943 resultados para X-Rays.


Relevância:

60.00% 60.00%

Publicador:

Resumo:

The present study gives a contribution to the knowledge on the Na-feldspar and plagioclases, extending the database of the Raman spectra of plagioclases with different chemical compositions and structural orders. This information may be used for the future planetary explorations by “rovers”, for the investigation of ceramics nanocrystal materials and for the mineralogical phase identification in sediments. Na-feldspar and plagioclase solid solution have been investigated by Raman spectroscopy in order to determine the relationships between the vibrational changes and the plagioclase crystal chemistry and structure. We focused on the Raman micro-spectroscopy technique, being a non-destructive method, suited for contactless analysis with high spatial resolution. Chemical and structural analyses have been performed on natural samples to test the usefulness of Raman spectroscopy as a tool in the study of the pressure-induced structural deformations, the disordering processes due to change in the Al-Si distribution in the tetrahedral sites and, finally, in the determination of the anorthitic content (Anx) in plagioclase minerals. All the predicted 39 Ag Raman active modes have been identified and assigned to specific patterns of atomic vibrational motion. A detailed comparison between experimental and computed Raman spectra has been performed and previous assignments have been revised, solving some discrepancies reported in recent literature. The ab initio calculation at the hybrid HF/DFT level with the WC1LYP Hamiltonian has proven to give excellent agreement between calculated and experimentally measured Raman wavenumbers and intensities in triclinic minerals. A short digression on the 36 infrared active modes of Na-feldspar has been done too. The identification of all 39 computed Raman modes in the experimentally measured spectra of the fully ordered Na-feldspar, known as low albite, along with the detailed description of each vibrational mode, has been essential to extend the comparative analysis to the high pressure and high temperature structural forms of albite, which reflect the physical–chemical conditions of the hosting rocks. The understanding of feldspar structure response to pressure and temperature is crucial in order to constrain crustal behaviour. The compressional behaviour of the Na-feldspar has been investigated for the first time by Raman spectroscopy. The absence of phase transitions and the occurrence of two secondary compression mechanisms acting at different pressures have been confirmed. Moreover, Raman data suggest that the internal structural changes are confined to a small pressure interval, localized around 6 GPa, not spread out from 4 to 8 GPa as suggested by previous X-rays studies on elasticity. The dominant compression mechanisms act via tetrahedral tilting, while the T-O bond lengths remain nearly constant at moderate compressional regimes. At the spectroscopic level, this leads to the strong pressure dependencies of T-O-T bending modes, as found for the four modes at 478, 508, 578 and 815 cm-1. The Al-Si distribution in the tetrahedral sites affects also the Raman spectrum of Na-feldspar. In particular, peak broadening is more sensitive than peak position to changes in the degree of order. Raman spectroscopy is found to be a good probe for local ordering, in particular being sensitive to the first annealing steps, when the macroscopic order parameter is still high. Even though Raman data are scattered and there are outliers in the estimated values of the degree of order, the average peak linewidths of the Na-feldspar characteristic doublet band, labelled here as υa and υb, as a function of the order parameter Qod show interesting trends: both peak linewidths linearly increase until saturation. From Qod values lower than 0.6, peak broadening is no more affected by the Al-Si distribution. Moreover, the disordering process is found to be heterogeneous. SC-XRD and Raman data have suggested an inter-crystalline inhomogeneity of the samples, i.e., the presence of regions with different defect density on the micrometric scale. Finally, the influence of Ca-Na substitution in the plagioclase Raman spectra has been investigated. Raman spectra have been collected on a series of well characterized natural, low structural plagioclases. The variations of the Raman modes as a function of the chemical composition and the structural order have been determined. The number of the observed Raman bands at each composition gives information about the unit-cell symmetry: moving away from the C1 structures, the number of the Raman bands enhances, as the number of formula units in the unit cell increases. The modification from an “albite-like” Raman spectrum to a more “anorthite-like” spectrum occurs from sample An78 onwards, which coincides with the appearance of c reflections in the diffraction patterns of the samples. The evolution of the Raman bands υa and υb displays two changes in slope at ~An45 and ~An75: the first one occurs between e2 and e1 plagioclases, the latter separates e1 and I1 plagioclases with only b reflections in their diffraction patterns from I1 and P1 samples having b and c reflections too. The first variation represents exactly the e2→e1 phase transitions, whereas the second one corresponds in good approximation to the C1→I1 transition, which has been determined at ~An70 by previous works. The I1→P1 phase transition in the anorthite-rich side of the solid solution is not highlighted in the collected Raman spectra. Variations in peak broadening provide insights into the behaviour of the order parameter on a local scale, suggesting an increase in the structural disorder within the solid solution, as the structures have to incorporate more Al atoms to balance the change from monovalent to divalent cations. All the information acquired on these natural plagioclases has been used to produce a protocol able to give a preliminary estimation of the chemical composition of an unknown plagioclase from its Raman spectrum. Two calibration curves, one for albite-rich plagioclases and the other one for the anorthite-rich plagioclases, have been proposed by relating the peak linewidth of the most intense Raman band υa and the An content. It has been pointed out that the dependence of the composition from the linewidth can be obtained only for low structural plagioclases with a degree of order not far away from the references. The proposed tool has been tested on three mineralogical samples, two of meteoric origin and one of volcanic origin. Chemical compositions by Raman spectroscopy compare well, within an error of about 10%, with those obtained by elemental techniques. Further analyses on plagioclases with unknown composition will be necessary to validate the suggested method and introduce it as routine tool for the determination of the chemical composition from Raman data in planetary missions.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

