902 resultados para electrical energy storage
Resumo:
In the framework of the micro-CHP (Combined Heat and Power) energy systems and the Distributed Generation (GD) concept, an Integrated Energy System (IES) able to meet the energy and thermal requirements of specific users, using different types of fuel to feed several micro-CHP energy sources, with the integration of electric generators of renewable energy sources (RES), electrical and thermal storage systems and the control system was conceived and built. A 5 kWel Polymer Electrolyte Membrane Fuel Cell (PEMFC) has been studied. Using experimental data obtained from various measurement campaign, the electrical and CHP PEMFC system performance have been determinate. The analysis of the effect of the water management of the anodic exhaust at variable FC loads has been carried out, and the purge process programming logic was optimized, leading also to the determination of the optimal flooding times by varying the AC FC power delivered by the cell. Furthermore, the degradation mechanisms of the PEMFC system, in particular due to the flooding of the anodic side, have been assessed using an algorithm that considers the FC like a black box, and it is able to determine the amount of not-reacted H2 and, therefore, the causes which produce that. Using experimental data that cover a two-year time span, the ageing suffered by the FC system has been tested and analyzed.
Resumo:
La presente dissertazione investiga la possibilità di ottimizzare l’uso di energia a bordo di una nave per trasporto di prodotti chimici e petrolchimici. Il software sviluppato per questo studio può essere adattato a qualsiasi tipo di nave. Tale foglio di calcolo fornisce la metodologia per stimare vantaggi e miglioramenti energetici, con accuratezza direttamente proporzionale ai dati disponibili sulla configurazione del sistema energetico e sui dispositivi installati a bordo. Lo studio si basa su differenti fasi che permettono la semplificazione del lavoro; nell’introduzione sono indicati i dati necessari per svolgere un’accurata analisi ed è presentata la metodologia adottata. Inizialmente è fornita una spiegazione sul layout dell’impianto, sulle sue caratteristiche e sui principali dispositivi installati a bordo. Vengono dunque trattati separatamente i principali carichi, meccanico, elettrico e termico. In seguito si procede con una selezione delle principali fasi operative della nave: è seguito tale approccio in modo da comprendere meglio la ripartizione della richiesta di potenza a bordo della nave e il suo sfruttamento. Successivamente è svolto un controllo sul dimensionamento del sistema elettrico: ciò aiuta a comprendere se la potenza stimata dai progettisti sia assimilabile a quella effettivamente richiesta sulla nave. Si ottengono in seguito curve di carico meccanico, elettrico e termico in funzione del tempo per tutte le fasi operative considerate: tramite l’uso del software Visual Basic Application (VBA) vengono creati i profili di carico che possono essere gestiti nella successiva fase di ottimizzazione. L’ottimizzazione rappresenta il cuore di questo studio; i profili di potenza ottenuti dalla precedente fase sono gestiti in modo da conseguire un sistema che sia in grado di fornire potenza alla nave nel miglior modo possibile da un punto di vista energetico. Il sistema energetico della nave è modellato e ottimizzato mantenendo lo status quo dei dispositivi di bordo, per i quali sono considerate le configurazioni di “Load following”, “two shifts” e “minimal”. Una successiva investigazione riguarda l’installazione a bordo di un sistema di accumulo di energia termica, così da migliorare lo sfruttamento dell’energia disponibile. Infine, nella conclusione, sono messi a confronto i reali consumi della nave con i risultati ottenuti con e senza l’introduzione del sistema di accumulo termico. Attraverso la configurazione “minimal” è possibile risparmiare circa l’1,49% dell’energia totale consumata durante un anno di attività; tale risparmio è completamente gratuito poiché può essere raggiunto seguendo alcune semplici regole nella gestione dell’energia a bordo. L’introduzione di un sistema di accumulo termico incrementa il risparmio totale fino al 4,67% con un serbatoio in grado di accumulare 110000 kWh di energia termica; tuttavia, in questo caso, è necessario sostenere il costo di installazione del serbatoio. Vengono quindi dibattuti aspetti economici e ambientali in modo da spiegare e rendere chiari i vantaggi che si possono ottenere con l’applicazione di questo studio, in termini di denaro e riduzione di emissioni in atmosfera.
