880 resultados para cold rolling
Resumo:
A free-running, temperature stabilized diode laser has been injection-locked to an external cavity diode laser for use in cold Rydberg atom experiments. Cold rubidium atoms in a magneto-optical trap (MOT) are excited to Rydberg states using a 10 ns laser pulse. The Rydberg atoms spontaneously ionize due to dipole forces, and the collisional ionization dynamics are observed as a function of atom density and principal quantum number of the Rydberg state, n. The injection-locked diode laser will be used as a repumper in conjunction with a dark spontaneous-force optical trap (SPOT) to increase the Rydberg state density. We report on the design of the injection-locked laser system.
Resumo:
Why merger talks collapse: an exploratory study about contributing factors behind ‘wedding cold feet' and deal making failure in Mergers and Acquisitions from the perspective of active deal making professionals in Brazil. One basic question encouraged this study: after all the effort, expectations and money usually invested in dealmaking, why are so many transactions simply abandoned, even when the benefits are clear for the business, shareholders, customers and employees?
Resumo:
Foi avaliado o efeito do processo de defumação a quente (45-90ºC/5 horas) e a frio (27-45ºC/10 horas) nas propriedades organolépticas, no rendimento e na composição dos filés de matrinxã (Brycon cephalus). Não houve diferença significativa no rendimento de filés defumados e não-defumados. As perdas no processo de defumação foram significativamente maiores para defumação a quente (19,37%) em comparação à defumação a frio (17,08%). O processo de defumação reduziu a umidade (in natura = 72,91%; defumado a quente = 58,51%; e defumado a frio = 59,68%) e aumentou os teores de proteína bruta, lipídios e cinzas. Houve diferença significativa somente nos teores de proteína no defumado a quente (28,07%) e defumado a frio (27,14%). O processo a frio resultou em melhor aparência e cor de filé, enquanto o processo a quente melhorou o sabor, o teor de sal e a aparência geral. O aroma e a textura não diferiram significativamente entre os processos. O processo de defumação a quente melhora as propriedades organolépticas e os níveis de proteína do filé de matrinxã.
Resumo:
This study was carried out with the objective of evaluating the effect of heat (38.8 degreesC) or cold (35.8 degreesC) stress on chicken embryo development and tissues Hsp70 levels, after the 13th day of incubation. Embryo weight (percent egg weight), organ weight (percent embryo weight) and Hsp70 levels (ng Hsp70 mug(-1) total protein) in different tissues (liver, breast muscle, heart, lungs, brain and kidney) were studied at the end of incubation. Cold stress induced a lower embryo weight and lower kidney and lungs weights, whereas heart and liver were lighter in heat-stressed embryos. An interaction between temperature and age was obtained only for Hsp70 levels in kidney and heart. Cold-stressed embryos showed higher Hsp70 levels in the brain, lungs and liver; a decrease in brain and breast muscle Hsp70 levels was seen from the 19th to 20th days in control embryos. Hsp70 levels increased with age in kidneys of control embryos and in heart of heat- and cold-stressed embryos. In conclusion, this study showed that chicken embryo organ weights are affected by incubation temperature, and that Hsp70 expression is tissue dependent (higher levels being seen in the brain) being cold-stress more effective in increasing Hsp70 levels in most studied tissues.
Resumo:
The expression of the MyoD, myogenin, myostatin and Hsp70 genes was estimated in chicken embryos submitted to mild cold (36 +/- 0.5degreesC) or heat (44 +/- 0.5degreesC) for 1 h. 2. Marked decreases in MyoD, myogenin and myostatin transcript levels were observed in embryos exposed to high temperature, contrasting to the higher expression of the Hsp70 mRNA detected in heat-stressed embryos. 3. The exposure of chicken embryos to low temperature significantly affected only the abundance of myogenin mRNA. 4. These findings suggest that myogenic proliferation and differentiation events are compromised by variations in environmental temperature during avian embryogenesis. (C) 2003 Elsevier B.V. Ltd. All rights reserved.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
The relationships among avian uncoupling protein (avUCP) mRNA expression, heat production, and thyroid hormone metabolism were investigated in 7-14-day-old broiler chicks (Gallus gallus) exposed to a low temperature (cold-exposed chicks, CE) or a thermoneutral temperature (TN). After 7 days of exposure, CE chicks exhibited higher heat production (+83%, P < 0.01), avUCP mRNA expression (+20%, P < 0.01), and circulating triiodothyronine (T-3) levels (+104%, P = 0.07) for non-statistically different body weights and feed intake between 3 and 7 days of exposure as compared to TN chicks. Plasma thyroxine (T-4) concentration was clearly decreased in CE chicks (-33%, P = 0.06). The lower hepatic inner-ring deiodination activity (-47%) and the higher renal outer-ring deiodination activity (+75%) measured in CE compared to TN chicks could partly account for their higher plasma T3 concentrations. This study describes for the first time the induction of avUCP mRNA expression by low temperature in chickens, as it has been previously shown in ducklings, and supports the possible involvement of avUCP in avian thermogenesis. (C) 2003 Elsevier B.V. (USA). All rights reserved.