O objetivo deste estudo foi avaliar o tamanho do espaço aéreo naso e bucofaríngeo em indivíduos com má oclusão Classe II, divisão 1 de Angle. A metodologia constou da mensuração do espaço aéreo naso e bucofaríngeo em 122 telerradiografias laterais de indivíduos na faixa etária dos 12 aos 21 anos, brasileiros leucodermas. Desses indivíduos, 62 apresentavam respiração nasal e 60 respiração bucal, não sendo submetidos a tratamento ortodôntico prévio. Os resultados demonstraram a ausência de dimorfimo sexual; os indivíduos respiradores nasais apresentaram maiores dimensões dos limites superior e inferior e da menor secção transversal do espaço aéreo quando comparado aos respiradores bucais. O tamanho médio da adenóide foi maior nos pacientes respiradores bucais. Quando comparamos as variáveis estudadas com os padrões faciais não foram observadas diferenças entre os mesmos, porém quando associamos padrão facial com o tipo de respiração foi encontrada maior proporção de indivíduos respiradores bucais nos padrões dolicofacial e mesofacial em relação ao padrão braquifacial.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Esta pesquisa objetivou estudar retrospectivamente por meio de radiografias em norma frontal e modelos de gesso as alterações dentoesqueléticas de pacientes com má oclusão de Classe II, 1ª divisão, divididos em dois grupos: Grupo Tratado, constituído de 28 pacientes, sendo 13 pacientes do sexo masculino e 15 do sexo feminino, tratados com aparelho regulador de função de Fränkel - 2 (RF-2), por um período ativo de 1,5 anos; Grupo Controle: constituído de 28 pacientes, sendo 12 do sexo masculino e 16 do sexo feminino, sem nenhum tipo de tratamento durante o acompanhamento longitudinal de 1,5 anos. A amostra deste estudo consistiu de 112 telerradiografias em norma frontal e 112 pares de modelos de gesso, 56 obtidos ao início (T1) e 56 ao final da observação (T2). Após a análise estatística das mensurações obtidas, concluiu- se que houve como resultado alterações estatisticamente significantes em todas as medidas analisadas e o aparelho RF-2 teve atuação direta nas variáveis: distância intermolares superio res e inferiores (radiografias e modelos),profundidade palatina, largura maxilar e altura facial ântero-inferior.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

