870 resultados para computerized electrocardiography


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Information processing speed, as measured by elementary cognitive tasks, is correlated with higher order cognitive ability so that increased speed relates to improved cognitive performance. The question of whether the genetic variation in Inspection Time (IT) and Choice Reaction Time (CRT) is associated with IQ through a unitary factor was addressed in this multivariate genetic study of IT, CRT, and IQ subtest scores. The sample included 184 MZ and 206 DZ twin pairs with a mean age of 16.2 years (range 15-18 years). They were administered a visual (pi-figure) IT task, a two-choice RT task, five computerized subtests of the Multidimensional Aptitude Battery, and the digit symbol substitution subtest from the WAIS-R. The data supported a factor model comprising a general, three group (verbal ability, visuospatial ability, broad speediness), and specific genetic factor structure, a shared environmental factor influencing all tests but IT, plus unique environmental factors that were largely specific to individual measures. The general genetic factor displayed factor loadings ranging between 0.35 and 0.66 for the IQ subtests, with IT and CRT loadings of -0.47 and -0.24, respectively. Results indicate that a unitary factor is insufficient to describe the entire relationship between cognitive speed measures and all IQ subtests, with independent genetic effects explaining further covariation between processing speed (especially CRT) and Digit Symbol.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objectives: The aim of this study was to investigate the temperature profile of home intravenous (iv) antibiotic reservoirs and the stability of 16 megaunits of benzylpenicillin sodium in 120 mL of sodium chloride 0.9% at constant and variable temperatures. Methods: A Tinytag computerized thermometer recorded temperatures every minute in the home iv antibiotic reservoir pouches of nine patients over a 24 h period. Similar bags containing benzylpenicillin sodium (16 megaunits) were maintained either at a constant 36degreesC, 26degreesC or 21-22degreesC or were worn in a pouch by five healthy volunteers for a 24 h period. Other bags were stored at 3-5degreesC for 10 days. The bags were sampled at timed intervals and benzylpenicillin concentrations assayed by HPLC. Results: Median temperatures recorded in the infusion bags worn by the nine patients were in the range 16.7-34.1degreesC. For infusion bags maintained at 36degreesC, 26degreesC and 21-22degreesC, the concentrations of benzylpenicillin dropped below 90% of the initial concentration at a mean time of 5 h 18 min, 12 h 54 min and 13 h 20 min, respectively, whereas for bags worn by the healthy volunteers the mean time for 10% loss of benzylpenicillin was 9 h 20 min. In contrast, at 3-5degreesC, concentrations of benzylpenicillin only dropped below 90% of the initial concentration at 8 days. Conclusions: Significant temperature-dependent degradation of benzylpenicillin occurs during continuous home iv antibiotic programme infusions, which could result in loss of efficacy.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper highlights the importance of design expertise, for designing liquid retaining structures, including subjective judgments and professional experience. Design of liquid retaining structures has special features different from the others. Being more vulnerable to corrosion problem, they have stringent requirements against serviceability limit state of crack. It is the premise of the study to transferring expert knowledge in a computerized blackboard system. Hybrid knowledge representation schemes, including production rules, object-oriented programming, and procedural methods, are employed to express engineering heuristics and standard design knowledge during the development of the knowledge-based system (KBS) for design of liquid retaining structures. This approach renders it possible to take advantages of the characteristics of each method. The system can provide the user with advice on preliminary design, loading specification, optimized configuration selection and detailed design analysis of liquid retaining structure. It would be beneficial to the field of retaining structure design by focusing on the acquisition and organization of expert knowledge through the development of recent artificial intelligence technology. (C) 2003 Elsevier Ltd. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