Resumo:
The fuel cell is an emerging cogeneration technology that has been applied successfully in Japan, the USA and some countries in the European Union. This system performs direct conversion of the chemical energy of the oxidation of hydrogen from fuel with atmospheric oxygen into direct current electricity and waste heat via an electrochemical process relying on the use of different electrolytes (phosphoric acid, molten carbonate and solid oxide, depending on operating temperature). This technology permits the recovery of waste heat, available from 200 degreesC up to 1000 degreesC depending on the electrolyte technology, which can be used in the production of steam, hot or cold water, or hot or cold air, depending on the associated recuperation equipment. In this paper, an energy, exergy and economic analysis of a fuel cell cogeneration system (FCCS) is presented. The FCCS is applied in a segment of the tertiary sector to show that it is a feasible alternative for rational decentralized energy production under Brazilian conditions. The technoeconomic analysis shows a global efficiency or fuel utilization efficiency of 86%. Analysis shows that the exergy losses in the fuel cell unit and the absorption refrigeration system are significant. Furthermore, the payback period estimated is about 3 and 5 years for investments in fuel cells of 1000 and 1500 US$/kW, respectively. (C) 2001 Elsevier B.V. Ltd. All rights reserved.
Resumo:
In this paper is proposed the use of biogas generated in the Wastewater Treatment Plant of a Dairy industry. The objective is to apply a thermoeconomic analysis to the supplementary cold water production of an absorption refrigeration system (NH3 + H2O) by the burning of such gas. The exergoeconomic analysis is carried out to allow a comparison between an absorption refrigeration system and of an equivalent compression refrigeration system that uses NH3 as work fluid. The proposed exergoeconomic model uses functional diagrams and allows one to obtain the exergetic incremental functions for each component individually and for the system as a whole. The model minimizes the exergetic manufacturing cost (EMC) which represents the cost of supplementary cold water production at 1degreesC (exergetic base) needed for this dairy's cold storage. As a conclusion, the absorption refrigeration system is better than compression refrigeration system, when the biogas cost is not considered. 2004 Elsevier Ltd. All rights reserved.
Resumo:
Wood gasification technologies to convert the biomass into fuel gas stand out. on the other hand, producing electrical energy from stationary engine is widely spread, and its application in rural communities where the electrical network doesn't exist is very required. The recovery of exhaust gases (engine) is a possibility that makes the system attractive when compared with the same components used to obtain individual heat such as electric power. This paper presents an energetic alternative to adapt a fixed bed gasifier with a compact cogeneration system in order to cover electrical and thermal demands in a rural area and showing an energy solution for small social communities using renewable fuels. Therefore, an energetic and economical analysis from a cogeneration system producing electric energy, hot and cold water, using wooden gas as fuel from a small-sized gasifier was calculated. The energy balance that includes the energy efficiency (electric generation as well as hot and cold water system; performance coefficient and the heat exchanger, among other items), was calculated. Considering the annual interest rates and the amortization periods, the costs of production of electrical energy, hot and cold water were calculated, taking into account the investment, the operation and the maintenance cost of the equipments. Crown Copyright (C) 2010 Published by Elsevier Ltd. All rights reserved.
Resumo:
defect metal alloy strip when thixorolling directly from the semi-solid state. To facilitate the study lead/tin alloys were chosen for their relatively low operating temperature. The objective is to extrapolate these findings to the higher temperature aluminium, alloys. Three alloys (70%Pb30%Sn, 60%Pb-40%Sn, 50%Pb-50%wtSn) were used particularly to study the influence of the solidification interval. The equipment consists of a two roll mill arranged as an upper and lower roller, where both rollers are driven at a controlled speed. The lower roller is fed with semi solid alloy through a ceramic nozzle attached to the lower end of a cooling slope. Several types of nozzle and their position at the roller were tested. This produced different solidifications and consequently different finished strip. The alloys were first cast and then poured onto the cooling slope through a tundish in order to create a continuous laminar flow of slurry and uniformity of metal strip quality. The pouring was tested at different positions along the slope. The cooling slope was coated with colloidal graphite to promote a smooth slurry flow and avoid the problem of adherence and premature solidification. The metallic slurry not only cools along the slope but is also initially super-cooled to a mush by the lower roller whilst at room temperatures, thus enabling thixorolling. It was also found that the nozzle position could be adjusted to enable the upper roller to also contribute to the solidification of the metallic slurry. However the rollers and the cooling slope naturally heat up. Temperature distribution in these zones was analysed by means of three thermocouples positioned along the cooling slope and a fourth in the base of the semi solid pool within the nozzle. The objective being to design an optimum pouring and cooling system. The formed strip was cooled down to room temperature with a shower of water. Microstructures of the thixorolling process were analysed. The differences in solidification conditions resulted in differing qualities of finished strip and corresponding defect types, all of which are a serious quality issue for the rolled product.
Resumo:
In this paper a non-isothermal two-phase model for oil-R134a refrigerant mixture flow is presented to predict the R134a leakage through the radial clearance of rolling piston compressors. The flow is divided in a liquid single-phase region and in a two-phase region, in which the homogeneous model is used to simulate the flow. The refrigerant leakage is determined using the mixture mass flow rate and the refrigerant mass fraction variation along the flow. The results are obtained for inlet pressures varying from 200 to 700 kPa, inlet temperatures ranging from 40 to 60 degrees C, and minimal clearances between 10 and 60 mu m. The results are firstly compared to existing isothermal model data, showing that there is a significant difference between the leakage flow rates predicted by isothermal and non-isothermal models. Finally, a useful general equation for compressor designers is proposed to calculate the refrigerant leakage for a large range of operation conditions. (C) 2012 Elsevier Ltd and IIR. All rights reserved.