992 resultados para critical frequency


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Rock-paper-scissors (RPS) dynamics, which maintain genetic polymorphisms over time through negative frequency-dependent (FD) selection, can evolve in short-lived species with no generational overlap, where they produce rapid morph frequency cycles. However, most species have overlapping generations and thus, rapid RPS dynamics are thought to require stronger FD selection, the existence of which yet needs to be proved. Here, we experimentally demonstrate that two cumulative selective episodes, FD sexual selection reinforced by FD selection on offspring survival, generate sufficiently strong selection to generate rapid morph frequency cycles in the European common lizard Zootoca vivipara, a multi-annual species with major generational overlap. These findings show that the conditions required for the evolution of RPS games are fulfilled by almost all species exhibiting genetic polymorphisms and suggest that RPS games may be responsible for the maintenance of genetic diversity in a wide range of species.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Tumor-reactive T cells play an important role in cancer immunosurveillance. Applying the multimer technology, we report here an unexpected high frequency of Melan-A-specific CTLs in a melanoma patient with progressive lymph node metastases, consisting of 18 and 12.8% of total peripheral blood and tumor-infiltrating CD8+ T cells, respectively. Melan-A-specific CTLs revealed a high cytolytic activity against allogeneic Melan-A-expressing target cells but failed to kill the autologous tumor cells. Loading of the tumor cells with Melan-A peptide reversed the resistance to killing, suggesting impaired function of the MHC class I antigen processing and presentation pathway. Mutations of the coding region of the HLA-A2 binding Melan-A26-35 peptide or down-regulation of the MHC class I heavy chain, the antigenic peptide TAP, and tapasin could be excluded. However, PCR and immunohistochemical analysis revealed a deficiency of the immunoproteasomes low molecular weight protein 2 and low molecular weight protein 7 in the primary tumor cells, which affects the quantity and quality of generated T-cell epitopes and might explain the resistance to killing. This is supported by our data, demonstrating that the resistance to killing can be partially reversed by pre-exposure of the tumor cells to IFN-gamma, which is known to induce the immunoproteasomes. Overall, this is the first report of an extremely high frequency of tumor-specific CTLs that exhibit competent T-cell-effector functions but fail to lyse the autologous tumor cells. Immunotherapeutic approaches should not only focus on the induction of a robust antitumor immune response, but should also have to target tumor immune escape mechanisms.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In Part I of this review, we have covered basic concepts regarding cardiorespiratory interactions. Here, we put this theoretical framework to practical use. We describe mechanisms underlying Kussmaul's sign and pulsus paradoxus. We review the literature on the use of respiratory variations of blood pressure to evaluate volume status. We show the possibilities of attaining the latter aim by investigating with ultrasonography how the geometry of great veins fluctuates with respiration. We provide a Guytonian analysis of the effects of PEEP on cardiac output. We terminate with some remarks on the potential of positive pressure breathing to induce acute cor pulmonale, and on the cardiovascular mechanisms that at times may underly the failure to wean a patient from the ventilator.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

CONTEXT: Controversy exists regarding the therapeutic benefit and cost effectiveness of photodynamic diagnosis (PDD) with 5-aminolevulinic acid (5-ALA) or hexyl aminolevulinate (HAL) in addition to white-light cystoscopy (WLC) in the management of non-muscle-invasive bladder cancer (NMIBC). OBJECTIVE: To systematically evaluate evidence regarding the therapeutic benefits and economic considerations of PDD in NMIBC detection and treatment. EVIDENCE ACQUISITION: We performed a critical review of PubMed/Medline, Embase, and the Cochrane Library in October 2012 according to the Preferred Reporting Items for Systematic Review and Meta-analysis (PRISMA) statement. Identified reports were reviewed according to the Consolidated Standards of Reporting Trials (CONSORT) and Standards for the Reporting of Diagnostic Accuracy Studies (STARD) criteria. Forty-four publications were selected for inclusion in this analysis. EVIDENCE SYNTHESIS: Included reports used 5-ALA (in 26 studies), HAL (15 studies), or both (three studies) as photosensitising agents. PDD increased the detection of both papillary tumours (by 7-29%) and flat carcinoma in situ (CIS; by 25-30%) and reduced the rate of residual tumours after transurethral resection of bladder tumour (TURBT; by an average of 20%) compared to WLC alone. Superior recurrence-free survival (RFS) rates and prolonged RFS intervals were reported for PDD, compared to WLC in most studies. PDD did not appear to reduce disease progression. Our findings are limited by tumour heterogeneity and a lack of NMIBC risk stratification in many reports or adjustment for intravesical therapy use in most studies. Although cost effectiveness has been demonstrated for 5-ALA, it has not been studied for HAL. CONCLUSIONS: Moderately strong evidence exists that PDD improves tumour detection and reduces residual disease after TURBT compared with WLC. This has been shown to improve RFS but not progression to more advanced disease. Further work to evaluate cost effectiveness of PDD is required.