953 resultados para end-systolic pressure-diameter relations
Resumo:
The influence of 2 different levels of the inspired oxygen fraction (FiO(2)) on blood gas variables was evaluated in dogs with high intracranial pressure (ICP) during propofol anesthesia (induction followed by a continuous rate infusion [CRI] of 0.6 mg/kg/min) and intermittent positive pressure ventilation (IPPV). Eight adult mongrel dogs were anesthetized on 2 occasions, 21 d apart, and received oxygen at an FiO(2) of 1.0 (G100) or 0.6 (G60) in a randomized crossover fashion. A fiberoptic catheter was implanted on the surface of the right cerebral cortex for assessment of the ICP. An increase in the ICP was induced by temporary ligation of the jugular vein 50 min after induction of anesthesia and immediately after baseline measurement of the ICP. Blood gas measurements were taken 20 min later and then at 15-min intervals for 1 h. Numerical data were submitted to Morrison's multivariate statistical methods. The ICP, the cerebral perfusion pressure and the mean arterial pressure did not differ significantly between FiO(2) levels or measurement times after jugular ligation. The only blood gas values that differed significantly (P < 0.05) were the arterial oxygen partial pressure, which was greater with G100 than with G60 throughout the procedure, and the venous haemoglobin saturation, that was greater with G100 than with G60 at M0. There were no significant differences between FiO(2) levels or measurement times in the following blood gas variables: arterial carbon dioxide partial pressure, arterial hemoglobin saturation, base deficit, bicarbonate concentration, pH, venous oxygen partial pressure, venous carbon dioxide partial pressure and the arterial-to-end-tidal carbon dioxide difference.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Avaliou-se a pressão intra-ocular (PIO) e estimaram-se as correlações entre PIO e pressão de dióxido de carbono (PaCO2) e pH arterial de cinco caracarás (Caracara plancus), anestesiados com isofluorano (ISO) ou sevofluorano (SEV). Valores basais da PIO foram aferidos em ambos os olhos (M0). Cateterizou-se previamente a artéria braquial para obtenção de parâmetros hemogasométricos e cardiorrespiratórios. Anestesia foi induzida com ISO a 5V% e mantida por 40 minutos com 2,5V%. PIO e amostras de sangue foram avaliadas em diferentes momentos até o final do procedimento. Após recuperação, uma segunda anestesia foi realizada com SEV a 6% e mantida com 3,5%. Os parâmetros foram aferidos nos mesmos momentos estabelecidos previamente. A PIO decresceu significativamente (P=0,012) de M0 em todos os momentos e não houve diferença estatística entre ISO e SEV. Correlações significativas entre PIO e PaCO2 e entre PIO e pH sangüíneo foram observadas apenas para a anestesia com SEV. O pH sangüíneo decresceu paralelamente a PIO, enquanto a PaCO2 aumentou, em carcarás anestesiados com isofluorano e sevofluorano.
Resumo:
The effects of adrenergic stimulation on mean circulatory filling pressure (MCFP), central venous pressure (P-CV) and stroke volume (Vs), as well as the effects of altered MCFP through changes of blood volume were investigated in rattlesnakes (Crotalus durissus). MCFP is an estimate of the upstream pressure driving blood towards the heart and is determined by blood volume and the activity of the smooth muscle cells in the veins (venous tone). MCFP can be determined as the plateau in P-CV during a total occlusion of blood flow from the heart.Vs decreased significantly when MCFP was lowered by reducing blood volume in anaesthetised snakes, whereas increased MCFP through infusion of blood (up to 3 ml kg(-1)) only led to a small rise in Vs. Thus, it seems that end-diastolic volume is not affected by an elevated MCFP in rattlesnakes. To investigate adrenergic regulation on venous tone, adrenaline as well as phenylephrine and isoproterenol (alpha- and beta-adrenergic agonists, respectively) were infused as bolus injections (2 and 10 mu g kg(-1)). Adrenaline and phenylephrine caused large increases in MCFP and P-CV, whereas isoproterenol decreased both parameters. This was also the case in fully recovered snakes. Therefore, adrenaline affects venous tone through both alpha- and beta-adrenergic receptors, but the alpha-adrenergic receptor dominates at the dosages used in the present study. Injection of the nitric oxide donor SNP caused a significant decrease in P-CV and MCFP. Thus, nitric oxide seems to affect venous tone.
