907 resultados para coefficient of nutrient utilization


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Chromium electrodeposition is a technique for the production of functional coatings on engineering components. These coatings are extensively micro-cracked and present high level of hardness, resistance to corrosion and wear and low coefficient of friction. In this paper the shot peening influence on the fatigue strength of aluminum 7050-T7451 alloy chromium electroplated, was investigated.The shot peening process was carried out to create residual stresses using ceramic and glass shots. A hard chromium electroplated coating of 100 mu m thickness was performed on the base material and the shot peened base material surfaces. S-N curves were obtained in axial and bending fatigue tests and compared with the 7050-T7451 aluminum alloy. In order to study the influence of residual stresses on fatigue life, the behavior of compressive residual stress field was measured by an X-ray tensometry.An increase in the axial fatigue strength of 25% and 50% of ceramic and glass shots, respectively, was observed. The lower performance in fatigue life for ceramic-shot peening may be attributed to higher surface damage, as a consequence of the overpeening intensity performed. However, in bending fatigue the behavior was practically equivalent for both processes. Fracture surface analysis by scanning electron microscopy was used to observe crack origin sites from shot peened and chromium electroplated samples. (C) 2006 Elsevier Ltd. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The effect of film orientation on piezoelectric and ferroelectric properties of bismuth layered compounds deposited on platinum coated silicon substrates was investigated. Piezo-force microscopy was used to probe the local piezoelectric properties of Bi(4)Ti(3)O(12), CaBi(4)Ti(4)O(15) and SrBi(4)Ti(4)O(15) films. Our measurements on individual grains clearly reveal that the local piezoelectric properties are determined by the polarization state of the grain. A piezoelectric coefficient of 65 pm/V was attained after poling in a grain with a polar axis very close to the normal direction. The piezoelectric coefficient and the remanent polarization were larger for a-b axes oriented than for c-axis-oriented films. (c) 2007 Elsevier B.V All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The purpose of this study was to evaluate the setting time and the thermal expansion coefficient of 2 endodontic cements, MTA-Angelus and a novel cement called CER. The setting time was determined in accordance to ANSI/ADA specifications no. 57. Three samples of 10 mm diameter and 2 mm thickness were prepared for each cement. The thermal expansion measurements were performed by strain gauge technique. Four samples of each cement were prepared using silicone rings of 5 mm diameter and 2 mm thickness. The data were analyzed statistically using the Student t test. The setting time obtained for the MTA-Angelus and CER cements was 15 (SD 1) min and 7 (SD 1) min, respectively. The linear coefficient of thermal expansion was 8.86 (SD 0.28) mu strain/degrees C for MTA-Angelus and 11.76 (SD 1.20) mu strain/degrees C for CER. The statistical analysis showed significant difference (P < .05) in the setting time and linear coefficient of thermal expansion between the 2 cements. The CER cement has a coefficient of expansion similar to dentin, which could contribute to a decrease of microleakage degree.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This work presents a methodology for iron determination in fuel ethanol using a modified carbon paste electrode with 1.10 fenantroline/nafion. The electrochemical parameters were optimized for the proposed system and the voltammetric technique of square wave was employed for iron determination. An accumulation time of 5 minutes, such as a 100 mV of pulse magnitude (E(sw)) and frequency (f) of 25 Hz were used as optimized experimental conditions. The modified carbon paste electrode presented linear dependence of amperometric signal with iron concentration in a work range from 6.0x10(-6) until 2.0x10(-5) mol L(-1) of iron, exhibiting a linear correlation coefficient of 0.9884, a detection limit of 2.4 x10(-6) mol L(-1) (n = 3) and amperometric sensibility of 4.5x10(5) mu A/mol L(-1). Analytical curve method was used for iron determination at a commercial fuel sample. Flame atomic absorption spectroscopy was employed as comparative technique.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJETIVO: Testar os efeitos do extrato aquoso de Coleus barbatus (EAB) na cirrose biliar secundária por obstrução das vias biliares extra-hepáticas em ratos jovens. MÉTODOS: Quarenta ratos Wistar machos com 21 dias de vida (P21), foram distribuídos em quatro grupos de 10 animais, submetidos a operação simulada ou dupla ligadura e ressecção do ducto biliar (S ou L) combinados EAB e a Água (B ou A). No P48, foi medido o tempo de sono com o pentobarbital (TS). No P49, foram submetidos a eutanásia para a determinação das atividades séricas do aspartato aminotransferase (AST) e da alanina aminotransferases (ALT); após a eutanásia foram avaliados o peso fresco do fígado (PFF) e, em cortes histológicos do fígado, a freqüência de mitoses (FM), o número de áreas de necrose (NN), a intensidade da fibrose (IF) e da proliferação ductal (IPD). Os efeitos da colestase, os do EAB e suas interações foram testados pela ANOVA com dois fatores, e as comparações múltiplas pareadas foram realizadas pelo teste de S.N.K ou teste de Wilcoxon. Também foi determinada a correlação linear de Pearson entre as variáveis histológicas duas a duas separadamente para os grupos LA e LD. O nível de significância estatística para os vários testes foi de p do erro alfa <0,05. RESULTADOS: A colestase aumentou significativamente o TS, a ALT, a AST, o PFF, a MI, o NN, a IF e a IPD. O EAB diminuiu o TS e a IM nos animais sem colestase (operação simulada). O EAB diminuiu o TS, a ALT, a AST, o PFF, a MI, o NN e IF na colestase. No grupo LA houve correlação positiva entre a IPD e a IF, correlação negativa entre a IPD e a FM e correlação negativa entre a IF a FM. No grupo LD houve correlação negativa entre o NN e a IPD. CONCLUSÕES: Na ausência de colestase o EAB encurta o tempo de sono e diminui a freqüência de mitoses. O EAB apresenta efeito hepatoprotetor no modelo de cirrose biliar secundária a obstrução biliar extra-hepática.