O propósito deste estudo foi avaliar a concordância entre a Análise facial subjetiva, proposta por CAPELOZZA FILHO e a Análise Cefalométrica de Tecidos Moles, de ARNETT; McLAUGHLIN. Fotografias de frente e de perfil e telerradiografias em norma lateral padronizadas, de 50 indivíduos, com média de idade de 24 anos e 1 mês foram utilizadas para a avaliação. Verificou-se também nos indivíduos classificados como Padrão I, a correspondência dos valores médios e dos desvios-padrão das medidas obtidas, com os valores normativos da Análise Cefalométrica dos Tecidos Moles para os indivíd uos com harmonia facial. Constatou-se em indivíduos do Padrão I que os lábios sempre se encontram à frente da Linha Vertical Verdadeira, e que apesar de grandes variações do ponto pogônio, ainda é mantido o equilíbrio facial. Os resultados demonstraram que a Análise facial subjetiva eficiente na classificação do padrão facial.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

O propósito neste estudo foi determinar a posição de repouso da língua em indivíduos com oclusão dentária normal e respiração nasal, por meio de telerradiografias em norma lateral realizadas após a ingestão de bário. A amostra foi composta por 66 radiografias de indivíduos brancos com oclusão dentária normal, sendo 26 do sexo masculino e 40 do sexo feminino, na faixa etária de 12 a 21 anos de idade, procedentes de escolas da região do Grande ABC Paulista. O critério utilizado para diagnóstico da oclusão normal foi As Seis Chaves para a Oclusão Normal preconizadas por Andrews (1972), devendo estar presentes no mínimo quatro das seis chaves, sendo obrigatória a presença da primeira chave de oclusão que é a da relação interarcos. As radiografias foram obtidas com o indivíduo em posição natural da cabeça após a ingestão de contraste de sulfato de bário para evidenciar o controle da língua. Posteriormente foi feito o desenho anatômico das estruturas pesquisadas, marcados os pontos cefalométricos, traçadas as linhas e os planos, e por último obtidas as seguintes medidas lineares: comprimento e altura da língua, distância do dorso da língua na sua porção média até o palato duro e a distância entre a ponta da língua e a incisal do incisivo inferior. Por meio dos resultados encontrados verificou-se que não existe um padrão único de posicionamento de repouso da língua dentro da cavidade oral, em pacientes respiradores nasais, variando muito sua distância até a incisal dos incisivos inferiores, bem como até o palato duro, havendo uniformidade apenas no fato da língua tocar o palato mole em todos os indivíduos da amostra. Não houve relação estatisticamente significante entre a posição de repouso da língua e os biotipos faciais e nem dimorfismo sexual.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Este estudo avaliou o posicionamento ântero posterior dos primeiros molares inferiores, durante o tratamento ortodôntico, utilizando o arco lingual inferior como acessório de ancoragem na técnica Straight-Wire, em comparação aos casos tratados pela técnica Edgewise, sem a utilização do arco lingual. Dois grupos foram selecionados, ambos apresentando má oclusão de Classe I de Angle7, tratados com extração dos primeiros pré-molares superiores e inferiores. Foi utilizada uma amostra de 255 telerradiografias em norma lateral, obtidas de pacientes brasileiros, de ambos os sexos, com média de idade de 13 anos e 6 meses e com diferentes padrões de crescimento facial. Embasado na análise e discussão dos resultados, concluiu-se que: 1) do início do tratamento ao fim da fase de nivelamento, a perda de ancoragem coronária do primeiro molar inferior foi maior nos casos tratados com a técnica Straight-Wire; 2) do fim da fase de nivelamento ao fim do tratamento, a perda de ancoragem coronária e radicular do primeiro molar inferior foi maior na técnica Edgewise; 3) do início ao fim tratamento a perda de ancoragem radicular foi maior nos pacientes tratados com a técnica Edgewise; e 4) o deslocamento ântero-posterior dos incisivos inferiores não apresentou diferença estatisticamente significante para ambas as técnicas, em todas as etapas observadas.(AU)

