854 resultados para automated tractor vehicle
Resumo:
In this paper, a methodology based on Unconstrained Binary Programming (UBP) model and Genetic Algorithms (GAs) is proposed for estimating fault sections in automated distribution substations. The UBP model, established by using the parsimonious set covering theory, looks for the match between the relays' protective alarms informed by the SCADA system and their expected states. The GA is developed to minimize the UBP model and estimate the fault sections in a swift and reliable manner. The proposed methodology is tested by utilizing a real-life automated distribution substation. Control parameters of the GA are tuned to achieve maximum computational efficiency and reduction of processing time. Results show the potential and efficiency of the methodology for estimating fault section in real-time at Distribution Control Centers. ©2009 IEEE.
Resumo:
Nowadays, drives that use a combination of induction motors and frequency inverters are very common, a fact due to the financial practicality and viability in purchasing and operating that system. This system modeling and simulation becomes important when it wants to evaluate the performance, to calculate and correct parameters, and it has a fundamental role in functionality and viability analysis for application of new configurations and technologies. This work is about to elaborate a simple induction motor model based in the torque versus speed characteristic, using the linearization method for application in a specific operation range to be controlled by a frequency inverter. © 2011 Springer-Verlag Berlin Heidelberg.
Resumo:
The purpose of this study was to develop a mucoadhesive stimuli-sensitive drug delivery system for nasal administration of zidovudine (AZT). The system was prepared by formulating a low viscosity precursor of a liquid crystal phase, taking advantage of its lyotropic phase behavior. Flow rheology measurements showed that the formulation composed of PPG-5-CETETH-20, oleic acid and water (55, 30, 15% w/w), denominated P, has Newtonian flow behavior. Polarized light microscopy (PLM) revealed that formulation P is isotropic, whereas its 1:1 (w/w) dilution with artificial nasal mucus (ANM) changed the system to an anisotropic lamellar phase (PD). Oscillatory frequency sweep analysis showed that PD has a high storage modulus (G′) at nasal temperatures. Measurement of the mucoadhesive force against excised porcine nasal mucosa or a mucin disk proved that the transition to the lamellar phase tripled the work of mucoadhesion. Ex vivo permeation studies across porcine nasal mucosa exhibited an 18-fold rise in the permeability of AZT from the formulation. The Weibull mathematical model suggested that the AZT is released by Fickian diffusion mechanisms. Hence, the physicochemical characterization, combined with ex vivo studies, revealed that the PPG-5-CETETH-20, oleic acid, and water formulation could form a mucoadhesive matrix in contact with nasal mucus that promoted nasal absorption of the AZT. For an in vivo assessment, the plasma concentrations of AZT in rats were determined by HPLC method following intravenous and intranasal administration of AZT-loaded P formulation (PA) and AZT solution, respectively, at a dose of 8 mg/kg. The intranasal administration of PA resulted in a fast absorption process (Tmax = 6.7 min). Therefore, a liquid crystal precursor formulation administered by the nasal route might represent a promising novel tool for the systemic delivery of AZT and other antiretroviral drugs. In the present study, the uptake of AZT absorption in the nasal mucosa was demonstrated, providing new foundations for clinical trials in patients with AIDS. © 2012 Elsevier B.V. All rights reserved.
Resumo:
The paper presents and evaluates three methods for automatically estimating the main orientation of Martian dust devil tracks in MOC and HiRISE images. Inferring such information about dust devils from their tracks is important to better understand the near surface wind. The methods considered were based on gradient direction, directional openings and morphological granulometry. The accuracy of the methods was asserted by comparing the results to a set of directions estimated visually and assumed to be the ground truth. The higher accuracy was reached using directional openings. Besides, the directions inferred by this method were compared to those predicted by the GCM and the results agreed. © 2013 COSPAR.
Resumo:
Intestinal parasitosis constitutes a serious health problem in most tropical countries. The diagnosis of enteroparasites in laboratory routine relies on the examination of stool samples using optical microscopy and the error rates usually range from moderate to high. Approaches based on automatic image analysis have been proposed, but the methods are usually specific for some species, some of them are computationally expensive, and image acquisition and focus are manual. We present a solution to automate the diagnosis of the 15 most common species of enteroparasites in Brazil, using a sensitive parasitological technique, a motorized microscope with digital camera for automatic image acquisition and focus, and fast image analysis methods. The results indicate that our solution is effective and suitable for laboratory routine, in which the exam must be concluded in a few minutes. © 2013 IEEE.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Includes bibliography
Study of problems related with the establishment of motor-vehicle industries in developing countries
Resumo:
Information Paper, No 12
Resumo:
Information Paper, No 15
Resumo:
Information Paper, No 19
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
The tire inflation pressure, among other factors, determines the efficiency in which a tractor can exert traction. It was studied the effect of using two tire inflation pressures, 110.4 kPa in the front and rear wheels, 124.2 kPa in the front wheel and 138 kPa in the rear wheels, the energetic efficiency of an agricultural tractor of 147 kW of engine power, in the displacement speed of 6.0 km.h-1, on track with firm surface, with the tractor engine speed of 2000 rpm. For each condition of the tire pressure, the tested tractor was subjected to constant forces in the drawbar of 45 kN and 50 kN, covering 30 meters. It was used a randomized complete block with a 2x2 factorial arrangement (tire pressure and drawbar power) with four replications, totaling 16 experimental units. Data were subjected to analysis of variance, using the Tukey test at 5% probability for comparison averages. The lowest hourly and specific fuel consumption, the lowest slippage of the wheelsets and the highest efficiency in the drawbar was obtained with the tire inflation pressure of 110.4 kPa in the front and rear tires of the tractor, highlighting that lower pressures improve energetic and operational performance of the tractor.
Resumo:
Cryopreservation of sperm is important to preserve the gerrnplasm from animals of genetic value, which can die unexpectedly. This study compares conventional and automated methods of cryopreservation of spermatozoa obtained from the epididymis of bulls post-mortem. Twenty-two epididymides were obtained from a commercial slaughterhouse. Spermatozoa were collected from the tail of the epididymis using the retrograde flow technique. Thus, the samples, which were diluted in 10 ml of extender without glycerol (Botubov (R) I, Botupharma, Botucatu, SP, Brazil), were evaluated on motility, sperm vigor, structural and functional (swelling hypoosmotic test) membrane integrity, mitochondrial activity, sperm viability and ADN fragmentation. The samples were divided into two aliquots and diluted in extender with glycerol (Botubov (R) II, Botupharma, Botucatu, SP, Brazil) at a concentration of 50x10(6) motile sperm/0.5 French straws. One sample was frozen by the conventional method (4 hours at 5 degrees C, in a refrigerator and 20 min in nitrogen vapor) and the other by the automated method (Cryogen (R) Dualflex, Neovet, Uberaba, MG, Brazil). The parameters were higher in all the tests of fresh sperm samples, with the exception of the swelling hypoosmotic test, which showed no significant difference when the results were compared with sperm frozen by the conventional method. The average motility of fresh spermatozoa was 74%, and conventional and automated averages were 29 and 25%, respectively. Therefore, although cryopreservation techniques reduce sperm quality parameters, the viability of the sperm is maintained, and these methods can be used to preserve sperm.