999 resultados para deposição proteica
Resumo:
Pipelines for the transport of crude oil from the production wells to the collecting stations are named production lines . These pipes are subjected to chemical and electrochemical corrosion according to the environment and the type of petroleum transported. Some of these lines, depending upon the composition of the fluid produced, may leak within less than one year of operation due to internal corrosion. This work aims at the development of composite pipes with an external protecting layer of high density polyurethane for use in production lines of onshore oil wells, meeting operational requirements. The pipes were manufactured using glass fibers, epoxy resin, polyester resin, quartz sand and high density polyurethane. The pipes were produced by filament winding with the deposition of high density polyurethane on the external surface and threaded ends (API 15 HR/PM-VII). Three types of pipes were manufactured: glass/epoxy, glass/epoxy with an external polyurethane layer and glass/epoxy with an intermediate layer of glass fiber, polyester, sand and with an external polyurethane layer. The three samples were characterized by Scanning Electronic Microscopy (SEM) and for the determination of constituent content. In addition, the following tests were conducted: hydrostatic test, instant rupture, shorttime failure pressure, Gardner impact, transverse stiffness and axial tension. Field tests were conducted in Mossoró RN (BRAZIL), where 1,677 meters of piping were used. The tests results of the three types of pipes were compared in two events: after two months from manufacturing of the samples and after nine months of field application. The results indicate that the glass/epoxy pipes with an intermediate layer of fiber glass composite, polyester e sand and with an external layer of high density polyurethane showed superior properties as compared to the other two and met the requirements of pressure class, axial tensile strength, transverse stiffness, impact and environmental conditions, for onshore applications as production lines
Resumo:
The ionic plasma nitriding is one of the most important plasma assisted treatment technique for surface modification, but it presents some inherent problems mainly in nitriding pieces with complex geometries. In the last four years has appeared a plasma nitriding technique, named ASPN (Active Screen Plasma Nitriding) in which the samples and the workload are surrounded by a metal screen on which the cathodic potential is applied. This new technique makes possible to obtain a perfect uniform nitrided layer apart from the shape of the samples. The present work is based on the development of a new nitriding plasma technique named CCPN (Cathodic Cage Plasma Nitriding) Patent PI 0603213-3 derived from ASPN, but utilizes the hollow cathode effect to increase the nitriding process efficiency. That technique has shown great improvement on the treatment of several types of steels under different process conditions, producing thicker and harder layers when compared with both, ASPN and ionic plasma nitriding, besides eliminating problems associated with the later technique. The best obtained results are due to the hollow cathode effect on the cage holes. Moreover, characteristic problems of ionic plasma nitriding are eliminated due to the fact that the luminescent discharge acts on the cage wall instead of on the samples surface, which remains under a floating potential. In this work the enhancement of the cathodic cage nitriding layers proprieties, under several conditions for some types of steels was investigated, besides the mechanism for nitrides deposition on glass substrate, concluding that the CCPN is both a diffusion and a deposition process at the same time
Resumo:
The system built to characterize electrodes and, consequently, deposited fine films are constituted by a hollow cathode that works to discharges and low pressures (approximately 10-3 to 5 mbar), a source DC (0 to 1200 V), a cylindrical camera of closed borossilicato for flanges of stainless steel with an association of vacuum bombs mechanical and spread. In the upper flange it is connected the system of hollow cathode, which possesses an entrance of gas and two entrances for its refrigeration, the same is electrically isolated of the rest of the equipment and it is polarized negatively. In front of the system of hollow cathode there is a movable sample in stainless steel with possibility of moving in the horizontal and vertical. In the vertical, the sample can vary its distance between 0 and 70 mm and, in the horizontal, can leave