967 resultados para district heat energy production


Relevância:

40.00% 40.00%

Publicador:

Resumo:

Transplantation of pancreatic islets is efficient in improving the metabolic control and quality of life and in preventing severe hypoglycemia in patients with brittle type I diabetes mellitus. More accurate methods to assess islet viability would be extremely useful in designing target interventions for islet cytoprorection and in reducing the number of islets required to achieve insulin independence. Here we report on an application of calorimetry to evaluate the metabolic response of pancreatic islets to glucose stimulation. A significant increase in metabolic heat was produced by islet samples when consecutively subjected to 2.8 and 16.3 mmol L-1 glucose. Under these glucose concentrations, 1000 islets released average heat values of 9.16 +/- 0.71 mJ and 14.90 +/- 1.21 mJ over 50 min, respectively. Additionally, the glucose stimulation indexes were 1.67 +/- 0.30 for insulin. 1.72 +/- 0.13 for heat and 2.91 +/- 0.50 for lactate, raising the important possibility of substituting the secreted insulin index/ratio by the index/ratio of the heat released in the evaluation of Langerhans islets viability for transplantation. Altogether, Our results demonstrate the applicability of calorimetry to assess the quality of isolated pancreatic islets and to study vital islet functions. (c) 2008 Published by Elsevier B.V.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

As a first step in assessing the potential of thermal energy storage in Swedish buildings, the current situation of the Swedish building stock and different storage methods are discussed in this paper. Overall, many buildings are from the 1960’s or earlier having a relatively high energy demand, creating opportunities for large energy savings. The major means of heating are electricity for detached houses and district heating for multi dwelling houses and premises. Cooling needs are relatively low but steadily increasing, emphasizing the need to consider energy storage for both heat and cold. The thermal mass of a building is important for passive storage of thermal energy but this has not been considered much when constructing buildings in Sweden. Instead, common ways of storing thermal energy in Swedish buildings today is in water storage tanks or in the ground using boreholes, while latent thermal energy storage is still very uncommon.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

This paper focuses on the study of cascade heat pump systems in combination with solar thermal for the production of hot water and space heating in single family houses with relatively high heating demand. The system concept was developed by Ratiotherm GmbH and simulated with TRNSYS 17. The basic cascade system uses the heat pump and solar collectors in parallel operation while a further development is the inclusion of an intermediate store that enables the possibility of serial/parallel operation and the use of low temperature solar heat. Parametric studies in terms of compressor size, refrigerant pair and size of intermediate heat exchanger were carried out for the optimization of the basic system. The system configurations were simulated for the complete year and compared to a reference of a solar thermal system combined with an air source heat pump. The results show ~13% savings in electricity use for all three cascade systems compared to the reference. However, the complexity of the systems is different and thus higher capital costs are expected.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

This paper studies the influence of hydraulics and control of thermal storage in systems combined with solar thermal and heat pump for the production of warm water and space heating in dwellings. A reference air source heat pump system with flat plate collectors connected to a combistore was defined and modeled together with the IEA SHC Task 44 / HPP Annex 38 (T44A38) “Solar and Heat Pump Systems” boundary conditions of Strasbourg climate and SFH45 building. Three and four pipe connections as well as use of internal and external heat exchangers for DHW preparation were investigated as well as sensor height for charging of the DHW zone in the store. The temperature in this zone was varied to ensure the same DHW comfort was achieved in all cases. The results show that the four pipe connection results in 9% improvement in SPF compared to three pipe and that the external heat exchanger for DHW preparation leads to a 2% improvement compared to the reference case. Additionally the sensor height for charging the DHW zone of the store should not be too low, otherwise system performance is adversely affected

Relevância:

40.00% 40.00%

Publicador:

Resumo:

With the building sector accounting for around 40% of the total energy consumption in the EU, energy efficiency in buildings is and continues to be an important issue. Great progress has been made in reducing the energy consumption in new buildings, but the large stock of existing buildings with poor energy performance is probably an even more crucial area of focus. This thesis deals with energy efficiency measures that can be suitable for renovation of existing houses, particularly low-temperature heating systems and ventilation systems with heat recovery. The energy performance, environmental impact and costs are evaluated for a range of system combinations, for small and large houses with various heating demands and for different climates in Europe. The results were derived through simulation with energy calculation tools. Low-temperature heating and air heat recovery were both found to be promising with regard to increasing energy efficiency in European houses. These solutions proved particularly effective in Northern Europe as low-temperature heating and air heat recovery have a greater impact in cold climates and on houses with high heating demands. The performance of heat pumps, both with outdoor air and exhaust air, was seen to improve with low-temperature heating. The choice between an exhaust air heat pump and a ventilation system with heat recovery is likely to depend on case specific conditions, but both choices are more cost-effective and have a lower environmental impact than systems without heat recovery. The advantage of the heat pump is that it can be used all year round, given that it produces DHW. Economic and environmental aspects of energy efficiency measures do not always harmonize. On the one hand, lower costs can sometimes mean larger environmental impact; on the other hand there can be divergence between different environmental aspects. This makes it difficult to define financial subsidies to promote energy efficiency measures.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Nutrition for broilers under high temperatures is extremely important for brazilian broiler chicken industry because the amounts of consumed nutrients and environmental temperature have great effects on bird performance and carcass quality. Among diet nutrients, protein has the highest heat increment; thus, during many years, diets with low protein level were recommended in order to reduce heat production in broiler chickens under heat stress. However, reports have shown that low-protein diets have negative effects on broiler performance when environmental temperature is high, because during heat stress, low food intake associated to a low diet protein induce amino acid deficiencies. Other studies have shown that broilers fed low-protein diets increase their energy requirement for maintenance with higher heat production. Thus, with the growth of broiler industry in tropical areas more challenges need to be faced by the farmers. So, both the ambient and nutritional conditions ought to be well managed to avoid negative effects on poultry production once they can affect the metabolism (body heat production under low temperature and body heat dissipation under high temperature) with consequence on poultry performance (meat and eggs).

