954 resultados para concave refractive microlens array


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Refractive losses in laser-produced plasmas used as gain media are caused by electron density gradients, and limit the energy transport range. The pump pulse is thus deflected from the high-gain region and the short wavelength laser signal also steers away, causing loss of collimation. A Hohlraum used as a target makes the plasma homogeneous and can mitigate refractive losses by means of wave-guiding. A computational study combining a hydrodynamics code and an atomic physics code is presented, which includes a ray-tracing modeling based on the eikonal theory of the trajectory equation. This study presents gain calculations based on population inversion produced by free-electron collisions exciting bound electrons into metastable levels in the 3d94d1(J = 0) → 3d94p1(J = 1) transition of Ni-like Sn. Further, the Hohlraum suggests a dramatic enhancement of the conversion efficiency of collisionally excited x-ray lasing for Ni-like Sn.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

For clinical optoacoustic imaging, linear probes are preferably used because they allow versatile imaging of the human body with real-time display and free-hand probe guidance. The two-dimensional (2-D) optoacoustic image obtained with this type of probe is generally interpreted as a 2-D cross-section of the tissue just as is common in echo ultrasound. We demonstrate in three-dimensional simulations, phantom experiments, and in vivo mouse experiments that for vascular imaging this interpretation is often inaccurate. The cylindrical blood vessels emit anisotropic acoustic transients, which can be sensitively detected only if the direction of acoustic radiation coincides with the probe aperture. Our results reveal for this reason that the signal amplitude of different blood vessels may differ even if the vessels have the same diameter and initial pressure distribution but different orientation relative to the imaging plane. This has important implications for the image interpretation, for the probe guidance technique, and especially in cases when a quantitative reconstruction of the optical tissue properties is required.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A CE system featuring an array of 16 contactless conductivity detectors was constructed. The detectors were arranged along 70 cm length of a capillary with 100 cm total length and allow the monitoring of separation processes. As the detectors cannot be accommodated on a conventional commercial instrument, a purpose built set-up employing a sequential injection manifold had to be employed for automation of the fluid handling. Conductivity measurements can be considered universal for electrophoresis and thus any changes in ionic composition can be monitored. The progress of the separation of Na(+) and K(+) is demonstrated. The potential of the system to the study of processes in CZE is shown in two examples. The first demonstrates the differences in the developments of peaks originating from a sample plug with a purely aqueous background to that of a plug containing the analyte ions in the buffer. The second example visualizes the opposite migration of cations and anions from a sample plug that had been placed in the middle of the capillary.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We report about a lung-on-chip array that mimics the pulmonary parenchymal environment, including the thin, alveolar barrier and the three-dimensional cyclic strain induced by the breathing movements. A micro-diaphragm used to stretch the alveolar barrier is inspired by the in-vivo diaphragm, the main muscle responsible for inspiration. The design of this device aims not only at best reproducing the in-vivo conditions found in the lung parenchyma, but also at making its handling easy and robust. An innovative concept, based on the reversible bonding of the device, is presented that enables to accurately control the concentration of cells cultured on the membrane by easily accessing both sides of the membranes. The functionality of the alveolar barrier could be restored by co-culturing epithelial and endothelial cells that formed tight monolayers on each side of a thin, porous and stretchable membrane. We showed that cyclic stretch significantly affects the permeability properties of epithelial cell layers. Furthermore, we could also demonstrate that the strain influences the metabolic activity and the cytokine secretion of primary human pulmonary alveolar epithelial cells obtained from patients. These results demonstrate the potential of this device and confirm the importance of the mechanical strain induced by the breathing in pulmonary research.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