Resumo:
The study was conducted at the Research Laboratory of Hydraulic and Irrigation Group in the Rural Engineering Department, Technical University of Madrid (Universidad Politecnica de Madrid), Madrid, Spain. Water temperatures of 20, 30, 40 degrees C and system pressures often encountered in irrigation practices of 80, 90, 100, 110, 120, 130, 140, 150, 160, 170, 180, 190 and 200 k Pa were applied to determine the effects of different water temperatures and pressures on emitter discharge. Non-pressure compensating in-line emitter which has turbulent flow regime with a long-path (labyrinth), emitter discharge was 4 L h(-1) at system pressure of 100 kPa according to the manufacturer recommended, was used. Emitters were spaced 20 cm along the drip laterals with 16 mm diameter. Discharge equations and coefficients of variation related to temperatures of 20, 30 and 40 degrees C were obtained as q = 0.375H(0.51), q = 0.358H(0.52), q = 0.346H(0.53) and 2.68, 2.09, 3.65, respectively. Discharge of the emitter was affected by different system pressures and increased as potentially (R = 0993-0996). In general. the emitter discharge increased with increasing temperature. However, especially in the common system pressures of 90-120 k Pa, differences of obtained emitter discharges between the different water temperatures were not significant (1%).
Resumo:
This study analyzed the accuracy/agreement of the Omron MX3 monitor on 165 adolescents. Blood pressure was measured by the automatic monitor connected in Y with the mercury column (three consecutive and simultaneous measures). The independent measures were analyzed, and the mean differences between systolic and diastolic measures for both methods were calculated and compared with British Hypertension Society (BHS) and Association for the Advancement of Medical Instrumentation (AAMI) criteria. The automatic monitor received the highest degree of BHS recommendations for systolic and diastolic blood pressures according to the BHS. The median (25th and 75th) difference between the observer and the monitor measurements was -2 (-6 and 1) mmHg for systolic and 0 (-3 and1) mmHg for diastolic pressures. The monitor also satisfies the AAMI standard for the studied population. In conclusion, the Omron MX3 Plus monitor can be considered reliable and valid for clinical practice and is in accordance with BHS and AAMI criteria.
Resumo:
INTRODUÇÃO: a necessidade de reposição ao máximo das perdas hídricas tornou-se estabelecida e difundida nos consensos internacionais. Entretanto, permanece pouco compreendida a influência da reposição quando administrada, igualmente, durante e após o exercício sobre parâmetros cardiorrespiratórios. OBJETIVO: analisar os efeitos da reposição hidroeletrolítica na frequência cardíaca (FC), pressão arterial sistólica (PAS), pressão arterial diastólica (PAD), saturação parcial de oxigênio (SpO2) e frequência respiratória (f) de jovens durante e após um exercício de longa duração. MÉTODOS: 31 jovens (21,55 ± 1,89 anos) realizaram três visitas ao laboratório (intervalo de 48 horas entre elas), sendo na primeira aplicado um teste incremental, para determinação da carga utilizada nas visitas seguintes, e nas duas últimas, denominadas protocolo controle (PC) e protocolo experimental (PE), os sujeitos foram submetidos a 10 min de repouso supino, 90 min de exercício em esteira ergométrica (60% do VO2pico) e 60 min de repouso supino. No PC não houve hidratação e no PE houve ingestão de solução isotônica. Os parâmetros FC, PAS, PAD, SpO2 e f foram mensurados no final do repouso; nos minutos 30, 60 e 90 do exercício, com exceção da f; e nos minutos 1, 3, 5, 7, 10, 20, 30, 40, 50 e 60 pós-exercício. Foi aplicado o teste t de Student ou teste de Mann-Whitney e ANOVA para medidas repetidas ou teste de Friedman seguidos de testes post hoc, com p < 0,05. RESULTADOS: a solução hidroeletrolítica proporcionou manutenção da PAS e da PAD, e menor incremento da FC durante o exercício; e promoveu retorno mais rápido da FC e conservou PAD, SpO2, PAS (a partir do 5º min) e f (a partir do 30º min) no período de recuperação. CONCLUSÃO: o protocolo de hidratação influenciou parâmetros cardiorrespiratórios de jovens durante e após a realização de atividade física submáxima de intensidade constante e longa duração.