936 resultados para diagnostic-accuracy


Relevância:

20.00% 20.00%

Publicador:

Resumo:

A method of measuring the temperature of the fast electrons produced in ultraintense laser-plasma interactions is described by inducing photonuclear reactions, in particular (gamma,n) and (gamma,3n) reactions in tantalum. Analysis of the gamma rays emitted by the daughter nuclei of these reactions using a germanium counter enables a relatively straightforward near real-time temperature measurement to be made. This is especially important for high temperature plasmas where alternative diagnostic techniques are usually difficult and time consuming. This technique can be used while other experiments are being conducted. (C) 2002 American Institute of Physics.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The application of microbeams is providing new insights into the actions of radiation at the cell and tissue levels. So far, this has been achieved exclusively through the use of collimated charged particles. One alternative is to use ultrasoft X rays, focused by X-ray diffractive optics. We have developed a unique facility that uses 0.2-0.8-mm-diameter zone plates to focus ultrasoft X rays to a beam of less than 1 mum diameter. The zone plate images characteristic K-shell X rays of carbon or aluminum, generated by focusing a beam of 5-10 keV electrons onto the appropriate target. By reflecting the X rays off a grazing-incidence mirror, the contaminating bremsstrahlung radiation is reduced to 2%. The focused X rays are then aimed at selected subcellular targets using rapid automated cell-finding and alignment procedures; up to 3000 cells per hour can be irradiated individually using this arrangement. (C) 2001 by Radiation Research Society.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Arterial desaturation as measured using pulse oximetry may not reflect cardiorespiratory disease; other possible causes, including certain drugs, should be sought. Within the literature, examples exist of dapsone-induced methaemoglobinaemia causing diagnostic confusion, particularly where respiratory disease is a feature. Few cases have been reported that demonstrate the potential of relatively low levels of methaemoglobinaemia to upset pulse oximetry readings. We describe three examples of dapsone-induced methaemoglobinaemia emphasising the potential for low-grade methaemoglobinaemia to cause diagnostic confusion. Widespread use of the pulse oximeter indicates this problem may occur more regularly, hence there is a need for increased awareness.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Laser driven proton beams have been used to diagnose transient fields and density perturbations in laser produced plasmas. Grid deflectometry techniques have been applied to proton radiography to obtain precise measurements of proton beam angles caused by electromagnetic fields in laser produced plasmas. Application of proton radiography to laser driven implosions has demonstrated that density conditions in compressed media can be diagnosed with million electron volt protons. This data has shown that proton radiography can provide unique insight into transient electromagnetic fields in super critical density plasmas and provide a density perturbation diagnostics in compressed matter.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The prevailing paradigm for researching sensorimotor synchronisation in humans involves finger tapping and temporal accuracy measures. However, many successful sensorimotor synchronisation actions require not only to be 'in time', but also to be in a predefined spatial position. Reaching this spatial position in many everyday actions often exceeds the average amplitude of a finger movement. The aim of this study is to address how people coordinate their movement to be in the right place at the right time when the scale of the movement varies. Does the scale of the movement and accuracy demands of the movement change the ability to accurately synchronise? To address these questions, a sensorimotor synchronisation task with three different inter-beat intervals, two different movement amplitudes and two different target widths was used. Our experiment demonstrated that people use different timing strategies-employing either a movement strategy (varying movement time) or a waiting strategy (keeping movement time constant) for large-scale movements. Those two strategies were found to be equally successful in terms of temporal accuracy and variability (spread of errors). With longer interval durations (2.5 and 3.5 s), variability of sensorimotor synchronisation performance increased (measured as the spread of errors). Analysing the data using the Vorberg and Wing (Handbook of perception and action. Academic Press, New York, pp 181-262, 1996) model shows a need to develop further existing timing models of sensorimotor synchronisation so that they could apply to large-scale movements, where different movement strategies naturally emerge.