There is evidence in the literature for both a congenital and a post-traumatic aetiology for os odontoideum. In no series published to date has CT been used to aid in the diagnosis. This is a prospective study of the history of trauma and presence of diagnostic features on CT of 18 consecutive cases with os odontoideum. Our objective was to derive clinically useful radiological features enabling accurate differentiation between congenital and post-traumatic aetiologies. A mid-sagittal CT reconstruction of the atlanto-dens joint was obtained. Hypertrophy of the anterior arch of the atlas was quantified by measurement of the arch-peg-area ratio. The presence of dysplastic features (a positive jigsaw sign) of the atlanto-axial joint were noted. These included narrowing of the cartilage space and interdigitation of the two joint surfaces. A history of a potential traumatic aetiology was only obtained in one of the 18 (6%) in our series. A significant elevation of the arch-peg ratio was found when comparing this series to 85 controls. And a positive jigsaw sign was observed in 75% of cases. These features were not seen in paediatric cases of atlanto-axial instability, including odontoid non-union. In conclusion, an elevated arch-peg ratio and the presence of a jigsaw sign are sensitive and specific diagnostic criteria for os odontoideum. This series supports a congenital aetiology for this condition.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

An X-ray visualization technique has been used for the quantitative determination of local liquid holdups distribution and liquid holdup hysteresis in a nonwetting two-dimensional (2-D) packed bed. A medical diagnostic X-ray unit has been used to image the local holdups in a 2-D cold model having a random packing of expanded polystyrene beads. An aqueous barium chloride solution was used as a fluid to achieve good contrast on X-ray images. To quantify the local liquid holdup, a simple calibration technique has been developed that can be used for most of the radiological methods such as gamma ray and neutron radiography. The global value of total liquid holdup, obtained by X-ray method, has been compared with two conventional methods: drainage and tracer response. The X-ray technique, after validation, has been used to visualize and quantify, the liquid hysteresis phenomena in a packed bed. The liquid flows in preferred paths or channels that carry droplets/rivulets of increasing size and number as the liquid flow rate is increased. When the flow is reduced, these paths are retained and the higher liquid holdup that persists in these regions leads to the holdup hysteresis effect. Holdup in some regions of the packed bed may be an order of magnitude higher than average at a particular flow rate. (c) 2005 American Institute of Chemical Engineers

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Aims Prior research is limited with regard to the diagnostic and prognostic accuracy of commonplace cardiac imaging modalities in women. The aim of this study was to examine 5-year mortality in 4234 women and 6898 men undergoing exercise or dobutamine stress echocardiography at three hospitals. Methods and results Univariable and multivariable Cox proportional hazards models were used to estimate time to cardiac death in this multi-centre, observational registry. Of the 11 132 patients, women had a greater frequency of cardiac risk factors (P < 0.0001). However, men more often had a history of coronary disease including a greater frequency of echocardiographic wall motion abnormalities (P < 0.0001). During 5 years of follow-up, 103 women and 226 men died from ischaernic heart disease (P < 0.0001). Echocardiographic estimates of left ventricular function (P < 0.0001) and the extent of ischaernic watt motion abnormalities (P < 0.0001) were highly predictive of cardiac death. Risk-adjusted 5-year survival was 99.4, 97.6, and 95% for exercising women with no, single, and multi-vessel ischaemia (P < 0.0001). For women undergoing dobutamine stress, 5-year survival was 95, 89, and 86.6% for those with 0, 1, and 2-3 vessel ischaemia (P < 0.0001). Exercising men had a 2.0-fold higher risk at every level of worsening ischaemia (P < 0.0001). Significantly worsening cardiac survival was noted for the 1568 men undergoing dobutamine stress echocardiography (P < 0.0001); no ischaemia was associated with 92% 5-year survival as compared with death rates of &GE; 16% for men with ischaemia on dobutamine stress echocardiography (P < 0.0001). Conclusion Echocardiographic measures of inducible wall motion abnormalities and global and regional left ventricutar function are highly predictive of long-term outcome for women and men alike.