929 resultados para high speed optical switch


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The objective of this study was to evaluate the displacement of petroleum/diesel solutions, at different concentrations, observing the effect of ultrasonic vibrations in fluids present in porous media to obtain an increase in oil production. The bubbles produced by ultrasound implode asymmetrically in the rock, generating liquid jets with high speed, displacing the oil present in porous media. The oil/diesel solutions were prepared with concentrations ranging from 20 g/L to 720 g/L in oil in relation to diesel and its viscosities were obtained in a Brookfield Rheometer RS2000, with temperature ranging from 25 to 55 °C. After, calculations were performed to obtain the activation energy data for oil/diesel solutions. For oil recovery experiments, cylindrical samples of porous rock (core samples), with resin around the perimeter and its two circular bases free to allow the passage of fluids, were first saturated with 2% KCl solution and after with oil solutions. The results of oil extraction were satisfactory for all studied solutions, being obtained up to 68% partial displacement with saline solution injection. The ultrasound system was used after saline injection, increasing oil displacement, with oil extractions ranging from 63% to 79%. During the experiments, it was observed the warming of core samples, helping to reduce the viscosity of more concentrated systems, and consequently enhancing the percentage of advanced recovery for all studied solutions

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A new acylated flavonoid, 6,4'-dimethoxyquereetin-3-O-beta-D-6 ''[3,4,5-trihydroxy (E)-cinnamoyl]glucopyranoside, and a naphthopyranone dimer, named eriocauline, together with 2 other known flavonoids, 6-methoxyapigenin-7-O-beta-D-glucopyranoside and 6-methoxyapigenin-7-O-beta-D-allopyranoside, have been isolated from the capitulae of Eriocaulon ligulatum. The compounds were identified using spectroscopic methods (HR-ESI-MS, and 1-D and 2-D NMR). The methanol extract exhibited mutagenic activity in the Salmonella/microsome assay, in strains TA100, TA97a and TA102 and for dichloromethane extract tested in strain TA98.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Oral and facial bone defects can undertake appearance, psychosocial well-being and stomathognatic function of its patients. Over the yerars several strategies for bone defect regeneration have arised to treat these pathologies, among them the use of frozen and irradiated bone allograft. Manipulation of bone grafts it s not determined yet, and several osteotomy alternatives can be observed. The present work evaluated with a microscope the bone fragments obtained from different osteotomy methods and irrigation on rings and blocks allografts irradiated and frozen at 80° negative in a rabbit model. The study is experimental in vitro and it sample was an adult male New Zealand rabbit. The animal was sacrificed to obtain long bones, that were submitted to freezing at 80º negative and irradiated with Cobalt- 60. Then the long bones were sectioned into 24 bone pieces, divided into 4 groups: G1 (n=06) osteotomy was performed with bur No. 6 forming rings with 5 mm thickness with high-speed handpiece with manual irrigation; G2 (n=06) osteotomy was performed with bur No. 6 forming rings with 5 mm thick with surgical motor with a manual irrigation rotation 1500 rpm; GA (n=06), osteotomy with trephine using manual irrigation with saline; and GB (n=06), osteotomy with trephine using saline from peristaltic pumps of surgical motor. Five bone pieces of each group were prepared for analysis on light microscopy (LM) and one on electronic scan electronic microscopy (SEM). On the SEM analysis edges surface, presence of microcracks and Smear Layer were evaluated. Analyzing osteotomy technics on SEM was observed: increased presence of microcracks cutting with high speed; increased presence of areas covered by Smear Layer when cutting with motor implant. The irrigation analysis with SEM was observed: that the presence of microcracks does not depend on the type of irrigation; on manual irrigation, there was greater discrepancy between the cutting lines. The descriptive analysis of the osteotomy and irrigation process on LM showed: histological analysis showing the bony margins with clear tissue changed layer, composed of blackened tissue of charred appearance near to the cortical bone; on the edges of the bony part, bone fragments that were displaced during the bone cut and bone irregularities were observed. After analysis of results we can conclude: that there was greater regularity of the bone cut using high-speed handpiece than using motor implant; the cut with trephine using saline irrigated from peristaltic pumps of surgical motor showed greater homogeneity when compared with manual irrigation; charred tissue was found in all obtained bone samples, whit no significant statistically difference on the proportion of carbonization of the two analysed technics