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We analyzed a one-year case series and performed a longitudinal (4 month) cohort analysis of urgent requests made to home care agencies by and for their > or = 65 years old clients in order to estimate the frequency of unscheduled services delivered by home care agencies and to identify risk factors. All 40 home care agencies located in a Swiss region were included in the study and we registered 3,816 urgent requests (75/1,000 > or = 65 years residents per year). Among home care users, the presence of a urinary catheter, incontinence and the need for assistance in bathing were predictors of unscheduled services. Resources should be planned in order to help home care teams to handle unexpected, disruptive clusters of urgent requests that may compromise their scheduled activities.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Single port access (SPA) cholecystectomy is a new concept in laparoscopic surgery. A review of existing results was performed to evaluate critically the current state of SPA with specific reference to feasibility, safety, learning curve, indications and cost-effectiveness. METHODS: All papers identified in MEDLINE until 15 February 2010 and all other relevant papers obtained from cited references were reviewed, without any language restriction. Case reports and series of fewer than three patients were excluded. RESULTS: After selection, 24 studies including 895 patients were analysed. None was randomized. Feasibility seems to be established, with a conversion rate of 2 per cent. SPA was not standardized and there was much technical variation. The learning curve could not be determined. Median follow-up time was 3 (range 0.25-12) months. The overall published complication rate was 5.4 per cent and the biliary complication rate 0.7 per cent. The rate of umbilical complications ranged from 2 to 10 per cent. CONCLUSION: SPA cholecystectomy seems feasible, but standardization, safety and the real benefits for patients need further assessment. Uncontrolled wide adoption of this approach may be responsible for a rise in biliary complications.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Multiple electrode aggregometry (MEA) is a point-of-care test evaluating platelet function and the efficacy of platelet inhibitors. In MEA, electrical impedance of whole blood is measured after addition of a platelet activator. Reduced impedance implies platelet dysfunction or the presence of platelet inhibitors. MEA plays an increasingly important role in the management of perioperative platelet dysfunction. In vitro, midazolam, propofol, lidocaine and magnesium have known antiplatelet effects and these may interfere with MEA interpretation. OBJECTIVE: To evaluate the extent to which MEA is modified in the presence of these drugs. DESIGN: An in-vitro study using blood collected from healthy volunteers. SETTING: Centre Hospitalier Universitaire Vaudois, Lausanne, Switzerland, 2010 to 2011. PATIENTS: Twenty healthy volunteers. INTERVENTION: Measurement of baseline MEA was using four activators: arachidonic acid, ADP, TRAP-6 and collagen. The study drugs were then added in three increasing, clinically relevant concentrations. MAIN OUTCOME MEASURE: MEA was compared with baseline for each study drug. RESULTS: Midazolam, propofol and lidocaine showed no effect on MEA at any concentration. Magnesium at 2.5 mmol l had a significant effect on the ADP and TRAP tests (31 ± 13 and 96 ± 39 AU, versus 73 ± 21 and 133 ± 28 AU at baseline, respectively), and a less pronounced effect at 1 mmol l on the ADP test (39 ± 0 AU). CONCLUSION: Midazolam, propofol and lidocaine do not interfere with MEA measurement. In patients treated with high to normal doses of magnesium, MEA results for ADP and TRAP-tests should be interpreted with caution. TRIAL REGISTRATION: Clinicaltrials.gov (no. NCT01454427).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Multiple organization indices have been used to predict the outcome of stepwise catheter ablation in long-standing persistent atrial fibrillation (AF), however with limited success. Our study aims at developinginnovative organization indices from baseline ECG (i.e. during the procedure, before ablation) in orderto identify the site of AF termination by catheter ablation. Seventeen consecutive male patients (age60 ± 5 years, AF duration 7 ± 5 years) underwent a stepwise catheter ablation. Chest lead V6 was placedin the back (V6b). QRST cancelation was performed from chest leads V1 to V6b. Using an innovativeadaptive harmonic frequency tracking, two measures of AF organization were computed to quantify theharmonics components of ECG activity: (1) the adaptive phase difference variance (APD) between theAF harmonic components as a measure of AF regularity, and (2) and adaptive organization index (AOI)evaluating the cyclicity of the AF oscillations. Both adaptive indices were compared to indices computedusing a time-invariant approach: (1) ECG AF cycle length (AFCL), (2) the spectrum based organizationindex (OI), and (3) the time-invariant phase difference TIPD. Long-standing persistent AF was terminatedinto sinus rhythm or atrial tachycardia in 13/17 patients during stepwise ablation, 11 during left atriumablation (left terminated patients - LT), 2 during the right atrium ablation (right terminated patients -RT), and 4 were non terminated (NT) and required electrical cardioversion. Our findings showed that LTpatients were best separated from RT/NT before ablation by the duration of sustained AF and by AOI onchest lead V1 and APD from the dorsal lead V6b as compared to ECG AFCL, OI and TIPD, respectively. Ourresults suggest that adaptive measures of AF organization computed before ablation perform better thantime-invariant based indices for identifying patients whose AF will terminate during ablation within theleft atrium. These findings are indicative of a higher baseline organization in these patients that could beused to select candidates for the termination of AF by stepwise catheter ablation.