999 resultados para dental air abrasion


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives: A study was made to determine the temperature increment at the dental root surface following Er,Cr:YSGG laser irradiation of the root canal. Design. Human canines and incisors previously instrumented to K file number ISO 30 were used. Irradiation was carried out with glass fiber endodontic tips measuring 200 μm in diameter and especially designed for insertion in the root canal. The teeth were irradiated at 1 and 2 W for 30 seconds, without water spraying or air, and applying a continuous circular movement (approximately 2 mm/sec.) in the apico-coronal direction. Results: At the 1 W power setting, the mean temperature increment was 3.84ºC versus 5.01ºC at 2 W. In all cases the difference in mean value obtained after irradiation versus the mean baseline temperature proved statistically significant (p< 0.05). Conclusions: Application of the Er,Cr:YSGG laser gives rise to a statistically significant temperature increment at the external root surface, though this increment is probably clinically irrelevant, since it would appear to damage the tissues (periodontal ligament and alveolar bone) in proximity to the treated tooth

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Nicotine in a smoky indoor air environment can be determined using graphitized carbon black as a solid sorbent in quartz tubes. The temperature stability, high purity, and heat absorption characteristics of the sorbent, as well as the permeability of the quartz tubes to microwaves, enable the thermal desorption by means of microwaves after active sampling. Permeation and dynamic dilution procedures for the generation of nicotine in the vapor phase at low and high concentrations are used to evaluate the performances of the sampler. Tube preparation is described and the microwave desorption temperature is measured. Breakthrough volume is determined to allow sampling at 0.1-1 L/min for definite periods of time. The procedure is tested for the determination of gas and paticulate phase nicotine in sidestream smoke produced in an experimental chamber.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Woven monofilament, multifilament, and spun yarn filter media have long been the standard media in liquid filtration equipment. While the energy for a solid-liquid separation process is determined by the engineering work, it is the interface between the slurry and the equipment - the filter media - that greatly affects the performance characteristics of the unit operation. Those skilled in the art are well aware that a poorly designed filter medium may endanger the whole operation, whereas well-performing filter media can make the operation smooth and economical. As the mineral and pulp producers seek to produce ever finer and more refined fractions of their products, it is becoming increasingly important to be able to dewater slurries with average particle sizes around 1 ¿m using conventional, high-capacity filtration equipment. Furthermore, the surface properties of the media must not allow sticky and adhesive particles to adhere to the media. The aim of this thesis was to test how the dirt-repellency, electrical resistance and highpressure filtration performance of selected woven filter media can be improved by modifying the fabric or yarn with coating, chemical treatment and calendering. The results achieved by chemical surface treatments clearly show that the woven media surface properties can be modified to achieve lower electrical resistance and improved dirt-repellency. The main challenge with the chemical treatments is the abrasion resistance and, while the experimental results indicate that the treatment is sufficiently permanent to resist standard weathering conditions, they may still prove to be inadequately strong in terms of actual use.From the pressure filtration studies in this work, it seems obvious that the conventional woven multifilament fabrics still perform surprisingly well against the coated media in terms of filtrate clarity and cake build-up. Especially in cases where the feed slurry concentration was low and the pressures moderate, the conventional media seemed to outperform the coated media. In the cases where thefeed slurry concentration was high, the tightly woven media performed well against the monofilament reference fabrics, but seemed to do worse than some of the coated media. This result is somewhat surprising in that the high initial specific resistance of the coated media would suggest that the media will blind more easily than the plain woven media. The results indicate, however, that it is actually the woven media that gradually clogs during the coarse of filtration. In