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
The work reported here involved an investigation into the grinding process, one of the last finishing processes carried out on a production line. Although several input parameters are involved in this process, attention today focuses strongly on the form and amount of cutting fluid employed, since these substances may be seriously pernicious to human health and to the environment, and involve high purchasing and maintenance costs when utilized and stored incorrectly. The type and amount of cutting fluid used directly affect some of the main output variables of the grinding process which are analyzed here, such as tangential cutting force, specific grinding energy, acoustic emission, diametrical wear, roughness, residual stress and scanning electron microscopy. To analyze the influence of these variables, an optimised fluid application methodology was developed (involving rounded 5, 4 and 3 turn diameter nozzles and high fluid application pressures) to reduce the amount of fluid used in the grinding process and improve its performance in comparison with the conventional fluid application method (of diffuser nozzles and lower fluid application pressure). To this end, two types of cutting fluid (a 5% synthetic emulsion and neat oil) and two abrasive tools (an aluminium oxide and a superabrasive CBN grinding wheel) were used. The results revealed that, in every situation, the optimised application of cutting fluid significantly improved the efficiency of the process, particularly the combined use of neat oil and CBN grinding wheel. (c) 2005 Elsevier Ltd. All rights reserved.
Resumo:
This study compared pressure and thermal thresholds after administration of three opioids in eight cats. Pressure stimulation was performed via a bracelet taped around the forearm. Three ball-bearings were advanced against the forearm by inflation of a modified blood pressure bladder. Pressure in the cuff was recorded at the end point (leg shake and head turn). Thermal threshold was tested as previously reported using a heated probe held against the thorax [Dixon et al. (2002) Research in Veterinary Science, 72, 205]. After baseline recordings, each cat received subcutaneous methadone 0.2 mg/kg, morphine 0.2 mg/kg, buprenorphine 0.02 mg/kg or saline 0.3 mL in a four period cross-over study. Measurements were made at 15, 30, 45 min and 1, 2, 3, 4, 8, 12 and 24 h after the injection. Data were analysed by ANOVA (P < 0.05). There were no significant changes in thresholds after saline. Thermal threshold increased at 45 min after buprenorphine (maximum 2.8 +/- 3 degrees C), 1-3 h after methadone (maximum 3.4 +/- 1.9 degrees C) and 45 min to 1 h (maximum 3.4 +/- 2 degrees C) after morphine. Pressure threshold increased 30-45 min (maximum 238 +/- 206 mmHg) after buprenorphine, 45-60 min after methadone (maximum 255 +/- 232 mmHg) and 45-60 min and 3-6 h (maximum 255 +/- 232 mmHg) after morphine. Morphine provided the best analgesia, and methadone appears a promising alternative. Buprenorphines limited effect was probably related to the subcutaneous route of administration. Previously, buprenorphine has produced much greater effects when given by other routes.
