975 resultados para constant rate infusion


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertação de mestrado integrado em Engenharia e Gestão de Sistemas de Informação

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A newly developed strain rate dependent anisotropic continuum model is proposed for impact and blast applications in masonry. The present model adopted the usual approach of considering different yield criteria in tension and compression. The analysis of unreinforced block work masonry walls subjected to impact is carried out to validate the capability of the model. Comparison of the numerical predictions and test data revealed good agreement. Next, a parametric study is conducted to evaluate the influence of the tensile strengths along the three orthogonal directions and of the wall thickness on the global behavior of masonry walls.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The present study proposes a dynamic constitutive material interface model that includes non-associated flow rule and high strain rate effects, implemented in the finite element code ABAQUS as a user subroutine. First, the model capability is validated with numerical simulations of unreinforced block work masonry walls subjected to low velocity impact. The results obtained are compared with field test data and good agreement is found. Subsequently, a comprehensive parametric analysis is accomplished with different joint tensile strengths and cohesion, and wall thickness to evaluate the effect of the parameter variations on the impact response of masonry walls.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

High transverse momentum jets produced in pp collisions at a centre of mass energy of 7 TeV are used to measure the transverse energy--energy correlation function and its associated azimuthal asymmetry. The data were recorded with the ATLAS detector at the LHC in the year 2011 and correspond to an integrated luminosity of 158 pb−1. The selection criteria demand the average transverse momentum of the two leading jets in an event to be larger than 250 GeV. The data at detector level are well described by Monte Carlo event generators. They are unfolded to the particle level and compared with theoretical calculations at next-to-leading-order accuracy. The agreement between data and theory is good and provides a precision test of perturbative Quantum Chromodynamics at large momentum transfers. From this comparison, the strong coupling constant given at the Z boson mass is determined to be αs(mZ)=0.1173±0.0010 (exp.) +0.0065−0.0026 (theo.).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective To conduct a systematic review about the use of virtual reality (VR) for evaluation, treatment and/or rehabilitation of patients with schizophrenia, focused on: areas, fields and objectives; methodological issues; features of the VR used; viability and efficiency of this resource. Methods Searches were performed about schizophrenia and virtual reality in PsycINFO, Academic Search Complete, MEDLINE Complete, CINAHL with Full Text, Web of Science and Business Source Premier databases, using the following keywords: [“schizophrenia”] AND [“virtual reality” OR “serious game”] AND [“treatment” OR “therapy” OR “rehabilitation”]. The search was carried out between November 2013 and June 2014 without using any search limiters. Results A total of 101 papers were identified, and after the application of exclusion criteria, 33 papers remained. The studies analysed focused on the use of VR for the evaluation of cognitive, social, perceptual and sensory skills, and the vast majority were experimental studies, with virtual reality specifically created for them. All the reviewed papers point towards a reliable and safe use of VR for evaluating and treating cognitive and social deficits in patients with schizophrenia, with different results in terms of generalisation, motivation, assertiveness and task participation rate. Some problems were highlighted, such as its high cost and a constant need for software maintenance. Conclusion The studies show that using the virtual reality may streamline traditional evaluation/rehabilitation programmes, allowing to enhance the results achieved, both in the cognitive and in the social field, helping for the legitimisation of this population’s psycho-social inclusion.