1000 resultados para elaboraci??n de tests


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This Thesis project is a part of the research conducted in Solar industry. ABSOLICON Solar Concentrator AB has invented and started production of the prospective solar concentrated system Absolicon X10. The aims of this Thesis project are designing, assembling, calibrating and putting in operation the automatic measurement system intended to evaluate distribution of density of solar radiation in the focal line of the concentrated parabolic reflectors and to measure radiation from the artificial source of light being a calibration-testing tool.On the basis of the requirements of the company’s administration and needs of designing the concentrated reflectors the operation conditions for the Sun-Walker were formulated. As the first step, the complex design of the whole system was made and division on the parts was specified. After the preliminary conducted simulation of the functions and operation conditions of the all parts were formulated.As the next steps, the detailed design of all the parts was made. Most components were ordered from respective companies. Some of the mechanical components were made in the workshop of the company. All parts of the Sun-Walker were assembled and tested. The software part, which controls the Sun-Walker work and conducts measurements of solar irradiation, was created on the LabVIEW basis. To tune and test the software part, the special simulator was designed and assembled.When all parts were assembled in the complete system, the Sun-Walker was tested, calibrated and tuned.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Many companies implement a modular architecture to support the need to create more variants with less effort. Although the modular architecture has many benefits, the tests to detect any defects become a major challenge. However, a modular architecture with defined functional elements seems beneficial to test at module level, so called MPV (Module Property Verification). This paper presents studies from 29 companies with the purpose of showing trends in the occurrence of defects and how these can support the MPV.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective To investigate if a home environment test battery can be used to measure effects of Parkinson’s disease (PD) treatment intervention and disease progression. Background Seventy-seven patients diagnosed with advanced PD were recruited in an open longitudinal 36-month study at 10 clinics in Sweden and Norway; 40 of them were treated with levodopa-carbidopa intestinal gel (LCIG) and 37 patients were candidates for switching from oral PD treatment to LCIG. They utilized a mobile device test battery, consisting of self-assessments of symptoms and objective measures of motor function through a set of fine motor tests (tapping and spiral drawings), in their homes. Both the LCIG-naïve and LCIG-non-naïve patients used the test battery four times per day during week-long test periods. Methods Assessments The LCIG-naïve patients used the test battery at baseline (before LCIG), month 0 (first visit; at least 3 months after intraduodenal LCIG), and thereafter quarterly for the first year and biannually for the second and third years. The LCIG-non-naïve patients used the test battery from the first visit, i.e. month 0. Out of the 77 patients, only 65 utilized the test battery; 35 were LCIG-non-naïve and 30 LCIG-naïve. In 20 of the LCIG-naïve patients, assessments with the test battery were available during oral treatment and at least one test period after having started infusion treatment. Three LCIG-naïve patients did not use the test battery at baseline but had at least one test period of assessments thereafter. Hence, n=23 in the LCIG-naïve group. In total, symptom assessments in the full sample (including both patient groups) were collected during 379 test periods and 10079 test occasions. For 369 of these test periods, clinical assessments including UPDRS and PDQ-39 were performed in afternoons at the start of the test periods. The repeated measurements of the test battery were processed and summarized into scores representing patients’ symptom severities over a test period, using statistical methods. Six conceptual dimensions were defined; four subjectively-reported: ‘walking’, ‘satisfied’, ‘dyskinesia’, and ‘off’ and two objectively-measured: ‘tapping’ and ‘spiral’. In addition, an ‘overall test score’ (OTS) was defined to represent the global health condition of the patient during a test period. Statistical methods Change in the test battery scores over time, that is at baseline and follow-up test periods, was assessed with linear mixed-effects models with patient ID as a random effect and test period as a fixed effect of interest. The within-patient variability of OTS was assessed using intra-class correlation coefficient (ICC), for the two patient groups. Correlations between clinical rating scores and test battery scores were assessed using Spearman’s rank correlations (rho). Results In LCIG-naïve patients, mean OTS compared to baseline was significantly improved from the first test period on LCIG treatment until month 24. However, there were no significant changes in mean OTS scores of LCIG-non-naïve patients, except for worse mean OTS at month 36 (p<0.01, n=16). The mean scores of all subjectively-reported dimensions improved significantly throughout the course of the study, except ‘walking’ at month 36 (p=0.41, n=4). However, there were no significant differences in mean scores of objectively-measured dimensions between baseline and other test periods, except improved ‘tapping’ at month 6 and month 36, and ‘spiral’ at month 3 (p<0.05). The LCIG-naïve patients had a higher within-subject variability in their OTS scores (ICC=0.67) compared to LCIG-non-naïve patients (ICC=0.71). The OTS correlated adequately with total UPDRS (rho=0.59) and total PDQ-39 (rho=0.59). Conclusions In this 3-year follow-up study of advanced PD patients treated with LCIG we found that it is possible to monitor PD progression over time using a home environment test battery. The significant improvements in the mean OTS scores indicate that the test battery is able to measure functional improvement with LCIG sustained over at least 24 months.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We have estimated the reliability of performance in a commonly employed exercise test consisting of repeated sprints on a cycle ergometer. Eight recreationally active young men completed a practice trial and three more trials at 3- to 6-day intervals. Each trial consisted of two bouts of 30-s maximal-effort cycling on an electromagnetically braked cycle ergometer; the bouts were separated by 4 min of rest. The typical (standard) errors of measurement for peak and mean power between trials 2 to 4 were 2.5 and 1.7% respectively for the first bout and 1.9 and 1.8% for the second bout. These errors are substantially less than those in previous reliability studies of single 30-s sprint tests, probably because of differences in quality of ergometer. The typical errors for the difference between bouts (i.e., fatigue) for peak power and mean power were 3.0 and 2.5%, respectively. Typical errors for the average of the two bouts were 1.6 and 1.2% for peak and mean power respectively, which are small enough to give adequate precision for moderate treatment effects in studies with modest sample sizes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A compression test with rotating dies was employed to estimate the friction factor between aluminum samples and steel tooling during large plastic deformations. A cylindrical workpiece was compressed under dry and cold conditions. The magnitudes of torque and normal force were measured and
