotor machines find their applications mainly in the field of electric-motor-gas-compression systems, in steam-turbine applications, and in various types of largepower pump applications, where high operational speeds are required. In this thesis, a 120 kW, 10 000 rpm solid-rotor induction motor is usedas a small-scale model for such megawatt-range solid-rotor machines. The performance of the 120 kW solid-rotor induction motors is determined by experimental measurements and finite element calculations.