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To assess the hemodynamic and vasodilating effects of milrinone lactate (ML) in patients with dilated cardiomyopathy (DCM) and New York Heart Association (NYHA) class III and IV heart failure. METHODS: Twenty patients with DCM and NYHA class III and IV heart failure were studied. The hemodynamic and vasodilating effects of ML, administered intravenously, were evaluated. The following variables were compared before and during drug infusion: cardiac output (CO) and cardiac index (CI); pulmonary capillary wedge pressure (PCWP); mean aortic pressure (MAP); mean pulmonary artery pressure (MPAP); mean right atrial pressure (MRAP); left ventricular systolic and end-diastolic pressures (LVSP and LVEDP, respectively); peak rate of left ventricular pressure rise (dP/dt); systemic vascular resistance (SVR); pulmonary vascular resistance (PVR); and heart rate (HR). RESULTS: All patients showed a significant improvement of the analysed parameters of cardiac performance with an increase of CO and CI; a significant improvement in myocardial contractility (dP/dt) and reduction of the LVEDP; PCWP; PAP; MAP; MRAP; SVR; PVR. Were observed no significant increase in HR occurred. CONCLUSION: Milrinone lactate is an inotropic dilating drug that, when administered intravenously, has beneficial effects on cardiac performance and myocardial contractility. It also promotes reduction of SVR and PVR in patients with DCM and NYHA class III and IV of heart failure.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To assess the presence and the prevalence of arrhythmias and the variability of the heart rate in the medium-term postoperative period following the maze procedure for chronic atrial fibrillation (AF). METHODS: Seventeen patients with a mean age of 51.7±12.9 years, who previously underwent the maze procedure without cryoablation for chronic atrial fibrillation, were evaluated with the 24 hour electrocardiogram (ECG) - Holter monitoring from the 6th month after the operation. Valvular and coronary procedures were concomitantly performed. RESULTS: The mean heart rate during Holter monitoring was 82±8bpm; the maximal heart rate was 126 ± 23bpm and the minimal heart rate 57±7bpm. Sinus rhythm was found in 10 (59%) patients and atrial rhythm was found in 7 (41%). Supraventricular extrasystoles had a rate of 2.3±5.5% of the total number of heartbeats and occurred in 16 (94%) patients. Six (35%) patients showed nonsustained atrial tachycardia. Ventricular extrasystoles, with a rate of 0.8±0.5% of the total heartbeats, occurred in 14 (82%) patients. The chronotropic competence was normal in 9 (53%) patients and attenuated in 8 (47%). The atrioventricular conduction (AV) was unchanged in 13 (76%) patients and there were 4 (24%) cases of first degree atrioventricular block (AVB). CONCLUSION: After the maze procedure, the values for the mean heart rate, AV conduction and chronotropic competence approach the normal range, although some cases show attenuation of the chronotropic response, first degree AV block or benign arrhythmias.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This is the report of a case of fetal tachyarrhythmia with 1:1 atrioventricular conduction detected by pre-natal echocardiography in a fetus at 25-weeks gestation. Adenosine infusion via cordocentesis was performed as a diagnostic test to differentiate between atrioventricular nodal reentrant supraventricular tachyarrhythmia and atrial flutter. After infusion, transient 2:1 atrioventricular dissociation was obtained and the diagnosis of atrial flutter was made. Transplacental therapy with digoxin and amiodarone was then successfully used.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aims: To evaluate the differences in linear and complex heart rate dynamics in twin pairs according to fetal sex combination [male-female (MF), male-male (MM), and female-female (FF)]. Methods: Fourteen twin pairs (6 MF, 3 MM, and 5 FF) were monitored between 31 and 36.4 weeks of gestation. Twenty-six fetal heart rate (FHR) recordings of both twins were simultaneously acquired and analyzed with a system for computerized analysis of cardiotocograms. Linear and nonlinear FHR indices were calculated. Results: Overall, MM twins presented higher intrapair average in linear indices than the other pairs, whereas FF twins showed higher sympathetic-vagal balance. MF twins exhibited higher intrapair average in entropy indices and MM twins presented lower entropy values than FF twins considering the (automatically selected) threshold rLu. MM twin pairs showed higher intrapair differences in linear heart rate indices than MF and FF twins, whereas FF twins exhibited lower intrapair differences in entropy indices. Conclusions: The results of this exploratory study suggest that twins have sex-specific differences in linear and nonlinear indices of FHR. MM twins expressed signs of a more active autonomic nervous system and MF twins showed the most active complexity control system. These results suggest that fetal sex combination should be taken into consideration when performing detailed evaluation of the FHR in twins.