the average friction factor was calculated using the Coulomb friction law. It was found that under certain conditions the friction increased with increasing angular velocity of the die. This finding led to the conclusion that the choice of die rotation speed is important in interpreting the results from the twist compression test.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper studies the effect of the normal distribution assumption on the power and size of the sign test, Wilcoxon's signed rank test and the t-test when used in one-sample location problems. Power functions for these tests under various skewness and kurtosis conditions are produced for several sample sizes from simulated data using the g-and-k distribution of MacGillivray and Cannon.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The influence of low-strain deformation behavior on curl and springback in advanced high strength steels (AHSS) was assessed using a bend-under-tension test. The effect of yielding behavior on curl and springback was examined by heat-treating two dual-phase steels to induce yield point elongation, while keeping a relatively constant tensile strength and a constant sheet thickness. A dual-phase and TRIP steel with similar initial thickness and tensile strengths were also examined to investigate the effect of work-hardening on curl and springback. It is shown that while current understanding limits prediction of curl and springback in bending under tension using only the initial sheet thickness and tensile strength, both the yielding and work-hardening behavior can affect the results. Explanations for these effects are proposed in terms of the discontinuous yielding and flow stress in the materials.


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose – There are several studies that investigate evidence for mean reversion in stock prices. However, there is no consensus as to whether stock prices are mean reverting or random walk (unit root) processes. The goal of this paper is to re-examine mean reversion in stock prices.
Design/methodology/approach – The authors use five different panel unit root tests, namely the Im, Pesaran and Shin t-bar test statistic, the Levin and Lin test, the Im, Lee, and Tieslau Lagrangian multiplier test statistic, the seemingly unrelated regression test, and the multivariate augmented Dickey Fuller test advocated by Taylor and Sarno.
Findings – The main finding is that there is no mean reversion of stock prices, consistent with the efficient market hypothesis.
Research limitations/implications – One issue not considered by this study is the role of structural breaks. It may be the case that the efficient market hypothesis is contingent on structural breaks in stock prices. Future studies should model structural breaks.
Practical implications – The findings have implications for econometric modelling, in particular forecasting.
Originality/value – This paper adds to the scarce literature on the mean reverting property of stock prices based on panel data; thus, it should be useful for researchers.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: To evaluate whether the introduction of a national, co-ordinated screening program using the faecal occult blood test represents 'value-for-money' from the perspective of the Australian Government as third-party funder.  Methods: The annual equivalent costs and consequences of a   biennial screening program in 'steady-state' operation were estimated for the Australian population using 1996 as the reference year. Disability-adjusted life years (DALYs) and the years of life lost (YLLs) averted, and the health service costs were modelled, based on the epidemiology and the costs of colorectal cancer in Australia together with the mortality reduction achieved in randomised controlled trials. Uncertainty in the model was examined using Monte Carlo simulation methods. Results: We estimate a minimum or 'base program' of screening those aged 55 to 69 years could avert 250 deaths per annum (95% uncertainty interval 99–400), at a gross cost of $A55 million (95% UI $A46 million to $A96 million) and a gross incremental cost-effectiveness ratio of $A17,000/DALY (95% UI $A13,000/DALY to $A52,000/DALY). Extending the program to include 70 to 74-year-olds is a more effective option (cheaper and higher health gain) than including the 50 to 54-year-olds. Conclusions: The findings of this study support the case for a national program directed at the 55 to 69-year-old age group with extension to 70 to 74-year-olds if there are sufficient resources. The pilot tests recently announced in Australia provide an important opportunity to consider the age range for screening and the sources of uncertainty, identified in the modelled evaluation, to assist decisions on implementing a full national program.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: To investigate the reliability and validity of five squat-based loading tests that are clinically appropriate for jumper's knee. The loading tests were step up, double leg squat, double leg squat on a 25-degree decline (decline squat), single leg decline squat, and decline hop. Design: Cross-sectional controlled cohort. Subjects without knee pain comprised controls, those with extensor tendon pain comprised the jumper's knee group. Setting: Institutional athlete study group in Australia. Participants: Fifty-six elite adolescent basketball players participated in this study, thirteen comprised the jumper's knee group, fifteen athletes formed a control group. Intervention: Each subject performed each loading test for baseline and reliability data on the first testing day. Subjects then performed three days of intensive (6 h daily) basketball training, after which each loading test was reexamined. Main outcome measures: Eleven point interval scale for pain. Results: The tests that best detected a change in pain due to intensive workload were the single leg decline squat and single leg decline hop. This study found that decline tests have better discriminative ability than the standard squat to detect change in jumper's knee pain due to intensive training. The typical error for these tests ranged from 0.3 to 0.5, however, caution should be exercised in the interpretation of these reliability figures due to relatively low scores. Conclusions: The single leg decline squat is recommended in the physical assessment of adolescent jumper's knee. The decline squat was selected as the best clinical test over the decline hop because it was easier to standardise performance.