Resumo:
JUSTIFICATIVA E OBJETIVOS: O pinçamento aórtico infra-renal pode determinar alterações cardiovasculares. A clonidina, um alfa2-agonista, determina bradicardia e diminuição da pressão arterial. O objetivo do estudo foi avaliar os efeitos da clonidina sobre a função cardiovascular, em cães submetidos a pinçamento aórtico infra-renal. MÉTODO: O estudo aleatório foi realizado em 16 cães, distribuídos em dois grupos: G Controle - sem a utilização de clonidina e G Clon - clonidina, na dose inicial de 5 µg.kg-1, por via venosa, imediatamente antes do pinçamento aórtico infra-renal, seguido de 2 µg.min-1.m² até o final do estudo. em todos os animais foi realizada ligadura infra-renal da aorta, por 45 minutos. Os atributos hemodinâmicos foram estudados nos momentos C (controle), após 10 (Ao10) e 25 (Ao25) minutos do pinçamento aórtico, e após 10 (DAo10) e 25 (DAo25) minutos do despinçamento aórtico. RESULTADOS: Durante o pinçamento aórtico, houve diferença significante entre os grupos, em relação à freqüência cardíaca, pressão arterial média e índice cardíaco (G Controle > G Clon). Após o despinçamento aórtico houve diferença significante entre os grupos, em relação à freqüência cardíaca (G Controle > G Clon) e pressões do átrio direito e da artéria pulmonar ocluída (G Clon > G Controle). Durante o pinçamento aórtico, houve nos dois grupos, aumento significante das pressões de átrio direito e artéria pulmonar ocluída, dos índices sistólico e do trabalho sistólico do ventrículo esquerdo, e diminuição do índice de resistência vascular pulmonar. No grupo controle houve aumento significante das pressões arterial média e da artéria pulmonar, e dos índices cardíaco e do trabalho sistólico do ventrículo direito. No grupo clonidina, houve diminuição significante da freqüência cardíaca. Após o despinçamento aórtico, houve nos dois grupos: diminuição significante da freqüência cardíaca e pressão arterial média, enquanto os valores das pressões do átrio direito e índice sistólico continuaram elevados. No grupo controle, os valores do índice de trabalho sistólico do ventrículo direito continuaram elevados enquanto os valores do índice cardíaco retornaram a valores próximos aos do controle. No grupo clonidina, os valores das pressões do átrio direito e da artéria pulmonar ocluída, e o índice sistólico, continuaram significantemente elevados. CONCLUSÕES: No cão, nas condições experimentais empregadas, a administração venosa contínua de clonidina atenua as respostas cardiovasculares decorrentes do pinçamento aórtico infra-renal.
Resumo:
JUSTIFICATIVA E OBJETIVOS: Não existem estudos que relatem as repercussões renais determinadas pela injeção de doses elevadas de clonidina no espaço peridural. O objetivo do estudo foi avaliar os efeitos hemodinâmicos e renais determinados pela injeção de doses elevadas de clonidina no espaço peridural do cão. MÉTODO: Vinte animais anestesiados com tiopental sódico e fentanil foram distribuídos aleatoriamente e de forma duplamente encoberta em dois grupos: Grupo 1 ou placebo (n = 10), que recebeu 0,2 mL.kg-1 de solução fisiológica, e Grupo 2 ou clonidina (n = 10), que recebeu 0,2 mL.kg-1 de uma solução contendo 50 µg.mL-1 de clonidina, no espaço peridural. Foram avaliados os seguintes parâmetros hemodinâmicos: freqüência cardíaca (FC): bat.min-1; pressão arterial média (PAM): mmHg; pressão da artéria pulmonar ocluida (PAOP): mmHg; débito cardíaco (DC): L.min-1; volume sistólico (VS): mL; também, os seguintes parâmetros da função renal foram avaliados: fluxo sangüíneo renal (FSR): mL.min-1; resistência vascular renal (RVR): mmHg.mL-1.min; volume urinário minuto (VUM): mL.min-1; depuração de creatinina (D Cr): mL.min-1; depuração de para-aminohipurato (D PAH): mL.min-1; fração de filtração (FF); depuração de sódio (D Na): mL.min-1; depuração de potássio (D K): mL.min-1; excreção fracionária de sódio (EF Na): %; excreção urinária de sódio (U NaV): µEq.min-1; excreção urinária de potássio (U K V): µEq.min-1. O experimento consistiu em três momentos de 20 minutos cada. Os dados foram coletados aos 10 minutos de cada momento e a diurese, no início e no final de cada momento. Ao término de M1, a clonidina ou a solução fisiológica foi administrada no espaço peridural. Após período de 20 minutos iniciou-se M2 e, em seguida, M3. RESULTADOS: A clonidina na dose de 10 µg.kg-1 no espaço peridural do cão promoveu alterações significativas, com diminuições da freqüência cardíaca e do débito cardíaco e aumento da relação depuração de para-aminohipurato de sódio/débito cardíaco. CONCLUSÕES: Nas condições realizadas e nas doses empregadas, pode-se concluir que a clonidina não promoveu alteração da função renal, mas diminuiu valores hemodinâmicos (freqüência e débito cardíaco).