Resumo:
Die vorliegende Arbeit befasst sich mit der Synthese und Charakterisierung von Polymeren mit redox-funktionalen Phenothiazin-Seitenketten. Phenothiazin und seine Derivate sind kleine Redoxeinheiten, deren reversibles Redoxverhalten mit electrochromen Eigenschaften verbunden ist. Das besondere an Phenothiazine ist die Bildung von stabilen Radikalkationen im oxidierten Zustand. Daher können Phenothiazine als bistabile Moleküle agieren und zwischen zwei stabilen Redoxzuständen wechseln. Dieser Schaltprozess geht gleichzeitig mit einer Farbveränderung an her.rnrnIm Rahmen dieser Arbeit wird die Synthese neuartiger Phenothiazin-Polymere mittels radikalischer Polymerisation beschrieben. Phenothiazin-Derivate wurden kovalent an aliphatischen und aromatischen Polymerketten gebunden. Dies erfolgte über zwei unterschiedlichen synthetischen Routen. Die erste Route beinhaltet den Einsatz von Vinyl-Monomeren mit Phenothiazin Funktionalität zur direkten Polymerisation. Die zweite Route verwendet Amin modifizierte Phenothiazin-Derivate zur Funktionalisierung von Polymeren mit Aktivester-Seitenketten in einer polymeranalogen Reaktion. rnrnPolymere mit redox-funktionalen Phenothiazin-Seitenketten sind aufgrund ihrer Elektron-Donor-Eigenschaften geeignete Kandidaten für die Verwendung als Kathodenmaterialien. Zur Überprüfung ihrer Eignung wurden Phenothiazin-Polymere als Elektrodenmaterialien in Lithium-Batteriezellen eingesetzt. Die verwendeten Polymere wiesen gute Kapazitätswerte von circa 50-90 Ah/kg sowie schnelle Aufladezeiten in der Batteriezelle auf. Besonders die Aufladezeiten sind 5-10 mal höher als konventionelle Lithium-Batterien. Im Hinblick auf Anzahl der Lade- und Entladezyklen, erzielten die Polymere gute Werte in den Langzeit-Stabilitätstests. Insgesamt überstehen die Polymere 500 Ladezyklen mit geringen Veränderungen der Anfangswerte bezüglich Ladezeiten und -kapazitäten. Die Langzeit-Stabilität hängt unmittelbar mit der Radikalstabilität zusammen. Eine Stabilisierung der Radikalkationen gelang durch die Verlängerung der Seitenkette am Stickstoffatom des Phenothiazins und der Polymerhauptkette. Eine derartige Alkyl-Substitution erhöht die Radikalstabilität durch verstärkte Wechselwirkung mit dem aromatischen Ring und verbessert somit die Batterieleistung hinsichtlich der Stabilität gegenüber Lade- und Entladezyklen. rnrnDes Weiteren wurde die praktische Anwendung von bistabilen Phenothiazin-Polymeren als Speichermedium für hohe Datendichten untersucht. Dazu wurden dünne Filme des Polymers auf leitfähigen Substraten elektrochemisch oxidiert. Die elektrochemische Oxidation erfolgte mittels Rasterkraftmikroskopie in Kombination mit leitfähigen Mikroskopspitzen. Mittels dieser Technik gelang es, die Oberfläche des Polymers im nanoskaligen Bereich zu oxidieren und somit die lokale Leitfähigkeit zu verändern. Damit konnten unterschiedlich große Muster lithographisch beschrieben und aufgrund der Veränderung ihrer Leitfähigkeit detektiert werden. Der Schreibprozess führte nur zu einer Veränderung der lokalen Leitfähigkeit ohne die topographische Beschaffenheit des Polymerfilms zu beeinflussen. Außerdem erwiesen sich die Muster als besonders stabil sowohl mechanisch als auch über die Zeit.rnrnZum Schluss wurden neue Synthesestrategien entwickelt um mechanisch stabile als auch redox-funktionale Oberflächen zu produzieren. Mit Hilfe der oberflächen-initiierten Atomtransfer-Radikalpolymerisation wurden gepfropfte Polymerbürsten mit redox-funktionalen Phenothiazin-Seitenketten hergestellt und mittels Röntgenmethoden und Rasterkraftmikroskopie analysiert. Eine der Synthesestrategien geht von gepfropften Aktivesterbürsten aus, die anschließend in einem nachfolgenden Schritt mit redox-funktionalen Gruppen modifiziert werden können. Diese Vorgehensweise ist besonders vielversprechend und erlaubt es unterschiedliche funktionelle Gruppen an den Aktivesterbürsten zu verankern. Damit können durch Verwendung von vernetzenden Gruppen neben den Redoxeigenschaften, die mechanische Stabilität solcher Polymerfilme optimiert werden. rn rn
Resumo:
Bandlaufwerke waren bisher die vorherrschende Technologie, um die anfallenden Datenmengen in Archivsystemen zu speichern. Mit Zugriffsmustern, die immer aktiver werden, und Speichermedien wie Festplatten die kostenmäßig aufholen, muss die Architektur vor Speichersystemen zur Archivierung neu überdacht werden. Zuverlässigkeit, Integrität und Haltbarkeit sind die Haupteigenschaften der digitalen Archivierung. Allerdings nimmt auch die Zugriffsgeschwindigkeit einen erhöhten Stellenwert ein, wenn aktive Archive ihre gesamten Inhalte für den direkten Zugriff bereitstellen. Ein band-basiertes System kann die hierfür benötigte Parallelität, Latenz und Durchsatz nicht liefern, was in der Regel durch festplattenbasierte Systeme als Zwischenspeicher kompensiert wird.rnIn dieser Arbeit