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The rationalization of work in the Dentistry has been taking the professional to work for ways and systems based in the ergonomics, turning their work efficient and less tiring. Since their academic formation, the dentists surgeons are concerned with the high productivity in clinic and with the final result of the work, neglecting the way as it is executed, which reduce their work capacity and exhibits them to occupational diseases that could be minimized and/or forewarned. This research had as the main objective to investigate the knowledge of the Dentistry academics of Rio Grande do Norte Federal University concerning the Noise-induced Hearing Loss (NIHL), relating them at the noise levels that they are exposed, as well as to the preventive measures taken during the clinical activities. Was observed that 95% of the individuals know that the dentist surgeon is a professional in risk for NIHL. Among the causes of NIHL, the one that obtained the largest frequency citation was the high-speed handpieces, reminded by 92,4% of the academics. Among the students which enumerated protective measures for NIHL, 92% mentioned the use of the ear plugs, although 97% of the researched have told do not use any kind of preventive measure related to the noise. Was also observed that 96% of the academics notice the noise during the clinical attendance, what inconvenience 28,1% of them. Related the noise levels, the high-speed handpieces of the academics presented a medium value of 80,5 dB varying from 72,3 to 88,3 dB. The average of the ambient noise observed at the Integrated Clinic was about 74,8 dB. In spite of the noise levels in this research were observed below the established limits of tolerance by the legislation, they can provoke damages to the Dentistry professionals' health, or that suggests the need of an intervention and use of immediate preventive measures able to generate a healthy atmosphere of work and less risky

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Com o grande crescimento tecnológico e a necessidade de melhoria, um dos materiais que ganhou uma grande gama na área da engenharia mecânica é a cerâmica, pois possui vantagens físico-químicas e propriedades mecânicas significativas sobre o aço. Entretanto, sua usinagem é um processo difícil e delicado, que requer ainda uma grande atenção em relação ao seu estudo. Assim, o processo de retificação é um dos métodos que tem apresentado bons resultados, porém um grande problema acerca de tal processo é o uso excessivo de fluidos de corte, o que se tornou uma preocupação mundial, já que os fluidos apresentam graves problemas socioambientais, além disso, o fluido de corte é responsável por uma grande parte do custo final do processo, provocando, desse modo, um grande interesse em pesquisas referentes a métodos alternativos de forma a reduzir o consumo e melhorar as características do fluido de corte utilizado. Este trabalho visa comparar duas técnicas de lubri-refrigeração, o método convencional e a Lubrificação Otimizada. O uso do método otimizado é uma alternativa à diminuição do volume de fluido utilizado, já que este tem como princípio a aplicação de uma menor quantidade de fluido de corte com uma alta velocidade, localmente aplicada, ou seja, com essa redução benefícios ambientais e socioeconômicas são obtidos. A análise do trabalho será feita a partir da avaliação das variáveis de saída do processo de retificação plana tais como o comportamento rugosidade e desgaste do rebolo, já que por elas é possível avaliar o processo em relação a qualidade da peça versus custo. Com essas analises, pretende-se avaliar se a técnica otimizada é viável a substituição da refrigeração convencional na retificação plana de cerâmicas.