913 resultados para all-solid-state


Relevância:

90.00% 90.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

90.00% 90.00%

Publicador:

Resumo:

This Final Paper had as it main goal to make a thermoanalytical study of lighter trivalent lanthanides (Lanthanum, Cerium, Praseodymium, Neodymium, Samarium and Europium) with the Ibuprofen ligand (nonsteroidal anti-inflammatory) that have a general formula LnL3.nH2O, on solid state, where Ln are the Lanthanides, L is the Ibuprofen ligand and n = number of water molecules of hydration that went from 1,0 to all the compounds. In order to characterize this compounds, it has been used the thermoanalytical techniques TG-DTA (thermogravimetry - Diferential Thermal Analysis) and DSC (Diferential Scanning Calorimetry), Fourier transformed infrared spectroscopy (FTIR) and complexometric titration with EDTA. Through the TG-DTA technique, it has been possible to set the thermal stability of the compounds, the number of thermal decomposition steps and temperatures that ocurred that also provided stoichiometry to the synthesized compounds. The DSC technique has shown the enthalpy of dehydration of the samarium and europium compounds, it was not possible to see it in the other compounds due to a endothermic peak on the DSC curve not being formed. In the case of neodymium, a thermal event ocurred, in which it could be a oxidative decarboxylation right after the dehydration. The infrared was utilised to study the carboxilate groups streches, and so, suggest a ligand metals compound coordination, that to this present paper has been a bidentade bridged coordenation. At last, the complexometric tritation was used to very the ammount of metal present in each compound, and so, verify if the proposed stoichiometry was according to the theory

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Nuclear medicine is a medical specialty related to imagery that deals with imaging techniques, diagnosis and therapy, allowing observing the physiological state of tissues noninvasively by marking the molecules participating of these physiological processes with radioactive isotopes, thus creating the called radionuclides. The image of a radionuclide is one of the most important applications of radioactivity in nuclear medicine. The equipment’s of nuclear medicine imaging use the principle of radiation detection, turning it into an electrical signal which, through specific algorithms, allows forming tomographic images that provide information about the functional status of organs. New detection systems have been developed for tomographic acquisitions using solid state detectors. These devices use crystals of cadmium zinc telluride (CdZnTe). Some of the advantages of this detector are a significant improvement of signal to noise ratio, the increased spectral and spatial resolution, which in sum, result in greater clarity of the images obtained, opening new perspectives for imaging protocols previously unattainable. In contrast, all other gamma-cameras equipped with vacuum tubes have remained relatively unchanged for nearly fifty years. In these gamma-cameras, the images are obtained using two steps significantly less efficient: the gamma rays are converted to light through a first device, and then the light is converted into an electrical signal through a second device. One of functions the Medical Physicist is related to the quality control of equipment. This control ensures that the information and images provided are true and thus credible to be used in medical reports. To perform this type of analysis the physicist must understand the performance characteristics and operation of all equipment of the department concerned; besides, in the absence of specific legislation, proposing...(Complete abstract click electronic access below)

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

90.00% 90.00%

Publicador:

Resumo:

Pós-graduação em Ciência dos Materiais - FEIS

Relevância:

90.00% 90.00%

Publicador:

Resumo:

The hydrolysis of pyridoxalrhodanine in a basic medium containing the dimethylthallium(III) cation afforded the compound [TlMe2(L)]center dot H2O (1.H2O) [HL = 5-(hydroxymethyl)-8-methyl-3-thiol-7-azacoumarin]. This compound was characterized in solid state by IR spectroscopy and in solution by H-1 and C-13{H-1} NMR spectrometry. X-ray diffraction showed that the crystal consists of associated TlMe2(L) units and hydrogen bonded water molecules. The L- anion is bound to the metal mainly by a bridging S atom [Tl-S = 2.9458(18) angstrom; 2.9616(16) angstrom], although secondary interactions through O atoms (Tl-O: 2.861(5); 2.900(5) angstrom)] are also present. The longer Tl-O interaction and the hydrogen bonds of the water molecules give rise to a tridimensional polymeric structure. (C) 2012 Elsevier B.V. All rights reserved.

Relevância:

90.00% 90.00%

Publicador:

Resumo:

This paper describes a long-range remotely controlled CE system built on an all-terrain vehicle. A four-stroke engine and a set of 12-V batteries were used to provide power to a series of subsystems that include drivers, communication, computers, and a capillary electrophoresis module. This dedicated instrument allows air sampling using a polypropylene porous tube, coupled to a flow system that transports the sample to the inlet of a fused-silica capillary. A hybrid approach was used for the construction of the analytical subsystem combining a conventional fused-silica capillary (used for separation) and a laser machined microfluidic block, made of PMMA. A solid-state cooling approach was also integrated in the CE module to enable controlling the temperature and therefore increasing the useful range of the robot. Although ultimately intended for detection of chemical warfare agents, the proposed system was used to analyze a series of volatile organic acids. As such, the system allowed the separation and detection of formic, acetic, and propionic acids with signal-to-noise ratios of 414, 150, and 115, respectively, after sampling by only 30 s and performing an electrokinetic injection during 2.0 s at 1.0 kV.