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This work concerns the developnent of a proton irduced X-ray emission (PIXE) analysis system and a multi-sample scattering chamber facility. The characteristics of the beam pulsing system and its counting rate capabilities were evaluated by observing the ion-induced X-ray emission from pure thick copper targets, with and without beam pulsing operation. The characteristic X-rays were detected with a high resolution Si(Li) detector coupled to a rrulti-channel analyser. The removal of the pile-up continuum by the use of the on-demand beam pulsing is clearly demonstrated in this work. This new on-demand pu1sirg system with its counting rate capability of 25, 18 and 10 kPPS corresponding to 2, 4 am 8 usec main amplifier time constant respectively enables thick targets to be analysed more readily. Reproducibility tests of the on-demard beam pulsing system operation were checked by repeated measurements of the system throughput curves, with and without beam pulsing. The reproducibility of the analysis performed using this system was also checked by repeated measurements of the intensity ratios from a number of standard binary alloys during the experimental work. A computer programme has been developed to evaluate the calculations of the X-ray yields from thick targets bornbarded by protons, taking into account the secondary X-ray yield production due to characteristic X-ray fluorescence from an element energetically higher than the absorption edge energy of the other element present in the target. This effect was studied on metallic binary alloys such as Fe/Ni and Cr/Fe. The quantitative analysis of Fe/Ni and Cr/Fe alloy samples to determine their elemental composition taking into account the enhancement has been demonstrated in this work. Furthermore, the usefulness of the Rutherford backscattering (R.B.S.) technique to obtain the depth profiles of the elements in the upper micron of the sample is discussed.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Two series of novel modified silicas have been prepared in which individual dendritic branches have been attached to aminopropylsilica using standard peptide coupling methodology. The dendritic branches are composed of enantiomerically pure l-lysine building blocks, and hence, the modified silicas have the potential to act as chiral stationary phases in chromatography. In one series of modified silicas, the surface of the dendritic branch consists of Boc carbamate groups, whereas the other has benzoyl amide surface groups. Different coupling reagents have been investigated in order to maximize the loading onto the solid phase. The new supported dendritic materials have been fully characterized with properties of the bulk material determined by elemental analysis, 13C NMR, and IR spectroscopy, whereas XPS provides important information about the surface of the modified silica exposed to the incident X-rays, the key region in which potential chromatographic performance of these materials will take place. Although the bulk analyses indicate that loading of the dendritic branch onto silica decreases with increasing dendritic generation (and consequently steric bulk), XPS indicates that the optimum surface coverage is actually obtained at the second generation of dendritic growth.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The purpose of this descriptive study was to document the level of awareness that laypersons have regarding the role and function of the nurse practitioner (NP). An instrument developed for a similar study, conducted in 1994, comparing patients' and physicians' level of knowledge of the role and function of the NP, had a low reliability. Revision of the instrument was required before further use could be justified.^ A pilot study of 25 laypersons was conducted to ensure that the revised tool was reliable prior to conducting a study. Reliability for the pilot sample was 0.84.^ The study results indicated that the majority of the sample (83%), (n = 100) knew that a NP was a registered nurse who was qualified to diagnose and treat minor illnesses. The level of layperson awareness was limited regarding prescriptive privileges, well-woman exams, and the NPs' ability to perform physical exams, and interpret lab results and x-rays. ^

Relevância:

60.00% 60.00%

Publicador:

Resumo:

