898 resultados para esophagus stenosis


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Transcatheter aortic valve replacement (TAVR) as well as thoracic and abdominal endovascular aortic repair (TEVAR and EVAR) rely on accurate pre- and postprocedural imaging. This review article discusses the application of imaging, including preprocedural assessment and measurements as well as postprocedural imaging of complications. Furthermore, the exciting perspective of computational fluid dynamics (CFD) based on cross-sectional imaging is presented. TAVR is a minimally invasive alternative for treatment of aortic valve stenosis in patients with high age and multiple comorbidities who cannot undergo traditional open surgical repair. Given the lack of direct visualization during the procedure, pre- and peri-procedural imaging forms an essential part of the intervention. Computed tomography angiography (CTA) is the imaging modality of choice for preprocedural planning. Routine postprocedural follow-up is performed by echocardiography to confirm treatment success and detect complications. EVAR and TEVAR are minimally invasive alternatives to open surgical repair of aortic pathologies. CTA constitutes the preferred imaging modality for both preoperative planning and postoperative follow-up including detection of endoleaks. Magnetic resonance imaging is an excellent alternative to CT for postoperative follow-up, and is especially beneficial for younger patients given the lack of radiation. Ultrasound is applied in screening and postoperative follow-up of abdominal aortic aneurysms, but cross-sectional imaging is required once abnormalities are detected. Contrast-enhanced ultrasound may be as sensitive as CTA in detecting endoleaks.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

INTRODUCTION: Voluntary muscle activity, including swallowing, decreases during the night. The association between nocturnal awakenings and swallowing activity is under-researched with limited information on the frequency of swallows during awake and asleep periods. AIM: The aim of this study was to assess nocturnal swallowing activity and identify a cut-off predicting awake and asleep periods. METHODS: Patients undergoing impedance-pH monitoring as part of GERD work-up were asked to wear a wrist activity detecting device (Actigraph(®)) at night. Swallowing activity was quantified by analysing impedance changes in the proximal esophagus. Awake and asleep periods were determined using a validated scoring system (Sadeh algorithm). Receiver operating characteristics (ROC) analyses were performed to determine sensitivity, specificity and accuracy of swallowing frequency to identify awake and asleep periods. RESULTS: Data from 76 patients (28 male, 48 female; mean age 56 ± 15 years) were included in the analysis. The ROC analysis found that 0.33 sw/min (i.e. one swallow every 3 min) had the optimal sensitivity (78 %) and specificity (76 %) to differentiate awake from asleep periods. A swallowing frequency of 0.25 sw/min (i.e. one swallow every 4 min) was 93 % sensitive and 57 % specific to identify awake periods. A swallowing frequency of 1 sw/min was 20 % sensitive but 96 % specific in identifying awake periods. Impedance-pH monitoring detects differences in swallowing activity during awake and asleep periods. Swallowing frequency noticed during ambulatory impedance-pH monitoring can predict the state of consciousness during nocturnal periods

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We examined outcomes and trends in surgery and radiation use for patients with locally advanced esophageal cancer, for whom optimal treatment isn't clear. Trends in surgery and radiation for patients with T1-T3N1M0 squamous cell or adenocarcinoma of the mid or distal esophagus in the Surveillance, Epidemiology, and End Results database from 1998 to 2008 were analyzed using generalized linear models including year as predictor; Surveillance, Epidemiology, and End Results doesn't record chemotherapy data. Local treatment was unimodal if patients had only surgery or radiation and bimodal if they had both. Five-year cancer-specific survival (CSS) and overall survival (OS) were analyzed using propensity-score adjusted Cox proportional-hazard models. Overall 5-year survival for the 3295 patients