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Dizziness and or unsteadiness, associated with episodes of loss of balance, are frequent complaints in those suffering from persistent problems following a whiplash injury. Research has been inconclusive with respect to possible aetiology, discriminative tests and analyses used. The aim of this pilot research was to identify the test conditions and the most appropriate method for the analysis of sway that may differentiate subjects with persistent whiplash associated disorders (WAD) from healthy controls. The six conditions of the Clinical Test for Sensory Interaction in Balance was performed in both comfortable and tandem stance in 20 subjects with persistent WAD compared to 20 control subjects. The analyses were carried out using a traditional method of measurement, total sway distance, to results obtained from the use of wavelet analysis. Subjects with WAD were significantly less able to complete the tandem stance tests on a firm surface than controls. In comfortable stance, using wavelet analysis, significant differences between subjects with WAD and the control group were evident in total energy of the trace for all test conditions apart from eyes open on the firm surface. In contrast, the results of the analysis using total sway distance revealed no significant differences between groups across all six conditions. Wavelet analysis may be more appropriate for detecting disturbances in balance in whiplash subjects because the technique allows separation of the noise from the underlying systematic effect of sway. These findings will be used to direct future studies on the aeitiology of balance disturbances in WAD. (c) 2004 Elsevier B.V. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Knowledge of the key of a musical passage is a pre-requisite for all the analyses that require functional labelling. In the past, people from either a musical or AI background have tended to solve the problem by means of implementing a computerized version of musical analysis. Previous attempts are discussed and then attention is focused on a non-analytical solution first reported by J.A.Gabura. A practical way to carry it out is discussed as well as its limitations in relation to examples. References are made to the MusicXML format as needed. © Springer-Verlag Berlin Heidelberg 2006.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background. We describe the development, reliability and applications of the Diagnostic Interview for Psychoses (DIP), a comprehensive interview schedule for psychotic disorders. Method. The DIP is intended for use by interviewers with a clinical background and was designed to occupy the middle ground between fully structured, lay-administered schedules, and semi-structured., psychiatrist-administered interviews. It encompasses four main domains: (a) demographic data; (b) social functioning and disability; (c) a diagnostic module comprising symptoms, signs and past history ratings; and (d) patterns of service utilization Lind patient-perceived need for services. It generates diagnoses according to several sets of criteria using the OPCRIT computerized diagnostic algorithm and can be administered either on-screen or in a hard-copy format. Results. The DIP proved easy to use and was well accepted in the field. For the diagnostic module, inter-rater reliability was assessed on 20 cases rated by 24 clinicians: good reliability was demonstrated for both ICD-10 and DSM-III-R diagnoses. Seven cases were interviewed 2-11 weeks apart to determine test-retest reliability, with pairwise agreement of 0.8-1.0 for most items. Diagnostic validity was assessed in 10 cases, interviewed with the DIP and using the SCAN as 'gold standard': in nine cases clinical diagnoses were in agreement. Conclusions. The DIP is suitable for use in large-scale epidemiological studies of psychotic disorders. as well as in smaller Studies where time is at a premium. While the diagnostic module stands on its own, the full DIP schedule, covering demography, social functioning and service utilization makes it a versatile multi-purpose tool.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Despite the number of computer-assisted methods described for the derivation of steady-state equations of enzyme systems, most of them are focused on strict steady-state conditions or are not able to solve complex reaction mechanisms. Moreover, many of them are based on computer programs that are either not readily available or have limitations. We present here a computer program called WinStes, which derives equations for both strict steady-state systems and those with the assumption of rapid equilibrium, for branched or unbranched mechanisms, containing both reversible and irreversible conversion steps. It solves reaction mechanisms involving up to 255 enzyme species, connected by up to 255 conversion steps. The program provides all the advantages of the Windows programs, such as a user-friendly graphical interface, and has a short computation time. WinStes is available free of charge on request from the authors. (c) 2006 Elsevier Inc. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this study was to identify a set of genetic polymorphisms that efficiently divides methicillin-resistant Staphylococcus aureus (MRSA) strains into groups consistent with the population structure. The rationale was that such polymorphisms could underpin rapid real-time PCR or low-density array-based methods for monitoring MRSA dissemination in a cost-effective manner. Previously, the authors devised a computerized method for identifying sets of single nucleoticle polymorphisms (SNPs) with high resolving power that are defined by multilocus sequence typing (MLST) databases, and also developed a real-time PCR method for interrogating a seven-member SNP set for genotyping S. aureus. Here, it is shown that these seven SNPs efficiently resolve the major MRSA lineages and define 27 genotypes. The SNP-based genotypes are consistent with the MRSA population structure as defined by eBURST analysis. The capacity of binary markers to improve resolution was tested using 107 diverse MRSA isolates of Australian origin that encompass nine SNP-based genotypes. The addition of the virulence-associated genes cna, pvl and bbplsdrE, and the integrated plasmids pT181, p1258 and pUB110, resolved the nine SNP-based genotypes into 21 combinatorial genotypes. Subtyping of the SCCmec locus revealed new SCCmec types and increased the number of combinatorial genotypes to 24. It was concluded that these polymorphisms provide a facile means of assigning MRSA isolates into well-recognized lineages.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This work has, as its objective, the development of non-invasive and low-cost systems for monitoring and automatic diagnosing specific neonatal diseases by means of the analysis of suitable video signals. We focus on monitoring infants potentially at risk of diseases characterized by the presence or absence of rhythmic movements of one or more body parts. Seizures and respiratory diseases are specifically considered, but the approach is general. Seizures are defined as sudden neurological and behavioural alterations. They are age-dependent phenomena and the most common sign of central nervous system dysfunction. Neonatal seizures have onset within the 28th day of life in newborns at term and within the 44th week of conceptional age in preterm infants. Their main causes are hypoxic-ischaemic encephalopathy, intracranial haemorrhage, and sepsis. Studies indicate an incidence rate of neonatal seizures of 0.2% live births, 1.1% for preterm neonates, and 1.3% for infants weighing less than 2500 g at birth. Neonatal seizures can be classified into four main categories: clonic, tonic, myoclonic, and subtle. Seizures in newborns have to be promptly and accurately recognized in order to establish timely treatments that could avoid an increase of the underlying brain damage. Respiratory diseases related to the occurrence of apnoea episodes may be caused by cerebrovascular events. Among the wide range of causes of apnoea, besides seizures, a relevant one is Congenital Central Hypoventilation Syndrome (CCHS) \cite{Healy}. With a reported prevalence of 1 in 200,000 live births, CCHS, formerly known as Ondine's curse, is a rare life-threatening disorder characterized by a failure of the automatic control of breathing, caused by mutations in a gene classified as PHOX2B. CCHS manifests itself, in the neonatal period, with episodes of cyanosis or apnoea, especially during quiet sleep. The reported mortality rates range from 8% to 38% of newborn with genetically confirmed CCHS. Nowadays, CCHS is considered a disorder of autonomic regulation, with related risk of sudden infant death syndrome (SIDS). Currently, the standard method of diagnosis, for both diseases, is based on polysomnography, a set of sensors such as ElectroEncephaloGram (EEG) sensors, ElectroMyoGraphy (EMG) sensors, ElectroCardioGraphy (ECG) sensors, elastic belt sensors, pulse-oximeter and nasal flow-meters. This monitoring system is very expensive, time-consuming, moderately invasive and requires particularly skilled medical personnel, not always available in a Neonatal Intensive Care Unit (NICU). Therefore, automatic, real-time and non-invasive monitoring equipments able to reliably recognize these diseases would be of significant value in the NICU. A very appealing monitoring tool to automatically detect neonatal seizures or breathing disorders may be based on acquiring, through a network of sensors, e.g., a set of video cameras, the movements of the newborn's body (e.g., limbs, chest) and properly processing the relevant signals. An automatic multi-sensor system could be used to permanently monitor every patient in the NICU or specific patients at home. Furthermore, a wire-free technique may be more user-friendly and highly desirable when used with infants, in particular with newborns. This work has focused on a reliable method to estimate the periodicity in pathological movements based on the use of the Maximum Likelihood (ML) criterion. In particular, average differential luminance signals from multiple