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This work analyses the waveshapes of continuing currents and parameters of M-components in positive cloud-to-ground (CG) flashes through high-speed GPS synchronized videos. The dataset is composed of only long continuing currents (with duration longer than 40 ms) and was selected from more than 800 flashes recorded in Sao Jose dos Campos (45.864 degrees W, 23.215 degrees S) and Uruguaiana (29.806 degrees W, 57.005 degrees S) in Southeast and South of Brazil, respectively, during 2003 to 2007 summers. The videos are compared with data obtained by the Brazilian Lightning Location System (BrasilDAT) in order to determine the polarity of each flash and select only positive cases. There are only two studies of waveshapes of continuing currents in the literature. One is based on direct current measurements of triggered lightning, in which four different types of waveshapes were observed; and the other is based on measurements of luminosity variations in high-speed videos of CG negative lightning, in which besides the four types above mentioned two additional types were observed. The present work is an extension of the latter, using the same method but now applied to obtain the waveshapes of positive CG lightning. As far as the authors know, this is the first report on M-components in positive continuing currents. We also have used the luminosity-versus-time graphs to observe their occurrence and measure some parameters (duration, elapsed time and time between two successive M-components), whose statistics are presented and compared in detail to the data for negative flashes. We have plotted a histogram of the M-components elapsed time over the total duration of the continuing current for positive flashes, which presented an exponential decay (correlation coefficient: 0.83), similar to what has been observed for negative flashes. (C) 2008 Elsevier B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Several works characterize the presence of spinner dolphins at Fernando de Noronha Archipelago in the Dolphins Bay. Though, the dolphins abidance inside this cove has decreased and a new area has been occupied by the animals to achieve the same behaviors, that are resting, breeding and nursing. This area comprises the Inside Sea northeast border of Fernando s de Noronha Island, including the opposing Middle and Dog shore area, the San Antonio Bay and the Between Islands region. The aim was to characterize the dolphins occupation and describe their interactions with the tourism in this area. Data were collected in 2008 and 2009 through a fixed point observation. The study area was divided into seven sub-areas, recording: presence/absence of dolphins, days abidance endurance, abidance length in each area, estimated number of individuals, dolphins direction and speed of displacement, boats presence, interaction period, monitoring, boats attitude and velocity. The dolphins abidance time displayed the same pattern during both years of study, with the higher occupancy in the Between Islands region. Groups with farther than 200 individuals were more frequent both 2008 (46.2%) and 2009 (42.3%). Thus the displacement s slow speed as the preferred direction towards Rat Island also showed the same pattern in both years. The Between Islands region also presented the boats major abidance near the dolphins groups. Boats moved farther in slow speed (95%) than at high speed (5%). The legislation s compliance for the cetaceans protection occurred in 89.7% of 2.839 interactions between boats and spinners, in which this variable was recorded. Whenever boats moved at a slow speed during the meetings with spinner dolphins groups, animals also moved at a slow speed (n = 337), significantly more than the fast displacements (n = 128) ix or "porpoise" (n = 4) (X2 = 318.543, p = -0.001). When boats quickly passed by groups, a significant difference between the dolphins displacement speeds was observed (X2 = 18.264, p =- 0.001), however, the slow (47%) and fast (47% ) displacements frequency was equal, noted the difference with the porpoise displacements (6%), which had the lowest frequency. Data indicate the establishment of a new occupation pattern of the spinner dolphins at Fernando de Noronha, with the Between Islands area being of great importance to the dolphins habits and currently the main area of the boats meeting with the dolphins, showing the need of new conservation measures in this area

