954 resultados para frequency analysis


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The article discusses a proposal of displacement measurement using a unique digital camera aiming at to exploit its feasibility for Modal Analysis applications. The proposal discusses a non-contact measuring approach able to measure multiple points simultaneously by using a unique digital camera. A modal analysis of a reduced scale lab building structure based only at the responses of the structure measured with the camera is presented. It focuses at the feasibility of using a simple ordinary camera for performing the output only modal analysis of structures and its advantage. The modal parameters of the structure are estimated from the camera data and also by using ordinary experimental modal analysis based on the Frequency Response Function (FRF) obtained by using the usual sensors like accelerometer and force cell. The comparison of the both analysis showed that the technique is promising noncontact measuring tool relatively simple and effective to be used in structural modal analysis

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A three-laser heterodyne system was used to measure the frequencies of twelve optically pumped laser emissions from 13CH3OH in the far-infrared (FIR) region. These emissions, ranging from 54 to 142 μm, are reported with fractional uncertainties up to ±2 × 10-7 along with their polarization relative to the CO2 pump. Using the 9P32 and 10R14 CO2 lines, complete spectroscopic assignments for two laser systems were confirmed.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Most work on supersingular potentials has focused on the study of the ground state. In this paper, a global analysis of the ground and excited states for the successive values of the orbital angular momentum of the supersingular plus quadratic potential is carried out, making use of centrifugal plus quadratic potential eigenfunction bases. First, the radially nodeless states are variationally analyzed for each value of the orbital angular momentum using the corresponding functions of the bases; the output includes the centrifugal and frequency parameters of the auxiliary potentials and their eigenfunction bases. In the second stage, these bases are used to construct the matrix representation of the Hamiltonian of the system, and from its diagonalization the energy eigenvalues and eigenvectors of the successive states are obtained. The systematics of the accuracy and convergence of the overall results are discussed with emphasis on the dependence on the intensity of the supersingular part of the potential and on the orbital angular momentum.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The synaptonemal complex (SC) was analyzed in four F1 hybrids of Bos taurus taurus and B. taurus indicus including Gyr-Simmental (G-S), Nelore Simmental (N-S), Gyr-Holstein-Friesian (G-H) and Nelore-Piemontese (N-P). We analysed the frequency of various types of SC abnormalities and the frequency of cells with SC abnormalities. The results were compared with similar observations made on purebred animals. All the animals studied possessed 29 autosomal and one sex bivalent. The frequency of cells with abnormalities in the hybrids were 28.0% in the N-P, 29.1% in the G-S, 33.3% in the N-S and 40.0% in the G-H. The frequency of cells with abnormalities in the four hybrids was 31.5%; 57.9% of these abnormalities occurred in zygotene and 42.0% occurred in pachytene. The comparisons among the hybrids and among the hybrids and their parental breeds showed that the only significant difference was between Gyr and Gyr-Holstein-Friesian animals. Some aspects of the relationship between the frequency of cells with anomalies and the fertility of hybrids are discussed.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Despite its high incidence, patellofemoral pain etiology remains unclear. No prior study has compared surface electromyography frequency domain parameters and surface electromyography time domain variables, which have been used as a classic analysis of patellofemoral pain. Thirty one women with patellofemoral pain and twenty eight pain-free women were recruited. Each participant was asked to descend a seven step staircase and data from five successful trials were collected. During the task, the vastus medialis and vastus lateralis muscle activities were monitored by surface electromyography. The data were processed and analyzed in four variables of the frequency domain (median frequency, low, medium and high frequency bands) and three time domain variables (Automatic, Cross-correlation and Visual Onset between the vastus medialis and vastus lateralis muscles). Reliability, Receiver Operating Characteristic curves and regression models were performed. The medium frequency band was the most reliable variable and different between the groups for both muscles, also demonstrated the best values of sensitivity and sensibility, 72% and 69% for the vastus medialis and 68% and 62% for the vastus lateralis, respectively. The frequency variables predicted the pain of individuals with patellofemoral pain, 26% for the vastus medialis and 20% for the vastus lateralis, being better than the time variables, which achieved only 7%. The frequency domain parameters presented greater reliability, diagnostic accuracy and capacity to predict pain than the time domain variables during stair descent and might be a useful tool to diagnose individuals with patellofemoral pain.