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
OBJETIVO: Comparar a reinervação muscular com enxerto de nervo em um e dois tempos operatórios, utilizando a neurorrafia término-lateral (NTL) sem lesão do nervo doador. MÉTODOS: Vinte ratos foram distribuídos em quatro grupos. O grupo 1 (G1), um estágio, recebeu o enxerto que foi suturado ao nervo tibial (NT), por meio de NTL, e seu coto livre foi suturado por NTL ao coto distal do nervo peroneal (NP), seccionado a um centímetro do NT, na mesma cirurgia. O grupo 2 (G2), dois estágios, recebeu o enxerto de nervo na primeira cirurgia, como já descrito. Dois meses depois, na segunda cirurgia, o NP foi seccionado e seu coto distal ligado ao coto distal do enxerto como em G1. O grupo controle de normalidade (Gn) recebeu o enxerto da mesma forma, apenas. E o grupo controle de denervação (Gd), além de receber o enxerto, teve o NP seccionado e seus cotos sepultados na musculatura adjacente, com a finalidade de denervar o músculo tibial cranial (MTC), alvo deste estudo. Os parâmetros utilizados para avaliar a reinervação do MTC foram massa muscular, diâmetro mínimo da fibra muscular e área. RESULTADOS: O grupo G2 apresentou superioridade (p<0,0001) em relação ao G1 na massa do MTC, no diâmetro mínimo e na área das fibras musculares. Na comparação entre os quatro grupos, estes mesmos parâmetros tiveram sua expressão máxima em Gn e mínima em Gd, como era esperado. CONCLUSÃO: A reinervação muscular em dois estágios apresenta melhor resultado quando comparada à técnica em um tempo.
Resumo:
The objective of this study was to investigate the effects of exposure to tobacco smoke (ETS) in rats that were or were not supplemented with dietary beta-carotene (BC), on ventricular remodeling and survival after myocardial infarction (MI). Rats (n = 189) were allocated to 4 groups: the control group, n = 45; group BC administered 500 mg/kg diet, n = 49, BC supplemented rats; group ETS, n = 55, rats exposed to tobacco smoke; and group BC+ETS, n = 40. Wistar rats weighing 100 g were administered one of the treatments until they weighed 200 to 250 g (similar to 5 wk). The ETS rats were exposed to cigarette smoke for 30 min 4 times/d, in a chamber connected to a smoking device. After reaching a weight of 200-250 g, rats were subjected to experimental MI (coronary artery occlusion) and mortality rates were determined over the next 105 d. In addition, echocardiographic, isolated heart, morphometrical, and biochemical studies were performed. Mortality data were tested using Kaplan-Meyer curves and other data by 2-way ANOVA. Survival rates were greater in the ETS group (58.2%) than in the control (33.3%) (P = 0.001) and BC+ETS rats (30.0%) (P = 0.007). The groups did not differ in the other comparisons. Left ventricular end-diastolic diameter normalized to body weight was greater and maximal systolic pressures were lower in the ETS groups than in non-ETS groups. Previous exposure to tobacco smoke induced a process of cardiac remodeling after MI. There is a paradoxical protector effect with tobacco smoke exposure, characterized by lower mortality, which is offset by BC supplementation.