conclusion, it seems obvious that there is a pressure limit above which the woven media looses its capacity to keep the solid particles from penetrating the structure. This finding suggests that for extreme pressures the only foreseeable solution is the coated fabrics supported by a strong enough woven fabric to hold thestructure together. Having said that, the high pressure filtration process seems to follow somewhat different laws than the more conventional processes. Based on the results, it may well be that the role of the cloth is most of all to support the cake, and the main performance-determining factor is a long life time. Measuring the pore size distribution with a commercially available porometer gives a fairly accurate picture of the pore size distribution of a fabric, but failsto give insight into which of the pore sizes is the most important in determining the flow through the fabric. Historically air, and sometimes water, permeability measures have been the standard in evaluating media filtration performance including particle retention. Permeability, however, is a function of a multitudeof variables and does not directly allow the estimation of the effective pore size. In this study a new method for estimating the effective pore size and open pore area in a densely woven multifilament fabric was developed. The method combines a simplified equation of the electrical resistance of fabric with the Hagen-Poiseuille flow equation to estimate the effective pore size of a fabric and the total open area of pores. The results are validated by comparison to the measured values of the largest pore size (Bubble point) and the average pore size. The results show good correlation with measured values. However, the measured and estimated values tend to diverge in high weft density fabrics. This phenomenon is thought to be a result of a more tortuous flow path of denser fabrics, and could most probably be cured by using another value for the tortuosity factor.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The present dissertation is devoted to the systematic approach to the development of organic toxic and refractory pollutants abatement by chemical decomposition methods in aqueous and gaseous phases. The systematic approach outlines the basic scenario of chemical decomposition process applications with a step-by-step approximation to the most effective result with a predictable outcome for the full-scale application, confirmed by successful experience. The strategy includes the following steps: chemistry studies, reaction kinetic studies in interaction with the mass transfer processes under conditions of different control parameters, contact equipment design and studies, mathematical description of the process for its modelling and simulation, processes integration into treatment technology and its optimisation, and the treatment plant design. The main idea of the systematic approach for oxidation process introduction consists of a search for the most effective combination between the chemical reaction and the treatment device, in which the reaction is supposed to take place. Under this strategy,a knowledge of the reaction pathways, its products, stoichiometry and kinetics is fundamental and, unfortunately, often unavailable from the preliminary knowledge. Therefore, research made in chemistry on novel treatment methods, comprisesnowadays a substantial part of the efforts. Chemical decomposition methods in the aqueous phase include oxidation by ozonation, ozone-associated methods (O3/H2O2, O3/UV, O3/TiO2), Fenton reagent (H2O2/Fe2+/3+) and photocatalytic oxidation (PCO). In the gaseous phase, PCO and catalytic hydrolysis over zero valent ironsare developed. The experimental studies within the described methodology involve aqueous phase oxidation of natural organic matter (NOM) of potable water, phenolic and aromatic amino compounds, ethylene glycol and its derivatives as de-icing agents, and oxygenated motor fuel additives ¿ methyl tert-butyl ether (MTBE) ¿ in leachates and polluted groundwater. Gas-phase chemical decomposition includes PCO of volatile organic compounds and dechlorination of chlorinated methane derivatives. The results of the research summarised here are presented in fifteenattachments (publications and papers submitted for publication and under preparation).