identified (mean age 65.1 years, standard deviation 11.0) was 18.9% (95% confidence interval: 17.3-20.7). Local treatment was bimodal for 1274 (38.7%) and unimodal for 2021 (61.3%) patients; 1325 (40.2%) had radiation alone and 696 (21.1%) underwent only surgery. The use of bimodal therapy (32.8-42.5%, P = 0.01) and radiation alone (29.3-44.5%, P < 0.001) increased significantly from 1998 to 2008. Bimodal therapy predicted improved CSS (hazard ratios [HR]: 0.68, P < 0.001) and OS (HR: 0.58, P < 0.001) compared with unimodal therapy. For the first 7 months (before survival curve crossing), CSS after radiation therapy alone was similar to surgery alone (HR: 0.86, P = 0.12) while OS was worse for surgery only (HR: 0.70, P = 0.001). However, worse CSS (HR: 1.43, P < 0.001) and OS (HR: 1.46, P < 0.001) after that initial timeframe were found for radiation therapy only. The use of radiation to treat locally advanced mid and distal esophageal cancers increased from 1998 to 2008. Survival was best when both surgery and radiation were used.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND To investigate the role of nonsurgical treatment for early-stage esophageal cancer, we compared the outcomes of local therapy to esophagectomy, using a large, national database. METHODS Five-year cancer-specific and overall survival (OS) of patients, with T1N0M0 squamous cell or adenocarcinoma of the mid or distal esophagus treated with either surgery or local therapy, with ablative and/or excision techniques, in the Surveillance Epidemiology and End Results cancer registry from 1998 to 2008, were compared using the Kaplan-Meier approach, and multivariable and propensity-score adjusted Cox proportional hazard, and competing risk models. RESULTS Of 1458 patients with T1N0 esophageal cancer, 1204 (83%) had surgery and 254 (17%) had local therapy only. The use of local therapy increased significantly from 8.1% in 1998 to 24.1% in 2008 (p < 0.001). The 5-year OS after local excisional therapy and surgery was not significantly different (55.5% versus 64.1% respectively, p = 0.07), and 5-year cancer-specific survival (CSS) also did not differ (81.7% versus 75.8%, p = 0.10). However, after propensity-score adjustment, CSS was better for patients who underwent local therapy compared with those who underwent surgery (hazard ratio: 0.46, 95% confidence interval: 0.27-0.77, p = 0.003), whereas OS remained similar. CONCLUSION The use of local therapy for T1N0 esophageal cancers increased significantly from 1998 to 2008. Compared with those treated with esophagectomy, patients treated with local therapy had similar OS but improved CSS, indicating a higher chance of dying from other causes. Further studies are needed to confirm the oncologic efficacy of local therapy when used in patients whose lifespans are not limited by conditions other than esophageal cancer.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVES To describe clinical-radiologic characteristics in a prospective series of patients having both confirmed reversible cerebral vasoconstriction syndrome (RCVS) and cervical artery dissection (CeAD). METHODS From January 2004 to December 2011, from our prospective cohorts of RCVS and CeAD, we studied patients with both conditions. RESULTS Of 173 RCVS cases and 285 CeAD cases, 20 patients (18 women, 2 men; mean age 41 years) had both RCVS and CeAD. Main associated conditions were migraine (12/20) and postpartum (5/18). Clinical features included severe headache in all patients, neck pain in 15, focal neurologic deficit in 9, and seizures in 4. Pain was the only symptom in 10 patients. All patients had multifocal cerebral vasoconstriction. There were brain lesions in 12 patients, cortical subarachnoid hemorrhage in 11, posterior reversible encephalopathy syndrome in 4, intracerebral hemorrhage in 3, and infarcts in 4. CeAD involved one artery in 13 patients and multiple arteries in 7. CeAD mostly affected vertebral arteries (25 of 30 CeAD). Only one vertebral CeAD was associated with a related symptomatic infarct. At 3 months, 18 patients had fully recovered, all patients showed reversal of cerebral vasoconstriction, and 21 dissected arteries had normalized, whereas 9 arteries showed residual stenosis (7) and/or aneurysm (3). CONCLUSION The association of RCVS and CeAD was found in 12% of our patients with RCVS and 7% of our patients with CeAD. Underlying mechanisms are unknown. In practice, our results point to the need for a systematic study of both cervical and intracranial arteries in the 2 conditions.