HYPOTHESIS To evaluate the feasibility and the results of insertion of two types of electrode arrays in a robotically assisted surgical approach. BACKGROUND Recent publications demonstrated that robot-assisted surgery allows the implantation of free-fitting electrode arrays through a cochleostomy drilled via a narrow bony tunnel (DCA). We investigated if electrode arrays from different manufacturers could be used with this approach. METHODS Cone-beam CT imaging was performed on fivecadaveric heads after placement of fiducial screws. Relevant anatomical structures were segmented and the DCA trajectory, including the position of the cochleostomy, was defined to target the center of the scala tympani while reducing the risk of lesions to the facial nerve. Med-El Flex 28 and Cochlear CI422 electrodes were implanted on both sides, and their position was verified by cone-beam CT. Finally, temporal bones were dissected to assess the occurrence of damage to anatomical structures during DCA drilling. RESULTS The cochleostomy site was directed in the scala tympani in 9 of 10 cases. The insertion of electrode arrays was successful in 19 of 20 attempts. No facial nerve damage was observed. The average difference between the planned and the postoperative trajectory was 0.17 ± 0.19 mm at the level of the facial nerve. The average depth of insertion was 305.5 ± 55.2 and 243 ± 32.1 degrees with Med-El and Cochlear arrays, respectively. CONCLUSIONS Robot-assisted surgery is a reliable tool to allow cochlear implantation through a cochleostomy. Technical solutions must be developed to improve the electrode array insertion using this approach.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We consider the problem of nonparametric estimation of a concave regression function F. We show that the supremum distance between the least square s estimatorand F on a compact interval is typically of order(log(n)/n)2/5. This entails rates of convergence for the estimator’s derivative. Moreover, we discuss the impact of additional constraints on F such as monotonicity and pointwise bounds. Then we apply these results to the analysis of current status data, where the distribution function of the event times is assumed to be concave.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We introduce a new fiber-optical approach for reflection based refractive index mapping. Our approach leads to improved stability and reliability over existing free-space confocal instruments and significantly cuts alignment efforts and reduces the number of components needed. Other than properly cleaved fiber end-faces, this setup requires no additional sample preparation. The instrument is calibrated by means of a set of samples with known refractive indices. The index steps of commercially available fibers are measured accurately down to < 10⁻³. The precision limit of the instrument is currently of the order of 10⁻⁴.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Magnetic resonance imaging (MRI) is a non-invasive technique that offers excellent soft tissue contrast for characterizing soft tissue pathologies. Diffusion tensor imaging (DTI) is an MRI technique that has shown to have the sensitivity to detect subtle pathology that is not evident on conventional MRI. ^ Rats are commonly used as animal models in characterizing the spinal cord pathologies including spinal cord injury (SCI), cancer, multiple sclerosis, etc. These pathologies could affect both thoracic and cervical regions and complete characterization of these pathologies using MRI requires DTI characterization in both the thoracic and cervical regions. Prior to the application of DTI for investigating the pathologic changes in the spinal cord, it is essential to establish DTI metrics in normal animals. ^ To date, in-vivo DTI studies of rat spinal cord have used implantable coils for high signal-to-noise ratio (SNR) and spin-echo pulse sequences for reduced geometric distortions. Implantable coils have several disadvantages including: (1) the invasive nature of implantation, (2) loss of SNR due to frequency shift with time in the longitudinal studies, and (3) difficulty in imaging the cervical region. While echo planar imaging (EPI) offers much shorter acquisition times compared to spin-echo imaging, EPI is very sensitive to static magnetic field inhomogeneities and the existing shimming techniques implemented on the MRI scanner do not perform well on spinal cord because of its geometry. ^ In this work, an integrated approach has been implemented for in-vivo DTI characterization of rat spinal cord in the thoracic and cervical regions. A three element phased array coil was developed for improved SNR and extended spatial coverage. A field-map shimming technique was developed for minimizing the geometric distortions in EPI images. Using these techniques, EPI based DWI images were acquired with optimized diffusion encoding scheme from 6 normal rats and the DTI-derived metrics were quantified. ^ The phantom studies indicated higher SNR and smaller bias in the estimated DTI metrics than the previous studies in the cervical region. In-vivo results indicated no statistical difference in the DTI characteristics of either gray matter or white matter between the thoracic and cervical regions. ^