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The amount of solar energy made available for the production of a sabid seed varied as a function of the time of the year, the face of the plant in which, the position in the plant on which and the position in the pod in which it was produced.Variation in solar energy availability as a consequence of the time of the year was a direct consequence of latitude. At 21degrees5'22 S the highest amounts of Global Solar Radiation (GSR) reaching the site where the experiment was conducted took place during the months from November through February. During these months there were no marked differences between any two of the amounts of GSR reaching faces North (N), South (S), West (W) East (E). From February through November (period during which the sabid plants of this study flowered and the resulting seeds matured and were harvested) the total GSR's were the lowest and marked differences were found between faces N and S, with face N receiving much more GSR than face S. During that period, faces W and E received practically the same amount of GSR and it was much less than that received by face N and much more than the one received by face S.The amount of biological energy made available for the development of a seed seemed also to vary according to a dry matter partitioning strategy by the plant -the central third of the plant seemed to be the one receiving the highest amounts of energy, followed either by the upper or the lower third of the plant- it was not very clear which third of the plant immediately followed the central one. The partitioning of biological energy at the pod level also seemed to follow a strategy by which the central seeds would be the ones to receive more, followed by the proximal seeds and these by the distal ones.This availability of energy seemed to have a direct effect on seed size, weight and on the percentage of seeds which showed a degree of dormancy deep enough to prevent their germinating under the conditions of a standard germination test.The implications of these results for the improvement of methods for the overcoming of dormancy of sabia seeds are discussed.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

One hundred sixty-two commercial 70-wk-old ISA Brown laying hens, previously subjected to induced molting by feed restriction, were distributed in a completely randomized design with 3 x 3 factorial arrangement (i.e., 3 metabolizable energy levels: 2,850; 2,950, and 3,050 kcal of ME/kg) and 3 protein levels (16, 18, and 20% CP), which totaled 9 treatments with 3 replicates of 6 birds each. Experimental diets were offered to birds after the feed restriction period. Performance and egg quality parameters were evaluated in 14-d intervals from the 4th to 12th weeks after forced molting for a total of 4 evaluation periods. Increases in dietary energy and protein levels did not improve performance or egg quality. The levels of 2,850 kcal of ME and 16% protein were sufficient for laying hens starting the second production cycle without decreasing their performance or egg quality.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

The relationships among avian uncoupling protein (avUCP) mRNA expression, heat production, and thyroid hormone metabolism were investigated in 7-14-day-old broiler chicks (Gallus gallus) exposed to a low temperature (cold-exposed chicks, CE) or a thermoneutral temperature (TN). After 7 days of exposure, CE chicks exhibited higher heat production (+83%, P < 0.01), avUCP mRNA expression (+20%, P < 0.01), and circulating triiodothyronine (T-3) levels (+104%, P = 0.07) for non-statistically different body weights and feed intake between 3 and 7 days of exposure as compared to TN chicks. Plasma thyroxine (T-4) concentration was clearly decreased in CE chicks (-33%, P = 0.06). The lower hepatic inner-ring deiodination activity (-47%) and the higher renal outer-ring deiodination activity (+75%) measured in CE compared to TN chicks could partly account for their higher plasma T3 concentrations. This study describes for the first time the induction of avUCP mRNA expression by low temperature in chickens, as it has been previously shown in ducklings, and supports the possible involvement of avUCP in avian thermogenesis. (C) 2003 Elsevier B.V. (USA). All rights reserved.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

40.00% 40.00%

Publicador:

Resumo:

In this paper, a thermoeconomic functional analysis method based on the Second Law of Thermodynamics and applied to analyze four cogeneration systems is presented. The objective of the developed technique is to minimize the operating costs of the cogeneration plant, namely exergetic production cost (EPC), assuming fixed rates of electricity production and process steam in exergy base. In this study a comparison is made between the same four configurations of part I. The cogeneration system consisting of a gas turbine with a heat recovery steam generator, without supplementary firing, has the lowest EPC. (C) 2004 Published by Elsevier Ltd.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Wood gasification technologies to convert the biomass into fuel gas stand out. on the other hand, producing electrical energy from stationary engine is widely spread, and its application in rural communities where the electrical network doesn't exist is very required. The recovery of exhaust gases (engine) is a possibility that makes the system attractive when compared with the same components used to obtain individual heat such as electric power. This paper presents an energetic alternative to adapt a fixed bed gasifier with a compact cogeneration system in order to cover electrical and thermal demands in a rural area and showing an energy solution for small social communities using renewable fuels. Therefore, an energetic and economical analysis from a cogeneration system producing electric energy, hot and cold water, using wooden gas as fuel from a small-sized gasifier was calculated. The energy balance that includes the energy efficiency (electric generation as well as hot and cold water system; performance coefficient and the heat exchanger, among other items), was calculated. Considering the annual interest rates and the amortization periods, the costs of production of electrical energy, hot and cold water were calculated, taking into account the investment, the operation and the maintenance cost of the equipments. Crown Copyright (C) 2010 Published by Elsevier Ltd. All rights reserved.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)