untersuchen wir die Herausforderungen und Möglichkeiten ein festplattenbasiertes Speichersystem zu entwickeln, das auf eine hohe Zuverlässigkeit und Energieeffizienz zielt und das sich sowohl für aktive als auch für kalte Archivumgebungen eignet. Zuerst analysieren wir die Speichersysteme und Zugriffsmuster eines großen digitalen Archivs und präsentieren damit ein mögliches Einsatzgebiet für unsere Architektur. Daraufhin stellen wir Mechanismen vor um die Zuverlässigkeit einer einzelnen Festplatte zu verbessern und präsentieren sowie evaluieren einen neuen, energieeffizienten, zwei- dimensionalen RAID Ansatz der für „Schreibe ein Mal, lese mehrfach“ Zugriffe optimiert ist. Letztlich stellen wir Protokollierungs- und Zwischenspeichermechanismen vor, die die zugrundeliegenden Ziele unterstützen und evaluieren das RAID System in einer Dateisystemumgebung.
Resumo:
The rising concerns about environmental pollution and global warming have facilitated research interest in hydrogen energy as an alternative energy source. To apply hydrogen for transportations, several issues have to be solved, within which hydrogen storage is the most critical problem. Lots of materials and devices have been developed; however, none is able to meet the DOE storage target. The primary issue for hydrogen physisorption is a weak interaction between hydrogen and the surface of solid materials, resulting negligible adsorption at room temperature. To solve this issue, there is a need to increase the interaction between the hydrogen molecules and adsorbent surface. In this study, intrinsic electric dipole is investigated to enhance the adsorption energy. The results from the computer simulation of single ionic compounds with hydrogen molecules to form hydrogen clusters showed that electrical charge of substances plays an important role in generation of attractive interaction with hydrogen molecules. In order to further examine the effects of static interaction on hydrogen adsorption, activated carbon with a large surface area was impregnated with various ionic salts including LiCl, NaCl, KCl, KBr, and NiCl and their performance for hydrogen storage was evaluated by using a volumetric method. Corresponding computer simulations have been carried out by using DFT (Density Functional Theory) method combined with point charge arrays. Both experimental and computational results prove that the adsorption capacity of hydrogen and its interaction with the solid materials increased with electrical dipole moment. Besides the intrinsic dipole, an externally applied electric field could be another means to enhance hydrogen adsorption. Hydrogen adsorption under an applied electric field was examined by using porous nickel foil as electrodes. Electrical signals showed that adsorption capacity increased with the increasing of gas pressure and external electric voltage. Direct measurement of the amount of hydrogen adsorption was also carried out with porous nickel oxides and magnesium oxides using the piezoelectric material PMN-PT as the charge supplier due to the pressure. The adsorption enhancement from the PMN-PT generated charges is obvious at hydrogen pressure between 0 and 60 bars, where the hydrogen uptake is increased at about 35% for nickel oxide and 25% for magnesium oxide. Computer simulation reveals that under the external electric field, the electron cloud of hydrogen molecules is pulled over to the adsorbent site and can overlap with the adsorbent electrons, which in turn enhances the adsorption energy Experiments were also carried out to examine the effects of hydrogen spillover with charge induced enhancement. The results show that the overall storage capacity in nickel oxide increased remarkably by a factor of 4.
Resumo:
Energy efficiency has become an important research topic in intralogistics. Especially in this field the focus is placed on automated storage and retrieval systems (AS/RS) utilizing stacker cranes as these systems are widespread and consume a significant portion of the total energy demand of intralogistical systems. Numerical simulation models were developed to calculate the energy demand rather precisely for discrete single and dual command cycles. Unfortunately these simulation models are not suitable to perform fast calculations to determine a mean energy demand value of a complete storage aisle. For this purpose analytical approaches would be more convenient but until now analytical approaches only deliver results for certain configurations. In particular, for commonly used stacker cranes equipped with an intermediate circuit connection within their drive configuration there is no analytical approach available to calculate the mean energy demand. This article should address this research gap and present a calculation approach which enables planners to quickly calculate the energy demand of these systems.