completely from the front of the hollow cathode. The sample and also the cathode hollow are equipped with cromel-alumel termopares with simultaneous reading of the temperatures during the time of treatment. In this work copper electrodes, bronze, titanium, iron, stainless steel, powder of titanium, powder of titanium and silício, glass and ceramic were used. The electrodes were investigated relating their geometry change and behavior of the plasma of the cavity of hollow cathode and channel of the gas. As the cavity of hollow cathode, the analyzed aspects were the diameter and depth. With the channel of the gas, we verified the diameter. In the two situations, we investigated parameters as flow of the gas, pressure, current and applied tension in the electrode, temperature, loss of mass of the electrode with relationship at the time of use. The flow of gas investigated in the electrodes it was fastened in a work strip from 15 to 6 sccm, the constant pressure of work was among 2.7 to 8 x 10-2 mbar. The applied current was among a strip of work from 0,8 to 0,4 A, and their respective tensions were in a strip from 400 to 220 V. Fixing the value of the current, it was possible to lift the curve of the behavior of the tension with the time of use. That curves esteem in that time of use of the electrode to its efficiency is maximum. The temperatures of the electrodes were in the dependence of that curves showing a maximum temperature when the tension was maximum, yet the measured temperatures in the samples showed to be sensitive the variation of the temperature in the electrodes. An accompaniment of the loss of mass of the electrode relating to its time of use showed that the electrodes that appeared the spherical cavities lost more mass in comparison with the electrodes in that didn't appear. That phenomenon is only seen for pressures of 10-2 mbar, in these conditions a plasma column is formed inside of the channel of the gas and in certain points it is concentrated in form of spheres. Those spherical cavities develop inside of the channel of the gas spreading during the whole extension of the channel of the gas. The used electrodes were cut after they could not be more used, however among those electrodes, films that were deposited in alternate times and the electrodes that were used to deposit films in same times, those films were deposited in the glass substrata, alumina, stainless steel 420, stainless steel 316, silício and steel M2. As the eletros used to deposit films in alternate time as the ones that they were used to deposit in same times, the behavior of the thickness of the film obeyed the curve of the tension with relationship the time of use of the electrode, that is, when the tension was maximum, the thickness of the film was also maximum and when the tension was minimum, the thickness was minimum and in the case where the value of the tension was constant, the thickness of the film tends to be constant. The fine films that were produced they had applications with nano stick, bio-compatibility, cellular growth, inhibition of bacterias, cut tool, metallic leagues, brasagem, pineapple fiber and ornamental. In those films it was investigated the thickness, the adherence and the uniformity characterized by sweeping electronic microscopy. Another technique developed to assist the production and characterization of the films produced in that work was the caloteste. It uses a sphere and abrasive to mark the sample with a cap impression, with that cap form it is possible to calculate the thickness of the film. Through the time of life of the cathode, it was possible to evaluate the rate of waste of its material for the different work conditions. Values of waste rate up to 3,2 x 10-6 g/s were verified. For a distance of the substratum of 11 mm, the deposited film was limited to a circular area of 22 mm diameter mm for high pressures and a circular area of 75 mm for pressure strip. The obtained films presented thickness around 2,1 µm, showing that the discharge of arch of hollow cathode in argon obeys a curve characteristic of the tension with the time of life of the eletrodo. The deposition rate obtained in this system it is of approximately 0,18 µm/min
Resumo:
This work reports the influence of the poly (ethylene terephthalate) textile and films surface modification by plasmas of O2 and mixtures (N2 + O2), on their physical and chemical properties. The plasma surface polymeric modification has been used for many researchs, because it does not affect the environment with toxic agents, the alterations remains only at nanometric layers and this technique shows expressive results. Then, due to its good acceptance, the treatment was carried out in a vacuum chamber. Some parameters remained constant during all treatment, such as: Voltage 470 V; Pressure 1,250 Mbar; Current: 0, 10 A and gas flow: 10 cm3/min, using oxygen plasma alternating the treatment time 10 to 60 min with an increase of 10 min to each subsequent treatment. Also, the samples were treated with a gas mixture (nitrogen + oxygen) which was varied only the gas composition from 0 to 100% leaving the treatment time remaining constant to all treatment (10 min). The plasma treatment was characterized in-situ with Optics Emission Spectroscopy (OES), and the samples was characterized by contact angle, surface tension, Through Capillary tests, Raman spectroscopy, Infrared attenuated total reflection (IR-ATR) and atomic force microscopy, scanning electronic Microscopy (SEM) and X-ray Photoelectron Spectroscopy (XPS). The results showed that oxygen treated fabrics presented high wettability, due to the hydrophilic groups incorporation onto the surface formed through spputering of carbon atoms. For the nitrogen atmosphere, there is the a film deposition of amine groups. Treatment with small oxygen concentration in the mixture with nitrogen has a higher spputered species of the samples
Resumo:
Nickel-bases catalysts have been used in several reform reactions, such as in the partial oxidation of methane to obtain H2 or syngas (H2 + CO). High levels of conversion are usually obtained using this family of catalysts, however, their deactivation resulting from carbon deposition still remains a challenge. Different approaches have been tested aiming at minimizing this difficulty, including the production of perovskites and related structures using modern synthesis methods capable of producing low cost materials with controlled microstructural characteristics at industrial scale. To establish grounds for comparison, in the present study LaNixFe1-xO3 (x=0, 0.3 or 0.7) perovskites were prepared following the Pechini method and by microwave assisted self-combustion. All samples were sub sequently calcined at 900 °C to obtain the target phase. The resulting ceramic powders were characterized by thermogravimetric analysis, infrared spectroscopy, X ray diffraction, specific area and temperature programmed reduction tests. Calcined samples were also used in the partial oxidation reaction of methane to evaluate the level of conversion, selectivity and carbon deposition. The results showed that the calcined samples were crystalline and the target phase was formed regardless of the synthesis method. According to results obtained by Rietveld refinement, we observed the formation of 70.0% of LaNi0.3Fe0.7O3 and 30.0% of La2O3 for samples LN3F7-900- P, LN3F7-900-M and 41,6% of LaNi0.7Fe0.3O3, 30.7% of La2NiO4 and 27.7% of La2O3 for samples LN7F3-900-P and LN7F3-900-M.Temperature-programmed profiles of the LaNiO3 sample revealed the presence of a peak around 510 °C, whereas the LaFeO3 sample depicted a peak above 1000°C. The highest l evel of methane conversion was obtained for LaNiO3 synthesized by the Pechini method. Overall, catalysts prepared by the Pechini method depicted better conversion levels compared to those produced by microwave assisted self-combustion
Resumo:
This work aims at obtaining nanoparticles of iron oxide, the magnetite one (Fe3O4), via synthesis by thermal decomposition through polyol. Thus, two routes were evaluated: a simple decomposition route assisted by reflux and a hydrothermal route both without synthetic air atmosphere using a synthesis temperature of 260ºC. In this work observed the influence of the observe of surfactants which are generally applied in the synthesis of iron oxide nanoparticles decreasing cluster areas. Further, was observed pure magnetite phase without secondary phases generally found in the iron oxide synthesis, a better control of crystallite size, morphology, crystal structure and magnetic behavior. Finally, the introduction of hydroxyl groups on the nanoparticles surface was analyzed besides its employment in the polymer production with OH radicals. The obtained materials were characterized by XRD, DLS, VSM, TEM, TG and DSC analyses. The results for the magnetite obtainment with a particle size greater than 5 nm and smaller than 11 nm, well defined morphology and good magnetic properties with superparamagnetic behavior. The reflux synthesis was more efficient in the deposition of the hydroxyl groups on the nanoparticles surface
Resumo:
Brazil has vast amounts of hydric resources, whose quality has been deteriorating due to pollutant dumping. Household waste disposal is one of the main sources of water pollution, stimulating bacteria proliferation and introducing microorganisms, including those from fecal matter. Conventional water disinfection methods are a solution, but on the downside, they lead to the formation byproducts hazardous to human health. In this study, aiming to develop bactericidal filters for the disinfection of drinking water; silver nanoparticles were deposited on alumina foams through three routes: sputtering DC, dip coating and in situ chemical reduction of silver nitrate. The depositions were characterized through X-ray diffraction, scanning electron microscopy and EDS element mapping. The influence of the depositions on permeability and mechanical properties of the ceramic foams was assessed and, in sequence, a preliminary antibacterial efficiency analysis was carried out. Characterization results indicate that the chemical reduction routes were efficient in depositing homogeneously distributed silver particles and that the concentration of the metallic precursor salt affects size and morphology of the particles. The antibacterial efficiency analysis indicates that the chemical reduction filters have potential for water disinfection
Resumo:
Doped lanthanum chromite ( LaCrO3 ) has been the most common material used as interconnect in solid oxide fuel cells for high temperature ( SOFC-HT ) that enabling the stack of SOFCs. The reduction of the operating temperature, to around 800 º C, of solid oxide fuel cells enabled the use of metallic interconnects as an alternative to ceramic LaCrO3, From the practical point of view, to be a strong candidate for interconnect the material must have good physical and mechanical properties such as resistance to oxidizing and reducing environments, easy manufacture and appropriate thermo-mechanical properties. Thus, a study on the physic-mechanical interconnects La0,8Sr0,2Cr0,92Co0,08O3 ceramics for SOFC -AT obtained by the method of combustion , as well as thermo-mechanical properties of metallic interconnects (AISI 444) covered with La0,8Ca0,2CrO3 by deposition technique by spray-pyrolysis fuel cells for intermediate temperature (IT-SOFCs). The La0,8Sr0,2Cr0,92Co0,08O3 was characterized by X -ray diffraction(XRD) , density and porosity , Vickers hardness (HV) , the flexural strength at room temperature and 900 °C and scanning electron microscopy (SEM). The X -ray diffraction confirmed the phase formation and LaCrO3 and CoCr2O4, in order 6 GPa hardness and mechanical strength at room temperature was 62 MPa ceramic Interconnector. The coated metal interconnects La0,8Ca0,2CrO3 passed the identification by XRD after deposition of the film after the oxidation test. The oxidative behavior showed increased resistance to oxidation of the metal substrate covered by La0,8Ca0,2CrO3 In flexural strength of the coated metal substrate, it was noticed only in the increased room temperature. The a SEM analysis proved the formation of Cr2O3 and (Cr,Mn)3O4 layers on metal substrate and confirmed the stability of the ceramic La0,8 Ca0,2CrO3 film after oxidative test
Resumo:
The general objective of this study was to contribute to the understanding of the chemical evolution of fluids that percolate through carbonate rocks of the Jandaíra Formation. The oxidation and reduction conditions in which grains, source and cement were formed was investigated using the cathodoluminescence technique (CL). The study area is located in the west part of the Potiguar Basin (Fazenda Belém field) and Rosário Ledge (Felipe Guerra municipality, State of Rio Grande do Norte, Brazil). The analysis of thin sections of carbonate rocks under CL revealed that grains (allochemical or not) and diagenetic products (micritization, dolomitization, neomorphism and cementation) exhibit since absence of luminescence the various luminescence colors (yellow, orange, red, brown, and blue) in a variety of intensities. As pure calcite shows dark blue luminescence, the occurrence of different luminescence colors in calcite crystals suggest one or more punctual crystal defects such as free electron, free space and impurity. The dyeing of thin sections with alizarin and potassium ferrocyanide revealed the absence of ferrous carbonate in the different lithotypes of Jandaíra Formation. Therefore, the different colors and intensities of CL observed in these rocks are probably caused by the presence of ion activators such as Mn2+ and is not an activator/inhibitor combination. In the same way, the absence of luminescence is very probably caused by the absence of activator ions and not due to the low concentration of inhibitor