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Patellofemoral pain syndrome (PFPS) is the most frequent complaint in orthopedic clinics; although, its etiology remains unclear [Bolgla, 2010; Felicio, 2011]. Trying to understand its causes has been used time analysis of electromyography (EMG), but this method shows controversies. The aim of this study was to apply a method of processing the EMG signal in the frequency domain of the vastus lateralis (VL) and vastus medialis (VM) muscles for the characterization of PFPS.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Natural frequencies were analyzed (axial, torsional and flexural) and frequency response of a vertical rotor with a hard disk at the edge through the classical and complex modal analysis. The mathematical modeling was based on the theory of Euler-Bernoulli beam. The equation that rules the movement was obtained through the Lagrangian formulation. The model considered the effects of bending, torsion and axial deformation of the shaft, besides the gravitational and gyroscopic effects. The finite element method was used to discretize the structure into hollow cylindrical elements with 12 degrees of freedom. Mass, stiffness and gyroscopic matrices were explained consistently. This type of tool, based on the use of complex coordinates to describe the dynamic behavior of rotating shaft, allows the decomposition of the system in two submodes, backward and forward. Thus, it is possible to clearly visualize that the orbit and direction of the precessional motion around the line of the rotating shaft is not deformed. A finite element program was developed using Matlab ®, and numerical simulations were performed to validate this model.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Fire scar and vegetative analysis were used to construct a fire history for the Engelmann spruce/subalpine fir (Picea engelmannii/Abies lasiocarpa) vegetation type of the Utah State University (USU) T. W Daniel Experimental Forest. Three distinct periods of fire frequency were established-presettlement (1700-1855), settlement (1856-1909), and suppression (1910-1990). Mean fire interval (MFI) decreased during the settlement period and greatly increased during the suppression era. The difference was attributed to the influx of ignition sources during the settlement of nearby Cache Valley, located 40 km to the west. Logging and livestock grazing appear to have led to the reduced MFI, which in turn worked as a factor to create the vegetative mosaic now observed on the study area. The increase in MFI during the suppression era permitted the advancement of shade-tolerant species in the understory of the shade-intolerant lodgepole pine (Pinus contorta var. latifolia) and quaking aspen (Populus tremuloides). Continued suppression of disturbance from wildfire will allow the lodgepole pine cover type, which experienced the lowest MFI during the settlement period, to be further invaded by shade-tolerant species, decreasing spatial stand diversity and increasing the risk of more intense fires.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The aim of this study was to evaluate micronucleus (MN) frequency in polychromatic erythrocytes (PCE) of female rats in persistent estrus (a model developed to mimic polycystic ovary syndrome) treated with selective estrogen receptor modulators (SERMs, tamoxifen, and raloxifene). Forty female Wistar-Hannover rats were divided into four groups of 10 animals each: Group I (normally cycling rats) and Group II (persistent estrus) both received only vehicle, while Group III (persistent estrus) was treated with tamoxifen (250 mu g/animal/day) and Group IV (persistent estrus) was treated with raloxifene (750 mu g/animal/day). Tamoxifen and raloxifene were given by oral gavage beginning on postnatal day 90 and continuing for 30 consecutive days. Peripheral blood samples were collected from tails 1 day following the last exposure. Blood smears were made on glass slides and stained with 10% Giemsa solution. ANOVA and a Tukey post-hoc test were used for data analysis. Mean percentages of MN were 1.82 +/- 0.13, 5.20 +/- 0.24, 3.32 +/- 0.13, and 3.04 +/- 0.12 in Groups I, II, III, and IV, respectively. The results indicate that tamoxifen and raloxifene similarly reduced the formation of MNPCE of female rats in persistent estrus (P < 0.0001 for Groups III and IV vs. Group II), using the dosages and time periods applied in the present study. The data suggest possibly antimutagenic effects of SERMs under high levels of estrogens. The findings also suggest that this is an interesting animal model for studying the genotoxicity of estrogens. Environ. Mol. Mutagen. 2012. (C) 2011 Wiley Periodicals, Inc.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The class of electrochemical oscillators characterized by a partially hidden negative differential resistance in an N-shaped current potential curve encompasses a myriad of experimental examples. We present a comprehensive methodological analysis of the oscillation frequency of this class of systems and discuss its dependence on electrical and kinetic parameters. The analysis is developed from a skeleton ordinary differential equation model, and an equation for the oscillation frequency is obtained. Simulations are carried out for a model system, namely, the nickel electrodissolution, and the numerical results are confirmed by experimental data on this system. In addition, the treatment is further applied to the electro-oxidation of ethylene glycol where unusually large oscillation frequencies have been reported. Despite the distinct chemistry underlying the oscillatory dynamics of these systems, a very good agreement between experiments and theoretical predictions is observed. The application of the developed theory is suggested as an important step for primary kinetic characterization.