983 resultados para direct solid sampling


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Because of the various matrices available for forensic investigations, the development of versatile analytical approaches allowing the simultaneous determination of drugs is challenging. The aim of this work was to assess a liquid chromatography-tandem mass spectrometry (LC-MS/MS) platform allowing the rapid quantification of colchicine in body fluids and tissues collected in the context of a fatal overdose. For this purpose, filter paper was used as a sampling support and was associated with an automated 96-well plate extraction performed by the LC autosampler itself. The developed method features a 7-min total run time including automated filter paper extraction (2 min) and chromatographic separation (5 min). The sample preparation was reduced to a minimum regardless of the matrix analyzed. This platform was fully validated for dried blood spots (DBS) in the toxic concentration range of colchicine. The DBS calibration curve was applied successfully to quantification in all other matrices (body fluids and tissues) except for bile, where an excessive matrix effect was found. The distribution of colchicine for a fatal overdose case was reported as follows: peripheral blood, 29 ng/ml; urine, 94 ng/ml; vitreous humour and cerebrospinal fluid, < 5 ng/ml; pericardial fluid, 14 ng/ml; brain, < 5 pg/mg; heart, 121 pg/mg; kidney, 245 pg/mg; and liver, 143 pg/mg. Although filter paper is usually employed for DBS, we report here the extension of this alternative sampling support to the analysis of other body fluids and tissues. The developed platform represents a rapid and versatile approach for drug determination in multiple forensic media.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A simple wipe sampling procedure was developed for the surface contamination determination of ten cytotoxic drugs: cytarabine, gemcitabine, methotrexate, etoposide phosphate, cyclophosphamide, ifosfamide, irinotecan, doxorubicin, epirubicin and vincristine. Wiping was performed using Whatman filter paper on different surfaces such as stainless steel, polypropylene, polystyrol, glass, latex gloves, computer mouse and coated paperboard. Wiping and desorption procedures were investigated: The same solution containing 20% acetonitrile and 0.1% formic acid in water gave the best results. After ultrasonic desorption and then centrifugation, samples were analysed by a validated liquid chromatography coupled to tandem mass spectrometry (LC-MS/MS) in selected reaction monitoring mode. The whole analytical strategy from wipe sampling to LC-MS/MS analysis was evaluated to determine quantitative performance. The lowest limit of quantification of 10 ng per wiping sample (i.e. 0.1 ng cm(-2)) was determined for the ten investigated cytotoxic drugs. Relative standard deviation for intermediate precision was always inferior to 20%. As recovery was dependent on the tested surface for each drug, a correction factor was determined and applied for real samples. The method was then successfully applied at the cytotoxic production unit of the Geneva University Hospitals pharmacy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We propose a restoration algorithm for band limited images that considers irregular(perturbed) sampling, denoising, and deconvolution. We explore the application of a family ofregularizers that allow to control the spectral behavior of the solution combined with the irregular toregular sampling algorithms proposed by H.G. Feichtinger, K. Gr¨ochenig, M. Rauth and T. Strohmer.Moreover, the constraints given by the image acquisition model are incorporated as a set of localconstraints. And the analysis of such constraints leads to an early stopping rule meant to improvethe speed of the algorithm. Finally we present experiments focused on the restoration of satellite images, where the micro-vibrations are responsible of the type of distortions we are considering here. We will compare results of the proposed method with previous methods and show an extension tozoom.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Malignant melanoma, the deadliest form of skin cancer, is characterized by a predominant mutation in the BRAF gene. Drugs that target tumours carrying this mutation have recently entered the clinic. Accordingly, patients are routinely screened for mutations in this gene to determine whether they can benefit from this type of treatment. The current gold standard for mutation screening uses real-time polymerase chain reaction and sequencing methods. Here we show that an assay based on microcantilever arrays can detect the mutation nanomechanically without amplification in total RNA samples isolated from melanoma cells. The assay is based on a BRAF-specific oligonucleotide probe. We detected mutant BRAF at a concentration of 500 pM in a 50-fold excess of the wild-type sequence. The method was able to distinguish melanoma cells carrying the mutation from wild-type cells using as little as 20 ng µl(-1) of RNA material, without prior PCR amplification and use of labels.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Humanized KS-interleukin-2 (huKS-IL2), an immunocytokine with specificity for epithelial cell adhesion molecule (EpCAM), has demonstrated favorable tolerability and immunologic activity as a single agent. METHODS: Phase 1b study in patients with EpCAM-positive advanced solid tumors to determine the maximum tolerated dose (MTD) and safety profile of huKS-IL2 in combination with low-dose cyclophosphamide. Treatment consisted of cyclophosphamide (300 mg/m2 on day 1), and escalating doses of huKS-IL2 (0.5-4.0 mg/m2 IV continuous infusion over 4 hours) on days 2, 3, and 4 of each 21-day cycle. Safety, pharmacokinetic profile, immunogenicity, anti-tumor and biologic activity were evaluated. RESULTS: Twenty-seven patients were treated for up to 6 cycles; 26 were evaluable for response. The MTD of huKS-IL2 in combination with 300 mg/m2 cyclophosphamide was 3.0 mg/m2. At higher doses, myelosuppression was dose-limiting. Transient lymphopenia was the most common grade 3/4 adverse event (AE). Other significant AEs included hypotension, hypophosphatemia, and increase in serum creatinine. All patients recovered from these AEs. The huKS-IL2 exposure was dose-dependent, but not dose-proportional, accumulation was negligible, and elimination half-life and systemic clearance were independent of dose and time. Most patients had a transient immune response to huKS-IL2. Immunologic activity was observed at all doses. Ten patients (38%) had stable disease as best response, lasting for ≥ 4 cycles in 3 patients. CONCLUSION: The combination of huKS-IL2 with low-dose cyclophosphamide was well tolerated. Although no objective responses were observed, the combination showed evidence of immunologic activity and 3 patients showed stable disease for ≥ 4 cycles. TRIAL REGISTRATION: http://NCT00132522.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Solid-phase extraction (SPE) in tandem with dispersive liquid-liquid microextraction (DLLME) has been developed for the determination of mononitrotoluenes (MNTs) in several aquatic samples using gas chromatography-flame ionization (GC-FID) detection system. In the hyphenated SPE-DLLME, initially MNTs were extracted from a large volume of aqueous samples (100 mL) into a 500-mg octadecyl silane (C(18) ) sorbent. After the elution of analytes from the sorbent with acetonitrile, the obtained solution was put under the DLLME procedure, so that the extra preconcentration factors could be achieved. The parameters influencing the extraction efficiency such as breakthrough volume, type and volume of the elution solvent (disperser solvent) and extracting solvent, as well as the salt addition, were studied and optimized. The calibration curves were linear in the range of 0.5-500 μg/L and the limit of detection for all analytes was found to be 0.2 μg/L. The relative standard deviations (for 0.75 μg/L of MNTs) without internal standard varied from 2.0 to 6.4% (n=5). The relative recoveries of the well, river and sea water samples, spiked at the concentration level of 0.75 μg/L of the analytes, were in the range of 85-118%.