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This paper presents a simple, fast and sensitive method to determine chromic oxide (used as a biological marker of fish feed) in samples of fish feces by GFAAS through the direct introduction of slurries of the samples into the spectrometer's graphite tube. The standard samples of feces and of fish feed containing 0.10-1.00 mg kg(-1) of Cr2O3 were pre-frozen for I min in liquid nitrogen and then ground a cryogenic mill for 2 min, which reduced the samples' grain size to less than 60 mu m. The standard slurries were prepared by mixing 20 mg of standard samples of fish feed or feces with I mL of a solution containing 0.05% (v/v) of Triton X-100 and 0.50% (v/v) of suprapure HNO3 directly in the spectrometer's automatic sampling glass. The final concentrations of Cr2O3 present in the standard slurries were 2, 4, 8, 16 and 20 mu g L-1. After sonicating the mixture for 20s, 10 mu L of standard slurries were injected into the graphite tube, whose internal wall was lined with a metallic palladium film that acted as a permanent chemical modifier. The limits of detection (LOD) and quantification (LOQ) calculated for 20 readings of the blank of the standard slurries (2%, m/v of feces or feed devoid of minerals) were 0.81 and 2.70 mu g L-1 of Cr2O3 for the standard feces slurries, 0.84 and 2.83 mu g L-1 of Cr2O3 for the standard feed slurries. The proposed method was applied in studies of nutrient digestibility of different fish feeds and its results proved compatible with the results obtained from samples pre-mineralized by acid digestion. (c) 2005 Elsevier B.V. All rights reserved.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

An experiment was conducted to study ileal digestibility of nutrients and to verify the ability of broilers to select feed in order to meet their requirements for protein and energy. The treatments consisted of six diets: R+S: free-choice feeding with rice bran (energy) and soybean meal (protein); C+G: free-choice feeding with corn (energy) and corn gluten meal (protein); R+G: free-choice feeding with rice bran (energy) and corn gluten meal (protein); C+S: free-choice feeding with corn (energy) and soybean meal (protein); R+C+G+S: free-choice feeding with rice bran and corn (energy) and corn gluten meal and soybean meal (protein); and BD: basal diet represented by a complete diet composed of 63% corn and 33% soybean meal. The results indicated that the adjustment to nutritional requirements does not depend only on the ability of birds to select feed. It might also depend on intake and ingredient quality, since some ingredients did not provide a balanced amount of nutrients. The birds were able to fulfill their requirements for maintenance, that is, they consumed the minimum amount of amino acids (g per day) for maximum growth. The free-choice group with corn gluten meal as the protein source had the worst performance, which indicated that this feed is not recommended as a primary source of amino acids for broilers. The C+G diet presented the highest digestibility coefficient of dry matter and crude protein, whereas the C+S diet resulted in the highest digestibility coefficient of ether extract and nitrogen-free extract, indicating that diet digestibility was affected by the type of feed used as energy and protein sources. In general, the high digestibility values indicate that broilers are able to efficiently digest and absorb the supplied feed.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Em dois ensaios simultâneos avaliou-se níveis de energia metabolizável (EM) e de lisina digestível (LIS) para suínos de linhagem específica, na fase de crescimento, criados em condições de isolamento sanitário. Foram utilizados 72 machos castrados com 23,34 ± 1,62 kg e 72 marrãs com 21,56 ± 2,86 kg. O delineamento experimental foi em blocos casualizados, em esquema fatorial 2 x 3, com seis repetições e dois animais por unidade experimental. Os tratamentos decorreram da combinação dos fatores em (3.270 e 3.500 kcal/kg de ração) e LIS (0,83; 1,03 e 1,23%). Não houve interação dos fatores, mas foram constatados efeitos principais de em e LIS sobre as variáveis de desempenho. Os machos castrados apresentaram respostas diferenciadas aos níveis crescentes de lisina dietética, com aumento linear no ganho em peso, enquanto no consumo de ração e na conversão alimentar ocorreu respostas quadráticas. As marrãs apresentaram redução linear na conversão alimentar em resposta à elevação da concentração de lisina na dieta. Criados com separação de sexo e em condições desejáveis de saúde, na fase de crescimento, suínos machos castrados e marrãs da linhagem genética estudada, responderam eficientemente ao acréscimo de lisina digestível nas dietas. Os benefícios dietéticos da lisina no desempenho dos machos castrados não dependeram dos níveis estudados de energia. Nas marrãs, a melhor conversão alimentar foi obtida com dietas de 3.500 kcal EM, caracterizando a maior eficiência na utilização dos nutrientes para as necessidades de desempenho, em comparação aos machos castrados.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The effect of the utilization of three semen protocols (Inra 82®, Merck Gema and Botu-crio®) and two filling techniques (0.25 and 0.50 mL straws) in Mangalarga Marchador stallions were studied in this experiment. Sperm parameters were assessed during processing and post-freezing. No interactions between the protocols and type of filling were observed, so they were assessed separately. Sperm parameters were not altered when the extender was added to the centrifugation; however, there was reduction of motility and strength when freezing extenders were added. The Botu-crio® protocol preserved the parameters of total and progressive sperm motility, smoothed path velocity (µm/s), straight line velocity (µm/s), track velocity (µm/s) and the average and fast spermatozoa percentage better than the others. No difference between the extenders for the percentage of sperm integrity was observed. There was no difference in the responses studied on the filling techniques. The stallions presented better freezing with the use of the Botu-crio® protocol. The best post-freezing viability results were found for semen frozen using the Botu-crio® protocol and there were no differences concerning the sperm quality comparing 0.25 and 0.50 mL straws.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)