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background Biodegradable polymers for release of antiproliferative drugs from metallic drug-eluting stents (DES) aim to improve long-term vascular healing and efficacy. We designed a large scale clinical trial to compare a novel thin strut, cobalt chromium DES with silicon carbide coating releasing sirolimus from a biodegradable polymer (Orsiro, O-SES) with the durable polymer-based Xience Prime everolimus-eluting stent (X-EES) in an all-comers patient population. Design The multicenter BIOSCIENCE trial (NCT01443104) randomly assigned 2,119 patients to treatment with biodegradable polymer SES or durable polymer EES at 9 sites in Switzerland. Patients with chronic stable coronary artery disease or acute coronary syndromes, including non-ST-elevation and ST-elevation myocardial infarction, were eligible for the trial if they had at least one lesion with a diameter stenosis >50% appropriate for coronary stent implantation. The primary endpoint target lesion failure (TLF) is a composite of cardiac death, target-vessel myocardial infarction, and clinically-driven target lesion revascularization within 12 months. Assuming a TLF rate of 8% at 12 months in both treatment arms and accepting 3.5% as a margin for non-inferiority, inclusion of 2,060 patients would provide 80% power to detect non-inferiority of the biodegradable polymer SES compared with the durable polymer EES at a one-sided type I error of 0.05. Clinical follow-up will be continued through five years. Conclusion The BIOSCIENCE trial will determine whether the biodegradable polymer SES is non-inferior to the durable polymer EES with respect to TLF.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND This study sought to determine whether the 1-year differences in major adverse cardiac event between a stent eluting biolimus from a biodegradable polymer and bare-metal stents (BMSs) in the COMFORTABLE trial (Comparison of Biolimus Eluted From an Erodible Stent Coating With Bare Metal Stents in Acute ST-Elevation Myocardial Infarction) were sustained during long-term follow-up. METHODS AND RESULTS A total of 1061 patients were randomly assigned to biolimus-eluting stent (BES) and BMS at 11 centers, and follow-up rates at 2 years were 96.3%. A subgroup of 103 patients underwent angiography at 13 months. At 2 years, differences in the primary end point of cardiac death, target-vessel myocardial infarction, and target lesion revascularization continued to diverge in favor of BES-treated patients (5.8%) compared with BMS-treated patients (11.9%; hazard ratio=0.48; 95% confidence interval, 0.31-0.72; P<0.001) with a significant risk reduction during the second year of follow-up (hazard ratio 1-2 years=0.45; 95% confidence interval, 0.20-1.00; P=0.049). Differences in the primary end point were driven by a reduction in target lesion revascularization (3.1% versus 8.2%; P<0.001) and target-vessel reinfarction (1.3% versus 3.4%; P=0.023). The composite of death, any reinfarction and revascularization (14.5% versus 19.3%; P=0.03), and cardiac death or target-vessel myocardial infarction (4.2% versus 7.2%; P=0.036) were less frequent among BES-treated patients compared with BMS-treated patients. The 13-month angiographic in-stent percent diameter stenosis amounted to 12.0±7.2 in BES- and 39.6±25.2 in BMS-treated lesions (P<0.001). CONCLUSIONS Among patients with ST-segment-elevation myocardial infarction undergoing primary percutaneous coronary intervention, BES continued to improve cardiovascular events compared with BMS beyond 1 year.