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work deals with the cooling of high-speed electric machines, such as motors and generators, through an air gap. It consists of numerical and experimental modelling of gas flow and heat transfer in an annular channel. Velocity and temperature profiles are modelled in the air gap of a high-speed testmachine. Local and mean heat transfer coefficients and total friction coefficients are attained for a smooth rotor-stator combination at a large velocity range. The aim is to solve the heat transfer numerically and experimentally. The FINFLO software, developed at Helsinki University of Technology, has been used in the flow solution, and the commercial IGG and Field view programs for the grid generation and post processing. The annular channel is discretized as a sector mesh. Calculation is performed with constant mass flow rate on six rotational speeds. The effect of turbulence is calculated using three turbulence models. The friction coefficient and velocity factor are attained via total friction power. The first part of experimental section consists of finding the proper sensors and calibrating them in a straight pipe. After preliminary tests, a RdF-sensor is glued on the walls of stator and rotor surfaces. Telemetry is needed to be able to measure the heat transfer coefficients at the rotor. The mean heat transfer coefficients are measured in a test machine on four cooling air mass flow rates at a wide Couette Reynolds number range. The calculated values concerning the friction and heat transfer coefficients are compared with measured and semi-empirical data. Heat is transferred from the hotter stator and rotor surfaces to the coolerair flow in the air gap, not from the rotor to the stator via the air gap, althought the stator temperature is lower than the rotor temperature. The calculatedfriction coefficients fits well with the semi-empirical equations and precedingmeasurements. On constant mass flow rate the rotor heat transfer coefficient attains a saturation point at a higher rotational speed, while the heat transfer coefficient of the stator grows uniformly. The magnitudes of the heat transfer coefficients are almost constant with different turbulence models. The calibrationof sensors in a straight pipe is only an advisory step in the selection process. Telemetry is tested in the pipe conditions and compared to the same measurements with a plain sensor. The magnitudes of the measured data and the data from the semi-empirical equation are higher for the heat transfer coefficients than thenumerical data considered on the velocity range. Friction and heat transfer coefficients are presented in a large velocity range in the report. The goals are reached acceptably using numerical and experimental research. The next challenge is to achieve results for grooved stator-rotor combinations. The work contains also results for an air gap with a grooved stator with 36 slots. The velocity field by the numerical method does not match in every respect the estimated flow mode. The absence of secondary Taylor vortices is evident when using time averagednumerical simulation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A beautiful smile is directly related with white teeth. Nowadays oral care has increased and developed processes for beautiful smiles. Dental bleaching is frequently used in odontology, not just for health care also for aesthetic treatment. With the possibility of teeth bleaching, now the importance is in, how white the tooth is? Because color is relate to an individual perception. In order to assets teeth correct color identification has been developed many color guides, models, spaces and analytical methods. Spite all of these useful tools the color interpretation depends on environmental factors, position of the sample in the data acquisition and most importantly the instrument sensitivity. The commons methods have proved to be useful. They are easy to handle, some are portable but they do not have a high sensitivity. The present work is based on the integration of a new analytical technique for color acquisition. High spectral Image (HSI) is able to performed image analysis with high quality and efficiency. HSI is used in many fields and we used it for color image analysis within the bleaching process. The main comparison was done with the HSI and the colorimeter through the processes of two different bleaching protocols. The results showed that HSI has higher sensitivity than the colorimeter. During the analysis the dental surface with the HSI we were able to notice surface changes. These changes were analyzed by roughness studies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Water lines are an important source of potentíal contamination. Every dental unit is equipped with small-bore flexible plastic tubing to bring water to different hand pieces, such as the air/water syringe, the ultrasonic scaler or the high-speed hand piece. Most dental units are connected directly to municipal distribution systems for potable water and chlorinated or not, this water contains diverse...