ions such as Fe2+. The incorporation of Mn2+ in the different members of the Jandaíra Formation must have been controlled by the redox state of the depositional environment and diagenesis. Therefore, it is possible that the luminescent members have been formed (e.g.,ooids) or have been modified (gastropod neomorphism) under reduction conditions in the depositional environments, in subsurface during the burial, or, in the case of Rosario Ledge samples , during the post-burial return to surface conditions. As regards the sudden changes from low to moderate and to strong luminescence, these features should indicate the precipitation of a fluid with chemical fluctuations, which formed the frequent zonations in the block cement of the Rosario Ledge samples. This study suggests that the different intensities and colors of CL should be correlated with the Mn2+ and Fe2+ contents, and stable isotopes of samples to determine the salinity, temperature, pH e Eh conditions during deposition
Resumo:
Discrepancies between classical model predictions and experimental data for deep bed filtration have been reported by various authors. In order to understand these discrepancies, an analytic continuum model for deep bed filtration is proposed. In this model, a filter coefficient is attributed to each distinct retention mechanism (straining, diffusion, gravity interception, etc.). It was shown that these coefficients generally cannot be merged into an effective filter coefficient, as considered in the classical model. Furthermore, the derived analytic solutions for the proposed model were applied for fitting experimental data, and a very good agreement between experimental data and proposed model predictions were obtained. Comparison of the obtained results with empirical correlations allowed identifying the dominant retention mechanisms. In addition, it was shown that the larger the ratio of particle to pore sizes, the more intensive the straining mechanism and the larger the discrepancies between experimental data and classical model predictions. The classical model and proposed model were compared via statistical analysis. The obtained p values allow concluding that the proposed model should be preferred especially when straining plays an important role. In addition, deep bed filtration with finite retention capacity was studied. This work also involves the study of filtration of particles through porous media with a finite capacity of filtration. It was observed, in this case, that is necessary to consider changes in the boundary conditions through time evolution. It was obtained a solution for such a model using different functions of filtration coefficients. Besides that, it was shown how to build a solution for any filtration coefficient. It was seen that, even considering the same filtration coefficient, the classic model and the one here propposed, show different predictions for the concentration of particles retained in the porous media and for the suspended particles at the exit of the media
Resumo:
Os objetivos neste trabalho foram estimar as correlações entre medidas obtidas por ultrassonografia e na carcaça e acompanhar o desenvolvimento da área de olho-de-lombo e a deposição de gordura de búfalos em diferentes períodos de confinamento. Foram utilizados 20 bubalinos da raça Murrah, castrados, abatidos aos 75, 100, 125 ou 150 dias de confinamento. As medidas realizadas foram área de olho-de-lombo, espessura de gordura subcutânea do dorso e espessura de gordura da garupa, mensuradas por ultrassonografia quando os búfalos atingiram o tempo de abate e na carcaça, após o abate. A espessura de gordura subcutânea da carcaça foi avaliada utilizando-se paquímetro e a área de olho-de-lombo da carcaça, régua do quadrante de pontos. O período de confinamento apresentou efeito linear crescente na área de olho-de-lombo e nas espessuras de gordura do dorso e da garupa avaliadas por ultrassom e na carcaça. O efeito linear positivo entre 75 e 150 dias de confinamento, tanto para a área de olho-de-lombo como para espessura de gordura medidas no dorso e na garupa, comprovou que os animais ainda não haviam atingido a maturidade. As correlações entre as medidas obtidas por ultrassom e na carcaça foram 0,82 para área de olho-de-lombo e 0,85 para espessura de gordura subcutânea no dorso. As características de carcaça medidas por ultrassom em bubalinos apresentam boas correlações com as medidas realizadas na carcaça no momento do abate, o que permite, em bubalinos da raça Murrah castrados e oriundos de rebanho leiteiro, acompanhar as alterações dessas características durante o desenvolvimento.