© 2013 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Classic climatic models use constitutive laws without any response time. A more realistic approach to the natural processes governing climate dynamics must introduce response time for heat and radiation fluxes. Extended irreversible thermodynamics (EIT) is a good thermodynamical framework for introducing nonclassical constitutive laws. In the present study EIT has been used to analyze a Budyko–Sellers one-dimensional energybalance model developed by G. R. North. The results present self-sustained periodic oscillations when the response time is greater than a critical value. The high-frequency (few kiloyears) damped and nondamped oscillations obtained can be related to abrupt climatic changes without any variation in the external forcing of the system

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This editorial examines the actions undertaken in number 5 and announces two important changes for the numbers 6 and 7, namely frequency and languages. Furthermore, the use of some bibliometric indicators, such as impact factor and refusal rate, is critically analyzed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To evaluate the relationship between changes in body bioelectrical impedance (BI) at 0.5, 50 and kHz and the changes in body weight, as an index of total body water changes, in acutely ill surgical patients during the rapid infusion of isotonic saline solution. DESIGN: Prospective clinical study. SETTING: Multidisciplinary surgical ICU in a university hospital. PATIENTS: Twelve male patients treated for acute surgical illness (multiple trauma n = 5, major surgery n = 7). Selection criteria: stable cardiovascular parameters, normal cardiac function, signs of hypovolemia (CVP < or = 5 mmHg, urine output < 1 ml/kg x h). INTERVENTIONS: After baseline measurements, a 60 min fluid challenge test was performed with normal saline solution, 0.25 ml/kg/min [corrected]. MEASUREMENTS AND RESULTS: Body weight (platform digital scale), total body impedance (four-surface electrode technique; measurements at 0.5, 50 and 100 kHz) and urine output. Fluid retention induced a progressive decrease in BI at 0.5, 50 and 100 kHz, but the changes were significant for BI 0.5 and BI 100 only, from 40 min after the beginning of the fluid therapy onwards. There was a significant negative correlation between changes in water retention and BI 0.5, with individual correlation coefficients ranging from -0.72 to 0.95 (p < 0.01-0.0001). The slopes of the regression lines indicated that for each kg of water change, there was a mean decrease in BI of 18 ohm, but a substantial inter-individual variability was noted. CONCLUSION: BI measured at low frequency can represent a valuable index of acute changes in body water in a group of surgical patients but not in a given individual.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We report millimetre-wave continuum observations of the X-ray binaries Cygnus X-3, SS 433, LSI+61 303, Cygnus X-1 and GRS 1915+105. The observations were carried out with the IRAM 30 m-antenna at 250 GHz (1.25 mm) from 1998 March 14 to March 20. These millimetre measurements are complemented with centimetre observations from the Ryle Telescope, at 15 GHz (2.0 cm) and from the Green Bank Interferometer at 2.25 and 8.3 GHz (13 and 3.6 cm). Both Cygnus X-3 and SS 433 underwent moderate flaring events during our observations, whose main spectral evolution properties are described and interpreted. A significant spectral steepening was observed in both sources during the flare decay, that is likely to be caused by adiabatic expansion, inverse Compton and synchrotron losses. Finally, we also report 250 GHz upper limits for three additional undetected X-ray binary stars: LSI+65 010, LSI+61 235 and X Per.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: Multinuclear magnetic resonance spectroscopy and imaging require a radiofrequency probe capable of transmitting and receiving at the proton and non-proton frequencies. To minimize coupling between probe elements tuned to different frequencies, LC (inductor-capacitor) traps blocking current at the (1) H frequency can be inserted in non-proton elements. This work compares LC traps with LCC traps, a modified design incorporating an additional capacitor, enabling control of the trap reactance at the low frequency while maintaining (1) H blocking. METHODS: Losses introduced by both types of trap were analysed using circuit models. Radiofrequency coils incorporating a series of LC and LCC traps were then built and evaluated at the bench. LCC trap performance was then confirmed using (1) H and (13) C measurements in a 7T human scanner. RESULTS: LC and LCC traps both effectively block interaction between non-proton and proton coils at the proton frequency. LCC traps were found to introduce a sensitivity reduction of 5±2%, which was less than half of that caused by LC traps. CONCLUSION: Sensitivity of non-proton coils is critical. The improved trap design, incorporating one extra capacitor, significantly reduces losses introduced by the trap in the non-proton coil. Magn Reson Med 72:584-590, 2014. © 2013 Wiley Periodicals, Inc.