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fetal movements and fetal heart rate (FHR) are well-established markers of fetal well-being and maturation of the fetal central nervous system. The purpose of this paper is to review and discuss the available knowledge on fetal movements and heart rate patterns in twin pregnancies. There is some evidence for an association or similarity in fetal movement incidences or FHR patterns between both members of twin pairs. However, the temporal occurrence of these patterns seems to be for the most part asynchronous, especially when stricter criteria are used to define synchrony. The available data suggest that fetal behavior is largely independent of sex combination, fetal position, and presentation. Conversely, chorionicity appears to have some influence on fetal behavior, mainly before 30 weeks of gestation. There is preliminary evidence for the continuity of inter-individual differences in fetal activity and FHR patterns over pregnancy. Comparisons between studies are limited by large methodological differences and absence of uniform concepts and definitions. Future studies with high methodological quality are needed to provide a more comprehensive knowledge of normal fetal behavior in twin pregnancy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The decision support models in intensive care units are developed to support medical staff in their decision making process. However, the optimization of these models is particularly difficult to apply due to dynamic, complex and multidisciplinary nature. Thus, there is a constant research and development of new algorithms capable of extracting knowledge from large volumes of data, in order to obtain better predictive results than the current algorithms. To test the optimization techniques a case study with real data provided by INTCare project was explored. This data is concerning to extubation cases. In this dataset, several models like Evolutionary Fuzzy Rule Learning, Lazy Learning, Decision Trees and many others were analysed in order to detect early extubation. The hydrids Decision Trees Genetic Algorithm, Supervised Classifier System and KNNAdaptive obtained the most accurate rate 93.2%, 93.1%, 92.97% respectively, thus showing their feasibility to work in a real environment.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We report the case of a 57-year-old male patient with severe low back pain during streptokinase infusion administered to treat typical chest pain and elevation of the ST segment in the inferior wall. We reviewed the literature, emphasizing the differential diagnosis, the pathophysiology, and management of the event.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Particulate fouling tests were carried out using kaolin-water suspensions flowing through an annular heat exchanger with a copper inner tube. The flow rate was changed from test to test, but the fluid temperature and pH, as well as the particle concentration, were maintained constant. In the lower range of fluid velocities (<0.5 m/s), the deposition process seemed to be controlled by mass transfer. The corresponding experimental transport fluxes were compared to the predictions obtained with several models, showing that diffusion governed particle transport. The absolute values of the mass transfer fluxes and their dependences on the Reynolds number were satisfactorily predicted by some of the models.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To assess the short- and long-term results of the use of streptokinase (SK) for the treatment of thromboses in cardiac valvular prostheses. METHODS: Seventeen patients with cardiac prosthetic thrombosis diagnosed by clinical, echocardiographic, and radioscopic findings underwent fibrinolytic treatment with a streptokinase bolus of 250,000 U followed by 100.000 U/hour. Short- and long-term results were assessed by radioscopy and echocardiography. RESULTS: Of the 17 patients, 12 had mechanical double-disk prostheses (4 aortic, 6 mitral, 2 tricuspid), 4 had single-disk prostheses (2 aortic, 1 mitral, and 1 tricuspid), and 1 had a tricuspid bioprosthesis. The success rate was 64.8%, the partial success rate was 17.6%, and the nonsuccess rate was 17.6%. All patients with a double-disk prosthesis responded, completely or partially, to the treatment. None of the patients with a single-disk prosthesis had complete resolution of the thrombosis. The time of streptokinase infusion ranged from 6 to 80 hours (mean of 56 h). The mortality rate due to the use of streptokinase was 5.8% and was secondary to cerebral bleeding. During streptokinase infusion, 3 (17.6%) embolic episodes occurred as follows: 1 cerebral, 1 peripheral, and 1 coronary. The rethrombosis index was 33% in a mean follow-up of 42 months. CONCLUSION: The use of fibrinolytic agents was effective and relatively safe in patients with primary thrombosis of a double-disk prosthesis. A fatal hemorrhagic complication occurred in 1 (5.8%) patient, and embolic complications occurred in 3 (17.6%) patients. In a mean 42-month follow-up, 67% of the patients were free from rethrombosis.