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Diamond-like carbon (DLC) films were obtained by spinning a tungsten carbide substrate at a high speed using an oxyacetylene flame. The films deposited at a typical experimental condition of substrate temperature of 810 degrees C, rotation of 600 rpm and 3 h deposition time, exhibited an uniform, very smooth, hard and glassy surface covering the entire exposed face of the substrate. These films were identified as DLC by their characteristic broad Raman spectra centered at 1554 cm(-1) and micro-Vicker's hardness > 3400 kg mm(-2). For substrate temperatures < 800 degrees C the film started losing the uniform glassy surface and the hardness deteriorated. For temperatures > 950 degrees C the film was still hard and shiny, but black in color. DLC films were also obtained in a wide range of speeds of rotation (300-750 rpm), as long as the temperature remained close to 850 degrees C. (C) 1999 Elsevier B.V. S.A. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Avaliaram-se as alterações do pH, da P O2 e da P CO2 do sangue arterial e da concentração de lactato sangüíneo de 11 cavalos adultos da raça Árabe, submetidos a exercício progressivo em esteira de alta velocidade. Antes do exercício, no intervalo dos 15 segundos finais de cada mudança de velocidade e aos 1, 3 e 5 minutos após o término do exercício foram coletadas amostras de sangue arterial e venoso para a mensuração dos gases sangüíneos e da concentração de lactato. O exercício resultou em diminuição do pH, da pressão parcial de O2 (P O2) e da pressão parcial de CO2 (P CO2). A concentração de lactato sangüíneo elevou-se exponencialmente a partir da velocidade de 8,0m/s até os momentos após término do exercício.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

INTRODUÇÃO: a preservação da estrutura de esmalte após a remoção dos acessórios ortodônticos é obrigação do clínico. Portanto, procura-se um protocolo de descolagem com bases científicas. OBJETIVO: objetivou-se avaliar por microscopia eletrônica de varredura (MEV) a influência de quatro protocolos de remoção de braquetes e polimento da superfície do esmalte e propor um protocolo que minimize os danosà superfície do esmalte. MÉTODOS: doze incisivos permanentes bovinos foram divididos em quatro grupos de acordo com os instrumentos utilizados para a descolagem dos braquetes e remoção do remanescente adesivo. Os braquetes foram descolados com o alicate de descolagem reto (Ormco Corp.) nos grupos 1 e 2, e com o instrumento de descolagem Lift-Off (3M Unitek) nos grupos 3 e 4. Os remanescentes adesivos dos grupos 1 e 3 foram removidos com o alicate removedor de resina longo (Ormco Corp.) e dos grupos 2 e 4 com broca de carboneto de tungstênio (Beavers Dental) em alta-rotação. As superfícies, após cada etapa da descolagem e polimento, foram avaliadas em réplicas de resina epóxica e foram obtidas eletromicrografias com aumento de 50 e 200X. RESULTADOS: os quatro protocolos de remoção de acessórios ortodônticos e polimento ocasionaram irregularidades no esmalte. Conclusão: a remoção do braquete com o alicate de descolagem reto, seguido da remoção do remanescente adesivo com broca de carboneto de tungstênio e polimento final com pasta de pedra-pomes foi o procedimento que ocasionou menores danos ao esmalte, sendo o protocolo sugerido para a remoção dos acessórios ortodônticos.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this study was to compare the micromorphology of CVD diamond tips coupled to ultrasound with conventional high speed diamond tips after cavity preparations, and to measure the width and depth of the cavities obtained. Two hundred bovine teeth were divided into 20 subgroups. Each of the diamond tips (10 CVD and 10 conventional) were used to prepare 10 standardized cavities, using an apparatus that controlled the time (t: 27 s), speed (5.3 mm/s) and load (0.012 KGF) of the tip against the teeth during preparation. The unused and the used (after one, five and 10 preparations) tips were analyzed by scanning electronic microscopy. The images were randomly assessed by 3 examiners with regard to the presence or absence of micromorphologic alterations. Cavity measurements were made after visualization under a stereoscopic microscope. Cavity widths and depths were analyzed by the ANOVA Factorial test (p < 0.05). The CVD diamond tips presented less wear than the conventional tips after all the cavity preparations performed, but produced shallower cavities that were equivalent in width to those made by conventional tips after the fifth preparation. CVD diamond tips may be suggested as an alternative to conventional diamond tips due to their conservative preparation and greater longevity.