Red, Green and Blue (RGB) cameras or depth-sensor devices are extracted and the presence or absence of a significant periodicity is analysed in order to detect possible pathological conditions. The efficacy of this monitoring system has been measured on the basis of video recordings provided by the Department of Neurosciences of the University of Parma. Concerning clonic seizures, a kinematic analysis was performed to establish a relationship between neonatal seizures and human inborn pattern of quadrupedal locomotion. Moreover, we have decided to realize simulators able to replicate the symptomatic movements characteristic of the diseases under consideration. The reasons is, essentially, the opportunity to have, at any time, a 'subject' on which to test the continuously evolving detection algorithms. Finally, we have developed a smartphone App, called 'Smartphone based contactless epilepsy detector' (SmartCED), able to detect neonatal clonic seizures and warn the user about the occurrence in real-time.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A velocidade da informação e do conhecimento instaurou na sociedade contemporânea uma constante busca pela melhoria dos processos informacionais, com vistas a garantir maior rapidez nos processamentos e resultados. No universo público, as exigências caminham de modo similar, sob o olhar do eleitor cidadão, portanto, a proposta da pesquisa é promover um panorama do sistema eletrônico de votação brasileiro, mais precisamente a Urna Eletrônica e transitar desde a concepção do projeto nos idos da década de 90 até o momento atual, apontando um olhar científico para as ações comunicacionais do Tribunal Superior Eleitoral (TSE), no sentido de promover campanhas publicitárias para fomentar a conscientização do sistema informatizado de voto pelos eleitores, supostamente mais rápido e eficiente. A pesquisa utiliza para fins descritivos múltiplas visões da comunicação da urna: por intermédio do órgão mantenedor, os políticos, diretamente envolvidos no pleito competitivo e os consultores políticos, atuantes nas estratégias de bastidores das campanhas eleitorais. Essa diversidade de visões e posições acerca da credibilidade do sistema busca propiciar a pesquisa um caráter de macro compreensão dos impactos de um sistema informatizado em um ambiente democrático.(AU)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Esta dissertação tem como objetivo analisar a minha ação docente em aulas de matemática, que implicam a utilização de dois tipos de jogos eletrônicos em ambiente informatizado. Para tanto, foram observadas as ações e reações dos educandos ao utilizarem os jogos eletrônicos, a manifestação do pensamento, do raciocínio e de estratégias para a solução dos problemas encontrados. A metodologia desta pesquisa caracterizou-se pela natureza qualitativa - aos moldes da pesquisa-ação - numa modalidade narrativa, desenvolvendo-se pelas pesquisas bibliográficas e de campo. A coleta dos dados foi realizada por meio de entrevista semi-estruturada aplicada a nove sujeitos pertencentes a duas classes de 5ª série do ensino fundamental, em sua segunda fase. A análise dos resultados e das observações em sala de aula possibilitou concluir que os jogos, de uma maneira geral, e os eletrônicos, de forma específica, podem ser utilizados como ferramentas úteis no ensino da Matemática, proporcionando um aprendizado prazeroso, sob a orientação criteriosa do professor.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

O propósito desta pesquisa foi estudar algumas análises faciais utilizadas para diagnóstico ortodôntico e verificar a concordância entre norma lateral e frontal na avaliação da agradabilidade facial para os grupos leigos e profissionais, a concordância entre estes grupos na avaliação da agradabilidade facial nas normas lateral e frontal, bem como verificar a associação entre agradabilidade facial e Proporção Áurea, agradabilidade facial e Padrão Facial e entre Padrão Facial e Proporção Áurea. Utilizou-se 208 fotografias faciais padronizadas (104 laterais e 104 frontais) de 104 indivíduos escolhidos aleatoriamente, que primeiramente foram classificadas em agradável , aceitável e desagradável por dois grupos distintos: grupo Ortodontia e grupo Leigos . As fotografias laterais e frontais foram submetidas a medidas de Proporção Áurea Facial por meio de programa computadorizado e os indivíduos foram classificados quanto ao Padrão Facial pelo seu aspecto lateral. Após análise estatística, verificou-se que não houve concordância entre as variáveis da avaliação de agradabilidade estudadas, bem como não houve associação entre Proporção Áurea com agradabilidade facial ou com Padrão Facial. Entre agradabilidade facial e Padrão Facial, observou-se para a norma lateral associação fortemente positiva, porém para a frontal não houve associação para ambos os grupos de avaliadores.