Resumo:
Existem fortes evidências de que os programas de rastreamento baseados em citologia resultaram em diminuição significativa da incidência e mortalidade por câncer do colo do útero, no entanto, um excesso substancial de tratamento de lesões intraepiteliais de baixo grau que dificilmente progrediriam para carcinoma cervical resulta da baixa especificidade do tradicional rastreio citológico. A detecção precoce das lesões através do rastreamento citológico e a avaliação do grau histológico em espécimes cervicais são fundamentais, entretanto não permitem identificar quais pacientes terão maior probabilidade de progressão para lesões de alto grau e carcinoma invasivo. A busca de potenciais marcadores de prognóstico; objetivando o entendimento da progressão das lesões intraepiteliais é de suma importância. Acredita-se que fatores imunoregulatórios, imunogenéticos e proteínas do ciclo celular estejam intimamente envolvidos no processo de carcinogênese. Considerando o exposto, a proposta do projeto foi inicialmente avaliar a eficácia da citologia oncológica no rastreamento do câncer cervical, foi investigado ainda o polimorfismo do gene do fator de transcrição FOXP3 e a expressão da proteína do ciclo celular P63 (P63) associados respectivamente a diagnóstico e prognóstico das lesões cervicais. Em um primeiro momento foi realizado estudo transversal que envolveu 3194 mulheres. As participantes foram submetidas à citologia e biópsia de colo dirigida por colposcopia e os resultados foram comparados para verificar-se a acurácia do teste de Papanicolaou na detecção de lesões intraepiteliais e câncer cervical. Posteriormente, realizou-se estudo comparativo do tipo observacional estratificado em três grupos: Grupo 1: 16 casos com diagnóstico histopatológico de metaplasia/cervicite, considerados normais, Grupo 2: 11 casos com lesão de baixo grau (LSIL) e Grupo 3: 15 casos com lesão de alto grau (HSIL) ou carcinoma epidermoide de colo. Um total de 42 participantes respondeu a um questionário epidemiológico padronizado sobre as características demográficas, hábitos pregressos, história reprodutiva e de comportamento sexual. Após exame colposcópico, foram coletados fragmentos de espécimes cervicais para a pesquisa da expressão proteica da P63 por imunohistoquímica. Amostras de sangue periférico foram coletadas para extração do DNA e detecção do polimorfismo do gene FOXP3. No primeiro estudo em que se avaliou a acurácia do teste de Papanicolaou, encontrou-se sensibilidade de 0,83, valor preditivo positivo (VPP) de 0,77 e especificidade de 0,23 no rastreamento das lesões cervicais e câncer de colo. viii Melhores resultados foram observados quando se avaliou a acurácia diagnóstica para lesões de alto grau e carcinoma com VPP de 0,99 e especificidade de 0,84.No estudo subsequente onde se comparou a expressão da proteína P63 observou-se maior número de núcleos marcados no grupo com lesões intraepiteliais de alto grau e câncer quando comparado ao grupo com biópsias negativas (p=0,0004). No último estudo pesquisou-se a associação do polimorfismo do gene FOXP3 com lesões intraepiteliais cervicais sendo evidenciada maior prevalência do genótipo heterozigoto, CT, no grupo com lesões de colo na histopatologia (p=0,027). Mulheres com lesões intraepiteliais de baixo ou alto grau e câncer de colo de útero apresentam maior expressão da proteína P63 e maior prevalência de genótipo heterozigoto do gene FOXP3 em comparação com as sem lesões cervicais. A associação da pesquisa da expressão da proteína e do polimorfismo do gene pode tornar os exames utilizados atualmente para a avaliação diagnóstica e prognóstica das lesões de colo uterino mais efetivos em detectar quais as mulheres com maior risco para progressão para câncer
Resumo:
O objetivo neste trabalho foi avaliar o desempenho de pacus (Piaractus mesopotamicus) criados em tanques-rede e alimentados com dietas contendo níveis de proteína bruta (PB) e energia digestível (ED). Foram utilizados 3.960 peixes com 293,38 ± 5,67 g de peso inicial, distribuídos em 18 tanques-rede de 5 m³, com 220 peixes por unidade experimental (44 peixes/m³), em esquema fatorial 3 × 2, composto de três níveis de proteína bruta (25, 30 e 35%) e dois de energia digestível (3.250 e 3.500 kcal/kg). O arraçoamento foi realizado quatro vezes ao dia (às 9 h, 11h30min, 14 h e 17 h) até a saciedade aparente dos animais. Não foram observadas diferenças no ganho de peso, na taxa de sobrevivência, na conversão alimentar aparente nem na taxa de crescimento específico. No entanto, houve diferença na deposição de gordura visceral, que foi maior nos animais alimentados com as rações de maior nível energético. Também não foi observada influência dos níveis de proteína e energia da dieta nos teores de umidade, proteína bruta, matéria mineral e lipídio dos filés. Rações contendo 25% de proteína bruta e 3.250 kcal/kg de energia digestível promovem melhores resultados de desempenho.