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The oral route is the most frequently used method of drug intake in humans. Oral administration of drugs to laboratory animals such as mice typically is achieved through gavage, in which a feeding needle is introduced into the esophagus and the drug is delivered directly into the stomach. This method requires technical skill, is stressful for animals, and introduces risk of injury, pain and morbidity. Here we investigated another method of drug administration. The benzimidazole derivative albendazole was emulsified in commercially available honey and administered to mice by voluntary feeding or gavage. Mice that received albendazole by either gavage or honey ingestion had virtually identical levels of serum albendazole sulfoxide, indicating that uptake and metabolism of albendazole was similar for both administration techniques. In addition, dosing mice with the albendazole-honey mixture for 8 wk had antiparasitic activity comparable to earlier studies using gavage for drug administration. Compared with gavage, voluntary ingestion of a drug in honey is more rapid, less stressful to the animal, and less technically demanding for the administrator. Because of its low cost and ready availability, honey presents a viable vehicle for drug delivery.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background We hypothesized that in patients with stable coronary artery disease and stenosis, percutaneous coronary intervention (PCI) performed on the basis of the fractional flow reserve (FFR) would be superior to medical therapy. Methods In 1220 patients with stable coronary artery disease, we assessed the FFR in all stenoses that were visible on angiography. Patients who had at least one stenosis with an FFR of 0.80 or less were randomly assigned to undergo FFR-guided PCI plus medical therapy or to receive medical therapy alone. Patients in whom all stenoses had an FFR of more than 0.80 received medical therapy alone and were included in a registry. The primary end point was a composite of death from any cause, nonfatal myocardial infarction, or urgent revascularization within 2 years. Results The rate of the primary end point was significantly lower in the PCI group than in the medical-therapy group (8.1% vs. 19.5%; hazard ratio, 0.39; 95% confidence interval [CI], 0.26 to 0.57; P<0.001). This reduction was driven by a lower rate of urgent revascularization in the PCI group (4.0% vs. 16.3%; hazard ratio, 0.23; 95% CI, 0.14 to 0.38; P<0.001), with no significant between-group differences in the rates of death and myocardial infarction. Urgent revascularizations that were triggered by myocardial infarction or ischemic changes on electrocardiography were less frequent in the PCI group (3.4% vs. 7.0%, P=0.01). In a landmark analysis, the rate of death or myocardial infection from 8 days to 2 years was lower in the PCI group than in the medical-therapy group (4.6% vs. 8.0%, P=0.04). Among registry patients, the rate of the primary end point was 9.0% at 2 years. Conclusions In patients with stable coronary artery disease, FFR-guided PCI, as compared with medical therapy alone, improved the outcome. Patients without ischemia had a favorable outcome with medical therapy alone. (Funded by St. Jude Medical; FAME 2 ClinicalTrials.gov number, NCT01132495 .).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

STUDY OBJECTIVE To determine the effectiveness of an esophageal doppler device to non-invasively detect experimental pseudo-electromechanical dissociation (pseudo-EMD). DESIGN Prospective, controlled, laboratory investigation using an asphyxial canine cardiac arrest model and a newly-developed esophageal flat-flow probe doppler unit. INTERVENTIONS Mongrel dogs (20) were instrumented for hemodynamic monitoring. The esophageal doppler probe was placed in the distal esophagus of each animal. Electromechanical dissociation (EMD) was induced by clamping the endotracheal tube. MEASUREMENTS AND MAIN RESULTS A period of pseudo-EMD was defined as the time where cardiac contractility was present, measured by a micromanometer tipped thoracic aortic catheter, without concurrent femoral pulses by palpation. The pseudo-EMD period could be produced consistently in all 20 animals. The characteristic doppler flow sounds were easily heard using the esophageal device in all animals. The time from endotracheal tube clamping until loss of femoral pulses was 622 +/- 96 s; until loss of radial artery doppler signals was 616 +/- 92 s; until loss of esophageal doppler signals was 728 +/- 88 s; and until loss of aortic fluctuations by thoracic aortic catheter was 728 +/- 82 s. The times to loss of esophageal doppler sounds and loss of aortic fluctuations were not significantly different. However, they were significantly longer than the time to loss of femoral pulses (P < 0.02). CONCLUSIONS The canine asphyxial EMD model can be used for short experimental studies of pseudo-EMD. Pseudo-EMD can be consistently and non-invasively detected with this esophageal doppler device. The device is as reliable as a micromanometer tipped aortic arch catheter in detecting pseudo-EMD. The doppler device could potentially be useful in improving recognition of near cardiac arrest in pre-hospital and emergency department settings. Further research on the utility of this device in other models of low-flow states should be performed.