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A study was conducted to determine the possibility of cashew (Anacardium occidentale) cloning by air-layering and influence of IBA (indol-butyric acid) on this process. It was adopted a completely randomized design with 4 treatments, 10 air layers each and 4 replications, reaching 160 air layers. The IBA levels on the treatments were, as follow: 0, 1000, 3000 and 5000 mg.kg-1. It was evaluated: survival, callus and rooting percentage, average number and length of roots. The highest survival rate (67.5%) was registered with no growth regulator and IBA at 1000 mg.kg-1, while the best rooting percentage (82%) referred to 1000 mg.kg-1. In spite of average number and length of roots, the highest results were observed with IBA at 5000 mg.kg-1. IBA concentrations had no influence on cashew air-layering formation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To evaluate the variability of bond strength test results of adhesive systems (AS) and to correlate the results with clinical parameters of clinical studies investigating cervical restorations. MATERIALS AND METHODS: Regarding the clinical studies, the internal database which had previously been used for a meta-analysis on cervical restorations was updated with clinical studies published between 2008 and 2012 by searching the PubMed and SCOPUS databases. PubMed and the International Association for Dental Research abstracts online were searched for laboratory studies on microtensile, macrotensile and macroshear bond strength tests. The inclusion criteria were (1) dentin, (2) testing of at least four adhesive systems, (3) same diameter of composite and (4) 24h of water storage prior to testing. The clinical outcome variables were retention loss, marginal discoloration, detectable margins, and a clinical index comprising the three parameters by weighing them. Linear mixed models which included a random study effect were calculated for both, the laboratory and the clinical studies. The variability was assessed by calculating a ratio of variances, dividing the variance among the estimated bonding effects obtained in the linear mixed models by the sum of all variance components estimated in these models. RESULTS: Thirty-two laboratory studies fulfilled the inclusion criteria comprising 183 experiments. Of those, 86 used the microtensile test evaluating 22 adhesive systems (AS). Twenty-seven used the macrotensile test with 17 AS, and 70 used the macroshear test with 24 AS. For 28 AS the results from clinical studies were available. Microtensile and macrotensile (Spearman rho=0.66, p=0.007) were moderately correlated and also microtensile and macroshear (Spearman rho=0.51, p=0.03) but not macroshear and macrotensile (Spearman rho=0.34, p=0.22). The effect of the adhesive system was significant for microtensile and macroshear (p<0.001) but not for macrotensile. The effect of the adhesive system could explain 36% of the variability of the microtensile test, 27% of the macrotensile and 33% of the macroshear test. For the clinical trials, about 49% of the variability of retained restorations could be explained by the adhesive system. With respect to the correlation between bond strength tests and clinical parameters, only a moderate correlation between micro- and macrotensile test results and marginal discoloration was demonstrated. However, no correlation between these tests and a retention loss or marginal integrity was shown. The correlation improved when more studies were included compared to assessing only one study. SIGNIFICANCE: The high variability of bond strength test results highlights the need to establish individual acceptance levels for a given test institute. The weak correlation of bond-strength test results with clinical parameters leads to the conclusion that one should not rely solely on bond strength tests to predict the clinical performance of an adhesive system but one should conduct other laboratory tests like tests on the marginal adaptation of fillings in extracted teeth and the retention loss of restorations in non-retentive cavities after artificial aging.