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: To analyze the smear layer and the hybrid layer in noncarious and carious dentin prepared by different cutting instruments and restored with composite resin. Study design: Cavities were randomly prepared in 160 specimens (noncarious and artificial carious dentin) by high-speed diamond tips (KG Sorensen 1013), air abrasion system (Prepstart, Danville Engineering), ultrasonic tip (CVDentus 8.3231-1), and ultrasonic tip associated with ultrasonic cavitation by water for 10 s. Half of the cavities in each group were conditioned with 37% phosphoric acid for 15 s. The amount of smear layer and dentinal tubules present were analyzed using scanning electron microscopy and graded from 0 to 3. Cavities were prepared in another 20 noncarious specimens and 20 carious specimens and restored with adhesive composite resin system. The restorations were hemisected longitudinally and analyzed using scanning electron microscopy to evaluate the hybrid layer and resinous prolongation characteristics, using scores ranging from 1 to 6. Results: The data were statistically analyzed using Kruskal-Wallis and Dunn tests at 5% of significance level. There was evidence that the most efficient smear layer removal was the acid etching in the noncarious dentin and the water ultrasonic cavitation in the carious dentin. The hybrid layer formed on the noncarious and carious dentin prepared by the ultrasonic tip was more regular than in the specimens prepared by high-speed diamond tip, with many resinous prolongations. Conclusion: The ultrasonic tip seems to be a promising tool for carious dentin cavity preparation. Microsc. Res. Tech. 73:597-605, 2010. (C) 2009 Wiley-Liss, Inc.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Quando qualquer instrumento abrasiona ou corta a dentina, produz na superfície uma camada de lama dentinária ou smear layer. Dependendo do agente de união indicado em Odontologia adesiva, há a necessidade ou não da remoção da camada de lama da superfície dentinária. Com a finalidade de verificar a ação de diferentes substâncias para a limpeza dentinária, utilizamos 20 dentes pré-molares superiores íntegros, mantidos em soro fisiológico, nos quais as coroas foram seccionadas ao meio no sentido mésio-distal. Com instrumento diamantado, removeu-se o esmalte da porção vestibular e da porção lingual da coroa e, com uma broca carbide cilíndrica lisa nº 56, cortou-se aproximadamente 1 mm de dentina com alta rotação sob abundante refrigeração ar/água, para produzir a camada de lama dentinária. em seguida, essa superfície foi tratada com diferentes substâncias e lavada por 30 segundos com spray ar/água. No controle, foi simplesmente utilizado o spray ar/água. Os espécimes foram montados em suportes metálicos, preparados e visualizados no MEV-DSM 950 da Zeiss, em aumentos que variaram de 100 a 5.000 vezes. Os materiais que mais removeram a camada de lama foram, em ordem crescente: 1. spray ar/água; 2. fluoreto de sódio 2%; 3. associação alternada de Dakin/Tergensol; 4. água oxigenada 3%; 5. jateamento com óxido de alumínio 50 mm; 6. flúor acidulado 1,27%; 7. ácido poliacrílico 25%; 8. ácido fosfórico 10%.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: The aim of this study was to evaluate the influence of dentin abrasion on the microshear bond strength of two self-etching adhesive systems, using either an ultrasound diamond bur or a high-speed diamond bur.Materials and Methods: Twenty noncarious human third molars were sectioned mesiodistally into halves. The enamel was ground to expose a flat dentin surface on both sections. The dentinal surfaces were randomly assigned to two groups, depending on the method of smear layer preparation: ultrasound diamond bur (UB) or conventional diamond bur (CB). The prepared dentin surfaces received one of two self-etching systems: Clearfil SE Bond (CF) and One-Up Bond F (OB). A composite cylinder with a 0.95-mm diameter was bonded to each specimen and the microshear bond test was performed. The results were expressed in MPa and were subjected to two-way analysis of variance (ANOVA) and Tukey's test (alpha = 0.05).Results: There was no significant difference in dentin bond strength when comparing the conventional and ultrasonic abrasion methods. When the adhesive systems were compared, Clearfil SE Bond achieved higher bond strength means than did One-Up Bond F.Conclusion: The dentin surface preparation method did not influence the microshear bond strength and the Clearfil SE Bond adhesive system, independent of bur type used, Clearfil SE Bond showed higher bond strengths than did the One-Up Bond F adhesive system.