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Introduction: Cervical vertebral (C) malformation is rarely reported in large breed dogs. Congenital cervical kyphosis (CCK) may result from defects of vertebral segmentation, failure of formation or both. This report describes two cases of C3-C4 CCK in young sighthounds, treated surgically. Case description: An 18-month-old female Deerhound and a six-week-old female Borzoi dog were presented because of the complaints of reluctance to exercise and signs of of neck pain. Both dogs were neurologically normal. Diagnostic imaging revealed C3-C4 deformity, moderate kyphosis, and spinal canal stenosis associated with chronic spinal cord pressure atrophy. Both dogs underwent surgical treatment. Results: A staged two-step surgery starting with dorsal decompression was elected in the Deerhound. After the first surgical procedure, the dog developed focal myelomalacia and phrenic nerve paralysis and was euthanatized. A ventral distraction-fusion technique with two locking plates was performed in the Borzoi. This patient recovered uneventfully and long-term follow-up computed tomography revealed complete spondylodesis. Clinical significance: Until now, CCK has only been described in sighthounds. Congenital cervical kyphosis might be considered a differential diagnosis in these breeds that are presented with signs of cervical pain. Ventral realignment-fusion and bone grafting may be considered for surgical treatment, although the earliest age at which this procedure can and should be performed remains unclear.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A study was designed to describe a novel approach to the treatment of tracheal collapse (TC) in dogs using self-expandable nitinol stents. Medical records were reviewed retrospectively for 26 client owned dogs in which nitinol stents were deployed. The entire length of trachea was supported independently of the extent of TC. Two overlapping stents were used instead of one in cases where one stent was not spanning the entire trachea adequately. The diameter of the cranial radiolucent portion of trachea, just behind the cricoid cartilage, was measured as a specific landmark to select the appropriate size of the stent. Two self-expandable nitinol stents were inserted in 9 of 26 dogs; the trachea in the rest of the cases was supported with only one stent. A follow up tracheoscopy was performed in 10 of 26 cases with recurrent clinical signs. Secondary tracheal stenosis in these cases was caused by stent fracture, granuloma or excessive stent shortening. Additional stents were placed successfully to expand the stenotic lumen. A support of the entire trachea may decrease risk of nitinol fracture at the end of the implant. Long term clinical improvement (25 of 26 dogs, 96 %) is comparable with the results of other studies.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE To assess the usefulness of cone beam CT (CBCT) for dacryocystography (DCG) using either direct syringing or passive application of contrast medium. METHODS Ten consecutive patients with epiphora who had CBCT-DCG in a sitting position were retrospectively analyzed. CBCT-DCGs were performed using 2 techniques: direct syringing with contrast medium or using the passive technique, where patients received 3 drops of contrast medium into the conjunctival sac before CBCT-DCG. Clinical and radiologic diagnoses were compared for both groups. RESULTS The 10 patients (men = 3) had a mean age of 63.2 years. Both techniques proved to be simple procedures with good delineation of the bone, soft tissue, and the contrast medium in the lacrimal system. No side effects were noted. CONCLUSIONS CBCT-DCG is a useful alternative to determine the localization of stenosis in patients with chronic epiphora.