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: There are limited data on the composition and smoke emissions of 'herbal' shisha products and the air quality of establishments where they are smoked. METHODS: Three studies of 'herbal' shisha were conducted: (1) samples of 'herbal' shisha products were chemically analysed; (2) 'herbal' and tobacco shisha were burned in a waterpipe smoking machine and main and sidestream smoke analysed by standard methods and (3) the air quality of six waterpipe cafes was assessed by measurement of CO, particulate and nicotine vapour content. RESULTS: We found considerable variation in heavy metal content between the three products sampled, one being particularly high in lead, chromium, nickel and arsenic. A similar pattern emerged for polycyclic aromatic hydrocarbons. Smoke emission analyses indicated that toxic byproducts produced by the combustion of 'herbal' shisha were equivalent or greater than those produced by tobacco shisha. The results of our air quality assessment demonstrated that mean PM2.5 levels and CO content were significantly higher in waterpipe establishments compared to a casino where cigarette smoking was permitted. Nicotine vapour was detected in one of the waterpipe cafes. CONCLUSIONS: 'Herbal' shisha products tested contained toxic trace metals and PAHs levels equivalent to, or in excess of, that found in cigarettes. Their mainstream and sidestream smoke emissions contained carcinogens equivalent to, or in excess of, those of tobacco products. The content of the air in the waterpipe cafes tested was potentially hazardous. These data, in aggregate, suggest that smoking 'herbal' shisha may well be dangerous to health.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Tämän diplomityön tarkoituksena oli asentaa ja kehittää UPM-Kymmene Rauman tehtaiden PK2:lle luotettava ja toimiva ilmanläpäisyprofiilin mittaus. Työn tarkoituksena oli myös kartoittaa tietoja ilmanläpäisyprofiiliin vaikuttavista seikoista sekä mahdollisuuksista säätää ilmanläpäisyprofiilia. Lisäksi työn tavoitteena oli löytää toimiva menetelmä verrata online mitattua ilmanläpäisyprofiilia laboratoriossa mitattuun ilmanläpäisyprofiiliin online mittauksen luotettavuuden näkökulmasta. Työn aikana selvitettiin myös ilmanläpäisyprofiilin mittauksen mahdollisuutta superkalanteroidusta SC paperista. Työn kirjallisessa osassa käsiteltiin paperin huokoisuutta ja ilmanläpäisyä, huokoisuustasoon ja huokoisuus profiiliin vaikuttavia tekijöitä, ilmanläpäisevyyden merkitystä SC paperin valmistukselle ja SC paperin painettavuudelle sekä ilmanläpäisevyyden laboratorio- sekä online mittausta. Kirjallisessa osassa käsiteltiin myös Honeywellin uutta Poros ilmanläpäisysensoria. Työn kokeellisessa osassa tutkittiin ilmanläpäisyprofiilimittauksen luotettavuutta CD ja MD suunnassa sekä laboratorio- ja online-mittausten välisiä eroavaisuuksia ennen PK2 uusintaa. PK2 uusinnan jälkeen kokeellisessa osassa keskityttiin luotettavuuden varmentamiseen CD ja MD suunnassa sekä kartoittamaan tekijöitä, jotka aiheuttivat pieniä tasoeroja mittausten välillä. Mittaukset todettiin luotettaviksi ja niiden pohjalta suoritettiin mitattujen online profiilien välisiä vertailuja. Ilmanläpäisyprofiililla todettiin olevan positiivinen korrelaatio neliömassaprofiilin ja kosteusprofiilin kanssa sekä negatiivinen korrelaatio tuhkaprofiilin kanssa. PK2 uusinnan yhteydessä tehtiin koeajoja, jotka liittyivät laadunoptimointiin viira- ja puristinosalla. Koeajoissa tutkittujen asioiden lisäksi tutkittiin muutettujen parametrien vaikutusta ilmanläpäisyprofiiliin. Höyrylaatikon vaikutusta ilmanläpäisyprofiiliin tutkittiin säätöjen virityksen yhteydessä.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Työssä tarkastellaan kahta kaasuturbiinin imuilman sisäänottojärjestelmän kehitysmenetelmää, imuilman jäähdytystä ja sähköstaattista suodatusta. Imuilman jäähdytysmenetelmien tarkastelussa käytettiin kahta kaasuturbiinin tehonlisäystekniikoiden laskentatyökalua. Arviointi kohdistettiin Glanford Brigg Generating Station -voimalaitoksen kaasuturbiinityyppiin ja paikallisiin englantilaisiin ilmasto-olosuhteisiin. Tarkastelussa olivat kostutusjäähdytys ja overspray. Tuloksia vertailtiin keskenään ja näiden perusteella arvioitiin menetelmien vaikutuksia tehoon, hyötysuhteeseen sekä veden kulutukseen. Sähköstaattisen suodattimen prototyyppi oli rakennettu Briggin voimalaitokselle. Järjestelmää kehitetään kaupalliseksi tuotteeksi ja tätä varten kerättiin tekninen dokumentaatio kokonaisuudeksi, jota voitiin hyödyntää tuotteistusprosessissa. Imuilman jäähdyttämisellä voidaan saavuttaa merkittävä tehonlisäys ilmasto-olosuhteista riippuen. Menetelmällä voidaan myös tasata lämpötilan vuorokausi-vaihtelusta aiheutuvia tehoeroja. Sähköstaattisen suodattimen prototyyppi saavutti kehitysvaiheelle asetetut tavoitteet. Sähköstaattinen suodatus tarjoaa useita etuja perinteiseen mekaaniseen suodatukseen verrattuna.