There is great difficulty in forming a composite refractory metal niobium with copper. This is due to the fact that Nb-Cu system is almost mutually immiscible and may be neglected solubility between them. These properties hinder or prevent obtaining homogeneous and high-density structures, conventionally prepared. This study aims to analyze the use of high-energy milling process (MAE) to implement these natural difficulties, with regard to the densification of the sintered bodies. The MAE and the press were used in the preparation of powders, to obtain a fine and homogeneous distribution of the grain size. Four loads Nb and Cu powders containing 15% by weight of Cu were then milled for MAE in a planetary type ball mill under various milling times and speeds. The results obtained by MAE were analyzed by scanning electron microscopy (SEM), according to the parameters of time and grinding speed. The samples were compacted under pressure of 200 MPa, were then sintered in liquid phase in a vacuum furnace at temperatures of 1100 ° C / 60 min and 1200 ° C / 60 min. Then it was used to characterize diffraction of X-rays to identify the phases. The microstructures of the sintered samples were observed and evaluated using scanning electron microscopy (SEM). Vickers Microhardness tests were performed, obtaining higher values for the sintered bodies in the largest of the post milling times and the larger grinding speeds. It was found that the liquid phase sintering of the samples that were processed by MAE produced at the end of a homogeneous and densified structure in 77,4% relative to the value of the theoretical density of the composite