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Aims: We sought to analyse local distribution of aortic annulus and left ventricular outflow tract (LVOT) calcification in patients undergoing transcatheter aortic valve replacement (TAVR) and its impact on aortic regurgitation (AR) immediately after device placement. Methods and results: A group of 177 patients with severe aortic stenosis undergoing multislice computed tomography of the aortic root followed by TAVR were enrolled in this single-centre study. Annular and LVOT calcifications were assessed per cusp using a semi-quantitative grading system (0: none; 1 [mild]: small, non-protruding calcifications; 2 [moderate]: protruding [>1 mm] or extensive [>50% of cusp sector] calcifications; 3 [severe]: protruding and extensive calcifications). Any calcification of the annulus or LVOT was present in 107 (61%) and 63 (36%) patients, respectively. Prevalence of annulus/LVOT calcifications in the left coronary cusp was 42% and 25%, respectively, in the non-coronary cusp 28% and 13%, in the right coronary cusp 13% and 5%. AR grade 2 to 4 assessed by the method of Sellers immediately after TAVR device implantation was observed in 55 patients (31%). Multivariate regression analysis revealed that the overall annulus calcification (OR [95% CI] 1.48 [1.10-2.00]; p=0.0106), the overall LVOT calcification (1.93 [1.26-2.96]; p=0.0026), any moderate or severe LVOT calcification (5.37 [1.52-18.99]; p=0.0092), and asymmetric LVOT calcification were independent predictors of AR. Conclusions: Calcifications of the aortic annulus and LVOT are frequent in patients undergoing TAVR, and both the distribution and the severity of calcifications appear to be independent predictors of aortic regurgitation after device implantation. - See more at: http://www.pcronline.com/eurointervention/77th_issue/126/#sthash.Hzodgju5.dpuf

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND Limited information exists describing the results of transcatheter aortic valve (TAV) replacement in patients with bicuspid aortic valve (BAV) disease (TAV-in-BAV). OBJECTIVES This study sought to evaluate clinical outcomes of a large cohort of patients undergoing TAV-in-BAV. METHODS We retrospectively collected baseline characteristics, procedural data, and clinical follow-up findings from 12 centers in Europe and Canada that had performed TAV-in-BAV. RESULTS A total of 139 patients underwent TAV-in-BAV with the balloon-expandable transcatheter heart valve (THV) (n = 48) or self-expandable THV (n = 91) systems. Patient mean age and Society of Thoracic Surgeons predicted risk of mortality scores were 78.0 ± 8.9 years and 4.9 ± 3.4%, respectively. BAV stenosis occurred in 65.5%, regurgitation in 0.7%, and mixed disease in 33.8% of patients. Incidence of type 0 BAV was 26.7%; type 1 BAV was 68.3%; and type 2 BAV was 5.0%. Multislice computed tomography (MSCT)-based TAV sizing was used in 63.5% of patients (77.1% balloon-expandable THV vs. 56.0% self-expandable THV, p = 0.02). Procedural mortality was 3.6%, with TAV embolization in 2.2% and conversion to surgery in 2.2%. The mean aortic gradient decreased from 48.7 ± 16.5 mm Hg to 11.4 ± 9.9 mm Hg (p < 0.0001). Post-implantation aortic regurgitation (AR) grade ≥2 occurred in 28.4% (19.6% balloon-expandable THV vs. 32.2% self-expandable THV, p = 0.11) but was prevalent in only 17.4% when MSCT-based TAV sizing was performed (16.7% balloon-expandable THV vs. 17.6% self-expandable THV, p = 0.99). MSCT sizing was associated with reduced AR on multivariate analysis (odds ratio [OR]: 0.19, 95% confidence intervals [CI]: 0.08 to 0.45; p < 0.0001). Thirty-day device safety, success, and efficacy were noted in 79.1%, 89.9%, and 84.9% of patients, respectively. One-year mortality was 17.5%. Major vascular complications were associated with increased 1-year mortality (OR: 5.66, 95% CI: 1.21 to 26.43; p = 0.03). CONCLUSIONS TAV-in-BAV is feasible with encouraging short- and intermediate-term clinical outcomes. Importantly, a high incidence of post-implantation AR is observed, which appears to be mitigated by MSCT-based TAV sizing. Given the suboptimal echocardiographic results, further study is required to evaluate long-term efficacy.