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background. Over 39.9% of the adult population forty or older in the United States has refractive error, little is known about the etiology of this condition and associated risk factors and their entailed mechanism due to the paucity of data regarding the changes of refractive error for the adult population over time.^ Aim. To evaluate risk factors over a long term, 5-year period, in refractive error changes among persons 43 or older by testing the hypothesis that age, gender, systemic diseases, nuclear sclerosis and baseline refractive errors are all significantly associated with refractive errors changes in patients at a Dallas, Texas private optometric office.^ Methods. A retrospective chart review of subjective refraction, eye health, and self-report health history was done on patients at a private optometric office who were 43 or older in 2000 who had eye examinations both in 2000 and 2005. Aphakic and pseudophakic eyes were excluded as well as eyes with best corrected Snellen visual acuity of 20/40 and worse. After exclusions, refraction was obtained on 114 right eyes and 114 left eyes. Spherical equivalent (sum of sphere + ½ cylinder) was used as the measure of refractive error.^ Results. Similar changes in refractive error were observed for the two eyes. The 5-year change in spherical power was in a hyperopic direction for younger age groups and in a myopic direction for older subjects, P<0.0001. The gender-adjusted mean change in refractive error in right eyes of persons aged 43 to 54, 55 to 64, 65 to 74, and 75 or older at baseline was +0.43D, +0.46 D, -0.09 D, and -0.23D, respectively. Refractive change was strongly related to baseline nuclear cataract severity; grades 4 to 5 were associated with a myopic shift (-0.38 D, P< 0.0001). The mean age-adjusted change in refraction was +0.27 D for hyperopic eyes, +0.56 D for emmetropic eyes, and +0.26 D for myopic eyes.^ Conclusions. This report has documented refractive error changes in an older population and confirmed reported trends of a hyperopic shift before age 65 and a myopic shift thereafter associated with the development of nuclear cataract.^

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Precisely determined refractive indices of glass shards from 32 ash-rich, volcaniclastic sediments, mostly turbidites interbedded with nonvolcanic sediments in the Mariana Trough, range from 1.480 to 1.585 (corresponding to SiO2 ca. 75 to 49%), with most in the range 1.500 to 1.540 (SiO2 ca. 70-62%) and a second, smaller mode between ca. 1.560 and 1.585 (57 to 49% SiO2). Shards are almost exclusively colorless from 1.480 to ca. 1.530, light brown with minor colorless and green tones between 1.530 and 1.560, and dominantly brown at higher refractive indices. Tubular pumice shards are more common at higher silica percentages and non- to poorly-vesicular cuniform shards at low SiO2 values, but there is no clear correlation between shape and composition of shards. About half of the samples have bimodal shard populations with silica differences ranging up to 20 percent; unimodal layers have a range of up to about 7 percent SiO2. Of 21 samples in which one type of shard dominates, seven have the main mode in the rhyolitic composition (>69% SiO2), eight in the intermediate range (56 to 69% SiO2), and five in mafic composition (SiO2 <53%). These unusually abundant mafic shards occur mainly in site survey piston cores, SP-IA and 4E, and in Holes 454, 456, 458, and 459B. These are the sites closest to the present arc. Hole 453, containing by far the most vitric tuff turbidites, shows a gradual increase in silica content of ash layers upward to the hole from Cores 36 to 19 (about 4.6 to 3.0 Ma). A drastic decrease in ash-rich beds in the younger (Pleistocene) part of this hole was noted by the shipboard party (see site chapter, Site 453) and was interpreted by them as indicating increasing distance from the arc volcanoes as the trough opened. The increase in silica in ashes from the early to the late Pliocene at Site 453 could be interpreted in the same way and might indicate that the trough started to open in early Pliocene time.