Desempenho zootécnico de girinos de rã-touro com diferentes níveis de proteína e energia digestíveis
Resumo:
A partir dos valores de digestibilidade de alguns ingredientes foram propostas dietas, com diferentes níveis de proteína e energia digestíveis, em esquema fatorial 3 x 3, destinadas a girinos de rã-touro para avaliar o desempenho zootécnico. O experimento, com duração de 60 dias, foi conduzido com 810 girinos, oriundos da mesma desova, distribuídos em 27 caixas de polipropileno, em uma densidade de 1girino/L. O delineamento experimental foi um esquema fatorial com três níveis de proteína digestível (27; 31 e 35%) e três níveis de energia digestível (2.700; 2.800 e 2.900kcal/kg) com três réplicas. Os parâmetros avaliados aos 60 dias foram ganho de peso, consumo da dieta, consumo em proteína da dieta, conversão alimentar, taxa de eficiência proteica e índice de sobrevivência. Os resultados foram submetidos à análise de variância e ao teste de Duncan (95% de precisão). Os resultados encontrados não apresentaram interação entre proteína e energia digestível para nenhum parâmetro avaliado. em relação à proteína digestível, foram verificadas diferenças nos parâmetros consumo em proteína da dieta e taxa de eficiência proteica (TEP), o que demonstra ineficiência das dietas com altos valores proteicos. Deve-se oferecer aos girinos de rã-touro dietas com 27% de proteína digestível, por apresentarem melhor resultado para taxa de eficiência proteica e para consumo em proteína da dieta.
Resumo:
Hereditary Hemochromatosis (HH) is a genetic disease caused by high iron absorption and deposition in several organs. This accumulation results in clinical disturbances such as cirrhosis, arthritis, cardiopathies, diabetes, sexual disorders and skin darkening. The H63D and C282Y mutations are well defined in the hemochromatosis etiology. The aim of this paper was that of identifying the H63D and C282Y genetical mutations in the hemochromatosis gene and the frequency assessment of these mutations in the HFE protein gene in patients with hyperferritin which are sent to the DNA Center laboratory in Natal, state of Rio Grande do Norte. This paper also evaluates the HH H63D and C282Y gene mutations genotype correlation with the serum ferritin concentration, glucose, alanine aminotransferasis, aspartato aminotransferasis, gama glutamil transferasis and with the clinical complications and also the interrelation with life habits including alcoholism and iron overload. The biochemical dosages and molecule analyses are done respectively by the enzymatic method and PCR with enzymatic restriction. Out of the 183 patients investigated, 51,4% showed no mutation and 48,6% showed some type of mutation: 5,0% were C282Y heterozygous mutation; 1,1%, C282Y homozygous mutation; 31%, H63D heterozygous mutation; 8,7%, H63D homozygous mutation; and 3,3%, heterozygous for the mutation in both genes. As to gender, we observed a greater percentage of cases with molecular alteration in men in relation to women in the two evaluated mutations. The individuals with negative results showed clinical and lab signs which indicate hemochromatosis that other genes could be involved in the iron metabolism. Due to the high prevalence of hemochromatosis and taking into account that hemochromatosis is considered a public health matter, its gravity being preventable and the loss treatment toxicity, the early genetic diagnosis is indicated, especially in patients with high ferritin, and this way it avoids serious clinical manifestations and increases patients' life expectation. Our findings show the importance of doing such genetic studies in individuals suspected of hereditary hemochromatosis due to the high incidence of such a hereditary disease in our region