Resumo:
In this paper we present a heterogeneous collaborative sensor network for electrical management in the residential sector. Improving demand-side management is very important in distributed energy generation applications. Sensing and control are the foundations of the “Smart Grid” which is the future of large-scale energy management. The system presented in this paper has been developed on a self-sufficient solar house called “MagicBox” equipped with grid connection, PV generation, lead-acid batteries, controllable appliances and smart metering. Therefore, there is a large number of energy variables to be monitored that allow us to precisely manage the energy performance of the house by means of collaborative sensors. The experimental results, performed on a real house, demonstrate the feasibility of the proposed collaborative system to reduce the consumption of electrical power and to increase energy efficiency.
Resumo:
Massive integration of renewable energy sources in electrical power systems of remote islands is a subject of current interest. The increasing cost of fossil fuels, transport costs to isolated sites and environmental concerns constitute a serious drawback to the use of conventional fossil fuel plants. In a weak electrical grid, as it is typical on an island, if a large amount of conventional generation is substituted by renewable energy sources, power system safety and stability can be compromised, in the case of large grid disturbances. In this work, a model for transient stability analysis of an isolated electrical grid exclusively fed from a combination of renewable energy sources has been studied. This new generation model will be installed in El Hierro Island, in Spain. Additionally, an operation strategy to coordinate the generation units (wind, hydro) is also established. Attention is given to the assessment of inertial energy and reactive current to guarantee power system stability against large disturbances. The effectiveness of the proposed strategy is shown by means of simulation results.
Neural network controller for active demand side management with PV energy in the residential sector
Resumo:
In this paper, we describe the development of a control system for Demand-Side Management in the residential sector with Distributed Generation. The electrical system under study incorporates local PV energy generation, an electricity storage system, connection to the grid and a home automation system. The distributed control system is composed of two modules: a scheduler and a coordinator, both implemented with neural networks. The control system enhances the local energy performance, scheduling the tasks demanded by the user and maximizing the use of local generation.
Resumo:
For the decades to come can be foreseen that electricity and water will keep be playing a key role in the countries development, both can be considered the most important energy vectors and its control can be crucial for governments, companies and leaders in general. Energy is essential for all human activities and its availability is critical to economic and social development. In particular, electricity, a form of energy, is required to produce goods, to provide medical assistance and basic civic services in education, to assure availability of clean water, to create conducive environment for prosperity and improvement, and to keep an acceptable quality of life. The way in which electricity is generated from different resources varies through the different countries. Nuclear energy controlled within reactors to steam production, gas, fuel-oil and coal fired in power stations, water, solar and wind energy among others are employed, sometimes not very efficiently, to produce electricity. The so call energy mix of an individual country is formed up by the contribution of each resource or form of energy to the electricity generation market of the so country. During the last decade the establishment of proper energy mixes for countries has gained much importance, and energy drivers should enforce long term plans and policies. Hints, reports and guides giving tracks on energy resources contribution are been developed by noticeable organisations like the IEA (International Energy Agency) or the IAEA (International Atomic Energy Agency) and the WEC (World Energy Council). This paper evaluates energy issues the market and countries are facing today regarding energy mix scheduling and panorama. This paper revises and seeks to improve methodology available that are applicable on energy mix plan definition. Key Factors are identified, established and assessed through this paper for the common implementation, the themes driving the future energy mix methodology proposal. Those have a clear influence and are closely related to future environmental policies. Key Factors take into consideration sustainability, energy security, social and economic growth, climate change, air quality and social stability. The strength of the Key Factors application on energy system planning to different countries is contingent on country resources, location, electricity demand and electricity generation industry, technology available, economic situation and prospects, energy policy and regulation
Resumo:
The need of new systems for the storage and conversion of renewable energy sources is fueling the research in supercapacitors. In this work, we propose a low temperature route for the synthesis of electrodes for these supercapacitors: electrodeposition of a transition metal hydroxide–Ni(OH)2 on a graphene foam. This electrode combines the superior mechanical and electrical properties of graphene, the large specific surface area of the foam and the large pseudocapacitance of Ni(OH)2. We report a specific capacitance up to 900 F/g as well as specific power and energy comparable to active carbon electrodes. These electrodes are potential candidates for their use in energy applications.
Resumo:
This paper studies the impact that different approaches of modeling the real-time use of the secondary regulation reserves have in the joint energy and reserve hourly scheduling of a price-taker pumped-storage hydropower plant. The unexpected imbalance costs due to the error between the forecasted real-time use of the reserves and the actual value are also studied and evaluated for the different approaches. The proposed methodology is applied to a daily-cycle and closed-loop pumped-storage hydropower plant. Preliminary results show that the deviations in the water volume at the end of the day are important when the percentage of the real-time use of reserves is unknown in advance, and also that the total income in all approaches after correcting these deviations is significantly lower than the maximum theoretical income.