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This work presents a new ceramic material obtained through the incorporation of solid waste from the steel industry and known as dedusting powder PAE - in ceramic formulations based on clay, potassium and sodium feldspars, kaolin and talc. Formulations were prepared with ceramic residue levels of 0% (basic mass - MB), 2%, 4% and 8%, subjected to firing at temperatures of 1000 ° C, 1050ºC, 1100ºC and 1150ºC for periods of 15 min. and 120 min. The physicchemical and mechanical properties of these ceramic formulations were determined based on the firing temperature, residence time in the oven and the percentage of waste. Since the physicochemical and mechanical properties of the sintered materials were evaluated by chemical analysis techniques (fluorescence X-rays - FRX), particle size distribution, specific surface area, apparent density, structural analysis by diffraction of X-rays (DRX) and characterization of surface by scanning electron microscopy (SEM). The magnetic response characteristics and the pattern of magnetic ferrites of the samples were analyzed in the assay conditions, having noticed that the saturation magnetic susceptibility depend on the sintering temperature of the material and it is associated with its crystal structure. From the analysis results, it was concluded that the ceramic material with better physical and mechanical properties is obtained when the 8% from PAE residue is added to standard formulation under the burn time of 15 minutes and temperature of 1150ºC.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Tunable tensile-strained germanium (epsilon-Ge) thin films on GaAs and heterogeneously integrated on silicon (Si) have been demonstrated using graded III-V buffer architectures grown by molecular beam epitaxy (MBE). epsilon-Ge epilayers with tunable strain from 0% to 1.95% on GaAs and 0% to 1.11% on Si were realized utilizing MBE. The detailed structural, morphological, band alignment and optical properties of these highly tensile-strained Ge materials were characterized to establish a pathway for wavelength-tunable laser emission from 1.55 μm to 2.1 μm. High-resolution X-ray analysis confirmed pseudomorphic epsilon-Ge epitaxy in which the amount of strain varied linearly as a function of indium alloy composition in the InxGa1-xAs buffer. Cross-sectional transmission electron microscopic analysis demonstrated a sharp heterointerface between the epsilon-Ge and the InxGa1-xAs layer and confirmed the strain state of the epsilon-Ge epilayer. Lowtemperature micro-photoluminescence measurements confirmed both direct and indirect bandgap radiative recombination between the Γ and L valleys of Ge to the light-hole valence band, with L-lh bandgaps of 0.68 eV and 0.65 eV demonstrated for the 0.82% and 1.11% epsilon-Ge on Si, respectively. The highly epsilon-Ge exhibited a direct bandgap, and wavelength-tunable emission was observed for all samples on both GaAs and Si. Successful heterogeneous integration of tunable epsilon-Ge quantum wells on Si paves the way for the implementation of monolithic heterogeneous devices on Si.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A radioisotope energy-dispersive X-ray (EDX) system has been used on board the German research vessel "Valdivia" during an exploration expedition in the northern equatorial Pacific in 1973. The instrumentation used consisted of an X-ray detection system incorporating a 30 mm2 effective-area Si (Li) detector with a measured energy resolution of 195 eV for Mn K alpha X-rays, standard nuclear electronics, a 1024-channel analyser and a data read-out unit. The X-ray spectra in the manganese-nodule samples were excited by a 30-mCi 238Pu source. The six elements Mn, Fe, Co, Ni, Cu and Zn were analysed on board. Precision values for the analyses were less than 3% for Mn, Fe, Ni, Cu and Zn and about 5% for Co. A total amount of 350 analyses was carried out during a one-month cruise. Average contents of 190 analysed whole manganese-nodule samples from all the sampling sites of the covered area were 23.3% Mn, 6.7% Fe, 0.23% Co, 1.16% Ni, 0.94% Cu and 0.10% Zn. The average content of the base metals expressed as the sum of the Co, Ni, Cu and Zn contents was 2.48%. A linear relationship between Mn and Ni in all analysed samples, including whole manganese-nodule samples, zones of manganese nodules and manganese crusts, was observed. The Mn/Ni ratio calculated by regression analysis was 23.0. Zonal variations of the chemical contents of the six elements in the manganese nodules were found. A size classification of the manganese nodules has been suggested. Geochemical correlations of Cu and Ni versus Mn/Fe in the investigated samples are given.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The past decade has seen a dramatic increase in interest in the use of gold nanoparticles (GNPs) as radiation sensitizers for radiation therapy. This interest was initially driven by their strong absorption of ionizing radiation and the resulting ability to increase dose deposited within target volumes even at relatively low concentrations. These early observations are supported by extensive experimental validation, showing GNPs' efficacy at sensitizing tumors in both in vitro and in vivo systems to a range of types of ionizing radiation, including kilovoltage and megavoltage X rays as well as charged particles. Despite this experimental validation, there has been limited translation of GNP-mediated radiation sensitization to a clinical setting. One of the key challenges in this area is the wide range of experimental systems that have been investigated, spanning a range of particle sizes, shapes, and preparations. As a result, mechanisms of uptake and radiation sensitization have remained difficult to clearly identify. This has proven a significant impediment to the identification of optimal GNP formulations which strike a balance among their radiation sensitizing properties, their specificity to the tumors, their biocompatibility, and their imageability in vivo. This white paper reviews the current state of knowledge in each of the areas concerning the use of GNPs as radiosensitizers, and outlines the steps which will be required to advance GNP-enhanced radiation therapy from their current pre-clinical setting to clinical trials and eventual routine usage.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

A small scale sample nuclear waste package, consisting of a 28 mm diameter uranium penny encased in grout, was imaged by absorption contrast radiography using a single pulse exposure from an X-ray source driven by a high-power laser. The Vulcan laser was used to deliver a focused pulse of photons to a tantalum foil, in order to generate a bright burst of highly penetrating X-rays (with energy >500 keV), with a source size of <0.5 mm. BAS-TR and BAS-SR image plates were used for image capture, alongside a newly developed Thalium doped Caesium Iodide scintillator-based detector coupled to CCD chips. The uranium penny was clearly resolved to sub-mm accuracy over a 30 cm2 scan area from a single shot acquisition. In addition, neutron generation was demonstrated in situ with the X-ray beam, with a single shot, thus demonstrating the potential for multi-modal criticality testing of waste materials. This feasibility study successfully demonstrated non-destructive radiography of encapsulated, high density, nuclear material. With recent developments of high-power laser systems, to 10 Hz operation, a laser-driven multi-modal beamline for waste monitoring applications is envisioned.